erica) AE Data sheet No, : PLTHYOIt4 DESCRIPTION AE Transducers convert various electrical powerline paramot Vt ical power line parameters viz. Voltage, Current, Frequency, Power Factor wer, Apparent power into OC current or voltage output THE pot of Transducer Is ‘Active power, Reactive ascchdent of ad impedance. These are used in various electical, thermal, chemical & other power pants to ‘ether locally or from remote using various devices such as indicating meters, data loggers, monitor processed data recorders, SCADA systems. ‘These transducers can also be used as external units in conjunction with analog or digital indicators FEATURES Buroe Open & short out protect (20 cainga 2EA6] ¢ Current and Votage output are independent of load impedance Aguse Ae + Suitable for panel as well as DIN ~ RAIL mounting 30|" ELECTRICAL SPECIFICATIONS © TYPE DC or AC: 1Ph/3Ph-1EL/3Ph- 2EL - 3W/3Ph- 3EL- 4W ¢ INPUTPARAMETER : DC: Voltage, Current ‘AC: Voltage, Current, Watt, Var, VA, Frequency, Power Factor INPUT PARAMETER RANGE # VOLTAGE DC :500v, AC: S00v CURRENT DC : 5A (for higher ranges: 50 300mV ext. Shunt) , AC» 1A SA FREQUENCY : 50/60Hz +5Hz, 400Hz + 20Hz(Any other Frequency on request) POWER FACTOR: 0.5 (Lag) — Unity ~0.5 (Lead) POWER : Please specity Single Output / Dual Output [o-ima | 0-5ma | 0-10mA 1k * OUTPUT RANGE RANGE : ¢ CURRENT MAX.LOAD | 10k | 2k ¢ VOLTAGE MIN. LOAD O-20mA | 4-20mA [10-0 - 10m soon) s00n | 1ke V [0=10V | 1-5v | 2-10v | 10-0-10V a | SK | 2K | SK | SKA | 50t * ACCURACY 40.5% of full scale for Voltage, Current, Watt, Var, VA, Power Factor +£0.2% of contre frequency for Frequency Transducer. AUX. SUPPLY 63.5V, 110V, 220V, 230V, 240V, 380, 415V, 440V AC (Tor #10%V, 50/60 2av, 4BV, 110V, 220V DC (for + 10%V). * VABURDEN For VOLTAGE <2, For CURRENT < 0. RIPPLE Maximum 0.5% of the span. OVERLOAD CAPACITY 5, For AUX. SUPPLY <4 # VOLTAGE cont. 120% of nominal short time (10 sec) : 150% of nominal ¢ CURRENT cont. 120% of nominal short time (3 sec) 410 times of nominal 300 m. sec. RESPONSE TIME + OPENCKT. VOLTAGE: 22V max 4 IMPULSE VOLTAGE: SkV, 1.2/0 usec. (0.5)) + INSUL* RESISTANCE : Greater than 20M ohms at SOO oc § DIELECTRIC TEST: 2kV RMS for 1 minute. (4KV on request) + OPERATING TEMP. : 0°C to 55°C. 4+ STORAGE TEMP. -20°C to 70°C HUMIDITY Up to 95% RH CONFORMS TO 1.8.12784 | LE.C. 688, ee | Power Line Transducers Data sheet No PLT/t0/14 TYPICAL WIRING SYSTEM. PD1 TRANSDUCER | PD3._ TRANSDUCER CURRENT / VOLTAGE / FREQUENCY / VER Fi WATT /VAR/ VA WITHOUT CT/ PT aU CTE Output 1) Output 2 (output) (Oxtbut2| J 4 T T ol 3/4)? 9 )9)4 0 n——_1 Sup y Side Load Side 1 For Single phase Power Factor termina na Sto be cca "ep ced by terminal no.11 for Netural connections. 1 Fo 3 Phase-1 Element. Power Factor terminal no 2 '3£ to be replaced by termina no 5 & Brespectvely m | for 2.813 connection TERMINAL CONNECTIONS, D4 ( WITH 42 TERMINALS) Tern BSR eae Cen Fresueny 18 we bc ouRRENT ae oe 13-14 De voLTAGe Settpowered Curent Transducer operates from 2% of Input signal. Seltpowered Frequency, Power & Power Factor ransducer operates on £10% ated voltage MECHANICAL SPECIFICATIONS: Model PD1 Ko a3 tea} oo "J Model PD3 ST oo) ep | i } T lg | é ae L | LL | | | =a l L | Oa btetng Hes 20 wt +100 719 7 behept omae Oi at oun Arg Ordering information _ pen 2inptPaaet 2)" canegendg hut wARange 4) Cupid Ra 5) Aux. Supply 6) CTR (if any) 7) PTR (if any) ‘Sees

You might also like