You are on page 1of 23

CDUC Power Generation Pricing Tool

Version: V. 6.3b
Issue Date: 01/08/2019
Effective Date: 01/04/2020

When first opening up the tool, if you get a yellow pop-up box that says "Enable Content", click on that. You will need macros enabled

to fully use the tool.

Before making any selections, rename the spreadsheet as something else (example: project number). You must always start with this

copy of the tool because each selection can change the available selections after it.

If you are trying to make a selection from a drop down box in a cell and the pop-up message is in the way, scroll up or down in the

spreadsheet and the pop-up box will move out of the way.

This tool only shows the available options that have been released by engineering and quoted in the system. If there is an option that

you would like and it is not available in the pricing tool, then contact Cummins CDUC sales team.

● Start on the "Engine Selection" tab and select your engine model.

On the "Optional Selections" tab, start in the top left corner and work your way from top to bottom, left to right. ALL blue boxes must

be filled in prior to any pricing being shown.

● Items highlighted in GREEN are standard and those highlighted in RED are not available at this time.

● Prices are subject to change without notice or upon confirmation of P.O.

● "Deliveries subject to change based on availability at time of order receipt. See the Natural Gas (NG) Lead-time
bulletin published by the Power Generation team bi-weekly."

● Any suggestion for future pricing tool improvements, please email to Broc Goldschmidt at kp937@cummins.com
V. 6.3b
Engine Selection

Natural Gas 60Hz Demand Response Regulated


New Model Number Old Model Number kW (kVA) Engine Emissions Fuel Type UL2200 Selection
C550N6 - 500 (625) GTA38E US NSPS Certified NG YES
C650N6 - 600 (750) GTA50E US NSPS Certified NG YES
C750N6 - 700 (875) GTA50E US NSPS Certified NG YES
Natural Gas 60Hz Standby Regulated (w/ Catalyst)
New Model Number Old Model Number kW (kVA) Engine Emissions Fuel Type UL2200 Selection
GFPA 140 (175) PSI8.8 US NSPS Certified Propane Vapor NO
GFPA 150 (188) PSI8.8 US NSPS Certified NG / Dual Fuel NO
C200N6 GFPC 200 (250) PSI11 US NSPS Certified NG / Dual Fuel NO
C250N61 - 250 (312) GTA855E US NSPS Certified NG YES
1
C300N6 - 300 (375) GTA855E US NSPS Certified NG YES
C500N61 - 335 (419) GTA38E US NSPS Certified Propane Vapor YES
C350N6 GFEB 350 (438) KTA19SLB US NSPS Certified NG YES
C400N61 - 400 (500) GTA28E US NSPS Certified NG YES
C450N61 - 450 (563) GTA28E US NSPS Certified NG YES
C500N6B1 - 500 (625) GTA28E US NSPS Certified NG YES
C550N61 - 550 (688) GTA38E US NSPS Certified NG YES
C600N61 - 600 (750) GTA50E US NSPS Certified NG YES
C650N61 - 650 (812) GTA50E US NSPS Certified NG YES
C750N61 - 750 (938) GTA50E US NSPS Certified NG YES
Diesel 60Hz Prime Mobile Regulated
New Model Number Old Model Number kW (kVA) Engine Emissions Fuel Type UL2200 Selection
C130D6B - 120 (150) QSB4.5 TIV US (Mobile) Non-Road Tier IV Final Diesel NO
C275D6D - 260 (312) QSL 9 TIV US Non-Road Tier IV Final Diesel NO
Diesel 60Hz Standby Regulated
New Model Number Old Model Number kW (kVA) Engine Emissions Fuel Type UL2200 Selection
C275D6D - 275 (343) QSL 9 TIV US Non-Road Tier IV Final Diesel NO
C400D6B - 400 (500) QSZ13 US NSPS Stationary Emergency T3 Diesel YES
1
Factory certified product with EICS fuel control system
Blue Boxes = Mandatory Selections Orange Boxes = Optional Selections V. 6.3b DN Net Price = 164251 DN List Price = $273751,2

** Start in top left corner and work your way from top to bottom, left to right. ** C760N6 GTA50 NATURAL GAS GENERATOR SET

Select Fuel System Select Warranty Select CB Mounting Option Generator Options Enclosure Options Select Additional Testing / Reports
Natural Gas 1 yr Base Std PMG Select Color Select Material Ext. Standby Load Bank 1 hour
Heater Onan Green Galvaneal Ext. Standby Load Bank 2 hour

Select Certification (UL,CSA) Select PCC 3300 Mode Select CB Mounting Side RTD's Select Lights Select Load Center Ext. Standby Load Bank 4 hour

Standard Stand Alone RIGHT Genset Options NONE NONE Ext. Standby Load Bank 8 hour

Drain Extensions (Oil & Coolant) Select Exhaust Fan Select Perf Liner Witness Test

Select Volt_Ph_Temp Rise Select # of Circuit Breakers Select Coolant Heater HMI Heater NONE NONE Standard Test Report

277/480_3ph_125C 1 NONE Vibration Isolators Select Any Enclosure Options Below


Audible Alarm MVD Intake 5kW Heater

Select Genset Controller Select Circuit Breaker #1 Enter Project Name Relay Kit MVD Outlet GFCI Receptacles

PCC_3300 TM_60A_80% GFI Indicator GVS Outlet External GFCI Box Circuit Breaker Alternative Mounting Options
Remote Annunciator Touch Up Paint Brush Bottle 3-Way Light Switches Standard Right Side (1) H or J Frame Breaker
Select Side for Controls Select Circuit Breaker #2 Enter PO Number External E-Stop 120 MPH High Wind Bracing Touch Up Paint Spray Can Left Side No Breaker
LEFT Flexible Fuel Connector Drip Rails Option 1 Right Side
Fuel Strainer Select Below Exhaust Option for Open Sets Only Left Side
Select Cooling System Select Circuit Breaker #3 Select Batteries Bargraph - Analog Rain Cap Option 2 Right Side
RADIATOR NONE Aux 101 Module Select to Remove for Export Sets Only Left Side
Expansion Module Remove Catalyst Remove Gas Train Option 3 Right Side
Select Enclosure Select Circuit Breaker #4 Select Battery Charger Oil Level Maintainer Left Side
NONE NONE Battery Heater Select Either of the Circuit Breaker Options Below
Oil Breather Heater Shunt Trip Auxillary Contacts CB1 Frame H TM_60A_80%
Select Silencer Grade Select Circuit Breaker #5 Select Engine Oil Heater Battery Disconnect

CRITICAL NONE Crankcase Breather (CV sys) Select Diesel Options Below
Field Server (BacNet) Fuel Tank Subbase 24 HR UL 142 QSB 4.5 Trailer

Select Silencer Material Select Circuit Breaker #6 Enter Qty of Extra Manuals Remote HMI Air Shutoff Valve

CARBON STEEL 0 Secondary Gas Regulator Left Maintenance (Remote Oil Filter)
Dual Solenoid
Drain Engine Fluids before shipment
01/04/2020
V. 6.3b

Bill of Material
Project Name:

PRICING: Shipping Method


Dist List Price = $273.751,20 Flatbed
Dist Net Price = $164.251,00
Dist Cost Adders = $0,00 FLATBED REQUESTED?
Freight Cost = $0,00 NO
Total Dist Net Cost = $164.251,00

