You are on page 1of 57

Internal

NodeB Data Configuration

V100R007
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved


 Upon completion of this course, you
will be able to:
 Master data configuration
procedure with CME
 Master procedure of NodeB data
configuration

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2


References

 《WRAN CME User Guide》

 《BTS3812E&BTS3812A Initial Configuration Guide》

 《DBS3800 Initial Configuration Guide》

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3


Chapter 1 Data Configuration Overview

Chapter 2 Configuring Physical Equipment

Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell

Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4


Data Configuration Overview
Configuration Tool CME

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5


CME for Initial Configuration in Network Commissioning
Cell Radio
Planned Radio NodeB
Parameter
data Templates
templates

Wizards of the
CME
task focused
Script is downloaded
and activated

RNS RNS
RNC RNC

NodeB NodeB

RAN

 RAN Initial Data Configuration


 Configuring data based on the RAN network planning
 Exporting configuration data files
 Loading the files to the RNC and NodeB through LMTs

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6


CME for Data Modification in Network Expansion
Cell Radio
Planned Radio NodeB
Parameter
data Templates
templates

Wizards of the
CME
task focused
Upload Script is downloaded
and activated

RNS RNS
RNC RNC

NodeB NodeB

RAN
 RAN Data Modification
 Adding/deleting/modifying a RNC WRBS
 Adding/deleting/modifying a NodeB
 Adding/deleting/modifying a cell
 Modifying algorithm setting for RNO

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7


Data Configuration Overview
Procedure of NodeB Data Configuration

Configuring
NodeB
Data

Configuring
Configuring Configuring
Physical
Transport Local cell
Equipment

Physical equipment must be configured first

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8


Chapter 1 Data Configuration Overview

Chapter 2 Configuring Physical Equipment

Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell

Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9


Configuring Physical Equipment
Procedure of Physical Equipment Configuration
Physical
Equipment
Configuration

Create
USED FOR 3812E&A NodeB USED FOR DBS3800

Add NMPT Add HBBU

Add HBBI
Add MRRU
Add Chain/Ring
Add HBOI Add Add NMON Add Add
HULP/HDLP NAOI/NDTI NEMU/GPS NPMU NCMU
Add NPMU for
Add MRRU MBBU
Add UL BB A
Resource Group
Add Add
A NPSU Battery Add NPMU
Add For MRRU
MTRU/MAFU

End
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10
Configuring Physical Equipment

 Creating NodeB

− Adding NodeB basic data


▪ The basic data includes NodeB name and
some basic NodeB data such as clock
reference source, transmission line type,
IP address, time zone, and demodulation
mode
 Note
− A NodeB name must be unique in one RNS

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11


Configuring Physical Equipment—BTS3812E/A
 Adding Boards to Baseband Subrack
 Adding boards to the baseband subrack
− The board can be NMPT,NMON,HBBI,HBOI,HULP,HDLP,NDTI or
NAOI board
 Note
− You must configure NMPT first, and configure HBBI before
configuring MTRU and MAFU. NMPT, HBBI/HBOI and NDTI/NAOI
(alternative) are mandatory

H H H H H H H H H H N N N N N N N
B B U U U U U U D D M M D A U M C
B B L L L L L L L L P P T O T O C
I I P P P P P P P P T T I I I N U

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12


Configuring Physical Equipment —BTS3812E/A
 Adding Boards to RF Subrack
− Adding boards to the RF subrack. The board can be MTRU or
MAFU board
 Note
− MTRU and MAFU have a one-to-one relationship
− You must add HBBI first before you are adding MTRU and
MAFU

MAFU0 MAFU1 MAFU2 MAFU3 MAFU4 MAFU5

MTRU0 MTRU1 MTRU2 MTRU3 MTRU4 MTRU5

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13


Configuring Physical Equipment —BTS3812E/A
 Adding UL Baseband Resource Group

− Adding a UL baseband resource group and UL process units


 Note
− Each UL baseband resource group administrates up to six cells
− Cells in the same frequency band shall be assigned in the same
UL baseband resource group

H H H H H H H H H H N N N N N N N
B B U U U U U U D D M M D A U M C
B B L L L L L L L L P P T O T O C
I I P P P P P P P P T T I I I N U

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14


Configuring Physical Equipment —BTS3812E/A

 Adding NPMU (only for BTS3812A)

− Adding an NPMU and its PSU and batteries

 Adding NCMU (only for BTS3812A)

− The NCMU is the temperature control unit of the


BTS3812A.

