Engineering Report Structural Calculation PROPOSED TWO STOREY APARTMENT BUILDING

Footing Name F1
Column Type Interior

Design Paramters

Pu = 1564 KN
f'c = 28 Mpa
fy = 275 Mpa
Embedment = 1500 mm
qall (Soil Bearing Capacity)= 200 Kpa
Trial "t" = 400 mm
Increment "t" = 50 mm
Minimum "L" = 1000 mm Concentric Footing
bar Ø= 20 mm
Col-x = 600 mm
Col-z = 600 mm

REQUIRED DIMENSIONS
Ps = 1117.142857 KN
Footing Areareq = 5.585714286 mm2
B= 2400 mm
L= 2400 mm Wide Beam Shear
Final Area = 5760000 mm2
Qumax= 271.53 Kpa

WIDE BEAM SHEAR fVc > Vu


fVc = f(f'c)1/2Bd/6
Effective, d1 = 261.94 mm
t= 350 mm
Used t = 400 mm
Punching Shear
PUNCHING SHEAR CHECK

Used d = 315 mm
bo = 3660 mm
β= 1
as = 40
Punching Area = 4922775 mm2
VuPunching = 1336.681096 KN
ff'c1/2bod/3 = 1525.143343 KN Safe
4 Critical Area for Moment
FLEXURAL REINFORCEMENT REQUIREMENTS
d= 315 mm
Mu = 263.93 kN-m steel ratio, r= 0.0051
Rn = 1.231428571 required As = 3848.73
rrqrd = 0.00460 number of bars = 12.25
rmin = 0.0051 say = 13.00 pcs - 20 mmf Both Ways
USE t = 400 mm
Engineering Report Structural Calculation PROPOSED TWO STOREY APARTMENT BUILDING

Both Ways
Engineering Report Structural Calculation PROPOSED TWO STOREY APARTMENT BUILDING

Footing Name F1
Column Type Edge Column (Eccentric Footing)

Design Paramters

Pu = 400 KN
f'c = 28 Mpa
fy = 414 Mpa
Embedment = 1500 mm
qall (Soil Bearing Capacity)= 144 Kpa L 4.372
Trial "t" = 300 mm
Increment "t" = 50 mm 92.9780421
Minimum "L" = 1000 mm 51.0087063 Concentric Footing
bar Ø= 16 mm 41.9693358 min
Col-x = 375 mm 143.986748 max
Col-z = 375 mm

REQUIRED DIMENSIONS
Ps = 285.7142857 KN L/6 = 91.66666667
L= 550 mm e= 87.5
B= 8000 mm L/6 > e = OK
Final Area = 4400000 mm2 Wide Beam Shear
Qamax= -126.918536 Kpa Pass
Qamin= -2.951593861 mm2

Qultimatemax= 177.6859504 Kpa


Qultimatemin= 4.1 Kpa
Qused= 0.1776859504 Mpa

WIDE BEAM SHEAR fVc > Vu Punching Shear


fVc = f(f'c)1/2Bd/6
Effective, d1 = 37.05656082 mm
t= 150 mm
Used t = 300 mm

PUNCHING SHEAR CHECK

Used d = 217 mm
bo = 1559 mm
as = 40
Punching Area = 963805.5 mm2
VuPunching = 171.2546963 KN
ff'c1/2bod/3 = 447.5328029 KN Safe
Critical Area for Moment
FLEXURAL REINFORCEMENT REQUIREMENTS
d= 217 mm
Mu = 21.77 kN-m steel ratio, r = 0.0034
Rn = 0.06420032316 required As = 5870.53
rrqrd = 0.00016 number of bars = 29.20
rmin = 0.0034 say = 30.00 pcs - 16 mmf Both Ways
USE t = 300 mm
Engineering Report Structural Calculation PROPOSED TWO STOREY APARTMENT BUILDING

Both Ways