You are on page 1of 41

Doc.-No.

: GFPL/NB/SPG-01 R1 Date : 28/09/2021

ANALYSIS REPORT OF
SPIDER GLAZING

PROJECT: - PROPOSED COMMERCIAL BUILDING AT VIMAN


NAGAR, PUNE

CLIENT: NYATI UNITREE, PUNE

DESIGN ARCHITECT: ETHIQUE ARCHITECTS & ASSOCIATES

FAÇADE CONSULTANT: ALUVISION FAÇADE SOLUTIONS P L

FACADE CONTRACTOR: -

GLAZIUM FACADES P.L.


Gat No. 607/608/609,
Radhika Industrial Park, Shed No. 3,
Near MSEB Office, At post - Velu,
Tal - Bhor, Dist - Pune - 412205.
Email : info@glazium.in

1
INDEX

Sr.No. DESCRIPTION Page No.

1 INTRODUCTION 3

2 STRUCTURAL ARRANGEMENT DRAWINGS 6

3 LOAD INPUT SHEET 11

4 GLASS PANEL DESIGN 13


SPG 1 - 1750x3000 14

5 GLASS FIN DESIGN 18

6 CONNECTION DESIGN 22
DESIGN OF ANGLR BRACKET FOR FIN 23
DESIGN OF SS THROUGH BOLT 31
DESIGN OF ‘F’ TYPE BRACKET 32

2
1. INTRODUCTION

3
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Design intend -
The design calculations ensures the stability of external façade (Spider glazing) against dead
and wind loads.
The façade glass panel (12 mm thk toughened) is supported by S.S. Spider fittings. The
spiders are mounted on Vertical fin (13.52) Laminated toughened Glass. The fin is supported by
angle bracket at top. The top angle bracket is fixed on RCC structure. The glass is fixed in 'F' type bracket
at top & bottom.
The detailed calculations for glass, 'F' type bracket, Angle brackets, anchor fasteners have
been enclosed. The support reactions enlisted in the report have to be referred by structural consultant
and ensure the satbility of primary structure.
The structural elements in glazing systems have been checked for its strength and servic-
eability in accordance with various relevant standards.

Standards :

1. Design Loads

1.01 IS 875 - 1987 Part (I) : 1987


Code of practice for design loads for building an dstructures- Dead loads

1.02 IS 875 - 1987 Part (II) : 1987


Code of practice for design loads for building an dstructures- Imposed loads

1.03 IS 875 - 2015 Part (III) :2015


Code of practice for design loads for building an dstructures- Wind loads

1.04 IS 1893 - Part - 1 :2002


Crieteria for earthquake resistant design of structures - General provisions

2. Mild Steel

2.01 IS 800 - 2007


General construction in steel - Code of practice

4. Glass

4.01 ASTM E-1300: 2004


Stanard practice for determining Load resistance of glass in buildings

4.02 AS 1288: 2006


Glass in buildings - Selection and installation

4
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Material properties:-

1. Mild Steel

a) Density = 7.85 KN/m3

b) Modulus of Elasticity Es = 205000 N/mm2

c) Ultimate Tensile Strength Fu s = 410 N/mm2

d) Tensile Yield Strength Fty s = 250 N/mm2

e) Allowable axisl stress Fa s = 150 N/mm2

f) Allowable bending stress Fb s = 165 N/mm2

g) Allowable shear stress Fv s = 100 N/mm2

h) Allowable bearing stress Pb s = 175 N/mm2

2. S.S. Bolts and Nuts Grades 304 and 316 (Property class - 70)

a) Allowable shear stress Fs = 311 N/mm2

b) Allowable tensile stress Ft = 450 N/mm2

c) Allowable bearing stress Fb = 828 N/mm2

5
2. STRUCTURAL ARRANGEMENT DRAWINGS

6
7
8
9
1 2 3 4 5 6 7 8 9 10 11 12

H H

N
Key Plan

FACADE LEGEND:

G G

GENERAL NOTES:

F F

IN SIDE

OUT SIDE
E D

CLIENT:

