Professional Documents
Culture Documents
Please
Recycle
Contents
Preface ix
v
▼ Specify Host Behavior When the Host Stops Running (CLI) 10
▼ View and Configure Host Control Information (Web Interface) 10
Managing Host Diagnostics and POST 12
▼ Specify the Level of Diagnostics (CLI) 12
▼ Change the Diagnostics Mode (CLI) 13
▼ Specify Diagnostic Trigger Conditions (CLI) 13
▼ Choose the Amount of Verbosity in Diagnostic Output (CLI) 14
▼ Manage Diagnostic Settings (CLI) 15
Managing System User Interactions 16
▼ Enable the System to Send a Break Signal or Force a Core Dump
(CLI) 16
▼ Display Host Status Information (CLI) 16
vi Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Managing Power Usage and Monitoring Power Consumption 28
Power Management Interfaces 28
Power Management Terminology 28
▼ View Power Management Properties (CLI) 30
▼ View the Total Power Consumed by the System (CLI) 30
▼ Viewing Total Available Power (CLI) 31
▼ Monitoring Permitted Power Consumption (CLI) 32
Using the Power Consumption Control Interfaces 32
▼ Setting the Power Policy (CLI) 32
▼ Viewing the Power Policy (CLI) 33
▼ Viewing Power Management Properties (Web Interface) 33
Managing Network Access 34
▼ Disable or Re-Enable Network Access to the SP (CLI) 34
▼ Display the DHCP Server’s IP Address (CLI) 34
Managing SSH Server Settings 35
▼ Changing the Type of SSH Keys (CLI) 35
▼ Generating a New Set of SSH Keys (CLI) 35
▼ Restarting the SSH Server (CLI) 36
▼ Enable or Disable the SSH Service (CLI) 36
▼ Managing SSH Server Settings (Web Interface) 36
Monitoring Active System Faults 37
▼ Displaying Active System Faults 37
Managing Devices 39
Managing Virtual Keyswitch Settings 39
▼ Specify Host Behavior (CLI) 39
▼ Control the Virtual Keyswitch (Web Interface) 40
Contents vii
Sensors on the Sun Blade T6320 Server Module Server 42
Indicators on the Sun Blade T6320 Server Module 42
Index 77
viii Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Preface
This document contains information about the Oracle Integrated Lights Out Manager
(ILOM) firmware for the Sun Blade T6320 server module from Oracle. ILOM features
are covered in the ILOM 3.0 documentation collection. This document augments that
collection, providing information that only pertains to the Sun Blade T6320 server
module.
ILOM firmware is used to manage and administer the Sun Blade T6320 Server
Module.
To fully use the information in this document, you must have thorough knowledge of
the topics discussed in these documents.
■ Sun Blade T6320 Server Module Product Notes
■ Oracle Integrated Lights Out Manager (ILOM) Documentation Collection
■ ILOM CMM documentation for your Sun Blade modular system (chassis)
ix
Related Documentation
The documents listed as online are available at:
(http://docs.sun.com/app/docs/prod/blade.t6340)
(http://docs.sun.com)
For more information about how to work with ILOM features that are common to all
platforms managed by ILOM, the following documentation provides information.
x Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
For more information about how to work with your host server, the following
documentation provides information.
Task Title
Documentation Feedback
Submit comments about this document by clicking the Feedback[+] link at
(http://docs.sun.com). Include the title and part number of your document
with your feedback:
Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320
Server Module, part number 820-7145-11.
Preface xi
xii Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Understanding ILOM for the Sun
Blade T6320 Server Module
This chapter introduces ILOM for the Sun Blade T6320 Server Module.
ILOM Overview
Integrated Lights Out Manager (ILOM) is system management firmware that is
preinstalled on some SPARC servers. ILOM enables you to actively manage and
monitor components installed in your server. ILOM provides a browser-based
interface and a command-line interface, for both the Chassis Monitoring Module
(CMM) of a Sun Blade modular chassis and for the Sun Blade T6320 Server Module,
as well as SNMP and IPMI interfaces. For general information about ILOM, see the
Oracle Integrated Lights Out Manager (ILOM) 3.0 Concepts Guide.
Note – For information about upgrading, installing, and configuring ILOM on your
service processor see the firmware installation instructions in the Sun Blade T6320
Server Module Installation Guide and the product notes for your server.