Item Description Quantity


C760N6 Genset - Spark Ign, Natural Gas, 60Hz, 650kW 1
ENG GTA50, 1031 HP, 8.5:1 1
A122-2 Duty Rating - Prime Power 2
C002-2 Natural Gas 1
B267-2 Generator - HCI504F (ADS #308), 60Hz, Winding 311 - 12 Wire, 125C, 0,8pf 1
R002-2 Voltage - 277/480, 3ph 1
B184-2 Exciter / Regulator - PMG, 3 Phase Sensor 1
H704-2 Set Control - Power Command 3.3 1
H609-2 Controls Facing Left 1
E082-2 Radiator Cooled 1
H389-2 Shutdown - Low Coolant Level 1
E098-2 Sightglass on Radiator 1
A366-2 Engine Governor - Electronic, Isochronous Only 1
A334-2 Engine Starter - 24 VDC Motor 1
A333-2 Battery Charging Alternator - Normal Output 1
D036-2 Engine Air Cleaner - Heavy Duty 1
H706-2 Lube Oil, Engine Filled Prior to Shipment 1
H669-2 Anti-Freeze - 50/50 Mix, System Filled Prior to Shipment 1
A466-2 Critical Grade Silencer, Carbon Steel 1
H606-2 Bargraph - AC Analog Meters 2
L050-2 Manuals in English 1
F065-2 Battery Rack 1
M160-2 Circuit Breaker - TM_60A_80%, 600/525V 1
G002-7 Genset Warranty - Prime Power 1 year / unlimited hours 1
1
To enter additional line items to appear on the BOM, enter them here. If you would also like a cost
associated with the item, add it here and it will roll up into the final DN price.

Cost Description Quantity


01/04/2020
V. 6.3b

C760N6 GTA50 NATURAL GAS GENSET


Project:

ENGINE DATA:
FR Selection = GEN - CONT - FR60376 - NG - WATER/AIR - EXPORT ONLY
Rating Type = Prime Engine HP = 1031 HP
Fuel Type = Natural Gas kWm = 769
Catalyst = N/A Compression Ratio = 8.5:1
Warranty = 1 yr Base

GENERATOR DATA:
Generator = HCI504F (ADS #308), Winding 311 - 12 Wire, 277/480 Volts, 125C, 60 Hz, 3ph, 0,8pf, SAE #0, #18
kW = 660 kW Exciter / Regulator = PMG
Efficiency % = #N/A Generator Heater = NONE SELECTED
Warranty = 1 yr Base Generator RTD's = None Selected

GENSET DATA:
Published kWe = 650 kVA = 813 Frequency = 60 Hz
Voltage = 480 kVAR = 488 Phases = 3ph
Power Factor = 0,8 CT Ratio = 2366:1 CT Amperage = 1
FLA = 977 Overall Schematic = A042H086

ENCLOSURE DATA:

OPTIONS SELECTED:
Generator Controls = PCC_3300 on LEFT Cooling System = RADIATOR
Low Coolant Level Alarm = SHUTDOWN Bargraph = Standard
Exhaust System = CRITICAL, CARBON STEEL Circuit Breaker 1 = TM_60A_80%
01/04/2020
V. 6.3b

C760N6 GTA50 Natural Gas Genset / FR60376 / NON-REG


Project Name:

Description Part Number List Price


Base Genset C760N6 GTA50 NATURALGAS $ 378.520,00
Battery Rack - $ -
Circuit Breaker #1 TM_60A_80% $ 1.690,00
Circuit Breaker #2 0 $ -
Circuit Breaker #3 0 $ -
Circuit Breaker #4 0 $ -
Circuit Breaker #5 0 $ -
Circuit Breaker #6 0 $ -
Genset Total Cost = $ 380.210,00
01/04/2020
V. 6.3b
Purchase Order

Distributor Information:
Dist. P.O. Number: Enter P.O. # on (Optional Selections) tab
Dist. Name:
Project Name: Enter Project # on (Optional Selections) tab
Sales Person:
Requested Ship Date:
Shipping Method:

Ship To Address: Additional Contacts:

Genset Ordered: C760N6 GTA50 NATURAL GAS GENSET


Total Order Price: $164.251,00

Order Information:
Engine Model: GTA50
Fuel Rating: FR60376
Volts/Phase/Temp: 277/480_3ph_125C
Generator: HCI504F (ADS #308)
Power Factor: 0,8
Genset Controller: PCC_3300
CT Amperage: 1
Cooling System: RADIATOR
Enclosure/Base: NONE
Exhaust Grade: CRITICAL
Exhaust Material: CARBON STEEL
Controls Side: LEFT
Warranty: 1 yr Base
Certifications: Standard
Gas Train: NONE
# of Circuit Breakers: 1
Paralleling Option: Stand Alone
CB1: TM_60A_80%
CB Mounting Option: Std
CB Mounting Side: RIGHT
PMG: Selected
Battery Rack: Selected
Bargraph: Selected
Catalyst: Selected

Additional Comments:
NATURAL GAS SHIPPING QUOTE FORM 01/04/2020
V. 6.3b

WORK ORDER(S) # :

PROJECT NAME / # :

ENGINE MODEL : GTA50

ENGINE SERIAL # :

GENSET MODEL : C760N6

ENCLOSURE TYPE : NONE

CUSTOMER NAME :

CUSTOMER PO # :

SHIPMENT VALUE : $ 164.251,00

SHIPPING METHOD :

SITE CONTACT NAME :

SITE CONTACT NUMBER :

SITE NAME / SITE PROJECT # :

QUANTITY OF LOOSE SKIDS :

PC / PM :

DELIVERY ADDRESS :

CARRIER : PRICE :

CARRIER : PRICE :

CARRIER : PRICE :

CARRIER : PRICE :

CARRIER : PRICE :

CARRIER : PRICE :

DELIVERY NOTES :
01/04/2020

SOUND DATA
C760N6
60Hz

Sound Pressure Levels @ 7 meters dB(A)


Position (Note 1) 8 Position
Configuration
1 2 3 4 5 6 7 8 Average

Open Set Infinite Exhaust #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Open Set Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

F001 Weather Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Level 1.0 Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Level 2.0 Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Sound Power Levels


Octave Band Center Frequency (Hz) Sound
Configuration
63 125 250 500 1000 2000 4000 8000 Power Level

Open Set Infinite Exhaust #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Open Set Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

F001 Weather Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Level 1.0 Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Level 2.0 Mounted Muffler #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A #N/A

Notes:
1. Position 1 faces the Generator front per ISO 8528-10. The positions proceed around the generator set in a counter-clockwise direction in
45° increments. All positions are at 7m (23 ft) from the surface of the generator set and 1.2m (48") from floor level.
2. Sound levels are subject to instrumentation, measurement, installation and manufacturing variability.
3. Data based on 100% rated load with standard radiator - fan package.
4. Sound data for generator set with infinite exhaust does not include exhaust noise.
5. Sound pressure levels are measured per ANSI S1.13 and ANSI S12.18 as applicable.
6. Reference sound pressure is 20 µPa.
7. Sound Power Levels per ISO 3744 and ISO 8528-10 as applicable.
8. Reference power is 1 pW (10"12 W).
9.

