Professional Documents
Culture Documents
A]
www.lg.ca [For Canada]
MODEL : DLE5977W/DLG5988W
DLE5977B/DLG5988B
DLE3777W/DLG3788W
! WARNING !
To avoid personal injury, disconnect power before servicing this product. If electrical power is required
for diagnosis or test purposes, disconnect the power immediately after performing the necessary checks.
IMPORTANT
Electrostatic Discharge (ESD)
Sensitive Electronics
ESD problems are present everywhere. ESD may damage or weaken the electronic
control assembly. The new control assembly may appear to work well after repair is
finished, but failure may occur at a later date due to ESD stress.
Use an anti-static wrist strap. Connect wrist strap to green ground connection point or unpainted
metal in the appliance.
- OR -
Touch your finger repeatedly to a green ground connection point or unpainted metal
in the appliance.
Before removing the part from its package, touch the anti-static bag to a green ground connection
point or unpainted metal in the appliance.
Avoid touching electronic parts or terminal contacts; handle electronic control assembly by edges only.
When repackaging failed electronic control assembly in anti-static bag, observe above instructions.
1. SPECIFICATIONS ..................................................................................................................4
DLE5977W/DLG5988W/DLE5977B/DLG5988B
DLE3777W/DLG3788W
g f
a. External ground connector
b. Neutral grounding wire (white)
a. 3-wire receptacle (NEMA type 10-30R) c. Center silver-colored terminal block screw
b. 3-wire plug d. Neutral wire (white or center wire)
c. Neutral prong e. 3/4 in. (1.9 cm) UL-listed strain relief
d. Spade terminals with up turned ends
e. 3/4 in. (1.9 cm) UL approved strain relief
f. Ring terminals
g. Neutral (white or center wire)
3. Connect the other wires to outer terminal block
1. Loosen or remove center terminal block screw. screws. Tighten screws.
2. Connect neutral wire (white or center wire) of 4. Tighten strain relief screws.
power supply cord to the center, silver colored 5. Insert tab of terminal block cover into slot of
terminal screw of the terminal block. Tighten dryer rear panel. Secure cover with hold-down
screw. screw.
b
c
a
a. External ground connector - Dotted line
shows position of NEUTRAL ground wire
before being moved to center terminal block
screw
b. Center silver-colored terminal block screw
c. White wire of harness
10
2
5
3
11
COTTON/ MID
(Normal) 55min Saturation 66±4°C (5min) 47±5°C
TOWELS HIGH
ULTRA ULTRA
(Normal) 34min Saturation 45±3°C (5min) 38±5°C
DELICATE LOW
Manual (MID
FRESHEN UP - 20min Saturation (66±5°C) (5min) (47±5°C) 3Hr
Dry ** HIGH)
No
AIR DRY - - 30min Saturation N/A N/A
heater
12
! CAUTION When checking the Component, be sure to turn the power off, and do voltage discharge sufficiently.
13
valve 2
11. Igniter Measure resistance of terminal Resistance value : 100~800Ω • Gas type
to terminal
14
15
NOTE When checking Component, be sure to turn Power off, then do voltage discharge sufficiently.
Contact On / Off by Centrifugal Switch
Centrifugal switch
Centrifugal switch (Pull Drive forward)
16
17
18
Pressing the
CHECKING
“START/PAUSE” DISPLAY CHECKING POINT REMARK
ACTION
button
Won’t power up See test 1
Electric control Defective LED Display : See page
&
None Thermistor open
Temperature See test 2
sensor Thermistor close
Motor runs See test 3
70 ~ 239 Displays Moisture Sensor Operation:
Motor Measured If moisture sensor is contacted with
Once Moisture Value. damp cloth. The display number is See test 4
below 180, in normal condition.
ELECTRIC TYPE ELECTRIC TYPE : Heater runs
Motor + Heater 1 (2700W) GAS TYPE : GAS Valve runs Gas valve
Current Temp.
Twice GAS TYPE (Display the Temperature of See test 7
Motor + Valve Inside drum.)
ELECTRIC TYPE
Motor + Heater 1
Current Temp.
3 times +Heater 2 (5400W)
(5 ~ 70)
GAS TYPE
Motor Type
4 times Control Off Auto Off
During check, Motor & Heater Off + Lamp On + Door switch See test 6
If the door is open. Buzzer beeps seven times Lamp
• Press Start button 1 time and then open the
door. Proceed again with the step 1(by pressing
start 1 time), step 2(by pressing start 2 times),
step 3(by pressing start 3 times) and step 4(by
During check, Motor on & Heater pressing start 4 times) in sequence.
