You are on page 1of 16

S-LCY-B33

High Performance Liquid Chromatograph

i-Series
Living LC
Dual-Temperature Dual-Temperature
Control with TC-Optics
Control
andwith
FlowTC-Optics
Cells and Flow Cells

Excellent Baseline
Excellent
Stability
Baseline Stability

°C °C In addition to the temperature


In addition to the temperature
mAU mAU
Room temperature Room temperature 35 35
control function for flow
control
cells, function
the for flow cells, the

40 40 i-Series employs new temperature


i-Series employs new temperature
30 30
control technology for control
detector
technology for detector
30 30
25 Non-Shimadzu system 25 optical systems,
Non-Shimadzu system knownoptical
as systems, known as
(UV detector) (UV detector)
Fluctuation range: TC-Optics (Temperature
Fluctuation range: TC-Optics (Temperature
20 20
Approx. 27.5 mAU 20 Approx. 27.5 mAU
20 Controlled Optics). ThisControlled
ensures a Optics). This ensures a

10 10
more stable baseline that
moreis less
stable baseline that is less

LC-2050C (UV)
susceptible
LC-2050C (UV)
to room temperature
susceptible to room temperature
0 0 Fluctuation range: Fluctuationand
variation range:
increasedvariation
precisionand increased precision
Approx. 1.3 mAU Approx. 1.3 mAU
0 50 100 0150 50
200 100
250 150
300 200min 250 300 min during verification testing
during
andverification testing and
quantitative testing of quantitative
trace testing of trace
components. components.

Ultra-Low Carryover
Ultra-Low
Performance
Carryover
Enables
Performance
High-Sensitivity
Enables Analysis
High-Sensitivity Analysis

Improved Reliability
Improved of Reliability
Trace Component
of TraceAnalysis
Component Analysis

Shimadzu’s proprietaryShimadzu’s
flow channel
proprietary
design, parts,
flow and
channel
materials
design,
reduce
parts,the
andcarryover
materialseffects
reduceofthe
sample
carryover
residue
effects
to of sample residue to
almost zero. Ultra-low carryover
almost zero.
performance
Ultra-low carryover
has been performance
improved to 0.0025%
has been(chlorhexidine,
improved to 0.0025%
assigned(chlorhexidine,
conditions), assigned conditions),
thereby providing highly
thereby
preciseproviding
quantitative
highly
performance
precise quantitative
when analyzing
performance
complex
when
samples.
analyzing complex samples.

mAU mAU
µAU µAU

1500 1500
100 100

1250 1250
80 80

1000 1000
60 60

750 750
40 40

500 500

20 20
250 250
0 0

0 0 0.9 1.0 1.1 0.9min 1.0 1.1 min

0.85 0.90 0.95 1.00 1.05


0.85 1.10
0.90 1.15
0.95 min
1.00 1.05 1.10 1.15 min

Chromatogram after injecting


Chromatogram
chlorhexidine
after injecting chlorhexidine Chromatogram after injecting
Chromatogram
a blank sample
after injecting a blank sample
(mobile phase) (mobile phase)

14 14
Data management
Data management

ompliant with
Compliant
ER/ES Guidelines
with ER/ESand
Guidelines
Data Integrity
and Data Integrity

bSolutions has a variety


LabSolutions
of functions
has to
a variety
ensure of
compliance
functionswith
to ensure
FDA 21
compliance
CFR Part 11
with
andFDA
Japanese
21 CFRMinistry
Part 11 and
of Health,
Japanese Ministry of Health,
bour and Welfare guidelines
Labour and
on electronic
Welfare guidelines
records and
on electronic
electronic records
signatures.
and LabSolutions
electronic signatures.
also includes
LabSolutions
functionsalso includes functions
at address and support
thatdata
address
integrity.
and support data integrity.

entralized Management
Centralized Management
of Data and of Data and
ser Information
User Information

ta and user information


Dataare
andmanaged
user information
on a database
are managed
with on a database with
Method creation Method creation
Method change AnalysisMethodRe-analysis
change Analysis
Compile data Re-analysis Compile data
trictions on data filerestrictions
deletion andon adata
version
file deletion
number and a version number
nagement function management
that ensures safe
function
storage.
thatFurther
ensures safe
- storage. Further -
re, fine-grained division
more,offine-grained
operational division
restrictions
of operational
allows restrictions allows
timum user management
optimum
based
user
onmanagement
role, such as based
systemon role, such as system
ministrator, analysis administrator,
operator, etc. analysis
LabSolutions
operator,
records
etc. LabSolutions records
An “audit trail” that records
Anall
“audit
operations
trail” that records all operations
e access status of thethe
system,
accesschanges
status oftothe
data
system,
and methods,
changes to data and methods,
erations performed operations
during analysis
performed
and re-analysis,
during analysis and re-analysis,
anges to system settings,
changes
etc.to system settings, etc.

eview of Operation
Review of
Logs
Operation Logs

eport set function compiles


A reportanalytical
set function
conditions
compilesoranalytical conditions or
Batch reports Batch reports
analytical
alytical results/conditions results/conditions
for sets of analysis (batch
for sets of analysis (batch Other reports Other reports

alysis) and also compiles


analysis)
operation
and also
logs
compiles
from start
operation
to logs from start to
mpletion of analysis.completion
The report of
setanalysis.
functionThe
automatically
report set function automatically
lects information, prevents
collects the
information,
accumulation
prevents
of arbitrary
the accumulation of arbitrary
Data reports Data reports
ports and prevents operational
reports anderrors.
prevents operational errors. Audit trails Audit trails

eamless Integration
SeamlessofIntegration
Testing andofAnalysis
Testing and Analysis

bSolutions i-QLinks LabSolutions



can create test
i-QLinks
plans ™and
cantest
create
items,
testincorporate
plans and test
results
items,
from
incorporate
tests performed
results on
from
HPLC
tests
systems
performed on HPLC systems
d other analytical instruments,
and other analytical
automatically
instruments,
create test
automatically
reports based
create
on test
test results
reportsfrom
based
all on
kinds
testofresults
analytical
from all kinds of analytical
truments and manage
instruments
the progress
andstatus
manageof quality
the progress
testing.
status of quality testing.

15 15
i-Series

The Analytical Intelligence logo, LabSolutions and i-QLinks are trademarks of Shimadzu Corporation.
QR Code is a registered trademark of Denso Wave Inc.

For Research Use Only. Not for use in diagnostic procedures.


This publication may contain references to products that are not available in your country. Please contact us to check the availability of
these products in your country.
Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation,
its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.
Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether
Shimadzu (Asia Pacific) Pte Ltd. or not they are used with trademark symbol “TM” or “®”.
Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.

www.shimadzu.com.sg/an The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice.
Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.

© Shimadzu (Asia Pacific) Pte Ltd., 2021 First Edition: May 2021
© Shimadzu Corporation, 2021 First Edition: November 2020 3655-01105-PDFNS, C196-E098A

You might also like