Instruction manual and parts list

for compressed air filters


DDx - DDxp - PDx - PDxp - QDx

Instruction manual .................................................................................................. 3


Bedieningshandleiding ........................................................................................... 9
Manuel d’instructions............................................................................................ 15
Bedienungsanleitung............................................................................................ 21
Libro de Instrucciones .......................................................................................... 27
Instruktionsbok ..................................................................................................... 33
Manuale di istruzioni............................................................................................. 39
Instruksjonsmanual .............................................................................................. 45
Instruktionsbog ..................................................................................................... 51
ΕΓΧΕΙΡΙ∆ΙΟ ΧΡΗΣΗΣ .......................................................................................... 57
Manual de instruções ........................................................................................... 63
Ohjekirja ............................................................................................................... 69

Spare parts catalogue........................................................................................... 75


Onderdelenlijst – Liste de pièces – Ersatzteilliste – Lista de las partes –
Reservdelsförteckning – Listino parti di ricambio – Deleliste –
REGISTRATION CODE
Reservedelsliste – Kατάλoγoς Eξαρτηµάτων – Lista de peças – Osaluettelo
Collecton:
Ancillaries
Tab:
38
Sequence:
-

Printed Matter Number


2904 0183 00
ATLAS COPCO - INDUSTRIAL AIR DIVISION
2004-05 P.O. Box 103, B-2610 WILRIJK - BELGIUM
INSTRUCTION MANUAL

INSTRUCTION MANUAL

Congratulations on the purchase of your Atlas Copco filter. It is a solid, safe and reliable unit, built according to the latest technology.
Follow the instructions in this booklet and we guarantee you years of troublefree operation.

While every effort has been made to ensure that the information in this manual is correct, Atlas Copco does not assume responsibility for
possible errors. Atlas Copco reserves the right to make changes without prior notice.

1. TABLE OF CONTENTS

1. TABLE OF CONTENTS .......................................................................................................................................................................................3

2. DESCRIPTION ....................................................................................................................................................................................................4
2.1 DDx filters ...................................................................................................................................................................................................4
2.2 DDxp and PDxp filter ..................................................................................................................................................................................4
2.3 PDx filter .....................................................................................................................................................................................................4
2.4 QDx filter.....................................................................................................................................................................................................4
2.5 Difference between DDx/PDx and DDxp/PDxp ..........................................................................................................................................4

3. INSTALLATION ...................................................................................................................................................................................................4
3.1 General remarks .........................................................................................................................................................................................4
3.2 Specific remarks .........................................................................................................................................................................................4
3.3 Options .......................................................................................................................................................................................................5
3.4 ISO 8573-1 norm ........................................................................................................................................................................................5

4. MAINTENANCE ..................................................................................................................................................................................................6

5. FILTER ELEMENT CHANGE ..............................................................................................................................................................................6


5.1 Procedure ...................................................................................................................................................................................................6
5.2 Service intervals .........................................................................................................................................................................................6

6. TECHNICAL SPECIFICATIONS..........................................................................................................................................................................7
6.1 Reference conditions ..................................................................................................................................................................................7
6.2 Principle data ..............................................................................................................................................................................................7
6.3 Specific data ...............................................................................................................................................................................................7
6.4 Nominal capacity ........................................................................................................................................................................................7
6.5 Correction factors and usage......................................................................................................................................................................7
6.6 Dimensions and weight...............................................................................................................................................................................8
6.7 Supplied components .................................................................................................................................................................................8

7. CONTENTS OF THE SPARE PARTS CATALOGUE..........................................................................................................................................8

8. ORDERING SPARE PARTS ...............................................................................................................................................................................8

9. CONVERSION TABLE ......................................................................................................................................................................................83

10. NOTES ..............................................................................................................................................................................................................83

This instruction book meets the requirements for instructions specified by the machinery directive 89/392/EEC and is valid for CE as well
as non-CE labelled machines.

2904 0183 00 3
DDX - DDXP - PDX - PDXP - QDX

2. DESCRIPTION 3. INSTALLATION

2.1 DDx filters 3.1 General remarks


The DDx filter is a general purpose protection and liquid When installing the filter, keep in mind the following:
removal filter. The filter element retains water and oil particles, – Be sure that the pipework is internally clean, especially
which can be removed by the drain. downstream of the filter.
The air flow is from inside to outside the filter element. – The filters must be mounted vertically.
– If the unit is integrated in a multiple line system, provide
2.2 DDxp and PDxp filter isolating valves and, if required, a by-pass.
The DDxp and PDxp filters are dust filters. The filter element – The automatic drain has a special connection allowing easy
traps the solid particles. The PDxp filter is the same as the DDxp installation of a flexible or a quick coupling to pipe away the
filter but is more efficient. drained liquid. Take care not to create a flow resistance.

