3456 Generator Set With EMCP II Electrical System: Ccb1-Up Cah1-Up Cbx1-Up 8AZ1-UP
3456 Generator Set With EMCP II Electrical System: Ccb1-Up Cah1-Up Cbx1-Up 8AZ1-UP
WARNING
ASR AIR SHUT-OFF RELAY LFLS LOW FUEL LEVEL SWITCH
SCROLL
ATB AC TRANSFORMER BOX LFSR LOW FUEL SHUTOFF RELAY
HIGH
PUMP STARTING PUMP
ATR ALTERNATOR TEMPERATURE RELAY
COOLANT STOP AID RUN DISPLAY
TEMP
LOW
COOLANT
TEMP
CLEAR
LOW
LOW OIL OIL
MODE
BATT BATTERY
PRESSURE
PRESSURE
EMERGENCY
LOW
FUEL
LEVEL
DISPLAY
MAN MANUAL
STOP
HIGH WATER
SYSTEM
NOT IN PANEL
BC BATTERY CHARGER MPU MAGNETIC SPEED PICKUP
AUTO
LIGHTS LH
TEMP
LOW
ENGINE
OVERSPEED
BATTERY
VOLTAGE RH BCF BATTERY CHARGER FAILURE SWITCH MV MOTOR VALVE/SOLENOID VALVE
LH/RH
LOW
COOLANT
LEVEL
SELECT
BTR BEARING TEMPERATURE RELAY
OVERCRANK
EMERGENCY
STOP
STOP
FAULT R R OFF
SHUTDOWN RESET
FAULT
ALARM
ALARM
COOLDOWN
AUT
560-642 154-3045
Electrical System
ECLS ENGINE COOLANT LOSS SENSOR PS PINION SOLENOID
ECM ELECTRONIC CONTROL MODULE PSL PUMP STOP LIGHT
ECS ENGINE CONTROL SWITCH PSPB PUMP STOP PUSHBUTTON
PWM PULSE WIDTH MODULATED
ECTS ENGINE COOLANT TEMPERATURE SENSOR
EFR ENGINE FAILURE RELAY
CCB1-UP EGR ELECTRONIC GOVERNOR RELAY
RAN REMOTE ANNUNCIATOR
EOPS ENGINE OIL PRESSURE SENSOR
CAH1-UP EOTS ENGINE OIL TEMPERATURE SENSOR
RDM
RFI
RELAY DRIVER MODULE
RADIATED FREQUENCY IMMUNITY
HC HEATER CONTACTOR
VAR VOLTAGE ADJUST RHEOSTAT
F11
F12
+
~ A1 B1 15
6 5 4 6 5 4 6 5 4
F13
3 2 1 3 2 1 3 2 1
3 2 1
CATERPILLAR A
AB FSM3U
1mn
-B S D +B
.8
1.0
.6 t
0
.4
TBC
.2
B A B A B A
EPIR 9 8 7 16 18 A2 ~
- 9 8 7 9 8 7
51 51
61 61
52 52
53 53
RENR2477-02 VOL 1 of 2
L1 L1
L3 L3
80 80
82 82
AC TERMINAL
DC TERMINAL
STRIP PUMP
STRIP
RELAY AC TERMINAL FUSE
STRIP BLOCKS
DC TERMINAL
STRIP 6 5 4 6 5 4 6 5 4
3 2 1 3 2 1 3 2 1
GROUND FAULT
RELAY
F50 F51 F52
B A B A B A
WINDING
9 8 7 9 8 7 9 8 7
TEMPERATURE 6
3
5
2
4
1 PUMP
KWR ALR PR RELAYS CONTACTOR
GND5
GND6
CCM+
GND2
GND1
GND3
GND4
SP1A
136
137
CCM-
101
110
131
108
109
202
203
206
207
157
159
HC1
HC4
SP4
SP2
SP2
SP1
51
T0
50
50
50
SP3
52
53
45A
BO
MT
ER
SV
SV
SV
SV
D+
FP
EL
ES
30
37
57
57
59
62
62
63
67
90
99
80
82
87
30
30
30
38
D-
10
10
17
18
21
89
67
22
19
20
20
88
46
45
34
1
1
1
1
2
2
2
6
5
5
2
2
2
2
B A
9 8 7
AR GNDFR
ATR ATR ARMING
AC TERMINAL STRIP (TBA1) RELAY MERLIN GERIN
PC
C60N
adjust adjust
set point set point
read read
F16 F17 F18 MCB1 F21 F22 F32 F33
12 567 12 567 HC
FUSE
TERMINAL STRIP INTERFACE BLOCKS
70
83
85
77
5
30 Page,
HEATER
CIRCUIT CONTACTOR
BREAKER
BC
ABCDEFGHIJ ABCDEFGHIJ
adjust adjust
B set point
read
set point
read
12 567 12 567
DC PANEL
BTR ATR BATTERY
GND CHARGER
2 AC PANEL
DC CHASSIS 2
F50 F51 F52
AC TERMINAL
3 STRIP
6 5 4 6 5 4 6 5 4 6 BEARING
3 2 1 3 2 1 3 2 1
6 6 5 4 TEMPERATURE
10 3 2 1
B A B A B A 30 RELAY
9 8 7 9 8 7 9 8 7
KWR ALR PR
57 B A
61 9 8 7
O/UVR AR GNDFR
ATR ATR 63
87 PC
ABCDEFGHIJ ABCDEFGHIJ MERLIN GERIN
88 PUMP
multi 9
89 ALARM
RELAY
OFF OFF
12 567 12 567
KILOWATT RELAY
90
DC TERMINAL RELAY
99 F16 F17 F18 MCB1 F21 F22 F32 F33
D+
HC
STRIP
ABCDEFGHIJ
adjust
ABCDEFGHIJ
adjust
D-
set point
read
set point
read CCM+
12 567 12 567
DC 40 PIN CCM- 6 5 4 6 5 4 6 5 4
BTR ATR CONNECTOR ATA+ 3 2 1 3 2 1 3 2 1
ATA-
BC
RDM
AC DC
47
48 (TBA 2) FUSE
49
BLOCKS
231A
232A CUSTOMER
233A TERMINAL STRIP B A B A B A
231B
GND 148 139 131 131 132
8 7 8 7 8 7
DC TERMS
9 9 9
232B
233B
GND1
GND2
GND
EF1
EF2
101
108
109
110
133
133
136
137
157
159
202
203
206
207
132
140
142
209
210
120
122
124
231C
232C
233C
132 131 131 139 148 GND
64 (TBD 2)
65
AC 40 PIN 66
CONNECTOR (TBA 2)
AC TERMS
RFI
GND
SP1
SP2
SP3
SP4
10
10
30
30
36
71
72
74
81
81
84
2
2
2
3
6
132 131 133 GND GND
VOLTAGE (TBD 2)
GROUND
7W-9799
REGULATOR
154
156
DC PANEL AC PANEL
VIEW B-B
MARSHALLING BOX CUSTOMER TERMINAL STRIP CHASSIS ONLY SHOWN
CUSTOMER (FRONT VIEW) B (TBC)
GROUND BAR
MARSHALLING BOX
8 7 6 5 4 3 2 1
CUSTOMER
240V
AC SUPPLY
SYMBOLS
240
Relay Contact Panel 70 way Marshalling Box
Standard Wiring Lamp ATB Terminal 23 C
(Normally Closed) Connector Customer DC Term.
L1 L2
Generator Frame Breakdown Diode Marshalling Box DC 6
DC Connector No. 1 Marshalling Box
Customer Wiring C
(Chassis) Ground (Bi-directional) Terminal (Black) Customer AC Term.
