Transit details
Sample 221442811
ISO-F Grade( 2010/12 ) RMG380VLS RMG380VLS
Density @ 15°c ISO 12185 kg/l 0.9910 Max 0.9335
K Viscosity at 50°C ISO 3104 cSt 380 Max 87.0
Flash Point ASTM D6450 °C 60 Min > 70.0
Pour Point ISO 3016 °C 30 Max 15
Micro Carbon Residue ISO 10370 %m/m 18.0 Max 7.21
Ash Content at 550°C ISO 6245 %m/m 0.10 Max 0.022
Water Content ASTM D6304 %v/v 0.50 Max 0.05
Sulphur Content ISO 8754 %m/m 0.42 0.41
Total Sediment ISO 10307-2B %m/m 0.10 Max < 0.01
Vanadium IP 501 mg/kg 350 Max 2
Sodium IP 501 mg/kg 100 Max 2
Aluminium IP 501 mg/kg - 2
Silicon IP 501 mg/kg - 2
Aluminium + Silicon Calc mg/kg 60 Max 4
Calcium IP 501 mg/kg 30 Max 11
Phosphorus IP 501 mg/kg 15 Max <1
Zinc IP 501 mg/kg 15 Max <1
Iron IP 501 mg/kg - 9
Nickel IP 501 mg/kg - 25
Magnesium IP 501 mg/kg - <1
Lead IP 501 mg/kg - <1
Potassium IP 501 mg/kg - <1
TAN ASTM D664 mgKOH/g 2.5 Max 0.17
SAN ASTM D664 mgKOH/g - 0.0
CCAI Index Index 870 Max 812
ChemScan In House - - Pass
Page 4 of 5
Calculated values
Green
2. Total Sediment result indicates that the fuel will remain stable during normal storage, handling
and use.
3. Acid Number is considered to be at a satisfactory low level for a marine fuel and would not be
expected to give rise to problems during use.
4. The fuel as tested complies with the Revised MARPOL Annex VI reg. 14.1.3.
The analysis results and subsequent advisory comments in this report are based on the testing of the sample as received
into the laboratory. The sample is provided to us by the client/vessel along with the corresponding sample details stated on
page two of this report.
Note: The accuracy of the results obtained are dependent on the sample tested being truly representative of the fuel as loaded. To draw representative samples please
refer to the FOBAS Sampling Procedures Manual. For further information on the MARPOL Annex VI Reg. 14 & 18 requirements and its on-going developments, please
contact your local Lloyd's Register FOBAS office or contact us directly on fobas@lr.org
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as
'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or
advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or
advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.
Stats Appendix
Flash Point °C > 70.0 > 70.0 > 70.0 > 70.0
Pour Point °C 15 24 15 21
Vanadium mg/kg 2 10 6 17
Sodium mg/kg 2 22 4 17