NYATI UNITREE
YERAWADA, PUNE - 411 006 , INDIA
D E
TEL.-020-66564508 WEB SITE VISIT US
AT.- www.nyatigroup.com

DESIGN ARCHITECT :
ETHIQUE ARCHITECTS & ASSOCIATES
MUMBAI OFFICE : PUNE OFFICE :
816/817 , 8th Floor , 4/3 - E , 'Mauli Shree' Apartment
Damji Shamji Business Galleria, Lokmanya Nagar,
Above D-Mart, L.B.S Marg Off. L.B.S.Marg,
Next To Toyo Engineering, Opp. Rupee Bank,
Kanjurmarg (W) Sadashive Peth,
EAA Mumbai - 400 078.
Tel. 022-25785762 / 65
Pune - 30
TEL:-(020) 2433 3803
E-mail : info@ethique.in E mail :ethiquepune2@gmail.com

PROJECT ARCHITECT :
SHIRISH DASNURKAR & ASSOCIATES
architects&designer
RCC 35, LAXMIPARK COLONY, NAVI PETH, PUNE-411030.
C PH: 020-24530461/62/63 E-MAIL: shirishdasnurkar@gmail.com C

FACADE CONSULTANT :

ALUVISION
D
TL .T
V
PSO
NIT
U
O
LS E
D
A
C
AF

FACADE CONTRACTOR :
®
Glazium Facades Pvt. Ltd.
Gate No. 607/608/609 Radhika Industrial Park,
Shed No. 3, Near MSEB Office At Post - Velu Tal - Bhor
Email: glazium@gmail.com
info@glazium.in
B B
THESE DESIGNS, DRAWINGS AND SPECIFICATION AND THE COPYRIGHT THEREIN ARE THE
PROPERTY OF GLAZIUM FACADES PUNE AND MUST NOT BE COPIED OR REPRODUCED
WHOLLY OR IN PART WITHOUT THEIR EXPRESS PERMISSION.

PROJECT:
PROPOSED COMMERCIAL BUILDING AT VIMAN NAGAR
PUNE FOR NYATI BUILDERS

DRAWING TITLE:-
TYP. U CHANNEL BOTTOM FIXING DETAIL

DRAWN CHD BY APRD BY SCALE


A 03 TYP. U CHANNEL BOTTOM FIXING DETAIL DF BD/SP AP 1:2 [A3]
A
PE-401 SCALE : AS SHOWN SHOP DRAWING DATE 29-Sep-21
DRAWING No. REV. R0

GF-NE-401-DT-03
1 2 3 4 5 6 7 8 9 10 11 12
3. LOAD INPUT SHEET

11
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

LOAD INPUT SHEET


1) Dead load calculaions
Glass panel specification -12 mm thk clear toughened glass

Density of glass = 25.00 kN/m3


Effective Thickness of glass considered = 12.00 mm
Wt. of glass per m2 = W1 = 0.012x25 = 0.30 kN/m2
Wt of fixings = W2 = 0.05 kN/m2
Total dead load = W1 + W2 = W = 0.35 kN/m2
Design dead load = 0.40 kN/m

2) Wind load calculation as per IS : 875 (Part 3) - 2015 :-

Location of structure = PUNE

Design Wind pressure as per Tender = 1.20 kN/m2

12
4. GLASS PANEL DESIGN

13
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Glass panel design

1. SPG 1 - Panel - 1750x3000

Input Data :-
Density of glass = 25 kN/m3
Wind Load a = 1.20 kN/m2
Glaas panel width, W = 1750 mm
Glaas panel height, H = 3000 mm

Glass panel specifications :-


Support system:- Glass - 12 mm thk clear toughened glass
Two point support on spider fitting & top & bottom in 'F' bracket

Design parameters :-

Effective thickness for glass , t = 12 mm

The glass panel has been analysed and checked in staad for stability and deflection.