If the door is closed. Off + Lamp Off 70 ~ 239 • Press Start 2 times and then open the door. Proceed
again from the step 1 all the way to the step 4.
• Press Start 3 times and then open the door
Proceed with the step 1 and skip the step 2 and
press step 3 twice and finish with step 4 by
making sure the all the electric devices shut off
in the end.
19
YES
YES
N(White)
Check if the Controller wire is
L (Black) L (Led)
disconnected.
Check if Terminal Block and Power Cord
• Reconnect the
are connected (Check Plug ). NO
controller.
- Does Power Cord N( Natural) line match
to Terminal Center N(Natural) line?
YES
Replace controIler.
20
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
Caution (When discharging, contact the metal plug of Power cord with the Ground.)
NO
YES
Air TEMP.[°F (°C)] RES. [kΩ] Air TEMP.[°F (°C)] RES. [kΩ] Air TEMP.[°F (°C)] RES. [kΩ]
50°F (10°C) 18.0 90°F (32°C) 7.7 130°F (54°C) 2.9
60°F (16°C) 14.2 100°F (38°C) 6.2 140°F (60°C) 3.0
70°F (21°C) 11.7 110°F (43°C) 5.2 150°F (66°C) 2.5
80°F (27°C) 9.3 120°F (49°C) 4.3 160°F (71°C) 2.2
21
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
Caution (When discharging, contact the metal plug of Power cord with earth line.)
Trouble Symptom Drum will not rotate; No fan will function; No Heater will work.
Measurement Condition Turn the Dryer’s Power Off, then measure resistance.
Idler Switch Lever Idler Switch Is resistance below 1Ω between Idler Switch • Replace Idler
terminals? NO Switch.
YES
22
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
Caution (When discharging, contact the metal plug of Power cord with earth line.)
Trouble Symptom Degree of dryness does not match with Dry Level.
Measurement Condition Turn the Dryer’s Power Off, then measure resistance.
Metal or Wire
Normal Condition
Table 2. IMC Ratio and Display Value / Voltage (IMC : Initial Moisture Content)
23
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
Caution (When discharging, contact the metal plug of Power cord with earth line.)
Door Opening is not sensed.(During operation, when opening Door, Drum motor and
Trouble Symptom Heater run continuously; Door Close is not sensed.
(Drum motor will not operate. Display will flash at 0.5 second intervals.)
NO
• Check Lamp.
(When opening
Measure while Door is open. Check if Lamp, replace then
resistance is 300~60Ω between “WH3- ”
(White wire) and “RD3- ” (Black wire) NO measure again.)
Connector WH3, RD3 after taking WH3, RD3 • Door switch
out from Controller. Check(Refer to
Component
YES testing.)
NO
YES
Check Controller.
Check Harness-linking connector.
24
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
Caution (When discharging, contact the metal plug of Power cord with earth line.)
YES
YES
YES
Check Controller.
Check Harness-linking Connector.
25
Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock.
NO
Valve 1
When measuring Valve 1 voltage, • Check thermostat
More than AC 90V? NO Hi limit Safety
YES
NO
• Harness check
• Controller change
26
! Warning After Natural Gas Setting, applying Propane Gas Orifice or wrong use of Natural Gas
Orifice will result in fire. Conversion must be made by a qualified technician.
Initially, Natural Gas mode is set. Propane Gas Orifice is on sale as a Service
Part to authorized servicers only.
Full open
“Change screw”
Close
“Change screw”
27
“VALVE 1” ON
IGNITE ON
IGNITE NO
TEMPERATURE ABOUT
370”F
YES
“VALVE 2” ON
NO
GAS IGNITION
START
VALVE 1 ON
IGNITER ON OFF
FRAME
CLOSE OPEN
DETECT
VALVE 2 OFF ON
GAS IGNITION
28
29
30
31
4. Remove 4 screws.
5. Disassemble the Tub Drum [Front].
32
PORTION “A” 2. Detach and remove the bottom, left or right side
knockout as desired.
33
34
35
A210
A130
A120
A110
36
A700 A800
A390
A330
A600
A320 A500
A310
A400
A410 A460
37
K120
K140
K100
K130
K250
K310
K330 K320 K340
K221
K210
K250
K550 K560
K610
K240
F140
K510 K520 K640
F130
F110 K650
38
K120
K140
K100
K130
K250
K310
K330 K320 K340
K221
K210
K250
K550 K560
K610
K240
M160
K650
M171
M170
M210
M140 M230
M110
M190
39
40
41