1
Chassis Monitoring Module Features
The ILOM chassis monitoring module (CMM) manages the Sun Blade modular
system chassis. CMM provides management of chassis components, and a method of
accessing the service processors in individual server module. The CMM also
provides automatic control of the chassis fan speed. For information about using the
CMM ILOM with your chassis, refer to the ILOM administration guide for your
chassis.
Note – You cannot use Sun Update Connection Manager to obtain system firmware.
For information about setting other service processor settings back to the factory
defaults, refer to “Resetting the Variables to the Defaults Using ILOM” on page 44.
2 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Managing the Host
This chapter contains information on ILOM features on the Sun Blade T6320 Server
Module that augment the array of properties that are common to ILOM on other
platforms. In particular, this chapter describes the properties in the /HOST name
space. This chapter consists of:
Description Links
3
Resetting the Host
The reset command generates a graceful or forced hardware reset of the host server.
By default, the reset command gracefully resets the host. If a graceful reset is not
possible, a forced reset is performed. For a list of available options for the reset
command in both the ILOM and ALOM compatibility CLIs, see TABLE: ALOM CMT
Shell Status and Control Commands on page 55.
Boot Mode
You can use the boot mode (bootmode) properties to specify how ILOM handles
booting. This ability is useful to override particular OpenBoot or LDoms settings
that might be incorrect, to set up OpenBoot variables using a script, or similar tasks.
For example, if the OpenBoot settings have become corrupt, you can set the
bootmode state property to reset_nvram then reset the server to its factory default
OpenBoot settings.
Service personnel might instruct you to use the bootmode script property for
problem resolution. The full extent of script capabilities are not documented and
exist primarily for debugging.
4 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
bootmode properties can be configured using either the ILOM command-line
interface (CLI) or the web interface.
where the config property takes a configname value such as a named logical
domain configuration downloaded to the SP using the Logical Domains software.
For example, if you have created a logical domain configuration called
ldm-set1:
To return the boot mode config to the factory default configuration, specify
factory-default.
For example:
Note – If you set /HOST/bootmode config="", ILOM sets the config to empty.
Note – state=reset_nvram will return to normal after the next server reset or 10
minutes (see expires property in “Display Host’s Boot Mode Expiration Date
(CLI)” on page 7). config and script properties do not expire and will be cleared
upon the next server reset or manually by setting value to "".
where script controls the host server OpenBoot PROM firmware method of
booting. script does not affect the current /HOST/bootmode setting. value can be
up to 64 bytes in length. You can specify a /HOST/bootmode setting and set the
script within the same command.
For example:
After the server resets and OpenBoot PROM reads the values stored in the script,
the OpenBoot PROM sets the OpenBoot PROM variable diag-switch? to the
user-requested value of true.
Note – If you set /HOST/bootmode script="", ILOM sets the script to empty.
6 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
▼ Display Host’s Boot Mode Expiration Date (CLI)
● At the -> prompt, type:
where expires is the date and time when the current boot mode will expire.
You can use the ILOM web interface to view or configure the four aspects of boot
mode control:
■ State
■ Expiration Date
■ Script
■ LDom Configuration
1. Log in to the ILOM web interface as Administrator (root) to open the web
interface.
7. Click Save.
/HOST macaddress is the MAC address for the net0 port. The MAC addresses for
each additional port increments from the /HOST macaddress. For example, net1 is
equal to the value of /HOST macaddress plus one (1).
8 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
▼ Display the Host’s OpenBoot Version (CLI)
The /HOST obp_version property displays information about the version of
OpenBoot on the host.
10 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
ILOM enables you to view or configure several host control features. There are six
aspects to host control:
■ MAC address
■ OpenBoot version
■ POST version
■ HOST status
■ Auto Run On Error
■ Auto Restart Policy
1. Log in to the ILOM web interface as Administrator (root) to open the web
interface.
12 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
● At the -> prompt, type:
where value is one (or a combination, supplied within quote marks and separated
by a space) of the following:
■ user-reset - Run diagnostics when the system is reset.
Commands:
set
show
->
14 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
■ debug - Diagnostics print extensive debugging output on the system console,
including devices being tested and debug output of each test.