** Data and specification subject to change without notice **


Feature Code Old Feature Code Circuit Breaker Look Up Trip Type Amps Frame Rating CB Part Number CB Manufacturer P/N Cut Sheet Reference Drawing NG Accessories from PowerSuite
M158-2 KS70-2 TM_50A_80% Thermal Mag 50 H 80 320-2346-18 HGL36050 HGL36050 320-2346 3" Solenoid
M160-2 KS69-2 TM_60A_80% Thermal Mag 60 H 80 320-2346-17 HGL36060 HGL36060 320-2346 Battery Charger
M162-2 KS68-2 TM_70A_80% Thermal Mag 70 H 80 320-2346-10 HGL36070 HGL36070 320-2346 CSA Flex
M164-2 KS67-2 TM_80A_80% Thermal Mag 80 H 80 320-2346-09 HGL36080 HGL36080 320-2346 Fuel Filter
M166-2 KS66-2 TM_90A_80% Thermal Mag 90 H 80 320-2346-08 HGL36090 HGL36090 320-2346 Fuel Flex
M168-2 KS65-2 TM_100A_80% Thermal Mag 100 H 80 320-2346-07 HGL36100 HGL36100 320-2346 Fuel Pressure
M171-2 KS64-2 TM_125A_80% Thermal Mag 125 H 80 320-2346-06 HGL36125 HGL36125 320-2346 ASCO Fuel Solenoid
M173-2 KS63-2 TM_150A_80% Thermal Mag 150 H 80 320-2346-05 HGL36150 HGL36150 320-2346 Kim Hot Start Heater
M175-2 KS62-2 TM_175A_80% Thermal Mag 175 J 80 320-2347-04 JGL36175 JGL36175 320-2347 Silencer_Nelson 400
M177-2 KS61-2 TM_200A_80% Thermal Mag 200 J 80 320-2347-03 JGL36200 JGL36200 320-2347 Battery
M179-2 KS60-2 TM_225A_80% Thermal Mag 225 J 80 320-2347-02 JGL36225 JGL36225 320-2347 Oil Pan Heater_PSI
M181-2 KS59-2 TM_250A_80% Thermal Mag 250 J 80 320-2347-01 JGL36250 JGL36250 320-2347 Solenoid_UL_CSA
M101-2 CNPCB1 Li_60A_80% Li 60 H 80 A042A618 HGL36060U31X HGL36060U31X A042A632 Strainer_1 1/4"
M103-2 CNPCB2 Li_100A_80% Li 100 H 80 A042A620 HGL36100U31X HGL36100U31X A042A632 Strainer_2"
M106-2 CNPCB3 Li_800A_80% Li 800 P 80 320-2182-01 PJL36080U31F PJL36080U31F 320-2182 Strainer_3"
M108-2 CNPCB4 Li_1200A_80% Li 1200 P 80 320-2183-01 PJL36120U31E PJL36120U31E 320-2183 Watlow Heaters
M113-2 CNPCB5 LSi_60A_80% LSi 60 H 80 A042A626 HGL36060U33X HGL36060U33X A042A632
M115-2 CNPCB6 LSi_100A_80% LSi 100 H 80 A042A628 HGL36100U33X HGL36100U33X A042A632
M117-2 CNPCB7 LSi_150A_80% LSi 150 H 80 A042G041 HGL36150U33X HGL36150U33X A042A632
M119-2 KX14-2 LSi_250A_80% LSi 250 L 80 A059G881 JGL36250U33X JGL36250U33X A044T469
M121-2 KM41-2 LSi_300A_80% LSi 300 L 80 A059G884 LGL36400U33X LGL36400U33X A044T469
M122-2 KM42-2 LSi_350A_80% LSi 350 L 80 A059G886 LGL36400U33X LGL36400U33X A044T469
M123-2 KM43-3 LSi_400A_80% LSi 400 L 80 A059G876 LGL36400U33X LGL36400U33X A044T469
M125-2 KM44-2 LSi_450A_80% LSi 450 L 80 A059G887 LGL36600U33X LGL36600U33X A044T469
M126-2 KM45-2 LSi_500A_80% LSi 500 L 80 A059G885 LGL36600U33X LGL36600U33X A044T469
M127-2 KM46-2 LSi_600A_80% LSi 600 L 80 A059G879 LGL36600U33X LGL36600U33X A044T469
M129-2 KS45-2 LSi_800A_80% LSi 800 P 80 320-2182-01 PJL36080U33F PJL36080U33F 320-2182
M131-2 KP89-2 LSi_1200A_80% LSi 1200 P 80 320-2183-01 PJL36120U33E PJL36120U33E 320-2183
M136-2 CNPCB8 LSiG_60A_80% LSiG 60 H 80 A042A641 HGL36060U44X HGL36060U44X A042A632
M138-2 CNPCB9 LSiG_100A_80% LSiG 100 H 80 A042A643 HGL36100U44X HGL36100U44X A042A632
M140-2 CNPCB10 LSiG_150A_80% LSiG 150 H 80 A042A645 HGL36150U44X HGL36150U44X A042A632
M142-2 KX14-2 LSiG_250A_80% LSiG 250 J 80 A042A647 JGL36250U44X JGL36250U44X A042A634
M145-2 KM43-3 LSiG_400A_80% LSiG 400 L 80 A042A649 LGL36400U44X LGL36400U44X A042A636
M147-2 KM46-2 LSiG_600A_80% LSiG 600 L 80 A042A651 LGL36600U44X LGL36600U44X A042A636
M149-2 KS45-2 LSiG_800A_80% LSiG 800 P 80 320-2182-01 PJL36080U44F PJL36080U44F 320-2182
M152-2 KP89-2 LSiG_1200A_80% LSiG 1200 P 80 320-2183-01 PJL36120U44E PJL36120U44E 320-2183
M159-2 CNPCB11 TM_50A_100% Thermal Mag 50 H 100 A042A605 HGL36050C HGL36050C A042A622
M161-2 CNPCB12 TM_60A_100% Thermal Mag 60 H 100 A042A606 HGL36060C HGL36060C A042A622
M163-2 CNPCB13 TM_70A_100% Thermal Mag 70 H 100 A042A607 HGL36070C HGL36070C A042A622
M165-2 CNPCB14 TM_80A_100% Thermal Mag 80 H 100 A042A608 HGL36080C HGL36080C A042A622
M167-2 CNPCB15 TM_90A_100% Thermal Mag 90 H 100 A042A609 HGL36090C HGL36090C A042A622
M169-2 CNPCB16 TM_100A_100% Thermal Mag 100 H 100 A042A610 HGL36100C HGL36100C A042A622
M170-2 CNPCB17 TM_110A_100% Thermal Mag 110 H 100 A042A611 HGL36110C HGL36110C A042A622
M172-2 CNPCB18 TM_125A_100% Thermal Mag 125 H 100 A042A612 HGL36125C HGL36125C A042A622
M174-2 CNPCB19 TM_150A_100% Thermal Mag 150 H 100 A042A613 HGL36150C HGL36150C A042A622
M176-2 CNPCB20 TM_175A_100% Thermal Mag 175 J 100 A042A614 JGL36175C JGL36175C A042A630
M178-2 CNPCB21 TM_200A_100% Thermal Mag 200 J 100 A042A615 JGL36200C JGL36200C A042A630
M180-2 CNPCB22 TM_225A_100% Thermal Mag 225 J 100 A042A616 JGL36225C JGL36225C A042A630
M182-2 CNPCB23 TM_250A_100% Thermal Mag 250 J 100 A042A617 JGL36250C JGL36250C A042A630
M102-2 CNPCB24 Li_60A_100% Li 60 H 100 A042A619 HGL36060CU31X HGL36060CU31X A042A676
M104-2 CNPCB25 Li_100A_100% Li 100 H 100 A042A621 HGL36100CU31X HGL36100CU31X A042A676