The air flow is from outside to inside the filter element.


3.2 Specific remarks
2.3 PDx filter
3.2.1 DDx filter
The PDx filter is the same as the DDx filter but is more efficient. It
is a high efficiency dust, liquid and aerosol removal filter for No specific remarks for the installation of the DDx filter.
compressed air. The filter element traps the solid particles. The
oil/water aerosols liquefy and the so-formed drops collect and are 3.2.2 DDxp and PDxp filter
removed by the drain.
When the DDxp and PDxp filters are used with an adsorption type
The air flow is from inside to outside the filter element. air dryer, install the filter downstream of the dryer.

2.4 QDx filter 3.2.3 PDx filter

The QDx filter is an oil vapour and odour removal filter. The air The filter must be mounted as close as possible to the point of use
flows through the activated carbon which is contained in the QDx of the air.
filter element and which absorbs oil vapours and odours.
It is recommended to install a DDx filter upstream the PDx filter. If
not, the load on the PDx filter element may become too high and
This filter does not remove methane, carbone will reduce its lifetime.
monoxide, carbon dioxide or other toxic gases and
fumes.
3.2.4 QDx filter

To protect the active carbon element, the QDx filter must always
2.5 Difference between DDx/PDx and DDxp/PDxp be preceded by a PDx filter.
The difference between the DDx/PDx and the DDxp/PDxp filters The filter should be mounted as close as possible to the point of
is the air flow. use of the air.
In case of DDx or PDx filters, the air flows from inside the filter
element to outside the filter element.

In case of DDxp or PDxp filters, the air flows from outside the filter
element to inside the filter element.

4 2904 0183 00
INSTRUCTION MANUAL

3.3 Options 3.4 ISO 8573-1 norm


– If two or more filters are used in combination, build the filter For new installations as well as for installations that have to be
heads together by means of a serial connection in the correct made up-to-date, the ISO 8573-1 norm can be used. This norm
air flow direction and DDx upstream of PDx. An arrow for the describes several quality classes and, depending on these
air flow direction is provided on the filter head.
classes and applications, some proposals are given fulfilling this
– For wall mounting, a special set is available as option. Fit the norm.
mounting bracets with bolts, washers and nuts to a solid
frame within easy reach, leaving sufficient space underneath
The ISO 8573-1 norm only concerns “Compressed
for maintenance and service.
air for general” use and does not deal with, or is not
– Quick couplings are available to make an easy connection of applicable to, e.g. breathing air.
the automatic drain valve possible.
– All DDx, DDxp, PDx and PDxp filters can be provided with a
differential pressure indicator, a differential pressure gauge or Quality D W O
class (Dirt) (Water) (Oil)
a voltage free contact switch.
Maximum number of particles per m³
– See the spare parts lists for the correct numbers of the sales (d = particle size in µ m) Max. Max. con-
kits. pressure centration
0.10 < 0.5 < 1,0 < dewpoint (mg/m³)
d ≤ 0.10 d d d (°C)
3.3.1 Dual Pressure Transmitter ≤ 0.5 ≤ 1.0 ≤ 5,0

0 As specified by the equipment user or supplier and more stringent than class 1.
Option on the DDx, DDxp, PDx and PDxp filters (refer to figure 4).
1 – 100 1 0 -70 0.01
The dual pressure transmitter of Atlas Copco is designed to moni-
2 – 100,000 1,000 10 -40 0.1
tor gauge pressure and differential pressure over a DDx, DDxp,
PDx or PDxp filter. For each channel, pressure and pressure drop, 3 Not
– 10,000 500 -20 1.0
specified
a 4 to 20 mA signal is provided.
4 Not Not
– 1,000 +3 5.0
The dual pressure transmitter is mounted between the filter head specified specified
and the differential pressure gauge. It needs a 12 to 24 VDC input 5 –
Not Not
20,000 +7 –
specified specified
voltage and generates 2 signals: one signal proportional with the
pressure drop over the filter and one signal proportional with the 6 – Not applicable +10 –
gauge input pressure. These 4 to 20 mA signals can be used as
input on the Compressor Room Control (CRC box) or on a com-
The air quality to ISO 8573-1 is expressed as follows: class X.Y.Z,
puter with an analogue input converter (to RS232 or RS485 proto-
where X, Y and Z are respectively the quality classes with regard
col) to monitor and log the behaviour of the filter.
to dirt, water and oil.