Check for Strength-


Actual stress as per STAAD = 41.90 N/mm2
<
Allowable stress as per AS 1288 = 50.00 N/mm2

Hence safe

Check for Deflection-


Actual deflection as per STAAD = 20.37 mm
<
Alloable deflection = 1750/60 = 29.17 mm

Hence safe

14
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

PLATE STRESS DIAGRAM

15
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

DISPLACEMENT DIAGRAM

16
STAAD SPACE DXF IMPORT OF 1.DXF
START JOB INFORMATION
JOB NAME SPG
ENGINEER DATE 15-Sep-21
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 -2.7 4.4 0; 2 -2.7 4.5 0; 3 -2.7 4.6 0; 4 -2.7 4.7 0; 5 -2.7 4.8 0;
6 -2.7 4.9 0; 7 -2.7 5 0; 8 -2.7 5.1 0; 9 -2.7 5.2 0; 10 -2.7 5.3 0;
2192 -0.95 7.15 0; 2193 -0.95 7.3 0; 2194 -0.95 7.25 0; 2195 -0.95 7.4 0;
2196 -0.95 7.35 0;
ELEMENT INCIDENCES SHELL
1 2 62 63 32; 2 32 63 64 1; 3 3 65 66 33; 4 33 66 62 2; 5 4 67 68 34;
6 34 68 65 3; 7 5 69 70 35; 8 35 70 67 4; 9 6 71 72 36; 10 36 72 69 5;
2095 2103 2191 2192 2133; 2096 2133 2192 2189 2102; 2097 2104 2193 2194 2134;
2098 2134 2194 2191 2103; 2099 2105 2195 2196 2135; 2100 2135 2196 2193 2104;
ELEMENT PROPERTY
1 TO 2100 THICKNESS 0.012
DEFINE MATERIAL START
ISOTROPIC GLASS
E 7.17e+007
POISSON 0.22
DENSITY 25
DAMP 2.8026e-044
END DEFINE MATERIAL
CONSTANTS
MATERIAL GLASS ALL
SUPPORTS
1 31 64 121 123 153 186 243 245 275 308 365 367 397 430 487 489 519 552 609 -
611 641 674 731 733 763 796 853 855 885 918 975 977 1007 1040 1097 1099 1129 -
1162 1219 1221 1251 1284 1341 1343 1373 1406 1463 1465 1495 1528 1585 1587 -
1617 1650 1707 1709 1739 1772 1829 1831 1861 1894 1951 1954 1983 2016 2073 -
2076 2105 2138 2195 ENFORCED BUT FY
150 2068 ENFORCED BUT FX MX MY MZ
LOAD 1 LOADTYPE None TITLE D.L.+ WL
SELFWEIGHT Y -1.05
ELEMENT LOAD
1 TO 2100 PR GZ 1.2
PERFORM ANALYSIS PRINT ALL
FINISH

**NOTE:- SOME LINES ARE CUT SHORT TO REDUCE NO. OF PAGES IN REPORT

17
5. GLASS FIN DESIGN

18
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

GLASS FIN DESIGN ( 0.45 m span )

Input Data :-
Density of glass = 25 kN/m3
Design Wind Load = 1.20 kN/m2
Fin width, W = 250 mm
Average spacing between fins = pannel width = 1750 mm
Span of fin, l = 450 mm
Thickness of fins, t = 12 mm

Glass panel specifications :- 13.52 Laminated Toughened (6 mm + 1.52 pvb layer + 6 mm toughned)

Support System:- Cantilever fin with supported at top only

The fin has been analysed as simply supported beam.

PROPERTIES OF FIN

Elastic Modulus, E = 70000 N/mm2


Depth of fin, d = 250+150/2 = 200 mm
( The fin is tapered, hence considered average sectional area for calculations )
Thickness of fin, t = 12.00 mm
C/S area, A = 2400 mm2
M.I., I = td3/12 = 8000000 mm4
Section modulus, Z= td2/6 = 80000 mm3
M.I. about weak axis, Iyy = 28800 mm4

