Professional Documents
Culture Documents
ANALYSIS REPORT OF
SPIDER GLAZING
FACADE CONTRACTOR: -
1
INDEX
1 INTRODUCTION 3
6 CONNECTION DESIGN 22
DESIGN OF ANGLR BRACKET FOR FIN 23
DESIGN OF SS THROUGH BOLT 31
DESIGN OF ‘F’ TYPE BRACKET 32
2
1. INTRODUCTION
3
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Design intend -
The design calculations ensures the stability of external façade (Spider glazing) against dead
and wind loads.
The façade glass panel (12 mm thk toughened) is supported by S.S. Spider fittings. The
spiders are mounted on Vertical fin (13.52) Laminated toughened Glass. The fin is supported by
angle bracket at top. The top angle bracket is fixed on RCC structure. The glass is fixed in 'F' type bracket
at top & bottom.
The detailed calculations for glass, 'F' type bracket, Angle brackets, anchor fasteners have
been enclosed. The support reactions enlisted in the report have to be referred by structural consultant
and ensure the satbility of primary structure.
The structural elements in glazing systems have been checked for its strength and servic-
eability in accordance with various relevant standards.
Standards :
1. Design Loads
2. Mild Steel
4. Glass
4
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Material properties:-
1. Mild Steel
2. S.S. Bolts and Nuts Grades 304 and 316 (Property class - 70)
5
2. STRUCTURAL ARRANGEMENT DRAWINGS
6
7
8
9
1 2 3 4 5 6 7 8 9 10 11 12
H H
N
Key Plan
FACADE LEGEND:
G G
GENERAL NOTES:
F F
IN SIDE
OUT SIDE
E D
CLIENT:
NYATI UNITREE
YERAWADA, PUNE - 411 006 , INDIA
D E
TEL.-020-66564508 WEB SITE VISIT US
AT.- www.nyatigroup.com
DESIGN ARCHITECT :
ETHIQUE ARCHITECTS & ASSOCIATES
MUMBAI OFFICE : PUNE OFFICE :
816/817 , 8th Floor , 4/3 - E , 'Mauli Shree' Apartment
Damji Shamji Business Galleria, Lokmanya Nagar,
Above D-Mart, L.B.S Marg Off. L.B.S.Marg,
Next To Toyo Engineering, Opp. Rupee Bank,
Kanjurmarg (W) Sadashive Peth,
EAA Mumbai - 400 078.
Tel. 022-25785762 / 65
Pune - 30
TEL:-(020) 2433 3803
E-mail : info@ethique.in E mail :ethiquepune2@gmail.com
PROJECT ARCHITECT :
SHIRISH DASNURKAR & ASSOCIATES
architects&designer
RCC 35, LAXMIPARK COLONY, NAVI PETH, PUNE-411030.
C PH: 020-24530461/62/63 E-MAIL: shirishdasnurkar@gmail.com C
FACADE CONSULTANT :
ALUVISION
D
TL .T
V
PSO
NIT
U
O
LS E
D
A
C
AF
FACADE CONTRACTOR :
®
Glazium Facades Pvt. Ltd.
Gate No. 607/608/609 Radhika Industrial Park,
Shed No. 3, Near MSEB Office At Post - Velu Tal - Bhor
Email: glazium@gmail.com
info@glazium.in
B B
THESE DESIGNS, DRAWINGS AND SPECIFICATION AND THE COPYRIGHT THEREIN ARE THE
PROPERTY OF GLAZIUM FACADES PUNE AND MUST NOT BE COPIED OR REPRODUCED
WHOLLY OR IN PART WITHOUT THEIR EXPRESS PERMISSION.
PROJECT:
PROPOSED COMMERCIAL BUILDING AT VIMAN NAGAR
PUNE FOR NYATI BUILDERS
DRAWING TITLE:-
TYP. U CHANNEL BOTTOM FIXING DETAIL
GF-NE-401-DT-03
1 2 3 4 5 6 7 8 9 10 11 12
3. LOAD INPUT SHEET
11
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
12
4. GLASS PANEL DESIGN
13
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Input Data :-
Density of glass = 25 kN/m3
Wind Load a = 1.20 kN/m2
Glaas panel width, W = 1750 mm
Glaas panel height, H = 3000 mm
Design parameters :-
The glass panel has been analysed and checked in staad for stability and deflection.
