COMBINE

C/C
0.5 3
Distance 0.5

C1 C2

L= 4

Total Load 420 KN


=
Self Wt. Of
42 KN
Foundation =
Total Load On
= 462 KN
Footing
Area Of Footing
3.08 M2
Required =
Adopted Footing
= 6.00 M2 OK
Size
Upward Soil
= 77.00 KN/M2
Pressure
Factored Soil
115.50 KN/M2
Pressure =
Upward Soil
Pressure Per Unit 173.25 KN/M
Length =
Distance Of C.G.
1.5 M
From Column 1 =
Distance Of C.G.
1.5 M
From Column 2 =
B.M. At C1 = 21.66 KNM
B.M. At C2 = 21.66 KNM

B.M. At Mid Point 31.50 KNM


=
S.F. At C1 L = 86.63 KN
S.F. At C1 R = -123.38 KN
S.F. At C2 L = 86.63 KN
S.F. At C2 R = -123.38 KN
Effective Depth = 72.55 MM
Total Depth = 132.55 MM
One Way Shear Depth = 210.00 MM
Total One Way
270.00 MM
Shear Depth =
Total Depth
= 600.00 MM
Provided
Area Resisting
Punching Shear = 2880000.00 MM2
S.F. At Critical Section = 924.00 KN
ꚍv for two way shear = 0.32 N/MM2 OK
ꚍc = 1.37 N/MM2
Ast = 121.16 MM2
No. Of Bars = 0.60 Nos
Min Steel Prov. = 0.12%
FAIL
Percentage Of Steel PROVIDE
= 0.01%
Provided MIN.
STEEL
Spacing = 1659.72 mm
No. Of Bars Provided = 6.00 Nos
COMBINED FOOTING

Size Of Column = 600.00 MM


Load On Column 1 = 210.00 KN
Load On Column 2 = 210.00 KN
Soil Bearing Capacity = 150.00 KN/M2
B= Fe = 500.00 N/MM2
1.50 Fck = 30.00 N/MM2
Bar Diameter = 16.00 MM

No. Of Footing
Bar Dia C/s Of Bar Spacing
Total Depth Bars Diamensions
201.088
600 mm 16 mm mm2 6.00 4000X1500 mm 300.00

100As/bd M15 M20 M25 M30 M35

0.15 0.28 0.28 0.29 0.29 0.29


0.25 0.3S 0.36 0.36 0.37 0.37
0.5 0.46 0.48 0.49 0.5 0.5
0.75 0.54 0.56 0.57 0.59 0.59
1 0.60 0.62 0.64 0.66 0.67
1.25 0.64 0.67 0.70 0.71 0.73
1.5 0.68 0.72 0.74 0.76 0.78

1.75 0.71 0.75 0.78 0.80 0.82


2.00 0.71 0.79 0.82 0.84 0.86

2.25 0.71 0.81 0.85 0.88 0.90


2.5 0.71 0.82 0.88 0.91 0.93
2.75 0.71 0.82 0.90 0.94 0.96
3 0.71 0.82 0.92 0.96 0.99

2.5 0.91

2.75 0.94

Area = 2.66 0.93


ꚍc = 0.93
M 40 and
above
(7)
0.30
0.38
0.51
0.60
0.68
0.74
0.79

0.84
0.88

0.92
0.95
0.98
1.01