M105-2 CNPCB26 Li_600A_100% Li 600 P 100 A042A623 PGL36060CU31A PGL36060CU31A A042A678
M107-2 KS45-2 Li_800A_100%_RIGHT Li 800 PP 100 179-3488-05 PJL36080U31F PJL36080U31F 320-2182
M107-2 KS45-2 Li_800A_100%_LEFT Li 800 PP 100 179-3488-06 PJL36080U31F PJL36080U31F 320-2182
M109-2 KP88-2 Li_1200A_100%_RIGHT Li 1200 PP 100 179-3488-07 PJL36120U31E PJL36120U31E 320-2183
M109-2 KP89-2 Li_1200A_100%_LEFT Li 1200 PP 100 179-3488-08 PJL36120U31E PJL36120U31E 320-2183
M110-2 KP86-2 Li_1600A_100%_RIGHT Li 1600 R 100 179-3489-07 RLF36160U31F RLF36160U31F 320-2164
M110-2 KP87-2 Li_1600A_100%_LEFT Li 1600 R 100 179-3489-08 RLF36160U31F RLF36160U31F 320-2164
M111-2 KP84-2 Li_2000A_100%_RIGHT Li 2000 R 100 179-3489-09 RLF36200U31F RLF36200U31F 320-2164
M111-2 KP85-2 Li_2000A_100%_LEFT Li 2000 R 100 179-3489-10 RLF36200U31F RLF36200U31F 320-2164
M112-2 KP82-2 Li_2500A_100%_RIGHT Li 2500 R 100 179-3489-11 RLF36250U31F RLF36250U31F 320-2164
M112-2 KP83-2 Li_2500A_100%_LEFT Li 2500 R 100 179-3489-12 RLF36250U31F RLF36250U31F 320-2164
M114-2 CNPCB24 LSi_60A_100% LSi 60 H 100 A042A627 HGL36060CU33X HGL36060CU33X A042A676
M116-2 CNPCB25 LSi_100A_100% LSi 100 H 100 A042A629 HGL36100CU33X HGL36100CU33X A042A676
M118-2 CNPCB27 LSi_150A_100% LSi 150 H 100 A042A631 HGL36150CU33X HGL36150CU33X A042A676
M120-2 CNPCB28 LSi_250A_100% LSi 250 J 100 A042A633 JGL36250CU33X JGL36250CU33X A042A677
M124-2 CNPCB29 LSi_400A_100% LSi 400 L 100 A042A635 LGL36400CU33X LGL36400CU33X A042A736
M128-2 CNPCB26 LSi_600A_100% LSi 600 P 100 A042A637 PGL36060CU33X PGL36060CU33X A042A678
M130-2 KS45-2 LSi_800A_100%_RIGHT LSi 800 PP 100 179-3488-05 PJL36080U33F PJL36080U33F 320-2182
M130-2 KS45-2 LSi_800A_100%_LEFT LSi 800 PP 100 179-3488-06 PJL36080U33F PJL36080U33F 320-2182
M132-2 KP88-2 LSi_1200A_100%_RIGHT LSi 1200 PP 100 179-3488-07 PJL36120U33E PJL36120U33E 320-2183
M132-2 KP89-2 LSi_1200A_100%_LEFT LSi 1200 PP 100 179-3488-08 PJL36120U33E PJL36120U33E 320-2183
M133-2 KP86-2 LSi_1600A_100%_RIGHT LSi 1600 R 100 179-3489-07 RLF36160U33F RLF36160U33F 320-2164
M133-2 KP87-2 LSi_1600A_100%_LEFT LSi 1600 R 100 179-3489-08 RLF36160U33F RLF36160U33F 320-2164
M134-2 KP84-2 LSi_2000A_100%_RIGHT LSi 2000 R 100 179-3489-09 RLF36200U33F RLF36200U33F 320-2164
M134-2 KP85-2 LSi_2000A_100%_LEFT LSi 2000 R 100 179-3489-10 RLF36200U33F RLF36200U33F 320-2164
M135-2 KP82-2 LSi_2500A_100%_RIGHT LSi 2500 R 100 179-3489-11 RLF36250U33F RLF36250U33F 320-2164
M135-2 KP83-2 LSi_2500A_100%_LEFT LSi 2500 R 100 179-3489-12 RLF36250U33F RLF36250U33F 320-2164
M137-2 CNPCB24 LSiG_60A_100% LSiG 60 H 100 A042A642 HGL36060CU44X HGL36060CU44X A042A676
M139-2 CNPCB25 LSiG_100A_100% LSiG 100 H 100 A042A644 HGL36100CU44X HGL36100CU44X A042A676
M141-2 CNPCB27 LSiG_150A_100% LSiG 150 H 100 A042A646 HGL36150CU44X HGL36150CU44X A042A676
M143-2 CNPCB28 LSiG_250A_100% LSiG 250 J 100 A042A648 JGL36250CU44X JGL36250CU44X A042A677
M146-2 CNPCB29 LSiG_400A_100% LSiG 400 L 100 A042A650 LGL36400CU44X LGL36400CU44X A042A736
M148-2 CNPCB26 LSiG_600A_100% LSiG 600 P 100 A042A652 PGL36060CU44A PGL36060CU44A A042A678
M150-2 KS45-2 LSiG_800A_100%_RIGHT LSiG 800 PP 100 179-3488-05 PJL36080U44F PJL36080U44F 320-2182
M150-2 KS45-2 LSiG_800A_100%_LEFT LSiG 800 PP 100 179-3488-06 PJL36080U44F PJL36080U44F 320-2182
M153-2 KP88-2 LSiG_1200A_100%_RIGHT LSiG 1200 PP 100 179-3488-07 PJL36120U44E PJL36120U44E 320-2183
M153-2 KP89-2 LSiG_1200A_100%_LEFT LSiG 1200 PP 100 179-3488-08 PJL36120U44E PJL36120U44E 320-2183
M155-2 KP86-2 LSiG_1600A_100%_RIGHT LSiG 1600 R 100 179-3489-07 RLF36160U44F RLF36160U44F 320-2164
M155-2 KP87-2 LSiG_1600A_100%_LEFT LSiG 1600 R 100 179-3489-08 RLF36160U44F RLF36160U44F 320-2164
M156-2 KP84-2 LSiG_2000A_100%_RIGHT LSiG 2000 R 100 179-3489-09 RLF36200U44F RLF36200U44F 320-2164
M156-2 KP85-2 LSiG_2000A_100%_LEFT LSiG 2000 R 100 179-3489-10 RLF36200U44F RLF36200U44F 320-2164
M157-2 KP82-2 LSiG_2500A_100%_RIGHT LSiG 2500 R 100 179-3489-11 RLF36250U44F RLF36250U44F 320-2164
M157-2 KP83-2 LSiG_2500A_100%_LEFT LSiG 2500 R 100 179-3489-12 RLF36250U44F RLF36250U44F 320-2164
M144-2 CNPCB30 EMAX_250A_100% LSiG 250 L 100 A042C358 Z1SAUCBN200A0AAA27XX A042C357
M151-2 CNPCB31 EMAX_800A_100% LSiG 800 P 100 A042C359 Z1BCUFBN200A0AAA27XX Z1BCUFBN200A0AAA27XX A042C357
M154-2 CNPCB32 EMAX_1200A_100% LSiG 1200 P 100 A042C360 Z1BDUHBN200A0AAA27XX Z1BDUHBN200A0AAA27XX A042C357
A042H711 A042C357
A042J029 A042C357
TERMS AND CONDITIONS FOR SALE OF POWER GENERATION EQUIPMENT

These Terms and Conditions, together with the Quote, Sales Order and/or Credit Application on the front side, are
hereinafter referred to as this “Agreement” and shall constitute the entire agreement between the customer
(“Customer”) identified in this Agreement and Cummins and supersede any previous agreement or understanding
(oral or written) between the parties with respect to the equipment (“Equipment”) identified in this Agreement.