Hence safe
Hence safe
14
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
15
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
DISPLACEMENT DIAGRAM
16
STAAD SPACE DXF IMPORT OF 1.DXF
START JOB INFORMATION
JOB NAME SPG
ENGINEER DATE 15-Sep-21
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 -2.7 4.4 0; 2 -2.7 4.5 0; 3 -2.7 4.6 0; 4 -2.7 4.7 0; 5 -2.7 4.8 0;
6 -2.7 4.9 0; 7 -2.7 5 0; 8 -2.7 5.1 0; 9 -2.7 5.2 0; 10 -2.7 5.3 0;
2192 -0.95 7.15 0; 2193 -0.95 7.3 0; 2194 -0.95 7.25 0; 2195 -0.95 7.4 0;
2196 -0.95 7.35 0;
ELEMENT INCIDENCES SHELL
1 2 62 63 32; 2 32 63 64 1; 3 3 65 66 33; 4 33 66 62 2; 5 4 67 68 34;
6 34 68 65 3; 7 5 69 70 35; 8 35 70 67 4; 9 6 71 72 36; 10 36 72 69 5;
2095 2103 2191 2192 2133; 2096 2133 2192 2189 2102; 2097 2104 2193 2194 2134;
2098 2134 2194 2191 2103; 2099 2105 2195 2196 2135; 2100 2135 2196 2193 2104;
ELEMENT PROPERTY
1 TO 2100 THICKNESS 0.012
DEFINE MATERIAL START
ISOTROPIC GLASS
E 7.17e+007
POISSON 0.22
DENSITY 25
DAMP 2.8026e-044
END DEFINE MATERIAL
CONSTANTS
MATERIAL GLASS ALL
SUPPORTS
1 31 64 121 123 153 186 243 245 275 308 365 367 397 430 487 489 519 552 609 -
611 641 674 731 733 763 796 853 855 885 918 975 977 1007 1040 1097 1099 1129 -
1162 1219 1221 1251 1284 1341 1343 1373 1406 1463 1465 1495 1528 1585 1587 -
1617 1650 1707 1709 1739 1772 1829 1831 1861 1894 1951 1954 1983 2016 2073 -
2076 2105 2138 2195 ENFORCED BUT FY
150 2068 ENFORCED BUT FX MX MY MZ
LOAD 1 LOADTYPE None TITLE D.L.+ WL
SELFWEIGHT Y -1.05
ELEMENT LOAD
1 TO 2100 PR GZ 1.2
PERFORM ANALYSIS PRINT ALL
FINISH
**NOTE:- SOME LINES ARE CUT SHORT TO REDUCE NO. OF PAGES IN REPORT
17
5. GLASS FIN DESIGN
18
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Input Data :-
Density of glass = 25 kN/m3
Design Wind Load = 1.20 kN/m2
Fin width, W = 250 mm
Average spacing between fins = pannel width = 1750 mm
Span of fin, l = 450 mm
Thickness of fins, t = 12 mm
Glass panel specifications :- 13.52 Laminated Toughened (6 mm + 1.52 pvb layer + 6 mm toughned)
PROPERTIES OF FIN
19
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Force calculations
A)Dead Load
Dead load of Fin = 25*0.012*0.25 = 0.08 kN/m
Height of fin = 0.45 m
DL of fin, V1 = 0.03 kN
V= V1+V2 = 2.13 kN
V = 2133.75 N
B) Wind Load
Wind load = 1.20 kN/m2
Effective width = 1.75 m
Span of fin, L = 0.45 m
Stress calculations
1) Axial Stress
Axial stress , V/A = 0.89 N/mm2
<
Allowable tensile stress = 20.00 N/mm2
2) Shear Stress
Shear stress, H/A = 1.95 N/mm2
<
Allowable shear stress = 20.00 N/mm2
Hence safe.
20
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Hence safe.
= ( w* l3)
3*EI
Hence safe.
21
6. CONNECTION DESIGN
22
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Grade - Fy 250
Size - 100*100*300*10
Force calculations
Total vertical load at top, v = 2.13 kN
Factored load, V = 3.20 kN
23
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Properties of bracket
Grade = Fy 250
Yield Strength, Fy = 250.00 N/mm2
Depth, d = 100.00 mm
Width, w = 100.00 mm
Length, l = 250.00 mm
Thickness, t = 10.00 mm
Eccentricity from top for horizontal load = 75.00 mm
Area, A = 2500.00 mm2
Section modulus, Z = tl2/6 = 104166.67 mm3
Hence safe.
24
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
The horizontal leg is 100 mm in width, the connection bolt is at center of width.
Hence safe.
Hence safe.
25
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Vd = 1.60 kN
Hd = 3.51 kN
Md = 1.58 kN-m
26
HILTI REPORT PAGES ARE MISSING.
HOWEVER WE HAVE CHECKED FROM
OUR END & ITS FOUND OK.
27
28
29
30
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Properties of bolt,
Diameter of bolt = 12.00 mm
Design dia. of bolt = 9.86 mm
C/s area = 76.33 mm2
1/2
Resultant Shear Load = (H2+V2)^ = 17.75 N
Stress claculations,
Hence safe.
31
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Design of MS 'F' type bracket at top & bottom for façade glass
Properties of bracket,
Bracket plates = 6 mm
Base plate = 8 mm
Length, l = 500.00 mm
Thickness, t = 8.00 mm
Area, A = 4000.00 mm2
Section modulus, Zxx = 5333.33 mm3
As per staad,
The bracke is supported at max c/c = 0.50 m
Horizontal force at every 0.05 m = 0.18 kN
No of support points in 0.5 m = 10
Total horizontal force at sopport location, H = 1.83 kN
Factored force, Hd = 2.75 kN
Stress calculations,
Max shear force, H/A = 0.69 N/mm2
<
Allowable shear stress = 100.00 N/mm2
Hence safe.
32
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing
Hd = 2.75 kN
Md = 0.65 kN-m
Hd = 2.75 kN
Md = 0.65 kN-m
33
HILTI REPORT PAGES ARE MISSING.
HOWEVER WE HAVE CHECKED FROM
OUR END & ITS FOUND OK.
34
35
36
37
HILTI REPORT PAGES ARE MISSING.
HOWEVER WE HAVE CHECKED FROM
OUR END & ITS FOUND OK.
38
39
40
41