3.3.2 Electronic Drain EWD 50L A few examples are given in Fig. 1:
A ......... General purpose protection
Option on the DDx and PDx filters (refer to figure 5).
(air quality to ISO 8573-1: class 2.-.2)
The electronic drain EWD 50L is a zero-loss, electronically opera- B ......... High-quality air with reduced dewpoint
ted drain valve, specially designed to drain oil condensate. A sen- (air quality to ISO 8573-1: class 1.4.1)
sor senses the condensate level. If this level exceeds a preset C......... General purpose protection and reduced oil concentration
value, the drain waits for a fixed-programmed time, then a sole- (air quality to ISO 8573-1: class 1.-.1)
noid valve is activated and the condensate is discharged. When D......... High quality air with extremely low dewpoint
all the condensate is discharged, the solenoid valve closes and (air quality to ISO 8573-1: class 1.2.1)
condensate is collected again. This way, the loss of air is reduced
The components shown in Fig. 1 are:
to a minimum.
1 .... Compressor with aftercooler
If the microcontroller registers a malfunction, the automatic drain
2 .... DDx filter
valve will automatically change to alarm mode. This alarm signal
can be relayed via a potential-free contact. 3 .... PDx filter
4 .... QDx filter (for critical applications)
The EWD 50L has three operating voltages: 220V, 115V and 24V.
5 .... DDxp or PDxp filter
An extra electric wiring can be foreseen to connect the potential
free contacts and an external test button. 6 .... FD refrigerant dryer
7 .... CD desiccant dryer
Remove the manual or automatic drain of the filter before instal-
ling the EWD 50L. 8 .... Compressor with integrated dryer

2904 0183 00 5
DDX - DDXP - PDX - PDXP - QDX

4. MAINTENANCE 5. FILTER ELEMENT CHANGE


When maintaining the filter, keep in mind the following:
5.1 Procedure
– On filters with manual drain valve, open the latter at regular
intervals to evacuate collected dust or liquid.
A small amount of acid-free vaseline may be applied
– For DDx, DDxp, PDx and PDxp filters, change the filter to screw threads and O-rings to facilitate the
element yearly or when the pressure drop reaches approx. assembly.
0.45 bar.
– In case an automatic drain valve is installed, manual draining
can be carried out by turning the connection nipple of the Refer to Fig. 2. The on the figure indicates the items provided
automatic drain valve counterclockwise. Open at regular in a new filter kit.
intervals to check if the drain valve still works properly.
1. Isolate the filter from the air net.
– For QDx filters, the change interval of the adsorption element
is approx. 750 operating hours or yearly. Its pressure drop will 2. Depressurize the filter by turning the connection nipple of the
not increase during its useful life. Nevertheless, the automatic drain valve counterclockwise or by opening the
adsorption element must be changed earlier at the first signs manual drain valve.
of oil vapour and odour.
3. Unscrew the bowl. A whistling noise will warn you if the bowl
is not fully depressurized. If this occurs, the bowl should be
When the filter has to process air with a temperature
screwed back and the venting should be repeated.
higher than the maximum temperature, the filter’s
lifetime will reduce considerably. 4. Discard the filter element.
5. Remove the drain valve by unscrewing the retaining nut
underneath the bowl.
6. Remove the O-ring from the bowl and clean the bowl.
Position a new O-ring on the bowl.
7. Remove the O-ring from the drain valve and position a new
O-ring on the drain valve. The latter is supplied with each
new filter kit.
8. Reinstall the drain valve in the bowl using the retaining nut.
9. Reposition the new filter element with the 2 new O-rings.
10. Screw the bowl completely on the head.

5.2 Service intervals


The following service intervals should be observed:
– For units operating less than 4.000 hours per year: 12
months.
– For units operating 8.000 hours per year: 12 months.

6 2904 0183 00
INSTRUCTION MANUAL

6. TECHNICAL SPECIFICATIONS

6.1 Reference conditions 6.3 Specific data


Air inlet pressure ...................................................................................... 7 bar(e)
6.3.1 DDxp filter
Air inlet temperature.......................................................................... 20 °C (68 F)
Filter efficiency down to 0,3 µ m .................................................................99,9 %
Ambient temperature......................................................................... 20 °C (68 F)

6.3.2 DDx filter


6.2 Principle data
Maximum oil carry over at 20°C (68 F) and 7 bar(e)............................. 0.1 mg/m³
Maximum compressed air inlet pressure .....................................16 bar (232 psi)
Filter efficiency down to 0,3 µ m .................................................................99.9 %
Minimum compressed air inlet pressure ..........................................1 bar (15 psi)
Minimum compressed air inlet temperature ........................................ 1 °C (34 F) 6.3.3 PDx filter

Maximum compressed air inlet temperature ..................... 65 °C (35 °C for QDx) Maximum oil carry over at 20°C (68 F) and 7 bar(e)........................... 0.01 mg/m³

Minimum ambient temperature ........................................................... 1 °C (34 F) Filter efficiency down to 0,3 µ m .............................................................99.999 %

Maximum ambient temperature ........................................ 65 °C (35 °C for QDx)