 Configuring NEMU (only for BTS3812E)

− The NEMU is a peripheral of the NodeB

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15


Configuring Physical Equipment ----DBS3800

 Adding HBBU

− Adding an HBBU
 Note
− You can add only one HBBU to a NodeB

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16


Configuring Physical Equipment —DBS3800
Adding MRRU Chain/Ring

− Adding an MRRU chain or ring


Chain
Note
Ring
− The MRRU chain or ring is configured
to the HBBU/HBOI CPRI ports
− Each HBBU/HBOI has three CPRI
ports Star

− The MRRU chain occupies one CPRI


port, and the MRRU ring occupies two
CPRI ports
Adding MRRU

Note
− For the data configuration of a distributed NodeB, each MRRU is
considered as a subrack. The subrack number of an MRRU must be
unique within the distributed NodeB system
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Configuring Physical Equiment
 Configuring GPS Receiver

− GPS receiver is a peripheral of the


Antenna NodeB
− It is used to locate UE
Bracket
 Adding TMA
Jumper
− Adding a TMA
TMA
Jumper  Adding RET

− Adding a RET
Feeder
Jumper
NodeB
Cabinet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18


Chapter 1 Data Configuration Overview

Chapter 2 Configuring Physical Equipment

Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell

Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19


Chapter 3 Configuring Transport

Sector 1 Configuring Transport over ATM

Sector 2 Configuring Transport over IP

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20


Configuring Transport over ATM
Iub Interface protocol over ATM

Control Plane User plane

RACH FP
FACH FP
Radio
Network NBAP
Layer
NCP CCP CCP
Transport Transport Transport Network Transport Network
Network Control Plane User Plane
Network
User Plane
Layer

ALCAP

A B C

SAAL UNI SAAL UNI AAL2 PATH

ATM
Physical Layer

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21


Configuring Transport over ATM
Iub Interface protocol
Control
Plane ALCAP

NodeB NCP
CCP 1~n
RNC

CES NCP or CCP or ALCAP or IPoA


AAL2 PATH User
Plane
CBR VBR-RT VBR-NRT NodeB RNC
AAL2Path
Iub data
Adjnode
segmentation packing

AAL1 AAL2 AAL5


IMA/UNI/STM-1

VCI-101 VPI-10

VPI-10

ATM Cell VCI-100


E1/T1/SDH(STM-1)
VCI-100

VCI-101
VPI-20

AAL Layer ATM Layer Physical Layer

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22


Configuring Transport over ATM
Procedure of Transport Configuration Transport
Configuration

Create NodeB

Add NDTI/HBBU Add NAOI

Add IMA Group Add Fractional


Add UNI LINK Add STM-1 Link
ATM

Add IMA Link Add Time Slot


Across

Add NCP/CCP/ Add CES


Add ALCAP Add Treelink PVC
IPoA Device (only3812E&A)

Add AAL2 Path

End
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23
Configuring Transport over ATM
 Configuring Physical Links at Transport Layer

− Adding the physical links to the NodeB for data transmission


over Iub interface
 Note
− An E1/T1 port can be configured to any of the following links for
data transmission:
▪ UNI link
▪ Fractional ATM link
▪ IMA link
▪ CES link
− An optical port can be configured to any of the following links for
data transmission:
▪ STM-1 link

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24


Configuring Transport over ATM

 Physical Links Configuration

 Physical ports(BTS3812E&A)

Board type Port number Work mode


IMA,UNI,
E1/T1 port No.0 CES, Fractional ATM,
Timeslot cross (connect with RNC)
E1/T1 port No.1 IMA,UNI,
NDTI CES, Fractional ATM
E1/T1 port No.2~3 IMA, UNI,
Timeslot cross
(connect with lower level NodeB)
E1/T1 port No.4~7 IMA,UNI
E1/T1 port No.0~3 CES
NAOI
Optical port No.0~1 STM-1

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25


Configuring Transport over ATM

 Physical Links Configuration

 Physical ports(DBS3800)