Torsional rigidity, J = dt3/3 x (1 -0.63 b/d) = 110845.44 mm3

Critical Bending Moment = Mcr = (g1/Lay){(ExIyy)x(GxJ)}1/2

g (As per Table c1) = 3.1


Shear Modulus, G = 28300 N/mm2
Lay = 1750 mm

Critical Bending Moment = Mcr = 4454726.471 N-mm

Mcr = 4.45 kN-m

19
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Force calculations
A)Dead Load
Dead load of Fin = 25*0.012*0.25 = 0.08 kN/m
Height of fin = 0.45 m
DL of fin, V1 = 0.03 kN

DL of glass panel, V2 = 1.75*3.0*0.4 = 2.10 kN

V= V1+V2 = 2.13 kN
V = 2133.75 N

B) Wind Load
Wind load = 1.20 kN/m2
Effective width = 1.75 m
Span of fin, L = 0.45 m

Point load of glass due to wind load as per staad = 2.34 kN


Point load from two glasses will act on fin, H = 4.68 kN
Moment, M = H*L = 2.11 kN-m

Stress calculations
1) Axial Stress
Axial stress , V/A = 0.89 N/mm2
<
Allowable tensile stress = 20.00 N/mm2

2) Shear Stress
Shear stress, H/A = 1.95 N/mm2
<
Allowable shear stress = 20.00 N/mm2

3) Bending stress check


Max. bending stress, M/Zxx = 26.34 N/mm2
<
Allowable bending stress = 50.00 N/mm2

Hence safe.

20
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

4) Torsional rigidity check

Max. bending moment, M = 2.11 kN-m


<
Critical bending moment, Mcr = 4.45 kN-m

Hence safe.

Check for Deflection

= ( w* l3)
3*EI

Length of fin, l = 450 mm


Modulus of elasticity, E = 70000 N/mm2
Moment of inertia, Ixx = 8000000 mm4
Point Load, P = 4682.00 N

Max. deflection, = 0.25 mm


<
Allowable deflection =4100/240 or 20 mm whichever is small = 1.88 mm

Hence safe.

21
6. CONNECTION DESIGN

22
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Design of MS Angle bracket for Glass Fin

Grade - Fy 250
Size - 100*100*300*10

Angle bracket is designed for max reaction of fin,

Force calculations
Total vertical load at top, v = 2.13 kN
Factored load, V = 3.20 kN

Max. horizontal Shear load at top, h = 4.68 kN


Factored load, H = 7.02 kN

Bending moment, m = 2.11 kN-m


Factored moment, M = 3.16 kN-m

Lever arm between extreme bolts = 0.20 m


Tension produced on either side, T = 15.80 kN

23
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Properties of bracket
Grade = Fy 250
Yield Strength, Fy = 250.00 N/mm2
Depth, d = 100.00 mm
Width, w = 100.00 mm
Length, l = 250.00 mm
Thickness, t = 10.00 mm
Eccentricity from top for horizontal load = 75.00 mm
Area, A = 2500.00 mm2
Section modulus, Z = tl2/6 = 104166.67 mm3

Design of vertical leg -

Moment, M = 3.16 kN-m


No. of vertical legs = 2
Moment per vertical plate, M1 = 1.58 kN-m
M1 = 1580175.00 N-mm

Max. Bending stress, M1/Z = 15.17 N/mm2


<
As per IS 800, 2007, Fbcy = 0.66 x Fy = 0.66*250 = 165.00 N/mm2

Shear force per plate, h = 3511.50 N

Max. shear stress, h/A = 1.40 N/mm2


<
As per IS 800, 2007, Fsy = 0.4 x Fy =0.4 x 250 = 100.00 N/mm2

Vertical Tensile load on each plate, v = 1600.31 N

Max. Tensile stress, v/A = 0.64 N/mm2


<
As per IS 800, 2007, Ft = 0.6 x 250 = 150.00 N/mm2

Hence safe.

24
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Design of horizontal leg

Width of bracket, w = 100.00 mm


Length of bracket, l = 250.00 mm
Thickness, t = 10.00 mm
C/s area of plate = 2500.00 mm2
Section modulus of plate = L*t2/6 = 4166.67 mm3

Vertical load on each plate, V1 = 1.60 kN

Moment due to horizontal force, M = 1.58 kN-m

Lever arm = Distance between two bolts = 0.20 m

Tension due to moment, V2 = 7.90 kN

Design vertical load, V=V1+V2 = 9.50 kN

The horizontal leg is 100 mm in width, the connection bolt is at center of width.