C C C
Marshalling Box AC 7 DC Connector No. 2 Magnetic Pick-up
Package Options Earth Ground Diode 2
GND 132 133 Terminal (Grey) Engine Connector
GSC 40 Way AC Connector From Coolant Loss Engine
Alternative Wiring Solenoid Fuse 7 A
Harness Connector Gen (Green) Connector (ECLS)
NOTE Q
A
H1 H3
(Normally Open) Connector Connector
B
H2 H4
HC
133 141 142 142 142
F18
3 4 240 VAC
8A BATTERY
CHARGER NOTE L SLR CHART
SEE CHART SYNCHRONIZING OUTPUT LOAD SPECIFICATIONS
BELOW NOTE P VOLT LINE
RESISTOR TAP FOR GSC RELAY MODULE
MCB1
16 AMP
NOTE K + - TO LINE
SETTING CHART
HC RELAY MODULE RATING FOR RATING FOR
1600 OHM
132 138 148 148 JACKET BATTERY DISCONNECT
1L1 208 USE E-D 1760 OHM TERMINAL NO. RESISTIVE INDUCTIVE
1 2 5 6 WATER BATTERY BATTERY SWITCH NOTE BL A LOADS LOADS
+ - CHARGER 240 USE E-C 2400 OHM
3200 OHM
HEATER 240 VAC BATTERY CHARGER TERMINAL CHART
UL B 13, 14, 0-.45A, 24VDC *N/A
CB1 60A NOTE N 300 USE E-B 5600 OHM
14 AWG 4 2 BATTERY CHARGER DESIGNATION 40
ALT 15, 16, 10A, 24VDC 10A, 24VDC
380 USE E-B 5600 OHM
A B PS1 17, 18,
C
640 OHM
14 AWG SM1 400 USE E-B 5600 OHM
19, 21, 20,
10 AMP NON-UL 0 240
HC 416 USE E-A 7200 OHM 22, 24,
1760 OHM
139 3 1 5 AMP NON-UL
D
133 134 139 L N 480 23, 36, 10A, 24VDC 5A, 24VDC
CB2 20A SMMS1 USE E-A 7200 OHM
24
3 4 7 8 1L2 25 OR 110VAC 7.5A,110VAC
PS1
2 1 NOTE AE GENERATOR WINDING OVERTEMPERATURE ALARM/SHUTDOWN
1 E * DO NOT CONNECT INDUCTIVE LOADS TO
2 2 THESE TERMINALS
3
LAMP 1 +D -E 30
ELS 2
HC 1 2 T1 T2 T3 ATR1
132 138 148 1 30
F19
5 6 10 AMP 4 WH 171 P VOLTAGE REGULATOR TERMINAL CHART
10A
3 74
GENERATOR RUNNING RELAY TC4 REGULATOR
240V RD 172 Q 21 TERMINAL DESTINATION CROSS REFERENCE
LAMP 2 37
6
BLOCK NOTE BK NOTE R A B C D E F G H J K L M N O P Q R S
WH 173
HEATER 5
57
31 ENCLOSURE LIGHTING 30 TC1
RD VR6-B 6A
HC GRR 174 7 - 4 8 9 - - 5A 22 24 20 F1 F2 26 28 30 6
87 87 7 75
133 134 139 C NOTE BG 45
F20 7 4 DIGITAL 7 - - - 8 B+ B- 5 22 24 20 F1 F2 26 28 30 6
7 8 11
10A 2 PF/KVAR 7 45 44 - - 8 B+ B- 5 22 24 20 F1 F2 26 28 30 6
GND 58
GRR 32
88 2
88
C
7 1
59 SP2 GOVERNOR TERMINAL CHART
133 131 33
89 89
C 2 GOVERNOR TERMINAL DESTINATION CROSS REFERENCE
A B C D E F G H J K
AUTOMATIC FUEL TRANSFER SYSTEM
INTERNAL FLYBACK 27 RM27 2
5 36 PSPB 64 24 PR OL 1 3 2 PWM S D B- B- B+ 3 2 1 - -
CIRCUITRY +D -E
132 207 207 207 206 206 205 204 131 1 LOADSHARE
F22 PC COMMON ALARM SHUTDOWN 19 - 21 16 15 28 27 26 14 13
1A 2A 9 6 95 96 RM32 RM5 RM19 37 2
2A A1 A2
33 NOTE U
F4 ATR2
ALR 10A ASR 1 30
64 12 181 P
C 1 RM16 A B
E E
38 3 74
7 4 GRR TC5
182 Q
ALR CTR 6
65 RM30 RM17
70 C WH
PSL F1 183
OFF/RESET
7 1 5
CONTACTS
PC 3 42
10A RM3 CTR TC2
MANUAL
207 203 203 203 131 66 RD 184 OFF
R NOTE R 7 75
C
AUTO
STOP
61 62 RESET
99
22
R6 ELECTRONIC CONTROL 69
TEMP FAULT
PR 2 SPARE 6 6 GROUP 23
85 23
AUTOMATIC FUEL TRANSFER SYSTEM 3 63 63 63
8 5 36 C 7 6 5 4 3 2 1
27
70 FUEL SUPPLY FROM FREESTANDING BULK TANK
PSL 5
PC 3 42 MV 5 LOW OIL 25 12 1 4 3 2
203 131 PR 90 90 90 R5
207 203 203 35
R PRESS FAULT
26
61 62 7 4
4 30
NFPA ALARM MODULES 30
-B
4
3
PRL PSPB 10 LFLS A1 A2 NOTE AA OVERCRANK 28
PC 1 40 LFLS TDR R4
202 131 211 84 84 81 83 83 2 FAULT 2
207 202 202 10 30
G F23 PR 1 1+
-7 29
53 54 2 AMP 1B 2B 3 4 1 2 A B B1 1 NOTE AY
33
NOTE M RM2 1 1 NOTE AH
(Dimensions: 39 inches x 28 inches)
C C
57 57 30 30
1 2 C C 99
1+ 9 SPARE FAULT INPUT LED #2
MANUAL SYNCHRONIZING MODULE NOTE BM
90
51 SL2 SLR2 10 SPARE FAULT INPUT LED #3
15 6 3
156 159 160 162 110 PL1 CUSTOM ALARM MODULE
C F33 2 11 SPARE FAULT INPUT LED #4
NOTE AB
3 OR 4 POLE 2 AMP 23 PLS
11 2 1 NOTE AE 3 SPARE FAULT INPUT LED #5
OPTIONAL MOLDED 154 157 161 163 RM12 RM39 74
108 10 10 9 8
CASE CIRCUIT C F32 F10 PL2 GEN WINDING OVERTEMP ALARM 20 4 SPARE FAULT INPUT LED #6
BREAKER 3 2 2 12 TEST
2 AMP 4 1 10A
SL1 SLR1 5 SPARE FAULT INPUT LED #7
2 1 NOTE AF 68
SS 45 9 13 SILENCE
NOTE BC 12 6 SPARE FAULT INPUT LED #8
10 71 GEN BEARING OVERTEMP ALARM 12
10 69 30
C 14 HORN -7
15
GROUND FAULT RELAY 12