Board type Port number Work mode


IMA,UNI,
E1/T1 port No.0 Fractional ATM,
Timeslot cross (connect with RNC)
E1/T1 port No.1 IMA,UNI,
HBBU Fractional ATM
E1/T1 port No.2~3 IMA, UNI,
Timeslot cross
(connect with lower level NodeB)
E1/T1 port No.4~7 IMA,UNI

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26


Configuring Transport over ATM
 Physical Links Configuration

 Add an UNI link

Header

ATM cell 53 octets

ATM cell mapping field: 30 octets (TS1 - TS15 and TS17 - TS31)

Header

Header
Header

Header

TS0 provides F3 OAM functions: TS16: Reserved for signaling


Performance monitoring (CRC-4)
Transmission of FERF and LOC
Performance reporting
Detection of loss of frame alignment

256 bits/125 ls

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27


Configuring Transport over ATM

 Physical Links
Configuration
 Add an IMA Group

IMA group Physical I ink #0 IMA group


PHY PHY

Physical I ink #1
PHY PHY
µ¥ATMÐÅÔªÁ÷
Original ATM cell stream Recovered ATM cell
from ATM layer stream to ATM layer
Physical I ink #2
PHY PHY

IMA virtual link

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28


Configuring Transport over ATM
 Physical Links Configuration

 Add an IMA link to an IMA group


− IMA Link No. : defines the E1/T1 No. on the NDTI/HBBU
IMA Frame 2 IMA Frame 1 IMA Frame 0

... ... ... Link 0


ATM ATM ATM F ICP2 F F ATM F ICP1 ATM F ATM F ICP0

m-1 3 2 1 0 m-1 3 2 1 0 m-1 3 2 1 0


... ... ...
Link1
F ICP2 ATM F F ATM ICP1 ATM ATM ATM ATM ICP0 ATM F F

... ... ... Link2


F ATM ATM ICP2 F ATM F ATM ICP1 ATM ATM F ATM ICP0 ATM

Time

F Filler cell ATM ATM layer cell ICP2 ICP cell in frame #2

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29


Configuring Transport over ATM
 Physical Links Configuration

 Adding a Fractional ATM Link


− Bearing port No. : defines the E1/T1 No. on the NDTI
ATM cell carrying Fractional ATM link NDTI E1 0/1 Fractional E1 slots available for ATM
3G data cell, others may be used by 2G BTS

BTS38XX RNC Iub


NDTI interface
board

Transport other information


rather than ATM cell

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30


Configuring Transport over ATM
 Physical Links Configuration

 Adding a Timeslot Across Channel


− Add the corresponding Fractional ATM link on
NDTI/HBBU E1/T1 0 first
Fractional E1/T1timeslots are used
ATM cell carrying 3G data Fractional ATM Link by Fractional ATM; other timeslots
are used by timeslot across channel

NDTI No.0 E1/T1

BTS38XX RNC Iub


NDTI interface
board

Timeslot across channel

timeslots available on
2G BTS data NDTI No.2/3 E1/T1 2G BSC data

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31


Configuring Transport over ATM
 Physical Links Configuration
 Adding a CES Channel
− If NDTI is used, NDTI No.0/1 E1 is directly connected to 2G BTS
− If NAOI is used, NAOI E1/T1 is directly connected to 2G BTS
3G data packed E1/T1 timeslot data E1/T1 timeslot data
into ATM cell packed into ATM cell restored from ATM cell

ATM cell transport

BTS38XX RNC Iub


NDTI/NAOI interface
board

E1/T1, some E1/T1, some


timeslots available timeslots available
CES channel
2G BTS data 2G BSC data

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32


Configuring Transport over ATM

 Adding NCP

− Adding the NCP to the Iub interface


 Note
− Only one NCP is configured to the NodeB
− Negotiated with the peer end RNC
▪ VPI and VCI of NCP
▪ Traffic over the NCP includes: Service type,
Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33


Configuring Transport over ATM

 Adding CCP

− Adding a CCP to the Iub interface


 Note
− One NodeB supports multiple CCPs
− Negotiated with the peer end RNC
▪ CCP No.
▪ VPI and VCI of CCP
▪ Traffic over the CCP includes: Service type, Peak
cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34


Configuring Transport over ATM

 Adding ALCAP Node and link

− Adding the ALCAP node to the NodeB and an ALCAP


link to the Iub interface
 Note
− One NodeB is configured with only one ALCAP link
− Negotiated with the peer end RNC
▪ ATM address of NodeB
▪ VPI and VCI of the ALCAP link
▪ Traffic over the ALCAP link includes :Service type,
Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35