QUOTE TERM; SCOPE. The Quote is valid for 60 days. The price is firm provided drawings are approved and
returned within 60 days after submission and ship date is not extended beyond published lead times. Any delays
may result in escalation charges. A Sales Order for Equipment is accepted on hold for release basis. The Sales
Order will not be released and scheduled for production until written approval to proceed is received. The Quote is
limited to plans and specifications section set forth in the Quote. No other sections shall apply. Additional
requirements for administrative items may require additional costs. The Quote does not include off unit wiring, off
unit plumbing, offloading, rigging, installation, exhaust insulation or fuel, unless otherwise stated.

SHIPPING; DELIVERY. Equipment is quoted FOB origin, freight prepaid to first destination, unless otherwise
stated. For consumer and mobile products, freight will be charged to Customer. A reasonable storage fee, as
determined by Cummins, may be assessed if delivery of the Equipment is delayed, deferred, or refused by
Customer. Offloading, handling, and placement of Equipment and crane services are the responsibility of Customer
and not included in proposal, unless otherwise stated. All shipments are made within normal business hours,
Monday through Friday. Any delivery, shipping, installation, or performance dates indicated in this Agreement are
estimated and not guaranteed. Further, delivery time is subject to confirmation at time of order and will be in effect
after engineering drawings have been approved for production. Cummins shall use best efforts to meet estimated
dates, but shall not be liable for any delay in delivery, shipping, installation, or performance, however occasioned.
Cummins may deliver in installments. Unless otherwise agreed to, packaging method, shipping documents and
manner, route and carrier and delivery shall be as Cummins deems appropriate.

PAYMENT TERMS; CREDIT; RETAINAGE. If Customer has approved credit, as determined by Cummins,
payment terms are net thirty (30) days from the date of invoice unless otherwise specified in the Quote, without
deduction or setoff. If payment is not received when due, in addition to any rights Cummins has under the law and
charges that Cummins may levy against Customer under statute (including attorney fees and costs of collection),
Cummins may charge Customer eighteen percent (18%) interest annually, or the maximum amount allowed by law,
on late payments. Payment shall be due in advance if Customer does not have approved credit. Retainage is not
acceptable nor binding, unless required by statute or accepted and confirmed in writing by Cummins prior to
shipment.

TAXES; EXEMPTIONS. Unless otherwise stated, the Quote excludes all applicable local, state and federal sales
and/or use taxes, permits and licensing. Customer must provide a valid resale or exemption certificate prior to
shipment of Equipment or applicable taxes will be added to the invoice.

TITLE; RISK OF LOSS. Title and risk of loss for the Equipment shall pass to Customer with delivery made in
accordance with the delivery terms set forth above.
INSPECTION AND ACCEPTANCE. Customer shall inspect the Equipment upon delivery, before offloading, for
damage, defects, and shortage. Any and all claims which could have been discovered by such inspection shall be
deemed absolutely and unconditionally waived unless noted by Customer on the bill of lading. Where Equipment is
alleged to be non-conforming or defective, written notice of defect must be given to Cummins within three (3) days
from date of delivery after which time Equipment shall be deemed accepted. Cummins shall have a commercially
reasonable period of time in which to correct such non-conformity or defect. If non-conformity or defect is not
eliminated to Customer’s satisfaction, Customer may reject the Equipment (but shall protect the Equipment until
returned to Cummins) or allow Cummins another opportunity to undertake corrective action. In the event startup of
the Equipment is included in the services, acceptance shall be deemed to have occurred upon successful startup.

LIEN; SECURITY AGREEMENT. Customer agrees that Cummins retains all statutory lien rights. To secure
payment, Customer grants Cummins a Purchase Money Security Interest in the Equipment. If any portion of the
balance is due to be paid following delivery, Customer agrees to execute and deliver such security agreement,
financing statements, deed of trust and such other documents as Cummins may request from time to time in order
to permit Cummins to obtain and maintain a perfected security interest in the Equipment; or in the alternative,
Customer grants Cummins a power of attorney to execute and file all financing statements and other documents
needed to perfect this security interest. Cummins may record this Agreement, bearing Customer's signature, or
copy of this Agreement in lieu of a UCC-1, provided that it shall not constitute an admission by Cummins of the
applicability or non-applicability of the UCC nor shall the failure to file this form or a UCC-1 in any way affect, alter,
or invalidate any term, provision, obligation or liability under this Agreement. The security interest shall be
superseded if Customer and Cummins enter into a separate security agreement for the Equipment. Prior to full
payment of the balance due, Equipment will be kept at Customer’s location noted in this Agreement, will not be
moved without prior notice to Cummins, and is subject to inspection by Cummins at all reasonable times.

CANCELLATION; CHARGES. If Customer cancels all or a portion of this Agreement after its release to Cummins,
Customer may incur a cancellation charge in accordance with current Cummins policy which is available upon
request, in addition to the actual, non-recoverable costs incurred by Cummins. Written cancellation notice is
required.

MANUALS. Unless otherwise stated, electronic submittals and electronic O & M manuals will be provided, and
print copies may be available upon Customer’s request at an additional cost.
TRAINING; START UP SERVICES; INSTALLATION. Startup services, load bank testing, and owner training are
not provided unless otherwise stated. Site startup will be subject to the account being current and will be performed
during regular Cummins business hours, Monday to Friday. Additional charges may be added for work requested to
be done outside standard business hours, on weekends, or holidays. One visit is allowed unless specified
otherwise in the Quote. A minimum of two-week prior notice is required to schedule site startups and will be subject
to prior commitments and equipment and travel availability. A signed site check sheet confirming readiness will be
required, and Cummins personnel may perform an installation audit prior to the startup being completed. Any
issues identified by the installation audit shall be corrected at the Customer's expense prior to the start-up. Portable
load banks for site test (if offered in the Quote) are equipped with only 100 feet of cable. Additional lengths may be
arranged at an extra cost. Cummins is not responsible for any labor or materials charged by others associated with
start-up and installation of Equipment, unless previously agreed upon in writing. Supply of fuel for start-up and/or
testing, fill-up of tank after start up, or change of oil is not included unless specified in the Quote. All
installation/execution work at the site including, but not limited to: civil, mechanical, electrical, supply of wall
thimbles, exhaust extension pipe, elbows, hangers, expansion joints, insulation and cladding materials,
fuel/oil/cooling system piping, air ducts, and louvers/dampers is not included unless specified in the Quote. When
an enclosure or sub-base fuel tank (or both) are supplied, the openings provided for power cable and fuel piping
entries, commonly referred to as “stub-ups”, must be sealed at the site by others before commissioning. All
applications, inspections and/or approvals by authorities are to be arranged by Customer.

