You are on page 1of 1

Check Distance B/W Site and PA.

Terrain Profile.
VoLTE_One_Pager_MoS_DriveBased Call Dragging due to HO Issue.
Tunnel Areas /Sudden Changes in RF.
Tilt Adjustment/CellRange.
Sudden Change in Poor RF--->Filter Coefficient-->to maintain average of the Sample -->Change from 4 to 6 maintain better RSRP)
Antenna height,Azimuth,Tilt,Gain,Not radiated Properly. Check HO parameters and thresholds.
LTE Border Site/ Inter Frequency Border Sites ---> Check Cell re-selection Check Neighbour HO Definitions,TAC Definition,Wrong HO Definitions.
Issue. Part of sector Power,Config Power,CRS Gain,PDCCH Power Boost.
Coverage Issue (Radio Link Failure due to Poor TX Power (Part of Sector power). Need to reporting for high VSWR (More than 1.5).
RSRP) RSRP < -116dBm VSWR is High (>1.5) / Service affecting Alarm). Long Term Recommendation : New Site Planning, Antenna Height,Antenna Gain need to change.
POOR RF CONDITION Pilot Pollution (4 or more Cells Serving the same location within the RSRP window of 5dB). Reduce Pilot Pollution.
Overshooting. Tilt Adjustment/CRS Gain/Part of sector Power, Antenna Azimuth.
Quality Issue (Poor SINR) SINR < 0dB MIMO Swap/Tx-Imbalance--->Need to Clear. To make single dominance Cell in PA Location.
Check tx2relocAllocexpiry timer values.
Check T304 timer values.
Handover Interuption Time Time between handover initiation to handover completion Check RRC Reconfiguration timer values.
Optimize Tilt, Hysteresis & Offset values, Cell Individual Offset EUtran.
AMO Feature activation.
Ping Pong HO Ping Pong HO between 2 or more cell in Same location with poor SINR HO Oscillation feature activation.
Optimize Tilt, Hystersis & Offset, Cell Individual Offset Eutran need to set to "+ve" values.
Time to trigger a3 value to be reduced.
Intra HO Delay Time Call is dragged on Same cell and time to Intra Handover is quite high. AMO Feature.
Check A5 Parameters.
A5 Thresholds value depends upon Cell Designation.
A5 Threshold1RSRPoffset (QCI-1).
Time to trigger A5.
IFHO Delay Call is dragged on Same Cell instead of IFHO in poor coverage. A5 threshold2RSRPoffset (QCI-1).
Check B2 Parameters.
B2 Thresholds value depends upon Cell Designation.
B2 Threshold1RSRPoffset (QCI-1).
Time to trigger B2.
B2 threshold2RSCPoffset.
Voice Prio.
SRVCC Delay Call is dragged on Same cell instead of SRVCC in poor LTE coverage UMTS Coverage.

HOF Cause:

Overshooting:

Overshooting from a distance beyond cell range.


In Dense urban overshooting from beyond 3rd tier (need to Check [Terrain Profile,
HANDOVER Overshooting Samples Count/Strength,Waterbodies]).
Tilt Adjustment/CRS gain/part of sector Power.
CIO make it "Negative" to delay HO.
Disable the HO relation.

PCI Conflict-:

In OSS/ERTT to check EUtrancellFDD-->PCI Conflict or check PCI conflict in MapInfo.


Change PCI.

Cell range:-

If there is a need to increase CellRange beyond 15, check whether Maximum Cell Range
feature is active.

<2.1 Delayed HO:

Check SINR (Might be its very poor)


MOS Delayed HO due to IFHO settings.
Change--->A3/a2 Offset/A5offset/Hysteresis/timeToTrigger for a3 &a5..

Poor RF:-

Both Serving and Neighbours are in poor RF.


Legend
Target Site issue :
RF/SIP Signature
Alarm/UL-RSSI/VSWR/Sleeping Cell.
HO Failure UE has not sent RRC Re-configuration Complete message H/W Issue.
Observation
UL RSSI:

Action plan If UL RSSI ( if its not due to High traffic ,report to Customer).
Change Pzeronominal PUCCH/PUSCH.
Check External Interference (Airport,Events,Repeater).
Check VSWR, Antenna not radiating Properly, Connector/feeder issue.

Alarm:

Check Service Affecting Alarm.


Soft reset/Hard Reset can help to clear Alarm.
For H/W alarm report to Customer for rectifying it.

TX Imbalance/VSWR:

In Drive Plots (Check through different Antenna Ports Signal Strength, both Antenna Signal Strength mean difference should be less than 5 dB. If its more
than 5dB then report as TX-imbalance.
Check Feeder Cable Loss/VSWR/Connector Issue.

SWAP:

Need to Clear Sector/MIMO Swap (Report to Customer to clear this swap).

Cell Down /Site Down:

Check the Site is frequently Switch on & OFF.


Check any activity is going on this site.
Check any Power Issue in this Site. (Check with Customer).

Sleeping Cells:

High No RACH Failures-->Need to do soft Reset/hard reset/Change RRU.


UL RSSi
H/W Alarm Parameters Setting:
TX-Imbalance /VSWR
Sector Swap/MIMO Swap tinactivity Timers.
Cell Down /Site Down Target site Setting (PLMN Reserved ,Cell Barred).
Sleeping Cell Power (Config, Part f sector Power).
Parameters Settings Pzeronominal PUCCH/PUSCH.
SITE ISSUE Target Site Setting. HO Parameters(A3 ,A5 & B2), Cell designation.