Configuring Transport over ATM

 Adding AAL2 Path


− Adding an AAL2 path to the Iub interface
 Note
− One NodeB may have multiple AAL2 paths
− The number of paths can be calculated based on the
traffic model over the Iub interface
− Negotiated with the peer end RNC
▪ AAL2 path ID
▪ VPI and VCI of the AAL2 path
▪ Traffic over the AAL2 path includes :Service type,
Peak cell rate , Sustain cell rate

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36


Configuring Transport over ATM
 Adding Treelink PVC

− Adding a Treelink PVC to the lower level NodeB


▪ The Treelink PVC enables the NodeB to connect with its upper
level node and lower level NodeB through different E1/T1 ports
 Note
− Optional for NodeB initial configuration
− Add Treelink PVCs to all the upper level NodeBs when the NodeB is
cascaded with the other NodeBs
− Negotiated with the lower level NodeB
▪ PVC to lower level NodeB
− Negotiated with the upper level NodeB
▪ PVC to upper level NodeB

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37


Configuring Transport over ATM
Architecture of Treelink PVC

AAL layer and higher layer

TREELINK PVC
ATM layer (PVC) ATM layer PVC

ATM physical layer bearer ATM physical layer bearer

Transport Physical medium Transport Physical medium

AA D A

RNC E1/T1 or Optical fiber E1/T1 or Optical fiber


BTS38XX(A) BTS38XX(B)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38


Configuring Transport over ATM
VPI Planning for VP-only Switching Treelink PVC

AAL layer and the higher layer

TREELINK PVC
ATM layer (PVC) ATM layer PVC

ATM physical layer bearer ATM physical layer bearer

Transport Physical medium Transport Physical medium

AA D A

RNC E1/T1 or Optic fiber E1/T1 or Optic fiber


BTS38XX (A) BTS38XX (B) BTS38XX (C)

VPI range: (6, 6) VPI range: (7, 7) VPI range: (8, 8)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39


Chapter 3 Configuring Transport

Sector 1 Configuring Transport over ATM

Sector 2 Configuring Transport over IP

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40


Configuring Transport over IP
Iub interface protocol over IP

Control Plane User Plane

RACH FP

USCH FP
CPCH FP
FACH FP
Radio
Network NBAP
Layer
NCP CCP CCP
Transport
Transport Network Transport Network
Network User Plane User Plane
Layer

SCTP
UDP

IP
IP

Data Link Layer Data Link Layer

A C

Physical Layer

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41


Configuring Transport over IP
Start

Configure the PPP Configure the MP Configure the Configure the


PPPoE Ethernet IP

Configure
the IP Route

Configure
the QoS
NodeB
(optional)

Configure
配置IP Route
the NBAP

Configure
配置IP
the OMRoute

Configure
the IP path

End

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42


Configuring Transport over IP
 Configure the PPP, MP, PPPoE, and Ethernet IP

− In a single transport mode, configure one type of transport links.


− In hybrid transport mode, configure E1 and FE transport links.
▪ For E1 links, configure PPP or MP.
▪ For FE links, configure PPPoE or Ethernet IP.

PDH/SDH

NodeB RNC
IP network

IP hybrid transmission

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43


Configuring Transport over IP
 Configure the IP route
 If the gateway type of the route is Ethernet, the next hop address and
the gateway IP address must be in the same network segment
 If the NodeB and RNC are in layer 2 networking
− The IP addresses of the FE ports on the NodeB and RNC should
be in the same subnet
 If the NodeB and RNC are in layer 3 networking
− The next hop address is the IP address of the router that
connects to the NodeB or the IP address of the port on a layer 3
switch.
 The destination address of packets has the corresponding route in the
routing table.
 The corresponding link layer address can be found only when the
router specifies the next hop IP address (gateway).
 Configure just one route to the same destination address.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44


Configuring Transport over IP

 Configure the QoS

 To configure signaling and OM priorities


 IP Quality of Service (QoS) is an IP network capability to provide
specific services over the IP network that uses mutiple bottom-layer
network technologies such as MP, FR, ATM, Ethernet, SDH, and
MPLS
 IP QoS supports the switching between the IP precedence and DSCP
 The IP QoS configuration is flexible

