Professional Documents
Culture Documents
BOSCOSEAL AC2
One Part Fibre Reinforced Waterproofing Membrane
PAGE 1
Non porous surfaces such as existing tiles and burnished 5. INTERNAL WET AREAS –
concrete will require priming with Bostik Ultra NP Primer. SEALING CORNERS & WASTE OUTLETS
Metal surfaces and PVC pipes should be primed with
Do not use polyurethane based sealants in these
Bostik 5077 primer.
applications.
All designated primers must be applied in accordance with
Ensure falls required in the screed to shower recess
the current applicable primer technical data sheet.
base, pipe outlets, angles and drainage is installed
For pre-treated or suspect surfaces, contact Bostik
correctly.
technical service.
All corners and substrate gaps around taps, shower
outlets, waste outlets, pipes, drains, flashings and
2. SUBSTRATE nail/screw holes must be sealed using Bostik Neutral
All surfaces must be primed. Cure Silicone or Simson SMP sealants.
Before the application of Boscoseal AC2 all surfaces
Apply a 10mm bead of sealant by caulking gun directly
must be clean, dry and structurally sound. The substrate
into all wall/floor, hob/floor, hob/wall and wall/wall corners
must be free of voids, curing compounds, sharp objects,
to intending tile height.
laitance, loose material, oils, grease or sealers.
Sealant should be spatula tooled smooth around fittings
New concrete must be cured for 28 days, mortar beds
and pressed into corners creating a triangular fillet.
and cement render cured for 7 days.
Allow sealant to tack off (approximately 30 minutes).
Do not apply over concrete slabs containing high
Apply primers after sealant tack off, to all areas intended
moisture content (above 15%).
for Boscoseal AC2 application.
Holes, non-structural cracks over 5mm and other
particularly rough surfaces should be repaired using a
recommended Bostik floor levelling compound or Bostik 6. SHOWER MEMBRANE APPLICATIONS
Ultrarapid Set polymer repair mortar. Primer applications must be dry.
Very 'boney' or porous concrete must be primed or Walls
moisture sealed prior to any application (see priming). Apply Boscoseal AC2 to the internal wall corners
All cement sheet joins and movement joints designed in extending out 100mm onto each wall of the shower using
base substrates where Boscoseal AC Primer or AC a paintbrush. Ensure all corners are well coated. This
Membranes will be in direct contact must be sealed with must extend past the height of the shower rose. It is
Bostik neutral cure silicone or Simson SMP joint sealants important to coat around any tap body protrusions
prior to membrane application. Sealants must not be through the wet area wall as per AS3740.
applied in, or to, moist or damp surfaces The wall/floor junctions must then be coated extending
Fibrous cement sheeting and plasterboard must be 100mm onto the floor and up the wall 100mm.
installed in accordance with manufacturer’s directions. Where the height of the hob is greater than 75mm, then
the Boscoseal AC2 must extend at least 25mm above the
3. MOISTURE/VAPOUR BARRIER height of the hob.
Boscoseal AC2 must not be applied to surfaces that are Apply Boscoseal AC2 to wall surfaces coating above
moist or damp. Applications to these surfaces can result anticipated shower rose height, covering all previously
in adhesion failure and surface bubbling of the coated wall/wall junctions, wall/floor junctions, and tap
membrane. protrusion surrounds.
Applications requiring access onto moist, 'green' or Shower base
uncured concrete will first require the application of The shower base is to be fully coated. Boscoseal AC2
Bostik Moisture Seal epoxy vapour barrier which will act must be dressed down into the waste at least 50mm.
as a curing compound and moisture transmission barrier. Once the initial coating is dry, recoat the entire area to be
Bostik Moisture Seal must be applied in a two-coat waterproofed, including full cover over the initial coating.
system as per Technical Data Sheet. Boscoseal AC2
must be applied immediately the second coat 'tacks off'. 7. WET AREA FLOOR & EXTERNAL DECKS
If Boscoseal AC2 cannot be applied within 24 hours of
the second coat of Moisture Seal curing, a third coat
APPLICATIONS
Primer applications must be dry
must be applied
If the wet area floor, balcony or deck areas to be coated
are subject to service or other building penetrations, it is
4. CRACKS & NARROW JOINT SEALING recommended, if possible, to install a flanged metal up
All cracks must be cleaned with loose material removed. stand around the penetration.
