This document provides technical specifications for an 850 kVA uninterruptible power supply system. The system has dimensions of 1000mm x 830mm x 2200mm and weighs 1100kg. It can operate within an input voltage range of 380-440V at 50Hz. Additional details provided include electrical connections, communication interfaces, performance metrics, operating environment tolerances, certifications, and installation features. Diagrams are attached showing system configuration without and with an optional bypass system.
This document provides technical specifications for an 850 kVA uninterruptible power supply system. The system has dimensions of 1000mm x 830mm x 2200mm and weighs 1100kg. It can operate within an input voltage range of 380-440V at 50Hz. Additional details provided include electrical connections, communication interfaces, performance metrics, operating environment tolerances, certifications, and installation features. Diagrams are attached showing system configuration without and with an optional bypass system.
This document provides technical specifications for an 850 kVA uninterruptible power supply system. The system has dimensions of 1000mm x 830mm x 2200mm and weighs 1100kg. It can operate within an input voltage range of 380-440V at 50Hz. Additional details provided include electrical connections, communication interfaces, performance metrics, operating environment tolerances, certifications, and installation features. Diagrams are attached showing system configuration without and with an optional bypass system.
Nominal Power 850 kVA Width (A) 1000 mm Nominal Voltage 400 V Depth (B) 830 mm Input Voltage Range 380 - 440 V Height (C) 2200 mm Frequency 50 Hz Weight 1100 kg Electrical Connection Bus bar Aluminium Input Terminal 240mmq, 12 mm Output Terminal 240mmq, 12 mm Raccomanded Cable Size 4 x 240 mmq Earth Cable Size 50 mmq Communication Connection Internal serial Modbus RTU/TCP External web (optional) Ethernet/Modem GSM-GPRS Meter Accuracy Class B TA Class 0,5 CT Ratio 1000/5 Performance Range Saving 5 - 15% System Efficiency > 99% Power consumption 0,4 kWh Ambiental Data Warranty Temperature 5 - 50°C Machine 2 years Humidity 0 - 95% Expected Life 10 years Altitude < 2.000 m Performance degradation None Other Features Certifictions IP Protection 31 Declaration of CE conformity Installation Indoor Aeration Electric Ventilation System Safety power transformers IEC/EN 61558 Automatic By-Pass Yes Electromagnetic compatibility IEC/EN 61000 Max By-pass Corrent 1.600A (40°C) Low-voltage switchgear and controlgear Max Operative Current 1.250A assemblies IEC/EN 61439 Isolation Class H/H Short circuit current lcw 25 kA 1sec By-pass Time Immediately
Sede Legale Sede Operativa
Via Domenichino, 19 Via Galileo Galilei, 46/48 20149 Milano 20091 Bresso - MI T. 02 36 631 400 T. 02 89 612 200 www.icopower.com icopower@icopower.com Technical Data
ATTACHED A Pre-installation diagram without ICO-F system