The default value is normal.
For example:
Commands:
cd
set
show
->
For example:
Commands:
cd
set
show
->
16 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
● At the -> prompt, type:
For example:
Commands:
cd
set
show
->
This chapter contains information on ILOM properties on the Sun Blade T6320 Server
Module that augment the array of properties that are common to ILOM on other
platforms. In particular, this chapter covers properties in the /SP name space. This
chapter consists of:
Description Links
19
Storing Customer Information
This section describes ILOM features that enable you to store information (for
purposes such as inventory control or site resource management) on the SP and FRU
PROMs.
■ “Change Customer FRU Data (CLI)” on page 20
■ “Change System Identification Information (CLI)” on page 20
■ “Change Customer Identification Information (Web Interface)” on page 21
20 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
▼ Change Customer Identification Information
(Web Interface)
ILOM provides features that enable you to store information on FRUs and the SP.
1. Log in to the ILOM web interface as Administrator (root) to open the web
interface.
9. Click Save.
2. Reset the service processor so that the new property value can take effect.
22 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
1. Log in to the ILOM web interface as Administrator (root) to open the browser
interface.
The console buffer can contain up to 1 Mbyte of information. If ILOM senses a host
server reset, it writes boot information and initialization data into the console buffer
until ILOM is notified by the server that the Solaris OS is up and running.
If ILOM senses a host server reset, it writes boot information and initialization data
into the console buffer until ILOM is notified by the server that the Solaris OS is up
and running.
Note – You must have Administrator level user permission to use this command.
Note – Timestamps recorded in the console log reflect server time. These timestamps
reflect local time, and the ILOM console log uses UTC (Coordinated Universal Time).
The Solaris OS system time is independent of the ILOM time.
Note – Changing the escape character does not take effect in a currently active
console session.
24 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
■ “Manage Configuration Policy Settings (Web Interface)” on page 27
ILOM records the current power state of the server in nonvolatile storage. If the
HOST_LAST_POWER_STATE policy is enabled, ILOM can restore the host to the
previous power state. This policy is useful in the event of a power failure, or if you
physically move the server to a different location.
For example, if the host server is running when power is lost and the /SP/policy
HOST_LAST_POWER_STATE property is set to disabled, the host server remains off
when power is restored. If the /SP/policy HOST_LAST_POWER_STATE property is
set to enabled, the host server restarts when the power is restored.
26 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
● At the -> prompt, type:
1. Log in to the ILOM web interface as Administrator (root) to open the web
interface.
3. Click the Policy radio button of the policy you want to change.
4. Select an Action value to apply the Action (enable or disable) you have chosen.
Term Definition
Actual power The input power measured in watts. This is the actual power consumed
by all the power supplies in the system.
28 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: Power Management Terms
Term Definition
Permitted power The maximum power that the server will permit to be used at any time.
Available power The input power capacity in watts.
For server module, available power is the amount of power available to
the server module from the chassis.
Power policy The setting that governs system power usage at any point in time. Four
power policies are supported: Performance, Elastic, Regulated, and Siesta.
The characteristics of each policy setting are as follows:
• Performance: The system is allowed to use all the power that is
available.
• Elastic: The system power usage is adapted to the current utilization
level. For example, power up or down just enough system components
to keep relative utilization at 70% at all times, even if the workload
fluctuates.
• Regulated: N/A
• Siesta: N/A
For example:
/SP/powermgmt
Targets:
history
Properties
actual_power = 193
permitted_power = 320
available_power = 320
Commands
cd
show
->
where
■ actual_power displays the input power (in watts) consumed by all power
supplies in the system.
■ permitted_power displays the maximum power consumption (in watts)
expected.
■ available_power displays the input power capacity (in watts) that is
available to system components.
30 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
● At the -> prompt, type the following command:
for example:
/SP/VPS
Targets:
Properties
type = Power Unit
class = Threshold Sensor
value = 193.000 Watts
upper_nonrecov_threshold = N/A
upper_critical_threshold = N/A
upper_noncritical_threshold = N/A
lower_noncritical_threshold = N/A
lower_critical_threshold = N/A
upper_nonrecov_threshold = N/A
alarm_status = cleared
Commands
cd
show
->
The system contains one property, available_power. The property supports the show
command and returns the value <input available power in watts>.