2 GNDFR NOTE E
2 10 73
AR RM34 RM7 RM22 6 10 R9 13 R9
6 6 11
NOTE E B A F5 C 14 11
15 GROUND FAULT OUTPUTS
AR GFR 14
122 10A 10
118
A1 CAM
T0 T1 T2 T3 7 4 COMMON ALARM SHUTDOWN 44
NOTE AH 18
9
120 36 LFLS NOTE AZ
EF2 A2 108 NOTE U 70 16
11 R8 R8 8
L A B REMOTE
T1 T11 ALR 5 6 OUTPUTS 3 HORN INPUT 1
GNDFCT EF1 17 NFPA 99
H1 T1 X1 J1-1 91 35 LOW FUEL LEVEL ALARM NOTE AL 7 99
K GNDFR 16 LIGHT
F11 10 1+
21
6
PR1
10
7 32 a 1+ 19 4 HORN INPUT 2
T1 T2 T12 H2 X2 SH 30 R7 R7 5 NOTE BG
J1-2 92 -7
F12 11 TC OUTPUTS 90
SHUNT TRIP CB 20 5 6 7 8 9 10 11
5 75 NOTE AE 2 DATA
T2 32 a 3 24
SH GEN WINDING OVERTEMP SHUTDOWN 14 13 12 11 10 9 8
TC
9 T3 T13 H1 T2 X1 SHUNT TRIP CB R6 22 12 TEST
T3 R6 ELECTRONIC CONTROL
NOTE AF OUTPUTS
F13 32 a 4 23 GROUP
SH
PR1
10 4 MODULE 19
C 32
50 3 SPARE FAULT INPUT LED #5
LOW FUEL LEVEL SHUTDOWN
36 2
52 152 52 52 12 A 20 4 SPARE FAULT INPUT LED #6
CT 3 53 3 6 7 H1 T4 J1-5 95 67O RDM 12 TEST
5 R2 34 C
BK BR R2 5 SPARE FAULT INPUT LED #7
PR1
10 B OUTPUTS 68
62O LFSR 35 13 SILENCE
86 6 SPARE FAULT INPUT LED #8
6
NOTE BD 9 39 69 30
6 14 HORN
BK PU -7
LFSR
ONLY FOR DVR R1 37 R1
4 7 OUTPUTS
D2 38 RELAY
53 153 53 53
DROOP 8 9 H1 T5 J1-6 96 19 DRIVER
1W 6 19 7 17 17
CT D- D- LFLS 40
D1 BK BR D+ D+ 72 72 2 MODULE
19 C
PR1
LFSR RDM
50 50 50 20 8 7 A B 1 NOTE BA
J1-7 97 20 6 NOTE AM NOTE AJ
D- D-
B B
16 20 C
BK PU D+ REMOTE
D+ 3 HORN INPUT 1
J1-8 98 99 NFPA 110
T1 T2 T3 17 1+ 16 LIGHT
V W
U ATB
NOTE BG 4 HORN INPUT 2
90
VOLTAGE REGULATOR 7 7 2 DATA
RDM RDM
NOTE D 122 30
T4 T5 T6 VAR
5A 12 TEST
J 82 82 1 124
A NOTE Y
VOLTAGE ADJUST
2 13 SILENCE
6A 80 80 POTENTIOMETER 32 8 30
S B 120 CCM+ CCM-
3 CCM+ CCM+ D+ 14 HORN -7
21 C DATA +
T7 T8 T9 RFI FILTER 33 18
3
NOTE A
NOTE C
NOTE B
22
REGULATOR
60 CCM
2 1 2 3 4
C ADJUST SP1 99
1 SP1A SP1 B+
RFI
NOTES NOTE L: COMPONENTS INSTALLED ONLY WITH OPTIONAL SPACE HEATERS. NOTE V: SHUNT TRIPS ARE INSTALLED WITH EACH OPTIONAL CIRCUIT BREAKER NOTE AC: CONNECT ALARM TERMINAL POINT 7 TO POINT 6 FOR NFPA 110 ALARM MODULE OPERATION NOTE AL: "LOW FUEL ALARM" 40% DECREASING NOTE BA: OPTIONAL NFPA 110, (16) LIGHT REMOTE ANNUNCIATOR INSTALLED BY CUSTOMER NOTE BM: CONTACT WIRED WITH OPTIONAL RUPTURE BASIN ALARM.
A NOTE A: FOR VR6-B VOLTAGE REGULATOR ONLY: JUMPER TERMINALS FOR THREE PHASE SENSING,
NOTE M: COMPONENTS INSTALLED WITH EITHER THE AUTOMATIC FUEL TRANSFER SYSTEM 1 INSTALLED ON PACKAGE.
NOTE W: REMOVE THIS JUMPER WIRE IF IT IS DESIRABLE TO TURN OFF
MODE. NO CONNECTION REQUIRED FOR NFPA 99 OPERATION.
NOTE AD: TERMINALS 12, 13 & 14 ARE WIRED FROM AN OPTIONAL CUSTOM ALARM MODULE TO
NOTE AM: "CRITICAL LOW" 5% DECREASING NOTE BB: UP TO 3 ALARM MODULES WITH A COMBINED WIRE LENGTH OF 300 METERS
MAY BE DRIVEN FROM THE DATA LINK. WIRE 30 AND WIRE 99 TO BE
NOTE BN: SET TOP DIAL ON TIMER TO "E", SET MIDDLE DIAL TO "3s",
AND SET BOTTOM DIAL TO "0.7".
A
REMOVE JUMPER FOR SINGLE PHASE SENSING. OR THE AUTOMATIC FUEL TRANSFER SYSTEM 3 OPTIONS.
TERMINALS 12, 13 & 14 RESPECTIVELY, OF THE FIRST ALARM MODULE WHEN ORDERED NOTE AN: COMPONENTS INSTALLED FOR OPTIONAL FUEL TRANSFER SYSTEM #1.
THE GSC AND ALARM VIA THE ENGINE CONTROL SWITCH (ECS) "OFF" MINIMUM WIRE SIZE 12 AWG. ALL OTHER WIRES TO BE MINIMUM 16 AWG.
NOTE B: FOR VR6-B VOLTAGE REGULATOR ONLY: INSTALL JUMPER FOR 1:1 V/HZ SLOPE, NOTE N: COMPONENTS INSTALLED WITH OPTIONAL UL BATTERY CHARGER. POSITION IN ORDER TO LIMIT BATTERY DRAIN. IN ADDITION TO EITHER AN NFPA 99, NFPA 110 OR CUSTOM ALARM MODULE. NOTE AP: COMPONENTS INSTALLED FOR OPTIONAL FUEL TRANSFER SYSTEM #2.
NOTE BC: COMPONENTS INSTALLED WITH MANUAL SYNCHRONIZING OPTION.
REMOVE FOR 2:1 V/HZ UNDERFREQUENCY SLOPE. (STANDARD IS TO REMOVE JUMPER) UL BATTERY CHARGERS WIRED 120 VAC. NOTE AQ: COMPONENTS INSTALLED FOR OPTIONAL FUEL TRANSFER SYSTEM #3.
NOTE X: SEE GSC RELAY RATING CHART. NOTE AE: COMPONENTS INSTALLED WITH OPTIONAL GENERATOR WINDING OVERTEMPERATURE RELAY. SEE SLR TABLE FOR RESISTOR CONNECTIONS.
