You are on page 1of 2

Always Innovative. Always Reliable.

Marco 286 Airline Filter


Built Marco Tough

» ENHANCED SAFETY
A rugged, ring stabilizer base
minimizes tipping hazards
associated with three legged bases.

» ADVANCED FILTRATION
A seven stage filtration process catches and
removes moisture, odors, organic vapors,
and other particles from the air supply, which
provides cleaner breathing or source air.

» APPLICATION VERSATILITY
The 286 Airline Filters are capable of supplying
up to six outlets with a single filter.

Stable ring base reduces tipping The offset position of the petcock provides One of the only Air Filters on the Market
hazards and increases blasting time by quick and easy access for draining which allows for three configurations.
minimizing the amount of time needed to purposes. Single outlet, dual outlet, and six outlet
verify the unit is still upright. options available.

ABRASIVES | BLASTING | ENGINEERED SYSTEMS | PAINTING | RENTAL | SAFETY | SERVICE


Marco 286 Airline Filter
Enhanced Safety, Advanced Filtration, Application Versatility

Competitor Product Comparison


Marco C A R
Number of Outlets 1-6 1-4 1-6 1-6
Base Style Ring Stabilizer Four legs Three Legs Four Legs
Bade Material Steel Plastic Steel Plastic
Max Air Flow Rate Up to 100 CFM Up to 75 CFM Up to 100 CFM Up to 75 CFM
Paint Finish Powder-Coat Wet-Coat Wet-Coat Wet-Coat

» MODEL CONFIGURATIONS » FILTER TYPE » FILTER CARTRIDGE REPLACEMENT


• Two outlet, regulated Seven stage cartridge filter element The frequency of filter cartridge
flange with eight bolt holes replacement depends on the
• Six outlet, regulated conditions of the particular air system
» FILTER OPERATION in which the filter is installed.
• 1” full flow, non-regulated 1. Moisture condenses on the wall of
the tank However, the filter cartridge should be
» MAXIMUM AIRFLOW FILTER CAPACITY replaced immediately if:
• 75 cfm* (2120 lpm) 2. Carded cotton traps particles a. The user smells or tastes
contaminants in the air being
• 75 cfm* (2120 lpm) 3. Activated alumina absorbs moisture supplied to an air-supplied
and oil respirator, or;
• 100
cfm* (2830 lpm)
4. Activated charcoal absorbs odors b. There is a large pressure drop in the
• * cfm rating at maximum and moisture system, even though the compressor
recommended pressure of and other components appear to
100 psig (6.9 bar) 5. Felt catches particles and debris be operating correctly.
6. Carded cotton traps particles

7. Respiratory felt acts as the final


filter

FOR MORE INFORMATION CALL


© 2010 Marco 1050045 0610

800.BLAST.IT | 800.252.7848

800.BLAST.IT | 800.252.7848 | Fax: 563.324.6258 | www.marco.us | Email: sales@marco.us