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45


Configuring Transport over IP

 Configure the NBAP

 Configure destination IP address & local IP interface, port type and


port number
 The IP routes for destination addresses are available
 Only one NCP can be configured
 Several CCPs can be configured
 The destination IP address, local port number, and destination port
number of the NCP/CCP on the same link should be different
 When you choose one NCP/CCP on the NBAP tab page, the
corresponding links are displayed in the middle part, and the
corresponding routes are displayed in the lower part

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46


Configuring Transport Based on IP
 Configure the OM

 Ensure that the route from the


LMT (or M2000) to the subnet is
configured
 Only one OM channel can be
configured
 If you choose an OM channel in
the upper part of the OM tab page,
the corresponding route is
displayed in the lower part
 The destination IP address of the
OM channel is the IP address of
the NodeB LMT or M2000

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47


Configuring Transport over IP
 Configure the IP path

 The IP routes for destination addresses are available


 The IP path does not have bandwidth limit. Therefore, to configure the
IP path is to differentiate service priorities. When the HSDPA service
is transmitted, configure two IP paths with different path IDs. The two
paths correspond to R99 service and HSDPA service. There is no
service priority at the NodeB side. Therefore, configure one IP path at
the NodeB side
 If you choose one path on the upper part of the IP path tab page, the
corresponding links are displayed in the middle part and the
corresponding route is displayed in the lower part

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48


Chapter 1 Data Configuration Overview

Chapter 2 Configuring Physical Equiment

Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell

Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49


Configuring Local Cell
Procedure of Local Cell Configuration

Locall
cell

Add Add
Add Local
Site Sector Cell

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50


Configuring Local Cell
 Adding Site
− Adding a site to the NodeB
 Note
− A site number within one
NodeB must be unique.

 Adding Sector

− Adding a sector to the NodeB


 Note
− A sector number must be unique within one NodeB
− Configuring a sector is mainly configuring the corresponding
antenna and feeder system

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51


Configuring Local Cell

 Adding Local Cell


− Adding a local cell to the NodeB
 Note
− Local Cell ID must be unique within the same
NodeB
− Negotiated with the peer end RNC
▪ Local Cell ID
▪ Uplink Frequency
▪ Downlink Frequency

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52


Chapter 1 Data Configuration Overview

Chapter 2 Configuring Physical Equiment

Chapter 3 Configuring Transport

Chapter 4 Configuring Local Cell

Chapter 5 Configuring Operation and Maintenance Channel

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53


Configuring Operation and Maintenance Channel
 NodeB provides two modes of operation and
maintenance:
 Near end operation and maintenance:
 Far end operation and maintenance:

NMPT Ethernet IPoA Peer IP


Subnet 4
Port IP address RNC BAM IP
IPoA local IP
SNTP Server

Subnet 1 Subnet 2 Subnet 3 Subnet 5

RNC
M2000

BTS3812E

LMT1

LMT 2

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54


Operation and Maintenance Channel Configuration
IPoA maintenance configuration

The route to LMT (D) Configure the


IPoA peer (C) Configure LMT
(IP4), SNTP Server, (A) Configure IPoA route to
IP: IP2 Ethernet
gateway: IP2 (B) local IP: IP1 IP: IP4 BTS3812E (IP1),
gateway:IP3

BTS3812E
NMPT ETH IP IP0 IP1 IP2

Lower level IP4


Node B IP3
LocalBTS3812E
RNC LMT
IP6 IP5

The route to
LMT(IP4) Configure the route to
gateway:IP5 Configure IPoA (B) Configure IPoA peer lower NodeB (IP6),
local IP: IP6 networking PVC IP:IP5 gateway:IP3

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55


Configuring Operation and Maintenance Channel
 Adding IPoA Device
− Configuring an IPoA maintenance channel to the NodeB
▪ Through the IPoA maintenance channel, you may log
in to the NodeB remotely with the LMT or the M2000
 Note
− You can add only one IPoA maintenance channel to a
NodeB
− Negotiated with the peer end RNC
▪ Local IP and Local IP Mask
▪ Peer IP and Peer IP Mask
▪ VPI/VCI
▪ Service Type

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56


Thank You
www.huawei.com

You might also like