NOTE C: FOR VR6-B VOLTAGE REGULATOR ONLY: REMOVE JUMPER WHEN VOLTS ADJUST POT FITTED. NOTE P: COMPONENTS INSTALLED WITH OPTIONAL NON-UL BATTERY CHARGERS. ALARM OVERTEMPERATURE FACTORY SET TO 130°C FOR PRIME POWER, 160°C FOR STANDBY POWER. NOTE AR: OPTIONAL AUXILLIARY CIRCUIT BREAKER CONTACTS RATED FOR
NOTE Y: CUSTOMER COMMUNICATION MODULE INSTALLED BY CUSTOMER. WIRES 2 & 99 MUST 6 AMPS AT 240/480VAC, 50/60HZ; 3 AMPS AT 600VAC, 50/60HZ; NOTE BD: COMPONENTS INSTALLED ONLY WITH LOADSHARE OPTION.
IEC BATTERY CHARGERS WIRED 240 VAC. FUSE F15 IS A 6 AMP FUSE SHUTDOWN OVERTEMPERATURE FACTORY SET TO 135°C FOR PRIME POWER, 165°C FOR STANDBY POWER.
NOTE D: REFER TO THE VOLTAGE REGULATOR TERMINAL CHART TO DETERMINE THE ACTUAL BE A MINIMUM OF 16 AWG SHIELDED TWISTED PAIR CABLE. MAXIMUM DATA AND BATTERY 2.5 AMPS AT 48VDC; 0.8 AMPS AT 125VDC; 0.3 AMPS AT 250VDC: NOTE BE: LOADSHARING LINES ARE COMMON TO ALL UNITS.
SUPPLIED WITH 5 AMP BATTERY CHARGER. FUSE F15 IS A 10 AMP FUSE NOTE AF: COMPONENTS INSTALLED WITH OPTIONAL GENERATOR BEARING OVERTEMPERATURE RELAY
DESIGNATION FOR THE SPECIFIC VOLTAGE REGULATOR. WIRE LENGTH IS 457 METERS, INCLUDING RUNS BETWEEN MULTIPLE GENSETS.
SUPPLIED WITH 10 AMP BATTERY CHARGER. NOTE AS: "PUMP OFF" 90% INCREASING NOTE BF: REFER TO GOVERNOR TERMINAL CHART TO DETERMINE THE ACTUAL TERMINAL
ALARM OVERTEMPERATURE FACTORY SET TO 70°C.
NOTE E: COMPONENTS INSTALLED WITH THE GROUND FAULT RELAY OPTION. NOT AVAILABLE NOTE Z: COMPONENTS INSTALLED WITH OPTIONAL ENGINE MONITORING SYSTEM. DESIGNATION FOR SPECIFIC GOVERNORS.
NOTE Q: COMPONENTS INSTALLED WITH ANY COMBINATION OF THE SPACE HEATER, SHUTDOWN OVERTEMPERATURE FACTORY SET TO 90°C. NOTE AT: "PUMP ON" 50% DECREASING
WITH OPTIONAL DELTA CONNECTED GENERATORS. NOTE AA: COMPONENT INSTALLED FOR NFPA 99 OR NFPA 110 ALARM MODULE. SWITCHED INPUT NOTE BG: COMPONENTS INSTALLED WITH OPTIONAL ENCLOSURE LIGHTING
BATTERY CHARGERS, JACKET WATER HEATER, OR BLOCK HEATER OPTIONS. NOTE AU: CUSTOMER INTERFACE MODULE INSTALLED BY CUSTOMER.
NOTE F: OPTIONAL RFI FILTER INSTALLED ONLY WITH VR6-B REGULATOR TERMINALS 10 AND 11 ON THE ALARM MODULE MUST BE JUMPERED TO TERMINALS NOTE AG: THE INPUT TO THE GSC SPARE SHUTDOWN INPUTS MUST BE A B- SIGNAL
NOTE AV: OPTIONAL CUSTOM (8) LIGHT REMOTE ANNUNCIATOR INSTALLED BY CUSTOMER. NOTE BH: FOR VR6-B VOLTAGE REGULATOR ONLY: REMOVE JUMPERS BETWEEN:
NOTE R: COMPONENTS INSTALLED WITH OPTIONAL GENERATOR RUNNING RELAY. 3 AND 4 RESPECTIVELY, IF IT IS DESIRED TO SOUND HORN IN CONJUNCTION WITH APPLIED FOR 250mSEC OR LONGER TO ASSURE PROPER OPERATION. CUSTOMER
NOTE G: OPTIONAL PM CONNECTIONS. STANDARD SE GENERATORS REQUIRE NO CONNECTIONS.
NOTE S: EMERGENCY STOP PUSHBUTTON INSTALLED WITH OPTIONAL PACKAGE ENCLOSURE. FLASHING LAMP. PROVIDED SWITCH TO BE RATED FOR 4mA, 12VDC OPERATION. NOTE AW: OPTIONAL NFPA 99, (8) LIGHT REMOTE ANNUNCIATOR INSTALLED BY CUSTOMER.
TERMINALS 20 & 28, 22 & 30, AND 24 & 26 FOR OPTIONAL PM GENERATORS.
THIS SCHEMATIC IS FOR THE 3456 GENERATOR SET with EMCP II
NOTE H: 24VDC POWER SUPPLIED ONLY WITH OPTIONAL DIGITAL VOLTAGE REGULATOR. NOTE AH: CONTACT WIRED WITH OPTIONAL LOW FUEL LEVEL ALARM. NOTE BJ: COMPONENTS INSTALLED ONLY WITH 120 VAC BLOCK HEATER OPTION.
NOTE J: PF/KVAR ADJUSTABLE POTENTIOMETER ONLY AVAILABLE WITH DVR WITH PF/KVAR CONTROL.
JUMPERS BETWEEN 4 & 34 AND 45 & 46 ARE REMOVED WITH THIS OPTION.
NOTE T: COMPONENTS INSTALLED WITH OPTIONAL ETHER START AID.
NOTE AB: COMPONENT INSTALLED FOR OPTIONAL CUSTOM ALARM MODULE. MODULE CONTAINS
SPARE INPUTS FOR CUSTOMER DESIRED USE WITH CUSTOMER PROVIDED SWITCH. NOTE AJ: LOW FUEL LEVEL SHUTDOWN WIRED WHEN OPTIONAL FUEL TANK BASE IS ORDERED.
NOTE AX: OPTIONAL NFPA 110, (2) LIGHT REMOTE ANNUNCIATOR INSTALLED BY CUSTOMER.
NOTE BK: COMPONENTS INSTALLED ONLY WITH 240 VAC BLOCK HEATER OPTION.
VOLUME 1 of 2: DESCRIPTION
NOTE AY: OPTIONAL CUSTOM (16) LIGHT REMOTE ANNUNCIATOR INSTALLED BY CUSTOMER
NOTE K: COMPONENTS INSTALLED ONLY WITH JACKET WATER HEATER OPTION. NOTE U: COMPONENTS INSTALLED WITH OPTIONAL COMMON ALARM RELAY.
(RATED FOR 4mA, 12 VDC OPERATION) NOTE AK: TERMINAL 23 OF REMOTE ANNUNCIATOR TO BE WIRED TO TERMINAL 14 OF THE Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
NOTE AZ: OPTIONAL NFPA 99, (16) LIGHT REMOTE ANNUNCIATOR INSTALLED BY CUSTOMER NOTE BL: COMPONENT INSTALLED ONLY WITH BATTERY DISCONNECT OPTION.