The system contains one property, permitted_power. The property supports the show
command and returns the value <maximum permitted power consumption in
watts>.
This interface enables you to set and monitor the power policy of the system. The
Power Policy setting is saved across reboots.
The system contains one property, policy. This property supports the show and set
commands. Two power policies are supported, performance and elastic. (Regulated
and Siesta policies are not supported currently.) For a description of each of these
values, see the definition of Power Policy in TABLE 3-1.
32 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
▼ Viewing the Power Policy (CLI)
● Type the show command to display the power policy:
For example:
1. Log in to the ILOM web interface as Administrator (root) to open the web
interface.
Note – Elastic and Regulated policy values are not supported currently.
● Type:
/SP/network
Targets:
Properties:
commitpending = (Cannot show property)
dhcp_server_ip = 10.8.31.5
ipaddress = 10.8.31.188
ipdiscovery = dhcp
34 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
ipgateway = 10.8.31.248
ipnetmask = 255.255.252.0
macaddress = 00:14:4F:7E:83:4F
pendingipaddress = 10.8.31.188
pendingipdiscovery = dhcp
pendingipgateway = 10.8.31.248
pendingipnetmask = 255.255.252.0
state = enabled
Commands:
cd
set
show
36 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
4. Click Generate RSA Key or click Generate DSA Key to generate a new key type
and a new key.
If you have generated a new key, you must restart the SSH server for the new key
to take effect.
Note – When the SSH server is restarted or disabled, any CLI sessions running over
SSH will be terminated immediately.
The shortcut produces the same output as the longer command string, displaying
all active faults in the system in a concise, tabular format. Sample output:
39
■ locked – The system can power itself on, however you are prohibited from
updating any of the flash devices or setting
/HOST send_break_action=break.
1. Log in to the ILOM web interface as Administrator (root) to open the web
interface
4. Click Save.
40 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
IPMI Sensor Reference
The IPMI interface limits sensor names to 16 characters. Sensor names must
sometimes be shortened to fit this character limit. For example, /SYS is sometimes
removed from the beginning of the path, or CMP0 might be abbreviated to P0.
41
Sensors on the Sun Blade T6320 Server
Module Server
TABLE: Sensors on the Sun Blade T6320 Server Module
ILOM supports some of the features of the ALOM CMT command-line interface by
means of a compatibility shell. There are significant differences between ILOM and
ALOM CMT. This chapter describes those differences. This chapter includes the
following topics:
■ “Limits to Backward Compatibility” on page 45
■ “Create an ALOM CMT Compatibility Shell” on page 47
■ “ILOM and ALOM CMT Command Comparison” on page 50
Caution – In ILOM, if you change the value of the property and reset the SP
without committing the change, the new property setting will not be retained.
45
▼ Commit a Change to a Network Configuration
Property
1. Change the value of the target network configuration property.
2. Use either the ALOM CMT command setsc ser_commit true or the ILOM
command set /SP/serial/external commitpending=true to commit the change.
Refer to “ILOM and ALOM CMT Command Comparison” on page 50 for a list of
variables and corresponding properties.
ALOM CMT
Variable Comparable ILOM Property
46 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
▼ Create an ALOM CMT Compatibility
Shell
Your server is configured to operate under an ILOM shell, by default. You can create
an ALOM compatibility shell if you prefer to use commands that resemble ALOM
CMT commands to administer your server.
Note – If you have performed an upgrade of the firmware from an earlier version
and selected the option to preserve the settings of your earlier version of ILOM, you
can continue to use your prior settings (including the username admin and
password) without recreating the admin username, described in this section. If you
use the original password for the username root supplied with ILOM firmware,
ILOM warns you that the password is still set to the factory default.
1. Log onto the service processor with a username that has been assigned the user
management (u) role.
When powered on, the SP boots to the ILOM login prompt.
Version 3.0.x.x
->
2. Create a user named admin, and set the admin account roles to aucro and the
CLI mode to alom.
Note – The asterisks in the example will not appear when you enter your password.
You can combine the create and set commands on a single line:
3. Log out of the root account after you have finished creating the admin account.
-> exit
48 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
4. Log in to the ALOM CLI shell (indicated by the sc> prompt) from the ILOM
login prompt.