6.3.4 QDx filter
Maximum recommended pressure drop ....................................... 0.45 bar (5 psi)
(not for QDx) Maximum compressed air inlet temperature ..................................... 35 °C (95 F)
for normal service life
Maximum oil carry over at 20°C (68 F) and 7 bar(e)......................... 0.003 mg/m³

6.3.5 PDxp filter


Filter efficiency down to 0,3 µ m .............................................................99.999 %

6.4 Nominal capacity

Type 11 21 40 55 75 145 190 220 325 480 650

l/s 11 21 40 55 75 145 190 220 325 480 650

cfm 23 44 84 116 158 306 401 464 686 1013 1372

6.5 Correction factors and usage

When the actual working pressure differs from the reference pressure, multiply the nominal capacity of the filter with the
corresponding correction factor to obtain the correct capacity.

Working pressure 1 bar 2 bar 3 bar 4 bar 5 bar 6 bar 7 bar 8 bar 10 bar 12 bar 14 bar 16 bar

Correction factor 0,38 0,53 0,65 0,75 0,83 0,92 1 1,06 1,20 1,31 1,41 1,50

2904 0183 00 7
DDX - DDXP - PDX - PDXP - QDX

6.6 Dimensions and weight


Refer to Fig. 3.

Type A B C D E F G H J K L M N P Q R Net
(“) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) mass
11 1/2 158 136 90 8 303 228 21 7 20 92 80 2 52 60 6.6 1 kg
21 1/2 158 136 90 8 303 228 21 7 20 92 80 2 52 60 6.6 1.1 kg
40 1/2 158 136 90 8 358 283 21 7 20 92 80 2 52 60 6.6 1.3 kg
55 3/4 190 168 110 5 378 303 27.5 10 30 118 100 2 68 72 9 1.9 kg
75 1 190 168 110 5 418 343 27.5 10 30 118 100 2 68 72 9 2.1 kg
145 1 1/2 240 218 140 5 549 449 34 10 42 157.5 131 2.5 92 103 9 4.2 kg
190 1 1/2 240 218 140 5 632 532 34 10 42 157.5 131 2.5 92 103 9 4.5 kg
220 1 1/2 240 218 140 5 632 532 34 10 42 157.5 131 2.5 92 103 9 4.6 kg
325 2 1/2 279 251 179 8 768 618 50 12 42 183 166 2.5 100 135 11 6.9 kg
480 3 320 288 210 9 920 720 57 15 50 230.5 191 4 135 155 11 11 kg
650 3 320 288 210 9 1090 890 57 15 50 230.5 191 4 135 155 11 12.6 kg

Dimension A is G or NPT.

Dimension F indicates the space needed for dismantling.

6.7 Supplied components


The list below gives an overview of the components provided on the different types of filters:
DDx..... Supplied with automatic drain
DDxp... Supplied with manual drain
PDx ..... Supplied with automatic drain
PDxp ... Supplied with manual drain
QDx..... Supplied with manual drain

7. CONTENTS OF THE SPARE PARTS CATALOGUE

DDX - DDXP - PDX - PDXP - QDX : 11 - 21 - 40 ..............................................................................................................................................75

DDX - DDXP - PDX - PDXP - QDX : 55 - 75.....................................................................................................................................................76

DDX - DDXP - PDX - PDXP - QDX : 145 - 190 - 220........................................................................................................................................77

DDX - DDXP - PDX - PDXP - QDX : 325 ..........................................................................................................................................................78

DDX - DDXP - PDX - PDXP - QDX : 480 - 650................................................................................................................................................. 79

8. ORDERING SPARE PARTS

To order spare parts, see the instructions on the front and rear cover of this manual.

