You are on page 1of 1

17.

04

w w w w
3.32

CLASS ROOM CLASS ROOM 3.70

NO-1 NO-2 v v

1.5m x 2.20m
6.40m x 5.50m 6.40m x 5.50m 1.08 0.88

w/c
girls toilet
8.36
D
D
w/c
2.20m x 1.5m
v 5.88

boys toilet
D1 D1 D1 D1
w1 w1 0.75
D
D2

0.75
v
2.4m wide corridor 2.4m wide corridor
1.58 v
D

0.93

D1
4.00

2.4m wide corridor

6.40m x 5.50m
NO-3
CLASS ROOM
w

w1

13.49 13.49

schedule of opening D1

2.4m wide corridor

6.40m x 5.50m
NO-4
CLASS ROOM
DOOR (D) 600 MM X 2100MM w
DOOR (D1) 1200 MM X 2100MM

WINDOW (W) 1800 MM X 1200MM

WINDOW (W1) 1200 MM X 1200MM

VENTILATION (V) 600 MM X 600 MM w1

GROUND FLOOR D1

5.96
8.36

GENERAL NOTES AND SPECIFICATIONS


TITLE OF SHEET :- PROJECT NAME :-
8.LAPPING STEEL FOR BEAMS SHOULD NOT BE GIVEN AT THE GOVERNMENT OF KARNATAKA
1. ALL DIMENSIONS ARE IN M. MIDDLE OF THE SPAN FOR BOTTOM STEEL & SHOULD & SCALE:- N.T.S DATE:
2. DO NOT SCALE THE DRAWING, REFER FIGURED SHOULD NOT BE GIVEN AT THE SUPPORTS FOR TOP STEEL.
PRIMARY SCHOOL BUILDING FOR PUBLIC WORKS, PORT & INLAND TRANSPORT
KARNATAKA PUBLIC SCHOOL AT
DIMENSION.
3. ANY DESCRIPANCIES OR OMISSION OR CHANGES
SHALL BE BROUGHT TO NOTICE PRIOR TO EXECUTION.
9. CLEAR COVER TO RENFORCEMENT
a) FOOTING = 50 MM
c) BEAM = 25 MM
b) COLUMN = 40 MM
d) SLAB = 15 MM
PLAN KATKOL VILLAGE IN RAMDURG TQ
Struc.Drg No:- PWD/BLD/
C & B(NORTH) , DHARWAD

4. ALL CONCRETE SHALL HAVE CRUSHING STRENGTH AS SPECIFIED 10. REINFORCING BARS SHALL BE FREE OF RUST ,GREASE OR OTHER
BY GRADE/ CORRESPONDING MIX MENTIONED ELSE WHERE MATERIALS LIKELY TO IMPAIR BOND.
THE DRAWING. 11. GENERAL NOTES & TYPICAL DETAILS APPLY TO ALL DRAWINGS
5. # DENOTES TWISTED FOR STEEL BARS. ALL STEEL BARS UNLESS OTHERWISE SHOWN OR MENTIONED. CIVIL CONSULTANT:-
CONFORM TO I.S.I. STANDARDS YIELD STRENGTH.
6. SPACER BARS & CHAIRS MAY BE PROVIDED WHEREVER 12. THE BUILDING DESIGNED FOR GROUND + 1 + 1 EXTRA FLOORS SAI INFRASTRUCTURES
REQURIED, i.e., FOOTING,BEAMS, SLAB, ETC., TO SUIT 13. LAST SLAB IS DESIGNED FOR ROOFLOADING ONLY.
SITE CONDITIONS 14. CONCRETE GRADE USED IS M25 UNLESSOTHERWISE MENTIONED.
Er. NIKHIL S. MALADKAR
CIVIL ENGG
7. LAPPING OR ANCHORAGE LENGTH ALL STEEL EXCEPT 6mmØ IS TOR STEEL( # ) OF GRADE Fe 500 N/mmSq.
FOR a) BEAM AND SLAB = 60 TIMES DIA 15. ALL STEEL EXCEPT 6mmØ IS TOR STEEL( # ) OF RAMDURG
b) COLUMN = 50 TIMES DIA 16. S.B.C OF SOIL 13 T/m^2
CELL. NO. +91-6364114221
17. DO NOT CAST ANY R.C.C WORK UNLESS IT IS CHECKED & CONFIRMED BY
+91-8217306042
ENGINEER

E-mail :-Infrastructuressai@gmail.com