You are on page 1of 11

ELCO I 80

Test unit for Numbering boxes with Impulse Scanning

Operator’s Manual

ATLANTIC ZEISER GmbH ATLANTIC ZEISER Inc.


Bogenstraße 6 - 8 15 Patton Drive - West Caldwell
D - 78576 Emmingen - Germany New Jersey 07006 - USA
Telefon ++49 7465 291-0 Phone ++1 973 228-0800
Telefax ++49 7465 291-166 Fax ++1 973 228-9064
E-mail; Sales@AtlanticZeiser.com E-mail; Sales@AtlanticZeiserUSA.com
http://www.AtlanticZeiser.com http://www.AtlanticZeiserUSA.com
ELCO I 80 for Impulse Scanning

Erste Auflage / First issue Februar 1999


Datei-Nr. / File nr. elco_i80_gb.fm
Dokumentname / Document name ELCO I 80 for Impulse Scanning
Auftragsnummer / Commission No. --
Autor / Author

All rights reserved. No part of this document may be reproduced or transmitted in any form or by any
means, electronic or mechanical, including photocopying, recording, or by any information storage
and retrieval system, without written permission from ATLANTIC ZEISER.

ATLANTIC ZEISER GmbH ATLANTIC ZEISER Inc.


Bogenstraße 6 - 8 15 Patton Drive - West Caldwell
D - 78576 Emmingen - Germany New Jersey 07006 - USA
Telefon ++49 7465 291-0 Phone ++1 973 228-0800
Telefax ++49 7465 291-166 Fax ++1 973 228-9064
E-mail; Sales@AtlanticZeiser.com E-mail; Sales@AtlanticZeiserUSA.com
http://www.AtlanticZeiser.com http://www.AtlanticZeiserUSA.com

Datei-Nr.: elco_i80_gb.fm Februar 1999


ELCO I 80 for Impulse Scanning

Table of Contents
Chap. Contents Page

1. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Part list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 Putting into operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

2. Safety hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3. Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.1 ELCO test unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Power unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4. Test of a numbering box with IMPULSE scanning


without "RISEC" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.2 Test function scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.3 Test function alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.4 Selection language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

5. Test of a numbering box with IMPULSE scanning and a RISEC . 7


5.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2 Test function "scanning" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

6. Test of initiators LR-LA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Datei-Nr.: elco_i80_gb.fm Februar 1999


ELCO I 80 for Impulse Scanning

Operating instruction ELCO I 80

1. General

1.1 Operation

The ELCO I 80 testing unit can be used for static testing of num-
bering boxes with IMPULS scanning and for testing of ring elec-
tronics (RISEC). The numbering box with scanning can either be
connected directly in the ELCO unit or over the so-called ring
electronic (RISEC) with the ELCO unit.

1.2 Part list

The complete unit consists of following parts:


- 1 ELCO I 80 unit
- 1 Power Supply unit for 220V/35 VA
- 1 Cable 10 pole for the box scanning
- 1 Cable 25 pole for the RISEC-ELCO connection

1.3 Putting into operation

The ELCO unit is connected by means of the cable and the7 pole
plug (5) of the power supply unit.
The numbering box scanning is connected by means of the 10
pole plug connection (13) directly with the ELCO unit.

In the other case (test with a RISEC) the cable of the numbering
box can for example be plugged in the plug position -1- of the
RISEC. The RISEC is directly connected by means of the 26 pole
- 25 pole connection cable with the ELCO unit. (Plug 25 pole
(11)).

Datei-Nr.: elco_i80_gb.fm Februar 1999 1


ELCO I 80 for Impulse Scanning

2. Safety hints

- -Never use faulty cabling or faulty plug connector.

- Never open the unit, if it is switched on.

Warn in g
- Don’t change plug connections, as long as the unit is switched
on.

Datei-Nr.: elco_i80_gb.fm Februar 1999 2


ELCO I 80 for Impulse Scanning

3. Operating instructions

3.1 ELCO test unit

11
8 10
7 12

9 13
14
6 5 4 2 1 3

1 ELCO I 80 unit
2 LCD-display for 2x40 characters
3 16-digit keyboard with 6 function keys.
Function of keys: A = Cursor backwards;
B = Cursor forward
C = Function Start/End
D+E = open
F = Test function start
4 LED display F1 (LR)
5 LED display F2 (LA)
6 LED display F3 (is not used)
7 Side view right-hand
Plug connection7 pole for the connection of the external
power part.
9 Plug connection 9 pole -D- (is not used).
10 Side view lefthand
11 Plug connection 25 pole -D- for the plug connection to the
ring electronic (RISEC).
12 Plug connection 3 pole for the connection of an initiator -
LR-.
13 Plug connection 10 pole for the connection of the number-
ing box scanning.
14 Plug connection 3 pole for the connection of an initiator -
LA-.