For cracks and joints up to 5mm apply a bead of Bostik Prime metal up stand with Bostik 5077 primer and seal
Neutral Cure Silicone into the crack and extending 5mm off the perimeter of the penetration with a 10mm bead of
either side. Tool smooth with spatula. Bostik Neutral Cure Silicone.
Once silicone is tack free prime the repair area with Apply Boscoseal AC2 into wastes, drains or onto puddle
Bostik AC Primer to a width of 150mm each side of flanges. Boscoseal AC2 must be dressed down into the
repair. waste at least 50mm.
Allow AC Primer to dry approximately 30 minutes. Apply an initial coat of Boscoseal AC2 either side of all
Apply two coats of Boscoseal AC2 over the primed area wall/floor junctions and sheet flooring joints. Extend the
achieving a minimum dry film thickness of 1.2mm. coating at least 100mm either side of the joins.
Cracks over 5mm must be repaired and designed Once the initial coating is dry, recoat the entire floor area
movement joints sealed as detailed in substrate to be waterproofed, including over the initial coating.
preparation section.
8. ROOF APPLICATIONS
Boscoseal AC2 is recommended as a waterproof membrane
for non-traffic areas. (Application method is the same as for
wet area floors/decks).
These areas of application should not be accessed until
membrane has fully cured.
PAGE 2
TILING AND MORTAR BED COVERING Due to low flexibility, Boscoseal AC2 is not
To eliminate possible surface contamination or damage, it is recommended for planter boxes or areas where high
recommended tiling, mortar bed applications or finished movement is anticipated.
flooring installations be carried out it as soon as possible after Boscoseal AC2 will not span gaps and should only be
full cure of the membrane. These installations may be carried applied to continuous surfaces.
out after the Boscoseal AC2, two-coat system, has been Boscoseal AC water based membranes must not come in
allowed to cure for a minimum of 3 days at a temperature of direct contact with polyurethane sealants in any
25 οC (slightly longer in lower temperatures). application.
Movement joints provided in tiling should be filled with either Any intended use of Boscoseal AC2 outside of specified
Bostik Seal ’N’ Flex 1 or FC polyurethane sealant or Bostik use should be referred to Bostik technical services for
neutral cure anti-fungal silicone sealant. approval.
The information and recommendations relating to the application and end-use of the product are given in good faith and based on tests which we believe to be reliable. However, no warranty in
respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship, whatsoever, can be inferred either from this information, or from any written
recommendations, or from any other advise offered. No guarantee of their accuracy can be made because of the great range of field conditions and variations encountered in raw materials,
manufacturing equipment and methods. Thus, the products are sold with limited warranty only, and on condition that purchasers will make their own tests to determine the suitability of the
product for their particular purposes. Under no circumstances will Bostik be liable to anyone except for replacement of the products or refund of the purchase price.
ALL SALES ARE EXPRESSLY LIMITED TO THE TERMS AND CONDITIONS OF SALE OF BOSTIK COMPANY.
Bostik Findley Malaysia Sdn Bhd Bostik Australia Pty Ltd Bostik New Zealand Pty Ltd Bostik Singapore Pte Ltd
Phone : + 60 6 678 9788 Phone : + 613 9279 9333 Phone : + 644 567 5119 Phone : + 65 6863 4088
Fax : + 60 6 678 9766 Fax : + 613 9279 9240 Fax : + 644 567 5412 Fax : + 65 6863 4077
Bostik China Co. Ltd Bostik Hong Kong Ltd Bostik Thailand Co. Ltd Bostik Phillipines, Inc
Phone : + 86 20 8297 5266 Phone : + 852 3929 9800 Phone : + 662 254 4180 Phone : + 632 900 5656 Applicable for
Fax : + 86 20 3222 6261 Fax : + 852 2510 8380 Fax : + 662 657 0892 Fax : + 632 900 5622 Bostik Australia Pty Ltd
PAGE 3 Product : Boscoseal AC2 • Issue Date : JUNE 2012 • Issue No : 1 • Division : Construction • Total Pages : 3