8 2904 0183 00
DDX - DDXP - PDX - PDXP - QDX : 11 - 21 - 40

11 1a

22
25
8 6 24
9
10 20 4
6
28
21
1

5
12

2
27

26

DDx - DDxp - PDx - PDxp - QDx : 11 DDx - DDxp - PDx - PDxp - QDx : 21 DDx - DDxp - PDx - PDxp - QDx : 40
Ref. Part Number Note Qty Ref. Part Number Note Qty Ref. Part Number Note Qty Designation
– 8102 2651 40 – 8102 2651 99 – 8102 2652 49 DDx filter complete
– 8102 2651 57 – 8102 2652 07 – 8102 2652 56 DDxp filter complete
– 8102 2649 78 – 8102 2651 65 – 8102 2652 15 PDx filter complete
– 8102 2649 86 – 8102 2651 73 – 8102 2652 23 PDxp filter complete
– 8102 2649 94 – 8102 2651 81 – 8102 2652 31 QDx filter complete
– 2901 1205 00 – 2901 1208 00 – 2901 1211 00 DDx and DDxp element kit
– 2901 0867 00 – 2901 1206 00 – 2901 0864 00 PDx and PDxp element kit
– 2901 1204 00 – 2901 1207 00 – 2901 1210 00 QDx element kit
1 – 1 1 – 1 1 – 1 Head
1a • 0196 1552 88 2 1a • 0196 1552 88 2 1a • 0196 1552 88 2
2 – 1 2 – 1 2 – 1 Bowl
3 – 1 1 3 – 1 1 3 – 1 1 Filter element
4 0663 9868 00 1 1 4 0663 9868 00 1 1 4 0663 9868 00 1 1 O-ring, 57,2x3
5 0663 2101 80 1 2 5 0663 2101 80 1 2 5 0663 2101 80 1 2 O-ring for filter, 20x2
6 0663 2111 29 1 1 6 0663 2111 29 1 1 6 0663 2111 29 1 1 O-ring, 18x3,5
7 1617 7046 00 1 7 1617 7046 00 1 7 1617 7046 00 1 Nut, G3/8”
8 8055 2600 72 2/3 1 8 8055 2600 72 2/3 1 8 8055 2600 72 2/3 1 Differential press. indicator
9 8055 2600 80 2/3 1 9 8055 2600 80 2/3 1 9 8055 2600 80 2/3 1 Differential press. gauge
10 – 1 10 – 1 10 – 1 Identification label
11a 8055 2600 98 2/3 1 11a 8055 2600 98 2/3 1 11a 8055 2600 98 2/3 1 Potential free contact
Normally open
11b 8055 2601 06 2/3 1 11b 8055 2601 06 2/3 1 11b 8055 2601 06 2/3 2 Potential free contact
Normally closed
12 0690 1104 01 2 12 0690 1104 01 2 12 0690 1104 01 2 Atlas Copco decal
20 8092 2429 68 2 20 8092 2429 68 2 20 8092 2429 68 2 Wall mounting kit
21 8092 2430 16 2 21 8092 2430 16 2 21 8092 2430 16 2 Serial connection kit
22 • 0663 2100 24 1 22 • 0663 2100 24 1 22 • 0663 2100 24 1 O-ring, 26x2
24 2901 0563 00 4 24 2901 0563 00 4 24 2901 0563 00 4 Automatic drain valve kit
25 2901 0611 00 5 25 2901 0611 00 5 25 2901 0611 00 5 Manual drain valve kit
26 1617 7082 01 2 26 1617 7082 01 2 26 1617 7082 01 2 Male coupling, G 1/8”
26 1617 7082 02 2 26 1617 7082 02 2 26 1617 7082 02 2 Female coupling, G 1/8”
26 1617 7082 03 2 26 1617 7082 03 2 26 1617 7082 03 2 Hose connection
27 8055 2600 64 2/3 1 27 8055 2600 64 2/3 1 27 8055 2600 64 2/3 1 Dual pressure transmitter
28 8055 2600 31 2/6 1 28 8055 2600 31 2/6 1 28 8055 2600 31 2/6 1 EWD Connection
28 8055 2600 49 2/7 1 28 8055 2600 49 2/7 1 28 8055 2600 49 2/7 1 EWD Connection
28 8055 2600 56 2/8 1 28 8055 2600 56 2/8 1 28 8055 2600 56 2/8 1 EWD Connection

Notes
1. Included in the element kit. 4. Only on DDx and PDx filters. 7. 115V 50/60Hz not on DDxp, PDxp and QDx filters.
2. Optional. 5. Only on DDxp, PDxp and QDx filters. 8. 24V 50/60Hz not on DDxp, PDxp and QDx filters.
3. Not on QDx filters. 6. 230V 50/60Hz not on DDxp, PDxp and QDx filters.