WARRANTY. New and remanufactured Equipment purchased hereunder is accompanied by an express written
manufacturer’s warranty and is the only warranty offered on the Equipment. A copy of the express manufacturer’s
warranty is available upon request. Cummins’ obligations under this warranty are limited to repair or replacement,
at Cummins' option, of any defective component.

WARRANTY PROCEDURE. Prior to the expiration of the applicable warranty, Customer must give notice of a
warrantable failure to Cummins and deliver the defective Equipment to a Cummins location or other location
authorized and designated by Cummins to make the repairs during regular business hours. Cummins shall not be
liable for towing charges, maintenance items such as oil filters, belts, hoses, etc., communication expenses, meals,
lodging, and incidental expenses incurred by Customer or employees of Customer, "downtime" expenses, overtime
expenses, cargo damages and any business costs and losses of revenue resulting from a warrantable failure.

LIMITATIONS ON WARRANTIES
Cummins expressly disclaims all warranties, either express or implied, including any implied warranty of
merchantability and warranty for fitness of a particular purpose, to the extent permitted by law. The
warranties set forth herein are the sole warranties made by Cummins. Some states do not allow limitation
on warranties, so these limitations may not apply to you.
The limited warranty does not cover Equipment failures resulting from: (a) inappropriate use relative to
designated power rating; (b) inappropriate use relative to application guidelines; (c) inappropriate use of
an EPA-SE application generator set relative to EPA’s standards; (d) normal wear and tear; (e) improper
and/or unauthorized installation; (f) negligence, accidents, or misuse; (g) lack of maintenance or
unauthorized or improper repair; (h) noncompliance with any Cummins published guideline or policy; (i)
use of improper or contaminated fuels, coolants, or lubricants; (j) improper storage before and after
commissioning; (k) owner’s delay in making Equipment available after notification of potential Equipment
problem; (l) replacement parts and accessories not authorized by Cummins; (m) use of battle short mode;
(n) owner or operator abuse or neglect such as: operation without adequate coolant, fuel, or lubricants;
over fueling; over speeding; lack of maintenance to lubricating, fueling, cooling, or air intake systems; late
servicing and maintenance; improper storage, starting, warm-up, running, or shutdown practices, or for
progressive damage resulting from a defective shutdown or warning device; or (o) damage to parts,
fixtures, housings, attachments and accessory items that are not part of the generating set.

INDEMNITY. Each party shall indemnify and hold harmless the other party, its affiliates, subsidiaries, officers,
directors, agents and employees from and against any and all third party losses, costs, liabilities, damages and
expense, including reasonable attorney and expert fees (collectively, “Losses”), subject to the Limitation of
Remedies set forth below, attributable to bodily injury or property damage to the extent it is conclusively determined
that such Losses were directly caused by the gross negligence or willful misconduct of such party. The party
seeking indemnification shall give written notice to the other party promptly upon learning of the events giving rise
to such claim; provided, however, that failure to provide such notice promptly shall only relieve an indemnifying
party of its obligations hereunder to the extent it is prejudiced by such delay. The indemnifying party shall select
counsel to control and manage the defense of a claim and the settlement thereof and shall keep the indemnified
party apprised of all material developments with respect to such claim. The indemnified party may, at its expense,
select additional co-counsel. The indemnifying party shall have no obligation to indemnify or hold harmless the
indemnified party for any Losses conclusively determined to be caused by the negligence or willful misconduct of
the indemnified party.

LIMITATIONS ON REMEDIES
THE MAXIMUM LIABILITY, IF ANY, OF CUMMINS FOR ANY DAMAGES, INCLUDING WITHOUT LIMITATION,
AGREEMENT DAMAGES AND DAMAGES FOR PROPERTY, WHETHER ARISING FROM CUMMINS’ BREACH
OF AGREEMENT, BREACH OF WARRANTY, NEGLIGENCE, STRICT LIABILITY, OR OTHER TORT, IS
LIMITED TO AN AMOUNT NOT TO EXCEED THE PRICE OF THE EQUIPMENT PAID BY CUSTOMER UNDER
THIS AGREEMENT WHICH SHALL BE THE SOLE REMEDY UNDER THIS AGREEMENT. IN NO EVENT
SHALL CUMMINS BE LIABLE FOR INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE, OR CONSEQUENTIAL
DAMAGES OF ANY KIND (INCLUDING WITHOUT LIMITATION DOWNTIME, PROPERTY DAMAGE, LOSS OF
PROFIT OR REVENUE, LOSS OF DATA, DAMAGE TO GOODWILL) HOWSOEVER CAUSED ARISING FROM
THIS AGREEMENT OR THE BREACH OF THIS AGREEMENT, WHETHER IN INDEMNITY, TORT, CONTRACT,
OR OTHERWISE. NOTHING IN THIS AGREEMENT EXCLUDES OR LIMITS LIABILITY FOR DEATH OR
PERSONAL INJURY CAUSED BY CUMMINS’ GROSS NEGLIGENCE OR WILLFUL MISCONDUCT. BY
ACCEPTANCE OF THIS AGREEMENT, CUSTOMER ACKNOWLEDGES CUSTOMER’S SOLE REMEDY
AGAINST CUMMINS FOR ANY LOSS SHALL BE THE REMEDY PROVIDED UNDER THIS ENTIRE
AGREEMENT.
FORCE MAJEURE. Cummins is not responsible for the occurrence of any unforeseen event, circumstance, or
condition beyond its reasonable control including, but not limited to, acts of God, actions by any government
authority, civil strife, fires, floods, windstorms, explosions, riots, natural disasters, embargos, wars, strikes or other
labor disturbances, civil commotion, terrorism, sabotage, late delivery by Cummins' suppliers, fuel or other energy
shortages, or an inability to obtain necessary labor, materials, supplies, equipment or manufacturing facilities. If any
such cause results in delayed performance, the date of performance shall be extended for a period equal to time
lost and shall be Customer's exclusive remedy.

DEFAULT; REMEDIES. Customer shall be in breach and default if: (a) any of the payments or amounts due under
this Agreement are not paid; (b) Customer fails to comply, perform, or makes any misrepresentation relating to any
of the Customer's obligations or covenants under this Agreement; or (c) prior to full payment of the balance due,
Customer ceases to do business, becomes insolvent, makes an assignment for the benefit of its creditors, appoints
a receiver, commences an action for dissolution or liquidation, or becomes subject to bankruptcy proceedings, or
the Equipment is attached, levied upon, seized under legal process, is subjected to a lien or encumbrance, or
transferred by operation of law or otherwise to anyone other than Cummins.

Upon the occurrence of any event of Customer's default, Cummins, at its sole option and without notice, shall have
the right to exercise concurrently or separately any one or all of the following remedies, which shall be cumulative
and not alternative: (a) to declare all sums due, and to become due, under this Agreement immediately due and
payable; (b) to commence legal proceedings, including collection actions and specific performance proceedings, to
enforce performance by Customer of any and all provisions of this Agreement, and to be awarded damages or
injunctive relief for the Customer's breach; (c) to require the Customer to deliver the Equipment to Cummins'
branch specified on the face of this Agreement; (d) to exercise one or more of the rights and remedies available to
a secured party under the Uniform Commercial Code, whether or not this Agreement is subject thereto; and (e) to
enter, without notice or liability or legal process, onto any premises where the Equipment may be located, using
force permitted by law, and there to disconnect, remove and repossess the Equipment, the Customer having
waived further right to possession after default. A waiver of any event of default by Cummins shall not be a waiver
as to any other or subsequent default.