NOT USED WITH FUEL FIRED JACKET WATER HEATER. THE LOCAL ALARM MODULE. in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
8 7 6 5 4 3 2 1
ATB
GND-REAR COVER
RENR2477-02 Harness And Wire Electrical Schematic Symbols
75-CAM-3
76-CAM-4
T1-AC CONN-7
NOTE E
F11 108-TBA1-108T
July 2009
51-TBC-51 OR 51-LSGOV-4
52-TBC-52 OR 52-LSGOV-6
53-TBC-53 OR 53-LSGOV-8
Symbols
1-TBD1-1DT
1-TBD1-1CT
T2-AC CONN-5 F12
1-TBD1-1CL
GND-CHASSIS STUD
54-ECS-7
SP2-TBD1-SP2BB
7-RM-1
T3-AC CONN-9
GND-AC CONN-4
F13 110-TBA1-110T
GND-70 WAY-68
50-TBA1-GND5T
50-AC CONN-10
50-AC CONN-11
50-AC CONN-12
202-70 WAY-40
203-70 WAY-42
206-70 WAY-64
207-70 WAY-36
101-70 WAY-14
131-70 WAY-70
136-70 WAY-38
137-70 WAY-66
157-70 WAY-23
159-70 WAY-51
T0-AC CONN-8
51-AC CONN-1
52-AC CONN-2
53-AC CONN-3
50-TBA1-50AT
87-TBD1-87T
136-TBA1-136T
206-PSPB-2A
207-PSPB-1A
L1 L1
13-RM-15
202-PRL-X1
131-PSL-X2
203-PSL-X1
50-TBC-50
86-CAM-6
136-CR-2
137-CR-8
157-SS-4
159-SS-6
88-TBD1-88T
108-F11
110-F13
TBC
59-TBD1-59T
1-TBD1-1AL
43-SP-1
44-SP-2
42-SP-3
T
+
~ A1 B1 15
50-TBA1-50BT 50 Pressure Temperature Level Flow Circuit Breaker
EPIR 6
3 2
5 4
1
TDR 6
3
5
2
4
1
6
3 2
5 4
1
51-TBA1-51T
OR 151-LSGOV-5
51
Symbol Symbol Symbol Symbol Symbol
61
A
52-TBA1-52T
OR 152-LSGOV-7 52 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T
F15 F23
FSM3U
Symbols and Definitions
AB
D2
D3
CR 1mn
GRR LFSR 53-TBA1-53T 53
OR 153-LSGOV-9
L1
TBA1
.8
1.
.6 t
L3
0
0
B A B A B A
.4
3 2 1
Fuse: A component in an electrical circuit that will open the circuit if too much current flows
.2
U1 U1 NOTE D 80
9 8 7 16 18 A2 ~
-
9 8 7 9 8 7 B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B
CATERPILLAR through it.
36-70 WAY-49
211-PSPB-1B
OR 84-70 WAY-4
82
SP2-TBD1-SP2BT
SP2-TBD1-SP2BT
2-CR-B
89-TBD1-89T
38-TBD1-38B
-B S D +B
2-GRR-B
2-TBD1-2AB
2-LFSR-B
3-TBD1-3B
137-TBA1-137T
39-RM-24
2-CR-B
30-LFSR-7
30-LFSR-9
30-TBD1-30DB
72-70 WAY-17
L2 L2
30-TBD1-30DT
5-TBD1-5AB
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The
2-TBD1-2AL
8-ECM-21
101
GND5
GND6
206
207
202
203
131
108
109
157
136
137
110
159
T0
51
50
50
50
52
53
circle indicates that the component has screw terminals and a wire can be disconnected from it.
91-GSC-10
92-GSC-11
93-GSC-12
94-GSC-4
95-GSC-5
96-GSC-6
97-GSC-16
98-GSC-17
75-ATR-7
76-BTR-7
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
L L
No circle indicates that the wire cannot be disconnected from the component.
S-SPD-ECM-10
D-SPD-ECM-12
30-TBD1-30CT
10-PLS-3
Ground (Wired): This indicates that the component is connected to a grounded wire. The
grounded wire is fastened to the machine.
108-SLR1
110-SLR2
30-PWM-B(-) OR 30-LSGOV-16
Ground (Case): This indicates that the component does not have a wire connected to ground.
CHASSIS STUD It is grounded by being fastened to the machine.
GND-CHASSIS STUD
HC4-EMSII CONN-16
HC1-EMSII CONN-3
SV-EMSII CONN-24
CCM(+)-70 WAY-32
CCM(-)-70 WAY-33
ER-EMSII CONN-8
GND-DOOR STUD
2-EMSII CONN-31
2-EMSII CONN-12
2-EMSII CONN-22
45A-DC CONN1-5
19-DC CONN1-11
20-DC CONN2-10
62-DC CONN1-10
67-DC CONN1-12
2-EMSII CONN-2
2-EMSII CONN-6
GND-70 WAY-47
45-DC CONN1-4
10-DC CONN2-8
18-DC CONN1-8
30-DC CONN2-4
59-DC CONN2-3
62-DC CONN1-7
67-DC CONN1-9
2-DC CONN2-11
2-DC CONN2-12
CCM(+)-GSC-21
D(+)-70 WAY-19
SP1-70 WAY-60
SP2-70 WAY-61
SP3-70 WAY-62
GND-GSC-GND
CCM(-)-GSC-22
2-TBD1-GND1T
D(-)-70 WAY-20
1-DC CONN2-1
1-DC CONN2-2
4-DC CONN2-6
10-70 WAY-45
30-70 WAY-16
57-70 WAY-30
99-70 WAY-35
87-70 WAY-57
88-70 WAY-58
89-70 WAY-59
SP1A-GSC-23
46-ESPB-1R1
20-ESPB-1R2
MPU-SHIELD
34-ESPB-1L2
17-ESPB-1L3
30-ESPB-1L4
5-70 WAY-48
63-70 WAY-6
90-70 WAY-5
VAR-SHIELD
2-70 WAY-15
D(+)-GSC-19
SP2-GSC-24
SP3-GSC-25
SP2-LFSR-4
2-TBD1-2DT
D(-)-GSC-20
6-70 WAY-2
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the
3-70 WAY-3
59-EPIR-87
SP2-D3-U2
17-GSC-38
18-GSC-13
57-GSC-33
62-GSC-31
63-GSC-36
90-GSC-35
SP2-D2-U2
30-TDR-A2
30-LFSR-7
38-GRR-A
ES-SAS-3
87-GRR-4
88-GRR-1
89-GRR-7
67-GSC-9
21-GSC-1
22-GSC-2
10-RM-39
30-RM-28
38-RM-16
5-TDR-16
30-ECS-1
57-ECS-4
80-VAR-3
82-VAR-1
37-RM-19
20-SAS-2
10-PLS-3
20-RM14
1-RM-30
1-RM-36
6-RM-22
2-RM-27
99-RM-9
1-ECS-6
2-SCS-2
5-ECS-9
1-F15-T
1-F23-T
2-PL2-1
2-PL1-1
1-RM-2
2-CR-B
3-CR-9
contacts of a normally open reed switch; it opens the contacts of a normally closed reed switch.
GND-TBA1-GND6B
GND-REAR COVER
Sender: A component that is used with a temperature or pressure gauge. The sender
measures the temperature or pressure. Its resistance changes to give an indication to
Electrical System
T
TBD1 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T the gauge of the temperature or pressure.
CHASSIS STUD
CCM+
GND2
HC1
GND3
GND4
BO
MT
SP1A
ER
HC4
CCM-
ES
SP1
FP
SP2
SP2
SP3
SP4
D+
10
10
EL
17
18
19
SV
SV
SV
SV
45A
21
20
20
30
30
30
30
46
45
34
37
38
57
57
59
62
62
63
80
90
22
82
87
88
89
67
67
99
D-
1
1
1
1
2
2
2
2
2
2
2
5
5
2
coil that makes an electromagnet when current flows through it. The electromagnet
CBX1-UP can open or close a valve or move a piece of metal that can do work.