2904 0183 00 75
DDX - DDXP - PDX - PDXP - QDX : 55 - 75

11 1a

22
25
8 6 24
9
10 20 4
6
28
21
1

5
12

2
27

26

DDx - DDxp - PDx - PDxp - QDx : 55 DDx - DDxp - PDx - PDxp - QDx : 75
Ref. Part Number Note Qty Ref. Part Number Note Qty Designation
– 8102 2652 98 – 8102 2653 48 DDx filter complete
– 8102 2653 06 – 8102 2653 55 DDxp filter complete
– 8102 2652 64 – 8102 2653 14 PDx filter complete
– 8102 2652 72 – 8102 2653 22 PDxp filter complete
– 8102 2652 80 – 8102 2653 30 QDx filter complete
– 2901 1214 00 – 2901 1217 00 DDx and DDxp element kit
– 2901 1212 00 – 2901 0868 00 PDx and PDxp element kit
– 2901 1213 00 – 2901 1216 00 QDx element kit
1 – 1 1 – 1 Head
1a • 0196 1552 88 2 1a • 0196 1552 88 2
2 – 1 2 – 1 Bowl
3 – 1 1 3 – 1 1 Filter element
4 0663 2109 60 1 1 4 0663 2109 60 1 1 O-ring, 76x3
5 0663 2109 64 1 2 5 0663 2109 64 1 2 O-ring for filter, 30x2
6 0663 2111 29 1 1 6 0663 2111 29 1 1 O-ring, 18x3,5
7 1617 7046 00 1 7 1617 7046 00 1 Nut, G3/8”
8 8055 2600 72 2/3 8 8055 2600 72 2/3 Differential press. indicator
9 8055 2600 80 2/3 1 9 8055 2600 80 2/3 1 Differential press. gauge
10 – 1 10 – 1 Identification label
11a 8055 2600 98 2/3 1 11a 8055 2600 98 2/3 1 Potential free contact, normally open
11b 8055 2601 06 2/3 1 11b 8055 2601 06 2/3 1 Potential free contact, normally closed
12 0690 1106 01 2 12 0690 1106 01 2 Atlas Copco decal
20 8092 2429 76 2 20 8092 2429 76 2 Wall mounting kit
21 8092 2430 24 2 21 8092 2430 24 2 Serial connection kit
22 • 0663 2101 97 1 22 • 0663 2101 97 1 O-ring, 38x2
24 2901 0563 00 4 24 2901 0563 00 4 Automatic drain valve kit
25 2901 0611 00 5 25 2901 0611 00 5 Manual drain valve kit
26 1617 7082 01 2 26 1617 7082 01 2 Male coupling, G 1/8”
26 1617 7082 02 2 26 1617 7082 02 2 Female coupling, G 1/8”
26 1617 7082 03 2 26 1617 7082 03 2 Hose connection
27 8055 2600 64 2/3 1 27 8055 2600 64 2/3 1 Dual pressure transmitter
28 8055 2600 31 2/6 1 28 8055 2600 31 2/6 1 EWD Connection
28 8055 2600 49 2/7 1 28 8055 2600 49 2/7 1 EWD Connection
28 8055 2600 56 2/8 1 28 8055 2600 56 2/8 1 EWD Connection

Notes
1. Included in the element kit. 5. Only on DDxp, PDxp and QDx filters.
2. Optional. 6. 230V 50/60Hz not on DDxp, PDxp and QDx filters.
3. Not on the QDx filters. 7. 115V 50/60Hz not on DDxp, PDxp and QDx filters.
4. Only on DDx and PDx filters. 8. 24V 50/60Hz not on DDxp, PDxp and QDx filters.

76 2904 0183 00
DDX - DDXP - PDX - PDXP - QDX : 145 - 190 - 220

11 1a

22
25
8 6 24
9
10 20 4
6
28
21
1

5
12

2
27

26

DDx - DDxp - PDx - PDxp - QDx : 145 DDx - DDxp - PDx - PDxp - QDx : 190 DDx - DDxp - PDx - PDxp - QDx : 220
Ref. Part Number Note Qty Ref. Part Number Note Qty Ref. Part Number Note Qty Designation
– 8102 2653 97 – 8102 2654 47 – 8102 2654 96 DDx filter complete
– 8102 2654 05 – 8102 2654 54 – 8102 2655 04 DDxp filter complete
– 8102 2653 63 – 8102 2654 13 – 8102 2654 62 PDx filter complete
– 8102 2653 71 – 8102 2654 21 – 8102 2654 70 PDxp filter complete
– 8102 2653 89 – 8102 2654 39 – 8102 2654 88 QDx filter complete
– 2901 1220 00 – 2901 1223 00 – 2901 1226 00 DDx and DDxp element kit
– 2901 1218 00 – 2901 1221 00 – 2901 1224 00 PDx and PDxp element kit
– 2901 1219 00 – 2901 1222 00 – 2901 1225 00 QDx element kit

1 – 1 1 – 1 1 – 1 Head
1a • 0196 1552 88 2 1a • 0196 1552 88 2 1a • 0196 1552 88 2
2 – 1 2 – 1 2 – 1 Bowl
3 – 1 1 3 – 1 1 3 – 1 1 Filter element
4 0663 2109 61 1 1 4 0663 2109 61 1 1 4 0663 2109 61 1 1 O-ring, 108x3
5 0663 2101 01 1 2 5 0663 2101 01 1 2 5 0663 2101 01 1 2 O-ring for filter, 40x2
6 0663 2111 29 1 1 6 0663 2111 29 1 1 6 0663 2111 29 1 1 O-ring, 18x3,5
7 1617 7046 00 1 7 1617 7046 00 1 7 1617 7046 00 1 Nut, G3/8”
8 8055 2600 72 2/3 8 8055 2600 72 2/3 8 8055 2600 72 2/3 Differential press. indicator
9 8055 2600 80 2/3 1 9 8055 2600 80 2/3 1 9 8055 2600 80 2/3 1 Differential press. gauge
10 – 1 10 – 1 10 – 1 Identification label
11a 8055 2600 98 2/3 1 11a 8055 2600 98 2/3 1 11a 8055 2600 98 2/3 1 Potential free contact
Normally open
11b 8055 2601 06 2/3 1 11b 8055 2601 06 2/3 1 11b 8055 2601 06 2/3 1 Potential free contact
Normally closed
12 0690 1101 23 2 12 0690 1101 23 2 12 0690 1101 23 2 Atlas Copco decal