CUSTOMER REPRESENTATIONS; RELIANCE. Customer is responsible for obtaining, at its cost, permits, import
licenses, and other consents in relation to the Equipment, and if requested by Cummins, Customer shall make
these permits, licenses, and consents available to Cummins prior to shipment. Customer represents that it is
familiar with the Equipment and understands operating instructions and agrees to perform routine maintenance
services. Until the balance is paid in full, Customer shall care for the Equipment properly, maintain it in good
operating condition, repair and appearance; and Customer shall use it safely and within its rated capacity and only
for purpose it was designed. Even if Customer receives technical information, drawings, or advice, Customer has
sole responsibility for intended use, for installation and design and performance where it is part of a power,
propulsion, or other system. Limitation of warranties and remedies and all disclaimers apply to all such technical
information, drawings, or advice. Customer acknowledges and agrees by accepting delivery of the Equipment that
the Equipment purchased is of the size, design, capacity and manufacture selected by the Customer, and that
Customer has relied solely on its own judgment in selecting the Equipment.
CONFIDENTIALITY. Each party shall keep confidential any information received from the other that is not
generally known to the public and at the time of disclosure, would reasonably be understood by the receiving party
to be proprietary or confidential, whether disclosed in oral, written, visual, electronic, or other form, and which the
receiving party (or agents) learns in connection with this Agreement including, but not limited to: (a) business plans,
strategies, sales, projects and analyses; (b) financial information, pricing, and fee structures; (c) business
processes, methods, and models; (d) employee and supplier information; (e) specifications; and (f) the terms and
conditions of this Agreement. Each party shall take necessary steps to ensure compliance with this provision by its
employees and agents.

GOVERNING LAW. This Agreement and all matters arising hereunder shall be governed by and construed in
accordance with the laws of the State of Indiana without giving effect to any choice or conflict of law provision. The
parties agree that the courts of the State of Indiana shall have exclusive jurisdiction to settle any dispute or claim
arising in connection with this Agreement.

INSURANCE. During the period in which any services are to be performed, Cummins shall maintain in full force
and effect the following insurance coverages set forth below, at its sole cost and expense:

• Commercial General Liability. Commercial General Liability Insurance of not less than $2,000,000 per
occurrence and $2,000,000 annual aggregate limit.

• Automobile Liability. Business Auto Coverage with limits of $1,000,000 each accident for bodily injury and
property damage combined single limit per occurrence, extending to all owned, hired, and non-owned
vehicles.

• Worker’s Compensation. Workers’ compensation, occupational diseases, and disability benefits required
by statute.

• Employer’s Liability. Employer’s Liability with limits of at least $1,000,000 per accident per employee;
$1,000,000 per disease per employee; and $1,000,000 per disease policy limit.

• Umbrella Liability. Such insurance shall follow form on concurrent terms with and provide coverage
with limits of not less than $1,000,000 per occurrence and $2,000,000 in the aggregate.

Upon Customer’s request, Cummins will provide to Customer a Certificate of Insurance evidencing Cummins’
relevant insurance coverage.

ASSIGNMENT. This Agreement shall be binding on the parties and their successors and assigns. Customer shall
not assign this Agreement without the prior written consent of Cummins.

Intellectual Property. Any intellectual property rights created by Cummins in the course of the performance of this
Agreement or otherwise shall remain Cummins’ property. Nothing in this Agreement shall be deemed to have given
Customer a licence or any other rights to use any of the intellectual property rights of Cummins. Customer’s rights
in and to the Cummins’ intellectual property are limited to those rights as expressly set forth in this Agreement. All
rights not expressly granted to Customer under this Agreement are expressly reserved by Cummins.

MISCELLANEOUS. Cummins shall be an independent contractor under this Agreement.


All notices under this Agreement shall be in writing and be delivered personally, mailed via first class certified or
registered mail, or sent by a nationally recognized express courier service to the addresses set forth in this
Agreement.
No amendment of this Agreement shall be valid unless it is writing and signed by the parties hereto. Failure of
either party to require performance by the other party of any provision hereof shall in no way affect the right to
require such performance at any time thereafter, nor shall the waiver by a party of a breach of any of the provisions
hereof constitute a waiver of any succeeding breach.

Any provision of this Agreement that is invalid or unenforceable shall not affect the validity or enforceability of the
remaining terms hereof.

These terms are exclusive and constitute entire agreement. Customer acknowledges that the provisions were
freely negotiated and bargained for and Customer has agreed to purchase of the Equipment pursuant to these
terms and conditions. Acceptance of this Agreement is expressly conditioned on Customer's assent to all such
terms and conditions. Neither party has relied on any statement, representation, agreement, understanding, or
promise made by the other except as expressly set out in this Agreement. In the event of a conflict in the terms of
this Agreement with any Customer terms or conditions or agreement (whether referenced in an order submitted by
Customer as the terms that govern the purchase of the Equipment or otherwise) or any terms set forth in any other
documentation of Customer with respect to the Equipment, the terms of this Agreement shall govern.

MISCELLANEOUS CHARGES. Cummins may incur additional charges which will be passed on to the Customer, as
applicable.
COMPLIANCE. Customer acknowledges that the Equipment, and any related technology that are sold or otherwise
provided hereunder may be subject to export and other trade controls restricting the sale, export, re-export and/or
transfer, directly or indirectly, of such Equipment or technology to certain countries or parties, including, but not
limited to, licensing requirements under applicable laws and regulations of the United States, the United Kingdom
and other jurisdictions. It is the intention of Cummins to comply with these laws, rules, and regulations. Any other
provision of this Agreement to the contrary notwithstanding, Customer shall comply with all such applicable all laws
relating to the cross-border movement of goods or technology, and all related orders in effect from time to time,
and equivalent measures. Customer shall act as the importer of record with respect to the Equipment and shall not
resell, export, re-export, distribute, transfer, or dispose of the Equipment or related technology, directly or indirectly,
without first obtaining all necessary written permits, consents, and authorizations and completing such formalities
as may be required under such laws, rules, and regulations. In addition, Cummins has in place policies not to
distribute its products for use in certain countries based on applicable laws and regulations including but not limited
to UN, U.S., UK, and European Union regulations. Customer undertakes to perform its obligations under this
Agreement with due regard to these policies. Strict compliance with this provision and all laws of the territory
pertaining to the importation, distribution, sales, promotion and marketing of the Equipment is a material
consideration for Cummins entering into this Agreement with Customer and continuing this Agreement for its term.
Customer represents and warrants that it has not and shall not, directly or through any intermediary, pay, give,
promise to give or offer to give anything of value to a government official or representative, a political party official,
a candidate for political office, an officer or employee of a public international organization or any other person,
individual or entity at the suggestion, request or direction or for the benefit of any of the above-described persons
and entities for the purposes of inducing such person to use his influence to assist Cummins in obtaining or
retaining business or to benefit Cummins or any other person in any way, and will not otherwise breach any
applicable laws relating to anti-bribery. Any failure by Customer to comply with these provisions will constitute a
default giving Cummins the right to immediate termination of this Agreement and/or the right to elect not to
recognize the warranties associated with the Equipment. Customer shall accept full responsibility for any and all
civil or criminal liabilities and costs arising from any breaches of those laws and regulations and will defend,
indemnify, and hold Cummins harmless from and against any and all fines, penalties, claim, damages, liabilities,
judgments, costs, fees, and expenses incurred by Cummins or its affiliates as a result of Customer’s breach.