Daemons ready
Version 3.0.x.x
sc>
In the ALOM CMT compatibility shell (with a few exceptions) you can use
commands that resemble the commands of ALOM CMT. Remember that the
ALOM CMT compatibility shell is an ILOM interface. The comparisons between
the ILOM CLI and the ALOM CMT compatibility CLI are described in “ILOM and
ALOM CMT Command Comparison” on page 50.
SC> console
host>
2. To switch from the console to the ALOM CMT shell, type hash-period:
host> #.
sc>
sc> logout
2. Log in to the ILOM CLI as usual, using an account other than the admin account
(such as root).
The admin account cannot be used for the ILOM CLI as long as its CLI mode is set
tot he value alom.
In the ALOM CMT compatibility shell (with few exceptions), you can use
commands that resemble the commands of ALOM CMT. Remember that the
ALOM CMT compatibility shell is an ILOM interface. Refer to the Sun Blade T6320
Server Module Service Manual for information about service-related ALOM CMT
compatibility shell commands.
50 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Note – By default, when displaying information ALOM CMT commands limit their
output to a terse format, offering more verbose output if a –v flag is supplied with
the command. The ILOM show commands do not have a terse output format. These
commands always provide verbose output.
52 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: ALOM CMT Shell Configuration Commands (Continued)
set /SP/services/ssh
ssh-keygen –t generate_new_key_type=[rsa|dsa]
{rsa|dsa}
usershow [username] Displays a list of all user show /SP/users
accounts and permission
levels, and whether
passwords are assigned.
useradd username Adds a user account to create /SP/users/username
ALOM CMT.
userdel [–y] username Deletes a user account from delete [–script] /SP/users/username
ALOM CMT. The –y option
enables you to skip the
confirmation question.
userpassword [username] Sets or changes a user set /SP/users/username password
password.
userperm [username] [c] [u] Sets the permission level for set /SP/users/username role=permissions
[a] [r] [o] [s] a user account. [a|u|c|r|o|s]
54 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: ALOM CMT Shell Status and Control Commands
showenvironment Displays the environmental status of show –o table –level all /SYS
the host server. This information
includes system temperatures, power
supply status, front panel LED status,
hard disk drive status, fan status,
voltage, and current sensor status.
showpower [–v] Displays power metrics for the host show /SP/powermgmt
server.
shownetwork [–v] Displays the current network show /SP/network
configuration information. The –v
option shows additional information
about your network, including
information about your DHCP server.
console [–f] Connects to the host system console. start [–force] /SP/console
The –f option forces the console write
lock from one user to another.
In ILOM, the –force option
terminates the console, permitting you
to start a new console.
break [–D][–c] Drops the host server from running set /HOST send_break_action=
the Solaris OS software into OpenBoot [break|dumpcore]
PROM or kmdb depending upon the
mode in which the Solaris software [start /SP/console]
was booted.
bootmode [normal] Controls the host server OpenBoot set /HOST/bootmode property=value
[reset_nvram] [config= PROM firmware method of booting. (where property is state, config, or
configname][bootscript = script)
string]
reset –d [–n] [–y] The –d option gracefully resets the [set /HOST/domain/control
[–f] [–c] control domain. auto-boot=disable]
The –n option sets the auto-boot reset [–script] [–force]
variable to disable (lasts for one reset). /HOST/domain/control
The –y option enables you to skip the [start /SP/console]
confirmation question.
The –f option forces a hardware reset.
The –c option starts the console.
powercycle [–y] [–f] poweroff followed by poweron. The stop [–script] [–force] /SYS
–f option forces an immediate start [–script] [–force] /SYS
poweroff, otherwise the command
attempts a graceful shutdown.
56 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: ALOM CMT Shell Status and Control Commands (Continued)
poweroff [–y][–f] Removes the main power from the stop [–script][–force] /SYS
host server. The –y option enables you
to skip the confirmation question.