20 8092 2429 84 2 20 8092 2429 84 2 20 8092 2429 84 2 Wall mounting kit


21 8092 2430 32 2 21 8092 2430 32 2 21 8092 2430 32 2 Serial connection kit
22 • 0663 2104 75 1 22 • 0663 2104 75 1 22 • 0663 2104 75 1 O-ring, 52,96x2,5
24 2901 0563 00 4 24 2901 0563 00 4 24 2901 0563 00 4 Automatic drain valve kit
25 2901 0611 00 5 25 2901 0611 00 5 25 2901 0611 00 5 Manual drain valve kit
26 1617 7082 01 2 26 1617 7082 01 2 26 1617 7082 01 2 Male coupling, G 1/8”
26 1617 7082 02 2 26 1617 7082 02 2 26 1617 7082 02 2 Female coupling, G 1/8”
26 1617 7082 03 2 26 1617 7082 03 2 26 1617 7082 03 2 Hose connection
27 8055 2600 64 2/3 1 27 8055 2600 64 2/3 1 27 8055 2600 64 2/3 1 Dual pressure transmitter
28 8055 2600 31 2/6 1 28 8055 2600 31 2/6 1 28 8055 2600 31 2/6 1 EWD Connection
28 8055 2600 49 2/7 1 28 8055 2600 49 2/7 1 28 8055 2600 49 2/7 1 EWD Connection
28 8055 2600 56 2/8 1 28 8055 2600 56 2/8 1 28 8055 2600 56 2/8 1 EWD Connection

Notes
1. Included in the element kit. 4. Only on DDx and PDx filters. 7. 115V 50/60Hz not on DDxp, PDxp and QDx filters.
2. Optional. 5. Only on DDxp, PDxp and QDx filters. 8. 24V 50/60Hz not on DDxp, PDxp and QDx filters.
3. Not on the QDx filters. 6. 230V 50/60Hz not on DDxp, PDxp and QDx filters.

2904 0183 00 77
DDX - DDXP - PDX - PDXP - QDX : 325

11 1a

22
25
8 6 24
9
10 20 4
6
28
21
1

5
12

2
27

26

DDx - DDxp - PDx - PDxp - QDx : 325


Ref. Part Number Note Qty Designation
– 8102 2655 46 DDx filter complete
– 8102 2655 53 DDxp filter complete
– 8102 2655 12 PDx filter complete
– 8102 2655 20 PDxp filter complete
– 8102 2655 38 QDx filter complete
– 2901 1229 00 DDx and DDxp element kit
– 2901 1227 00 PDx and PDxp element kit
– 2901 1228 00 QDx element kit
1 – 1 Head
1a • 0196 1552 88 2
2 – 1 Bowl
3 – 1 1 Filter element
4 0663 2109 62 1 1 O-ring, 129,7x3,5
5 0663 2109 66 1 2 O-ring for filter, 61,6x2,6
6 0663 2111 29 1 1 O-ring, 18x3,5
7 1617 7046 00 1 Nut, G3/8”
8 8055 2600 72 2/3 Differential press. indicator
9 8055 2600 80 2/3 1 Differential press. gauge
10 – 1 Identification label
11a 8055 2600 98 2/3 1 Potential free contact, normally open
11b 8055 2601 06 2/3 1 Potential free contact, normally closed
12 0690 1100 01 2 Atlas Copco decal
20 8092 2429 92 2 Wall mounting kit
21 8092 2430 40 2 Serial connection kit
22 • 0663 2104 98 1 O-ring, 80x3 - 94,5x3
24 2901 0563 00 4 Automatic drain valve kit
25 2901 0611 00 5 Manual drain valve kit
26 1617 7082 01 2 Male coupling, G 1/8”
26 1617 7082 02 2 Female coupling, G 1/8”
26 1617 7082 03 2 Hose connection
27 8055 2600 64 2/3 1 Dual pressure transmitter
28 8055 2600 31 2/6 1 EWD Connection
28 8055 2600 49 2/7 1 EWD Connection
28 8055 2600 56 2/8 1 EWD Connection

Notes
1. Included in the element kit. 7. 115V 50/60Hz not on DDxp, PDxp and QDx filters.
2. Optional. 8. 24V 50/60Hz not on DDxp, PDxp and QDx filters.
3. Not on the QDx filters.
4. Only on DDx and PDx filters.
5. Only on DDxp, PDxp and QDx filters.
6. 230V 50/60Hz not on DDxp, PDxp and QDx filters.