Eccenticity of vertical load = 0.05 m

Moment on each plate = V*e = 0.48 kN-m


M = 475059.38 N-mm

Max. Bending stress = 114.01 N-mm2


<
Allowable Bending stress = 165.00 N-mm2

Hence safe.

Combine bending stress = 129.18 N-mm2


<
Allowable Bending stress = 165.00 N-mm2

Hence safe.

25
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Anchor fastener Design for angle bracket

Hilti anchor fastener specification = HST-3-R M12x115


Minimum embedment - 75.00 mm

Vd = 1.60 kN

Hd = 3.51 kN

Md = 1.58 kN-m

Calculations of hilti fastener has been enclosed herewith.

26
HILTI REPORT PAGES ARE MISSING.
HOWEVER WE HAVE CHECKED FROM
OUR END & ITS FOUND OK.

27
28
29
30
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Design of S.S. Through bolt for Glass Fin

S.S. Bolt specification -


Grade = SS 316 A4-70
Size = M12
No. of bolts = 2

Total factored vertical load = 3.20 kN


Force in each bolt, V1 = 1.60 kN
Moment, M = 3.16 kN-m
Lever arm = 0.20 m
Force in extereme bolt due to moment, V2=M/lever arm = 15.80 kN
Design load = V =V1+V2 = 17.40 kN

Horizontal factored shear force = 7.02 kN


Shear in each bolt, H = 3.51 kN

Properties of bolt,
Diameter of bolt = 12.00 mm
Design dia. of bolt = 9.86 mm
C/s area = 76.33 mm2

1/2
Resultant Shear Load = (H2+V2)^ = 17.75 N

Total shear force on each bolt = 17752.81 N

Stress claculations,

Actual Shear stress on each bolt = 116.30 N/mm2


<
Permissible Shear Stress = 313.00 N/mm2

Hence safe.

31
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Design of MS 'F' type bracket at top & bottom for façade glass

Properties of bracket,
Bracket plates = 6 mm
Base plate = 8 mm

Length, l = 500.00 mm
Thickness, t = 8.00 mm
Area, A = 4000.00 mm2
Section modulus, Zxx = 5333.33 mm3

As per staad,
The bracke is supported at max c/c = 0.50 m
Horizontal force at every 0.05 m = 0.18 kN
No of support points in 0.5 m = 10
Total horizontal force at sopport location, H = 1.83 kN
Factored force, Hd = 2.75 kN

Moment at every 0.05 m = 0.04 kN-m


No of support points in 0.5 m = 10
Total moment at sopport location, M = 0.43 kN-m
Factored moment, Md = 0.65 kN-m

Stress calculations,
Max shear force, H/A = 0.69 N/mm2
<
Allowable shear stress = 100.00 N/mm2

Max bending stress, M/Zxx = 120.94 N/mm2


<
Allowable bending stress = 165.00 N/mm2

Hence safe.

32
GLAZIUM FACADES P.L. CALCULATION SHEET
Subject - Design calculations of Spider Glazing

Anchor fastener Design for 'F' type bracket

1. Fastener at glass bottom bracket


Hilti anchor fastener specification = HSA-R M10x98

Hd = 2.75 kN

Md = 0.65 kN-m

2. Fastener at glass top bracket


Hilti anchor fastener specification = HST3-R M10x100

Hd = 2.75 kN

Md = 0.65 kN-m

Calculations of hilti fastener has been enclosed herewith.

33
HILTI REPORT PAGES ARE MISSING.
HOWEVER WE HAVE CHECKED FROM
OUR END & ITS FOUND OK.

34
35
36
37
HILTI REPORT PAGES ARE MISSING.
HOWEVER WE HAVE CHECKED FROM
OUR END & ITS FOUND OK.

38
39
40
41

You might also like