ALOM CMT attempts to shut the
server down gracefully. The –f option
forces an immediate shutdown.
poweron Applies the main power to the host start /SYS
server or FRU.
setlocator [on/off] Turns the Locator LED on the server set /SYS/LOCATE value=value
on or off.
removeblade [-y] Pauses the service processor tasks and set /SYS
illuminates the blue OK to Remove prepare_to_remove_action=true
LED, indicating that it is safe to
remove the blade. The -y option
enables you to skip the confirmation
question.
unremoveblade Turns off the OK to Remove LED and set /SYS
restores the service processor state. return_to_service_action=true
setfru –c data The –c option enables you to store set /SYS customer_frudata=
information (such as inventory codes) data
on all FRUs in a system.
showfru –g lines [–s|–d] Displays information about the FRUs show [FRU]
[FRU] in a host server.
removefru [–y] [FRU] Prepares a FRU (for example, a power set /SYS/PS0
supply) for removal. The –y option prepare_to_remove_action=
enables you to skip the confirmation true
question.
58 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
ALOM CMT Variables
59
TABLE: ALOM CMT Variables and Comparable ILOM Properties (Continued)
sc_cliprompt N/A
sc_clitimeout N/A
sc_clipasswdecho N/A
sc_customerinfo /SP system_identifier
sc_escapechars /SP/console escapechars
sc_powerondelay /SP/policy HOST_POWER_ON_DELAY
sc_powerstatememory /SP/policy HOST_LAST_POWER_STATE
ser_baudrate /SP/serial/external pendingspeed
ser_data N/A
sys_autorestart /SP autorestart
sys_autorunonerror /SP autorunonerror
sys_boottimeout /HOST boottimeout
sys_bootrestart /HOST bootrestart
sys_bootfailrecovery /HOST bootfailrecovery
sys_eventlevel N/A
sys_enetaddr /HOST macaddress
60 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Event Messages Available Through
the ALOM Compatibility Shell
61
■ Messages are sent to the managed system operating system for logging into the
Solaris syslog facility based on the configuration of the sys_eventlevel
variable. Not all versions of the Solaris Operating System support this capability.
Critical Host has been powered off ALOM compatibility shell sends this
message whenever the SC requests a
host power off, including when a user
types the poweroff command.
Critical Host has been powered off ALOM compatibility shell sends this
message when the SC requires an
immediate host power off, including
when a user types the poweroff –f
command.
Critical Host has been powered off ALOM compatibility shell sends this
message when the host power has
turned off. It is also normal for this
event to be sent when the host has reset
itself.
62 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: System Controller Usage Event Messages (Continued)
Major Host has been powered on ALOM compatibility shell sends this
message when the SC requests a host
power on, either because of
sc_powerstatememory or when a user
types the poweron command.
Critical Host has been reset ALOM compatibility shell sends one of
Critical Host has been powered ff these messages when the SC requests a
Critical Host has been powered on host reset, including when a user types
the reset command.
Critical Host System has Reset. ALOM compatibility shell sends this
message when the SC detects that the
host has reset. This message is followed
immediately by the Host has been
powered off event message because
reset is implemented as a powercycle on
these systems.
Minor “root : Set : object = ALOM compatibility shell sends this
/clock/datetime : value = message when a user types the setdate
"datetime": success command to modify the SC date or
time.
Major Upgrade succeeded ALOM compatibility shell sends this
message after the SC firmware has been
reloaded after operation of the
flashupdate command.
Minor “root : Set : object = ALOM compatibility shell sends this
/HOST/bootmode/state: message after a user changes the
value = "bootmode-value": bootmode to normal using the
success bootmode normal command.
Minor “root : Set : object = ALOM compatibility shell sends this
/HOST/bootmode/state: message after a user changes the boot
value = "reset_nvram": success mode to reset_nvram with the
bootmode command.
Minor "root : Set : object = ALOM compatibility shell sends this
/HOST/bootmode/script: message after a user changes the boot
value = "text": success mode boot script. The boot script =
"text" is the text of the boot script
provided by the user.
Minor Keyswitch position has been ALOM compatibility shell sends this
changed to keyswitch_position. message after a user changes the
keyswitch position with the
setkeyswitch command. The
keyswitch_position is the new keyswitch
position.
64 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Environmental Monitoring Event
Messages
The following table displays environmental monitoring event messages from the
service processor (system controller).
Critical SP detected fault at time time. ALOM compatibility shell sends this
Chassis cover removed. message if the chassis cover has been
removed. The platform hardware turns
managed system power off immediately
as a precautionary measure. The event
message System poweron is disabled
should accompany this message to
prevent the use of the poweron
command while the chassis cover is
removed.