78 2904 0183 00
DDX - DDXP - PDX - PDXP - QDX : 480 - 650

11 1a

22
25
8 6 24
9
10 20 4
6
28
21
1

5
12

2
27

26

DDx - DDxp - PDx - PDxp - QDx : 480 DDx - DDxp - PDx - PDxp - QDx : 650
Ref. Part Number Note Qty Ref. Part Number Note Qty Designation
– 8102 2655 95 – 8102 2656 45 DDx filter complete
– 8102 2656 03 – 8102 2656 52 DDxp filter complete
– 8102 2655 61 – 8102 2656 11 PDx filter complete
– 8102 2655 79 – 8102 2656 29 PDxp filter complete
– 8102 2655 87 – 8102 2656 37 QDx filter complete
– 2901 1232 00 – 2901 1235 00 DDx and DDxp element kit
– 2901 1230 00 – 2901 1233 00 PDx and PDxp element kit
– 2901 1231 00 – 2901 1234 00 QDx element kit
1 – 1 1 – 1 Head
1a • 0196 1552 88 2 1a • 0196 1552 88 2
2 – 1 2 – 1 Bowl
3 – 1 1 3 – 1 1 Filter element
4 0663 2109 63 1 1 4 0663 2109 63 1 1 O-ring, 158,3x3,5
5 0663 2109 67 1 2 5 0663 2109 67 1 2 O-ring for filter, 72,7x2,6
6 0663 2111 29 1 1 6 0663 2111 29 1 1 O-ring, 18x3,5
7 1617 7046 00 1 7 1617 7046 00 1 Nut, G3/8”
8 8055 2600 72 2/3 8 8055 2600 72 2/3 Differential press. indicator
9 8055 2600 80 2/3 1 9 8055 2600 80 2/3 1 Differential press. gauge
10 – 1 10 – 1 Identification label
11a 8055 2600 98 2/3 1 11a 8055 2600 98 2/3 1 Potential free contact, normally open
11b 8055 2601 06 2/3 1 11b 8055 2601 06 2/3 1 Potential free contact, normally closed
12 0690 1112 01 2 12 0690 1112 01 2 Atlas Copco decal
20 8092 2430 08 2 20 8092 2430 08 2 Wall mounting kit
21 8092 2430 57 2 21 8092 2430 57 2 Serial connection kit
22 • 0663 7143 00 1 22 • 0663 7143 00 1 O-ring, 80x3 - 94,5x3
24 2901 0563 00 4 24 2901 0563 00 4 Automatic drain valve kit
25 2901 0611 00 5 25 2901 0611 00 5 Manual drain valve kit
26 1617 7082 01 2 26 1617 7082 01 2 Male coupling, G 1/8”
26 1617 7082 02 2 26 1617 7082 02 2 Female coupling, G 1/8”
26 1617 7082 03 2 26 1617 7082 03 2 Hose connection
27 8055 2600 64 2/3 1 27 8055 2600 64 2/3 1 Dual pressure transmitter
28 8055 2600 31 2/6 1 28 8055 2600 31 2/6 1 EWD Connection
28 8055 2600 49 2/7 1 28 8055 2600 49 2/7 1 EWD Connection
28 8055 2600 56 2/8 1 28 8055 2600 56 2/8 1 EWD Connection

Notes
1. Included in the element kit. 7. 115V 50/60Hz not on DDxp, PDxp and QDx filters.
2. Optional. 8. 24V 50/60Hz not on DDxp, PDxp and QDx filters.
3. Not on QDx filters.
4. Only on DDx and PDx filters.
5. Only on DDxp, PDxp and QDx filters.
6. 230V 50/60Hz not on DDxp, PDxp and QDx filters.

2904 0183 00 79
What sets Atlas Copco apart as a company is our
conviction that we can only excel in what we do if we
provide the best possible know-how and technology to
really help our customers produce, grow and succeed.
There is a unique way of achieving that - we simply call
it the Atlas Copco way. It builds on interaction, on long-
term relationships and involvement in the customers'
process, needs and objectives. It means having the
flexibility to adapt to the diverse demands of the people we
cater for.
It's the commitment to our customers' business that
drives our effort towards increasing their productivity
through better solutions. It starts with fully supporting
existing products and continuously doing things better, but
it goes much further, creating advances in technology
through innovation. Not for the sake of technology, but for
the sake of our customer's bottom line and peace-of-mind.
That is how Atlas Copco will strive to remain the first
choice, to succeed in attracting new business and to
maintain our position as the industry leader.
No. 2904 0183 00/ DC 2004.05

You might also like