L L L L L L L L L L L L L L L L L L L L L L L L L L L L 8AZ1-UP Magnetic Latch Solenoid: A magnetic latch solenoid is an electrical component that is
activated by electricity and held latched by a permanent magnet. It has two coils (latch and unlatch)
that make electromagnet when current flows through them. It also has an internal switch that places
1-EPIR-30
1-TDR-A1
1-TBD1-5AL
2-EPIR-85
2-TBD1-2EL
1-TBD1-1DL
46-TBD1-45L
46-TBD11-46L
4-TBD1-34L
4-TBD1-4L
10-EMSII CONN-1
20-LSGOV-20
D(+)-EMSII-5
SP1A-TBD1-SP1AL
SP1A-TBD1-SP1L
30-TBD1-GND2L
90-ALM-2
D(-)-EMSII-14
21-MPU-1
30-TBD1-30DL
22-MPU-2
82-VR6B-7
OR 82-DVR-7
80-VR6B-6A
OR 80-DVR-45
2-TBD1-2DL
ET(-)-EMT-B
ET(+)-EMT-A
ET-EMT-C
ES-ECM-38
BODY STUD
the latch coil circuit open at the time the coil latches.
D(+)-TBD1-D(+)B
D(-)-TBD1-D(-)B
The "C" stands for "Connector" and the
207-TBA1-207B
203-TBA1-203B
157-TBA1-157B
101-TBA1-101B
OR 84-PRPB-3
57-TBD1-57BB
30-TBD1-30AT
Codes (see sample).
RDM-GSC-30
90-TBD1-90B
63-TBD1-63B
2-TBD1-2BT
number indicates which connector in the
81-PRPB-4
72-LFSR-A
6-TBD1-6B
3-TBD1-3T
71-CAM-9
74-CAM-8
67-TBD1-67AB
62-TBD1-62AB
20-TBD1-20AB
50-TBA1-50CB
67-TBD1-67AT
62-TBD1-62AT
10-TBD1-10BT
50-TBA1-50BB
50-TBA1-50AB
84-F23-B
18-TBD1-18B
T0-TBA1-T0T
AG-C4 L-C12 harness (C1, C2, C3, ...).
2-TBD1-2BB
2-TBD1-2AT
19-TBD-19B
L-C12
111-7898 3E-5179
T3-F13
T1-F11
3E-5179
Part Number: for Connector Plug 1
Part Number: for Connector Receptacle
12 11 10 9 8 7 12 11 10 9 8 7 12 11 10 9 8 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 2
AC CONN 15 16 17 18 19 20 21 22 23 24 25 26 27 28
DC CONN 1 DC CONN 2
70 WAY Plug Receptacle
(BLACK) (GREY) (GREEN)
29 30 31 32 33 34 35 36 37 38 39 40 41 42 Pin or Socket Number
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
5A
43 44 45 46 47 48 49 50 51 52 53 54 55 56
1 Deutsch connector: Typical representation
Component
of a Deutsch connector. The plug contains all Fuse (5 Amps) 9X-1123 Part Number
57 58 59 60 61 62 63 64 65 66 67 68 69 70 2 sockets and the receptacle contains all pins.
41-RM 13
41-RM 13
45-TBD1-45T
45A-TBD1-45AT
1-TBD1-1AT
1-TBD1-1AB
59-TBD1-59B
30-TBD1-30AB
4-TBD1-4B
51-TBA1-51B
52-TBA1-52B
53-TBA1-53B
GND-TBA1-GND5B
T2-F12
325-AG135 PK-14
1 Sure-Seal connector: Typical representation Harness identification code:
of a Sure-Seal connector. The plug and receptacle Wire Gauge
87-TBD1-87B
88-TBD1-88B
10-TBD1-10AB
89-TBD1-89B
CCM(+)-TBD1-CCM(+)B
SP1-TBD1-SP1B
GND-TBD1-GND1B
SP2-TBD1-SP2AB
CCM(-)-TBD1-CCM(-)B
SP3-TBD1-SP3B
5-TBD1-5AT
36-F15-B
206-TBA1-206B
99-TBD1-99B
136-TBA1-136B
159-TBA1-159B
137-TBA1-137B
202-TBA1-202B
GND-TBA1-GND6T
131-TBA1-131B
This example indicates wire group 325,
2 contain both pins and sockets. wire 135 in harness "AG". Wire Color
Volume 2 of 2: Control Panel and Marshalling Box
NOTE D
5-TBD1-5BT
30-TBD1-30BT
5-ECS-10
54-TDR-B1
RENR2477-02 VOL 2 of 2
0 Data valid but above normal operational range.
5-ECS-8
39 29 19 9
5-ECS-10
10-TBD1-10AT
34-TBD1-34B
5-ECS-9
1-TBD1-1BB
ALM CAM
20-TBD1-20BT
1-TBD1-1BT
57-TBD1-57AT
30-TBD1-30CB
ER-TBD1-ERT
10-ALM-1
18
-
38 28 8
14-RM-18
1-TBD1-1DB
1-TBD1-1CB
56-GSC-40
2 Data erratic, intermittent, or incorrect.
7-TDR-15
37 27 17 7
55-GSC-39
S-SPD-ECM-10
20 F4
30-TBD1-30CT
20-TBD1-20BL
60-CAM-12 12 5 60-ALM-12 12 5 ECS
CLR-MCS-6 33 23 13 3 HC1-TBD1-HC1T 9 Abnormal update.
21 34 F5 7 DOOR STUD 2-TBD1-2GT
70-70 WAY-44 11 4 70-70 WAY-44 11 4 76-D3-L2
10 Abnormal rate of change.
10-PLS-3
6-TBD1-6T 22 35 F6 8 32 22 12 2 2-TBD1-2ET
44-SP-2
43-SP-1
42-SP-3
10 3 73-GNDFR-14 10 3 75-D2-L2
2-TBD1-2FB
23 36 F7 9 11 Failure mode not identifiable.
9 2 90-TBD1-90L 71-70 WAY-1 9 2 2-TBD1-2EB 31 21 11 1 10-TBD1-10BL
39-CR-A 24 37 F8 10 10-CAM-1
8 1 74-70 WAY-21 8 1 10-ALM-1 12 Bad device or component.
25 38 F9 11 10-RM-39
GND-TBD1-GND4T
SP-SHIELD
CLR-MCS-6 4 1 2-SCS-2
OR 44-LSGOV-27
OR 42-LSGOV-26
OR 43-LSGOV-28
30-ALM-7
OR 10-LSGOV-15
SCS SRV-MCS-3
NOTE A
10-TBD1-10BB
10-PWM-B(+)
3 SRV-CAT MONITORING
42-PWM-1
44-PWM-2
43-PWM-3
SYSTEM CONN-23
2 2-MCS-2 15 16 17 18 19 20 21 22 23 24 25 26 27 28
82-TBD1-82B
80-TBD1-80B
159-TBA1-159T
157-TBA1-157T
110-TBA1-110L
108-TBA1-108L
1 2-TBD1-2FT
WOODWAR D
PART NO. REV.
WOODWAR D
SERIAL NO.
