You are on page 1of 1

HESSIAN BAGS FILLED

DIMENSION TABLE WITH SOIL MIX


( SEE NOTE 2 )
NAIL HEAD SIZE
REINFORCEMENT
(mm) THE VOID BETWEEN THE
HESSIAN BAGS TO BE
400 x 400 3B16 U BARS BOTHWAYS
TAMPED WITH SOIL PRIOR
600 x 600 3B16 U BARS BOTHWAYS TO PLACING OF EROSION
800 x 800 4B16 U BARS BOTHWAYS CONTROL MAT

GMS 75 x 75 x 3L ( FOR 600 MIN. 8 DIA. HOT DIP


AND 800 NAIL HEADS ONLY ) GALVANIZED ANCHOR
BOLT WITH NUT AND
WASHER WITH MIN.
FINISHED SLOPE PROFILE
79 EMBEDMENT DEPTH

NON-BIODEGRADABLE EROSION CONTROL


MAT WITH SURFACE HYDROSEEDED

50
.
EQ
C
LO
B
>

WIRE MESH
D
EA

( IF NECESSARY )
H

D
IL

EA
A
N

H
0

IL
80

MIN. 12 DIA. STAINLESS 50


N
0

STEEL ANCHOR BOLT


60

( SEE DETAIL ’A’ IN STD.


DRG. NO. C2511 / 2 )

25
.
EQ

0
M
D

IN
EA

.
H
IL
A
N
0
40

10 DIA. HOLE FOR PASSING


.

THROUGH OF WIRE FOR NAIL


EQ
0
18

LENGTH CHECKING ( WIRE


NOT SHOWN FOR CLARITY )
10
0
90

> NA
IL
50
M
IN
.

INTERSECTION OF NAIL BAR


AND REINFORCEMENT BAR AT
CENTRELINE OF BLOCK

THIN NUT ( SEE NOTE 4 )


80 x 80 x 5 Tk GMS
PLATE WITH 14 DIA
HOLE AT CENTRE 150 x 150 x 20 Tk
50

GMS PLATE

REINFORCEMENT
( REFER TO DIMENSION TABLE )

GRADE 30 / 20 CONCRETE OR
30 MPa SPRAYED CONCRETE
SOIL NAIL HEAD

TYPICAL SECTION OF RECESSED SOIL NAIL HEAD


NOTES: FOR HYDROSEEDING SURFACE WITH NON-BIODEGRADABLE
1. ALL DIMENSIONS ARE IN MILLIMETRES. EROSION CONTROL MAT OR / AND WIRE MESH
SCALE 1 : 5
2. FOR EVERY 200 x 200 x 100 Tk BAG
OF SOIL MIX, INCORPORATE 50 g OF
F DETAILS FOR ANCHOR BOLT REVISED. Original Signed 07.2018
PRE-PLANTING FERTILIZER AND 10 g OF
WATER RETAINING CRYSTALS. E NOTE 4 ADDED. Original Signed 04.2016

D MINOR AMENDMENT. Original Signed 06.2015


3. B DENOTES GRADE 500B RIBBED
REINFORCEMENT. DRAWING TITLE AND SUB-TITLE
C Original Signed 03.2015
AMENDED.
4. FOR SOIL NAIL HEADS CONSTRUCTED BY
B BAR NOTATIONS AMENDED. Original Signed 12.2014
2-STAGE SPRAYED CONCRETE ACCORDING TO
GENERAL SPECIFICATION FOR CIVIL DETAILS FOR ANCHOR BOLT REVISED.
A Original Signed 08.2007
ENGINEERING WORKS, THE THIN NUT SHALL BE OMITTED. GMS ADDED FOR STEEL WORKS.
REF. REVISION SIGNATURE DATE

CIVIL ENGINEERING AND


TYPICAL DETAILS OF
DEVELOPMENT DEPARTMENT
SOIL NAIL SCALE AS SHOWN DRAWING NO.

(SHEET 4 OF 8) DATE DEC 2005 C2106 / 4F


¤V¶u⁄{ We Engineer Hong Kong’s Development