Datei-Nr.: elco_i80_gb.fm Februar 1999 3


ELCO I 80 for Impulse Scanning

3.2 Power unit

2 3

4 5

(1) Power supply unit 220V/35VA

(2) Power supply ON-OFF-switch

(3) Power supply fuse 0,4A

(4) Power supply plug

(5) Connection plug 5 pole for the ELCO-equipment.

Datei-Nr.: elco_i80_gb.fm Februar 1999 4


ELCO I 80 for Impulse Scanning

4. Test of a numbering box with IMPULSE scanning without


"RISEC"

4.1 General

At first all connection lines must be made (also regard putting into
operation).
Thereafter the power plug (2) at the power supply unit is switched
on. On the LCD-display of the ELCO-unit following menu is dis-
played:

Scanning ATLANTIC/Z E I S E R ELCO


ABF Version: .I... 1000

By means of keys (A) and (B) the operator may select the possi-
ble test functions. The corresponding function is then displayed in
the indication field.
By means of key (F) the test function is started.
Following test functions are possible:
- Scanning (figure control)
- Alignment
- Language (English, Italian, French, German).

4.2 Test function scanning

By means of key (B) the function scanning is selected and by


means of key (F) the function is started. The LCD display follow-
ing menu appears in the LCD display:

Scanning Ring 0 Box 0


BC Test RRRRRRR

In the original state Ring 0 Box 0 appears in the display, and the
box interface (13) of the ELCO unit is selected. The connected
numbering box is then tested. The electronic reads the numbering
box with the scanning frame. Through rotating of the correspond-
ing scanned figure wheels the test result is displayed in the indi-
cation.

Datei-Nr.: elco_i80_gb.fm Februar 1999 5


ELCO I 80 for Impulse Scanning

Following test results are possible:


- R = Wheel is correctly in position.
- ? = Half-position of the corresponding wheel.
- ??????? = Numbering box not connected.
.By means of key (C) the test function can be stopped.

4.3 Test function alignment

By means of key (B) the function alignment is selected and by


means of key (F) the function is started. On the indication follow-
ing menu is displayed then:

Alignment Ring 0 Box 0


BC Test PPPPPPP

In the original state Ring 0 Box 0 appears in the display, and the
box interface (13) of the ELCO unit is selected. The connected
numbering box is then tested and the resulting value appears in
the LCD display.
- P = Figure wheel is correctly positioned.
- * = Figure wheel is out of the tolerance.
The corresponding scanned figure wheels are rotated until the
displayed character (-P-) changes to character (*) is displayed in
the indication. The distance measured on the figure wheel
between position (P) and position (*) is then the tolerance.
By means of key C the test function can be left.

4.4 Selection language

By means of key (B) the menu for language is selected and by


means of key (F) the function is started and following menu is dis-
played:

Language English
BC

By means of key (B) the language is selected and by means of


key (C) the menu can be left again.

Datei-Nr.: elco_i80_gb.fm Februar 1999 6


ELCO I 80 for Impulse Scanning

5. Test of a numbering box with IMPULSE scanning and a


RISEC

5.1 General

At first all connection lines must be made, that means the connec-
tion line between the RISEC (26 pole) and the ELCO output plug
(11) 25 pole. Moreover a numbering box cable must be plugged
for example into plug position BOX 1.
Thereafter the power switch (2) at power supply unit can be
switched on.
On the indication of the ELCO-unit following menu is displayed:

Scanning ATLANTIC/Z E I S E R ELCO


ABF Version: .I... 1000

By means of key (F) function "scanning" is started.

5.2 Test function "scanning"

After the selection following menu is displayed on the indication:

Scanning Ring 0 Box 0


BC Test RRRRRRR

By means of key (B) the ring is selected (cursor flashes) and the
value 1 is typed in, that means, ring 1 is selected. Thereafter by
means of key (B) the box is selected (cursor flashes) and the
value 1 is typed in. Thereafter press key (B) again (Values are
taken over). Thus plug place 1 is selected.

Remark:
The selection of other box plug positions from 1-12 is possible
and thus testing the RISEC by means of one box through plugging
the box in the corresponding plug positions.

All other test functions are equal as described under point 3.

Datei-Nr.: elco_i80_gb.fm Februar 1999 7


ELCO I 80 for Impulse Scanning

6. Test of initiators LR-LA

The initiators can be tested through plugging initiator LR into plug


position (12) or initiator LA into plug position (14). The display of
function LR and LA takes place by means of light emitting diodes
F1 (6) and F2 (5).