Version 8/2017
Cummins Sales and Service Generator Sets
Limited Warranty

Commercial Generating Set


This limited warranty applies to all Cummins Sales and Service branded commercial generating sets and associated
accessories (hereinafter referred to as "Product"). This warranty covers any failures of the Product, under normal use and
service, which result from a defect in material or factory workmanship.

Warranty Period:
The warranty start date for stationary Product is the date of initial startup, demonstration or 18 months after factory ship
date, whichever is sooner. The warranty start date for rental or oil and gas products is the date of receipt of Product by
the end customer. See tables for details.

Emergency Standby Power (ESP) is defined as the maximum power available during a variable electrical power
sequence, under the stated operational conditions, for which generating set is capable of delivering in the event of a
reliable utility power outage. The permissible average power output over 24 hours of operation shall not exceed 70%
of the ESP. For applications supporting an unreliable utility service, the Prime Power (PRP) rating should be used.

Prime Power (PRP) is defined as being the maximum power which a generating set is capable of delivering
continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year. The
permissible average power output over 24 hours of operation shall not exceed 70% of the PRP. For applications
requiring permissible average output higher than stated, a COP rating should be used. Total operating time at 100%
PRP rating shall not exceed 500 hours/year.

Demand Response Power Rating - Spark-Ignited Gas (DRP) is applicable for supplying electrical power in parallel with
commercially available power in variable and non-variable loadapplications. This fuel rating is intended for use in
situations where power outages are contracted, such as in utility power curtailment. Engine operations is limited to a
total of 500 hours per year. Engines may be operated in parallel to the public utility up to 500 hours per year. Engines
may be operated in rated Demand Response Power. Engines with Standby Power ratings available can be run in
Emergency Standby applications up to the Standby Power rating for up to 50 hours per year. The customer should be
aware, however, that the life of any engine will be reduced by constant high load operation.

Continuous Power (COP) is defined as being able to supply utility power at a constant 100 percent load for an unlimited
number of hours per year. No overload capability is available for this rating. Reference Cummins Bulletin # 3381307.

Base Warranty Duration


(Whichever occurs first)
Rating Months Maximum Hours
Emergency Standby Power (ESP) 24 400
Prime Power (PRP) 12 Unlimited
Demand Response Power (DRP) 12 500*
Continuous Power (COP) 12 Unlimited
Commercial Mobile (Kubota) 12 200
*Of which 50 hours -- maximum -- can be run at the Standby rating. If applicable.
Cummins Sales and Service Responsibilities:
In the event of a failure of the Product during the warranty period due to defects in material or workmanship, Cummins
Sales and Service will only be responsible for the following costs:
 All parts and labor required to repair the Product.
 Reasonable travel expenses to and from the Product site location.
 Maintenance items that are contaminated or damaged by a warrantable failure.

Owner Resposibilities:
The owner will be responsible for the following:
 Notifying the Cummins Sales and Service distributor or dealer within 30 days of the discovery of
failure.
 Installing, operating, commissioning and maintaining the Product in accordance with Cummins
Sales and Service’s published policies and guidelines.
 Providing evidence for date of commissioning.
 Providing sufficient access to and reasonable ability to remove the Product from the installation
in the event of a warrantable failure.
In addition, the owner will be responsible for:
 Incremental costs and expenses associated with Product removal and reinstallation resulting
from difficult or non-standard installations.
 Costs associated with rental of generating sets used to replace the Product being repaired.
 Costs associated with labor overtime and premium shipping requested by the owner.
 All downtime expenses, fines, all applicable taxes, and other losses resulting from a warrantable
failure.

Limitations:
This limited warranty does not cover Product failures resulting from:
 Inappropriate use relative to designated power rating or application guidelines.
 Normal wear and tear, negligence, accidents or misuse.
 Improper and/or unauthorized installation.
 Lack of maintenance or unauthorized repair.
 Noncompliance with any Cummins Sales and Service published guideline or policy.
 Use of improper or contaminated fuels, coolants or lubricants.
 Improper storage before and after commissioning.
 Owner’s delay in making Product available after notification of potential Product problem.
 Replacement parts and accessories not authorized by Cummins Sales and Service.
 Use of Battle Short Mode.
 Owner or operator abuse or neglect such as: operation without adequate coolant or lubricants;
over-fueling; over-speeding; lack of maintenance to lubricating, cooling or air intake systems;
late servicing and maintenance; improper storage, starting, warm-up, run-in or shutdown
practices, or for progressive damage resulting from a defective shutdown or warning device.
 Damage to parts, fixtures, housings, attachments and accessory items that are not part of the
generating set.
 Accelerated corrosion damage from debris and road de-icing material while being transported.
This Limited Warranty does not apply to:
 Costs of maintenance, adjustments, installation, commissioning or start-up.
 Starting batteries, battery chargers, cooling packages, heating elements, trailers, and enclosures.
(These components shall be covered by the respective manufacturer’s warranty.)
 Components added to the Product after shipment from Cummins Sales and Service.

Please contact your local Cummins Sales and Service Distributor for clarification concerning these limitations.
Extended Warranty

Extended Coverage may be purchased to include parts and labor for a two-year, 400 hour period.
NOTE: Coverage does not include travel expenses.

OR

Extended Coverage may be purchased to include parts and labor for the engine and generator for a five-
year, 1500 hour period. The extended engine warranty is outlined as described in Cummins Bulletin
#3624423 for the Cummins ENCOMPASS Extended Coverage program.

Warranty Options*
(Whichever occurs first)
Rating Months Maximum Hours
Emergency Standby Power (ESP) -
60 1500
Five-year ENCOMPASS Extension
*Does not apply to LTP or Commercial Mobile (Kubota) GenSets

NOTES:
 For Base Engine Warranty Only, reference Cummins Bulletin # 3381307.
 The A/C Generator (Alternator) carries a two-year / 1000 hours warranty, limited to 500 hours per
year for two years, whichever is shorter for Emergency or Standby use.

Cummins Sales and Service Right to Failed Components:


Failed components claimed under warranty remain the property of Cummins Sales and Service. Cummins
Sales and Service has the right to reclaim any failed component that has been replaced under warranty.

THE WARRANTIES SET FORTH HEREIN ARE THE SOLE WARRANTIES MADE BY
CUMMINS SALES AND SERVICE IN REGARD TO THE PRODUCT. CUMMINS SALES AND
SERVICE MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, OR OF
OR OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT
IS CUMMINS SALES AND SERVICE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES.

This limited warranty shall be enforced to the maximum extent permitted by applicable law. This
limited warranty gives the owner specific rights that may vary from state to state or from jurisdiction
to jurisdiction.

This product has been manufactured under the controls established by a Bureau Veritas Certification
approved management system that conforms with ISO 9001:2015.

You might also like