Major System poweron is disabled. ALOM compatibility shell sends this
message when the SC refuses to power
on the system, either through the user
poweron command or by the front panel
power button. The SC disables power
on because of an accompanying event,
such as the event indicated by the
message Chassis cover removed. Other
possibilities include a device failure or
insufficient fan cooling.
Major System poweron is enabled. ALOM compatibility shell sends this
message after the condition that caused
power on to be disabled (indicated by
the preceding System poweron is
disabled message) has been rectified.
For example, by replacing the chassis
cover or installing sufficient fans to cool
the system.
Major SP detected fault at time time ALOM compatibility shell sends this
“fault_type 'fault' at location message when a failure or a fault is
asserted" detected. A fault is a lower priority
condition that indicates the system is
operating in a degraded mode.
fault_type is the type of failure that has
occurred, such as temperature, voltage,
current, or power supply.
The location is the location and name of
the device that has the error condition.
The location and name of the device
match the output of the ALOM
compatibility shell showenvironment
command.
This fault event message appears in the
output of the ALOM compatibility shell
showfaults command.
Minor SP detected fault cleared at ALOM compatibility shell sends this
time time current fault at device message to indicate that a prior fault or
asserted. failure has recovered or been repaired.
The fields (time and device) are the
same as the prior fault or failure event.
66 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: Environmental Monitoring Event Messages (Continued)
68 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Host Monitoring Event Messages
The following table displays host monitoring event messages from the service
processor (system controller).
Critical SP detected fault at time time ALOM compatibility shell sends this
component disabled message when a component has been
disabled, either automatically by POST
discovering a fault or by a user typing
the disablecomponent command.
component is the disabled component,
which will be an entry from the
platform showcomponent command.
This fault event message appears in the
output of the ALOM compatibility shell
showfaults command.
Minor SP detected fault cleared at ALOM compatibility shell sends this
component reenabled message when a component is enabled.
A component can be enabled by a user
typing the enablecomponent command
or by FRU replacement if the component
itself is a FRU (such as a DIMM).
component is the name of the component
shown in the output of the platform
showcomponent command.
70 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
Event Messages Available Through the ALOM Compatibility Shell 71
72 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
SCC Backup and Restore
SPARC servers store in the SCC (system configuration card) a subset of the
information backed up and restored by ILOM 3.0. In case of a server failure in which
there is no ILOM backup of SP data, transferring the SCC to the replacement server
can provide partial restoration of the failed server’s configuration data.
73
Information Stored on the SCC
Note – The version of the data on the SCC must match the version of the SCC
daemon running on the SP. If the versions differ, the version on the SCC is ignored.
After SP reset, the SCC data is overwritten.
Properties Targets
/SP/users/username/ name
password
role
cli_mode
/SP/network/ ipaddress
ipdiscovery
ipgateway
ipnetmask
state
/HOST/diag/ trigger
level
verbosity
mode
/HOST/ autorunonerror
autorestart
/SP/policy/ HOST_LAST_POWER_STATE
HOST_POWER_ON_DELAY
BACKUP_USER_DATA
/SP/services/ssh/state N/A
/SP/clients/smtp/ address
port
state
/SP/alertmgmt/rules/[1-15]/ destination
(if the alert is an email alert) level
type
/SP/system_identifier N/A
/SYS/keyswitch N/A
74 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010
TABLE: ALOM CMT Conditional Variables
Variable
sc_clipasswecho
sc_cliprompt
sc_clitimeout
sc_clieventlevel
sc_eschapechars
77
IPMI indicators, 43
IPMI sensors, 42
N
network configuration properties, to commit, 46
O
OpenBoot version, displaying
with CLI, 9
with web interface, 10
P
platform, showing, 15, 16
POST version, displaying
with web interface, 10
property
backup data, 25
system user, 12, 16
R
remote control settings
changing with the CLI, 4
changing with the web interface, 7
S
server, platform information, 15, 16
/SP/serial/external commitpending
property, 46
T
timer, watchdog, 10
W
watchdog timer, 10
78 Oracle Integrated Lights Out Manager (ILOM) 3.0 Supplement for the Sun Blade T6320 Server Module • April 2010