3 LOAD
SHARING
VAR R
SP 3
2
1
PLS 3
2
1
MODULE
94-ATB J1-4
95-ATB J1-5
96-ATB J1-6
3 2 1
9-PL1-2
9-PL2-2
0 10 0 10
10 = 10 AWG
WARNING
160
161
1 2 3 4 5 6
91-ATB J1-1 100 Pressure Sensor (Engine Oil)
D
122-TBA2-122U
120-TBA2-120U
124-TBA2-122U
SLM
51-TBA1-51T
52-TBA1-52T
53-TBA1-53T
152-TBC-52
151-TBC-51
153-TBC-53
19 20 21 22 NOTE E: SET TOP DIAL ON TIMER TO "E", SET MIDDLE DIAL TO "3s",
D(+)-TBD1-D(+)T CCM(-)-TBD1-CCM(-)T
CCM(+)-TBD1-CCM(+)T AND SET BOTTOM DIAL TO "0.7". 248 CAT Data Link
20 Page,
SP2-TBD1-SP2AT
23 24 25 26 27 28
REAR COVER
268 EMCP Electronic Control (Generator Set)
SP1A-TBD1-SP1AB
20-TBD1-20BB
203-TBA1-203T
202-TBA1-202T
207-TBA1-207T
206-TBA1-206T
81-70 WAY-18
84--70 WAY-4
131-TBA1-131T
SP3-TBD1-SP3T 58-ECS-5
84-PSPB-2B
131-PSL-X2
32 33 34 GND-TOP COVER
ES-TBD1-ES
29 30 31 SLR CHART
84-PRPB-3
GND-CHASSIS STUD
RDM-70 WAY-7 57-TBD1-57AB
62-TBD1-62BB SYNCHRONIZING
35 36 37 38 39 40 VOLT LINE 334 Spare Output
90-TBD1-90T RESISTOR TAP
TO LINE
1
SETTING CHART 336 Switch (Engine Control)
1600 OHM
63-TBD1-63T PSL PRL 208 USE E-D 1760 OHM 441 Electronic Governor Relay
X1 X2 2 X1 X2 A
SAS
17-TBD1-17B
55-ECS-2
56-ECS-3
1A NC 2A 3 NO 4 B
442 Generator Fault Relay
3
1B NC 2B 300 USE E-B 5600 OHM
443 Crank Termination Relay
PSPB PRPB C
380 USE E-B 5600 OHM REAR SUB PANEL 444 Starting Motor Relay
640 OHM
C
D
A
B
GND-TBD2-GNDT
GND-DC CONN-21
5-KWR-B
DC CHASSIS STUD
5-DC CONN-22
B
TBD2
5
70-DC CONN-36
70-LFLS-5
B
70
GND-DC CHASSIS STUD
T
B
GDN-PANEL GND GND
U
B
83-LFLS-2 83 83-PR-A
2-TBC-2T 2-BTR-E
T
B
U
2-PR-B 2 2-ATR1-E
U
B
30-TBD2-30BB 85-MV-2 85 85-PR-5 2-DVR-(B-)
T
B
30-BTR-5
U
2-DC CONN-35 2 2-MV-1
U
B
77-FRBS-1 77 77-TBD2-SP3T 2-ALR-B
71-TBD2-71T
T
B
2-BC-(-) 2
1 2 3 4
3-TBD2-3U
3-DC C0NN-3 3-BTR-D
T
B
30-BTR-1 2-TBD2-2AU
U
3-TBC-3T 3 3-ATR1-D
read
set point
adjust
9
9
T
B
@ 76-D3-L2 6-TBC-6T 6
30-ATR1-5
74-TBD2-74T 10-DC CONN-12
T
B
U
A B C D E F G H I J
1 2 3 4
30-ATR1-1 3-ATR2-D
T
B
U
10-DVR-B(+) 10
30-ATR2-1 2-TBD2-2AU
2-ATR2-E 30B-DC CONN-15
read
set point
adjust
@ 75-D2-L2
T
B
30-TBC-30T
U
75-ATR2-7 30 30-LFLS-6
30-GNDFR-11
T
30-ATR1-1
B
U
30-BTR-1
30 30-FRBS-2
163-BT1-RD
A B C D E F G H I J
164-BT1-WH 36-BC-(+)
T
B
36-DC CONN-11
36
71-BTR-3
K L M N O P Q R S
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
T
B
71-DC CONN-16
71
BTR
T
B
72-DC CONN-17
U
72 72-LFLS-7
171-TC4-WH 74-ATR1-3
T
B
K L M N O P Q R S
81-DC CONN-9 81 81-LFLS-1
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
ATR1
T
B
81-LFLS-4
U
81
84-PR-7
T
B
U
DC CHASSIS
30-ATR3-5 74-ATR1-3
5-TBD2-5T
74-ATR3-3 3-ATR1-D
74-ATR2-3
1 2 3 4
30-ATR2-1 3-ATR3-D
1 2 3 4
3-ATR2-D
30-ATR3-1 2-ATR1-E
30-ATR3-1 2-ATR2-E 2-ATR3-E
read
set point
adjust
9
3
6
75-ATR1-7
read
set point
adjust
75-ATR3-7
75-ATR2-7
2
8
5
A B C D E F G H I J
A B C D E F G H I J
KWR
7
1
4
49-TBC-49T
A
48-TBC-48T
K L M N O P Q R S
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
K L M N O P Q R S
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
ATR2
2-TBD2-2CT
8
8
ATR3
9
3
6
B
2
8
5
ALR
F
D(-)-TBC-D(-)B
G
5A-DVR-5
64-TBC-64T
7
1
4
E
A
22-GEN 66-TBC-66T
22
22
22-VR6B-22
A
ATA(-)-TBC-ATA(-)B D(+)-TBC-D(+)B
H
D2
6-TBC-6B 65-TBC-65T
C
24-GEN
24
24
24-VR6B-24
NOTE C
B
ATA(+)-TBC-ATA(+)B 10-TBC-10B
RFI FILTER
20-GEN
20
20
20-VR6B-20 2-TBD2-2AB
D1
SERVICE CONNECTOR
205-OL-95
2-TBC-2AB
9
3
6
206-TBA2-206T
DROOP RESISTOR
85-TBD2-85B
2
8
5
84-PR-7
PR
275-DVR-45
6A-DVR-6
3
2
DC CHASSIS
84-TBD2-84T
1
81-TBD2-81T
7
1
4
PF/KVAR
84-PR-8
276-DVR-44
MARSHALLING BOX
83-TBD2-83T
120-F50-B
122-F51-B
124-F52-B
5A-DROOP-D2
6A-DROOP-D1
T
B
3
10-TBD2-10U
T
B
31
32
33
34
35
36
37
38
39
40
SP4
2-TBD2-2BT SP4-DC CONN-34
J1
20-GEN
7
7
21
22
23
24
25
26
27
28
29
30
22-GEN
NOTE E
24-GEN
40 41 42 43 5
26-GEN PM
DVR
11
12
13
14
15
16
17
18
19
20
6
28-GEN PM
7
(40 WAY)
30-GEN PM
2
3
4
5
6
7
8
9
1
AC CONN
10
46 47 48 49 50
44 45
B+ B- 20 22 24 26 28 30 F1 F2
F2-GEN FIELD LEAD
157-TBA2-157B
202-TBA2-202B
203-TBA2-203B
207-TBA2-207B
159-TBA2-159B
136-TBA2-136B
137-TBA2-137B
275-PF/KVAR-3
276-PF/KVAR-1
80-TBD1-80L @
82-TBD1-82L @
GND-TBC-GNDT
GND-TBA2-GND1B
GND-TBD2-GNDB
PANEL GND
8
@
14
10
120-F50-B
122-F51-B
124-F52-B
2
WIRE NO.
DEVICE ABBREVIATION
= 8 AWG
= 14 AWG
= 10 AWG
NOTE G
WIRING EXAMPLE
5-TBD2-5B
SP4-TBD2-SP4B
SP3-TBD2-SP3B
2-TBD2-2BB
70-TBD2-70B
87-TBC-87T
88-TBC-88T
89-TBC-89T
74-TBD2-74B
99-TBC-99T
57-TBC-57T
NOTE C
DEVICE TERMINAL NUMBER
20-GEN-20 OR 20-RFI-20
22-GEN-22 OR 22-RFI-22
A STANDARD SE GENERATOR.
24-GEN-24 OR 24-RFI-24
31
32
33
34
35
36
37
38
39
40
26-GEN PM 5A-DROOP CT
2 - TBD1 - 2 F T
21
22
23
24
25
26
27
28
29
30
(40 WAY)
DC CONN
U=UPPER
(IF REQUIRED)
B=BOTTOM
2
3
4
5
6
7
8
9
6
6
1
10
= COMPONENT LOCATED ON ENGINE OR BASE
INSULATION WIRE UNLESS OTHERWISE INDICATED.
(IF REQUIRED)
NOTE D: WIRES 5A AND 6A AR TO BE SOLDERED TO RESISTOR.
WIRES 2, 3, AND 30 FROM ATR2 TO BTR AS INDICATED.
= COMPONENT LOCATED IN THE CONTROL PANEL
36-TBD2-36B
THE SECOND BLOCK,...,'F'
SPECIFIC TERMINAL BLOCK
6-TBD2-6T
3-TBD2-3T
TERMINAL CONNECTION POINT
61-TBC-61T
90-TBC-90T
63-TBC-63T
10-TBD2-10T
71-TBD2-71B
72-TBD2-72B
81-TBD2-81B
84-TBD2-84B
D(-)-TBC-D(-)T
30-TBD2-30AT
D(+)-TBC-D(+)T
SP1-TBD2-SP1B
SP2-TBD2-SP2B
RDM-TBC-RDMT
CCM(-)-TBC-CCM(-)T
CCM(+)-TBC-CCM(+)T
GND-TBA2-GND1T
GND-AC CONN-21
TBA2
AC CHASSIS STUD
101
132-F17-T
T
B
GND-PANEL GND
9
3
6
GND B T
T
B
109
2 2-TBD2-2AT 135-HC-1
B T 132-F16-T
T
B
110
F17
2-SERVICE CONN-B
2-SHUNT TRIP1-C1
2
8
5
2-SHUNT TRIP3-C1 U 2 B T
AR
C60N
OFF
3-GNDFR-A1
2
MCB1
6-TBD2-6B
7
1
4
6 B T 118-GNDFR-A1
6-ALR-A 132-TBA2-132AB
208-PC-1
5
5
B T
B
157-F32-B 157
57-DC CONN-30 157-AC CONN-11
57 B T 157-TBA2-157T 154-TBC-154T
F32
T
B
159-F33-B 159
A1
M+
202
A2
63 B T 120-TBA2-120B
203-PC-62
T
B
120-AR-B 203
87-DC CONN-31 203-AC CONN-3
120V AC OPTIONS
87 B T EF1-TBA2-EF1B
T
B
206-PR-9 206
88-DC CONN-32
(K) (L)
88 B T 206-AC CONN-24
EF2-TBA2-EF2B
T
207-F22-B
B
132-F16-T
B
90 B T 132-F21-T
GNDFR
99-DC CONN-38 8
21
11
99 B T 132-TBC-132B 132
30-TBD2-30BT
D(+)-DC CONN-19 10 132-MCB1-1
22
12
139
4
3
B T ATA(-)-ADEM-32
ATA-
ATA(-)-SERVICE CONN-H
B T RDM-DC CONN-7
RDM
6
5
AC CHASSIS
A2
131-TBA2-131BB 8 GND-TBC-GNDB 10
OR GND-BLH
AC TERMINALS
49 B T 49-KWR-4
MARSHALLING BOX
T
B
GND-BC-GND GND
231A B T CB1-AUX-12
140-BC-L 140-SPH-H1
T
B
U
140-HC-2 140
232A B T CB1-AUX-11 140-SPH-H3
T
U
T
U
CB3-AUX-11 209-TBA2-209B
T
U
120-GNDFR-A2
131-TBA2-131AT 122-F51-T
54
53
97
B T CB3-AUX-14
T
U
122-AR-A
5
210-TBA2-210B 131-PC-A2
62
61
PC
95
B T 64-ALR-4
OL
64 205-PR-6
T
U
6
13
B T 65-ALR-1 131-PC-3
96
14
65
66 B T 66-ALR-7
T
U
207-PC-53
132 132-TBA2-132BT 8
131 131-TBA2-131BT 8
133 133-TBA2-133BT 10
NOTE: This Terminal Block is common for both 120V AC and 240V AC Options.
GND GND-TBA2-GNDAT
DC TERMINALS
GND
154 B T 154-F32-T
3
3
156-F33-T
156 B T
GND-TBA2-GND1T
GND-AC CONN-21
TBA2
AC CHASSIS STUD
GND-PANEL GND
120-GNDFR-A2 101-AC CONN-38
T
B
101
135-HC-1 132-F16-T
T
B
108
141-HC-A2
9
3
6
B
T
B
133-TBA2-133AT 109
141-HC-3
F17 F18
T
B
110
2
8
5
138-HC-5 132-TBA2-132BB
AR
F19
133 133-TBA2-131BT
138-HC-7 133-TBA2-133BB
7
1
4
118-GNDFR-A1
F20
TBC
136-F16-B
T
B
136
136-AC CONN-17
multi 9
C60N
122-TBA2-122B
OFF
14 138-HC-5 132-TBA2-132BB 14
MERLIN GERIN
T
B
137-AC CONN-19
157-F32-B
T
B
157
OFF
MCB1
T
B
159-F33-B 159
A1
M+
202
240V AC OPTIONS
132-F22-T
A2
M-
202-AC CONN-1
120-TBA2-120B
203-PC-62
T
B
EF1-TBA2-EF1B
T
B
206-PR-9 206
(K) (L)
206-AC CONN-24
EF2-TBA2-EF2B
T
B
207-AC CONN-5
T
132-F16-T
B
132
T/R
T/R
132-F21-T
GNDFR
157-TBA2-157T 154-TBC-154T
F32
21
11
8 132-TBC-132B 132
30-TBD2-30BT
14 132-MCB1-1
22
12
159-TBA2-159T 156-TBC-156T
2
2
F33
131
24
131-PC-A2
14
140-TBA2-140B 137-TBA2-137T
14
A1
OR 139-BLH
142-TBA2-142B 141-F18-B
6
5
OR 138-F19-B
8
7
A2
GND 14
HC
134-MCB1-4 14
T
B
GND
OR 134-F20-B 207-PC-61
140-BC-L
T
B
U
142 142-SPH-H4
204-OL-96
98
209-TBA2-209B
T
14
B
U
212-F24-B
54
53
97
14
T
U
210-TBA2-210B
NOTE F
62
61
PC
95
OL
205-PR-6
T
B
EF1-GNDFR-K EF1
A2
6
13
131-TBA2-131AT
96
14
T
B
EF2-GNDFR-L EF2
VOLUME 2 of 2: DESCRIPTION
120-F50-T
T
U
203-TBA2-203T 122-F51-T
T
U
124-F52-T
T
U
GND2 GND-PUMP-GND 14
1
1
BC
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
E
C
D
A
B