You are on page 1of 2

GFMJ Series

6GFMJ-50 12V50Ah
GFMJ series gel batteries utlize advanced battery manufacturing technology. It has good cyclic and high-low
temperature performance, special electrolyte design and good charge acceptance ability. GFMJ can be used in
high-low temperature environment with poor grid condition. It is optimal for pure cyclic solar, wind and energy
storage systems.

Benefits
● Very long life according to EUROBAT Classification
● High discharge performance
● High gas recombination efficiency

● Maximum charge efficienc

● GEL state electrolyte prevents leakage and layering

● Low resistance PVC-SiO2 micro-porous separator

ensure Low self-discharge rate


● Easy installation and handling

Applications Drawing
● Telecommunications
● Power system
● Energy storage
● UPS
169

198

● Emergency power

Standards Φ16

● IEC 60896-21/22 M8
IEC61427
174

● DIN43539-T5
57.5

5
● EUROBAT guide

217.5
GFM-24
276

Specifications

Battery Model 6GFMJ-50


Design Life (years, 25℃) 12

10HR (5.0A, 1.80V) 5HR (8.5A, 1.80V) 3HR (12.5A, 1.80V) 1HR(27.5A, 1.80V)
Capacity (Ah, 25℃)
50 42.5 37.5 27.5

Length Width Height Total Height


Dimensions (mm)
276 174 169 198

Approx. Weight (kg) 21.0


Reference Internal Resistance (mΩ) 7.64 ( fully charged @ 25℃)
Maximum Discharge Current (A/3 Sec.) 506
Self-Discharge (25℃) ≤2% per month

Cycle use Float use


Charge Voltage (V/cell, 25℃)
2.33 (-3.5mV/℃/cell), max charge current: 10 A 2.22 (-3.5mV/℃/cell)

Short Circuit Current (A) 1525


www.sacredsun.com

Discharge Data

Constant Current Discharge Data (25℃, A)


End min h
Voltage
(V/cell) 5 10 15 20 30 45 1 1.5 2 3 5 10 20 24 48 100 120 240
1.65 140 102 79 67 49 38 28.9 22.5 17.2 13.10 8.80 5.00 2.70 2.31 1.22 0.63 0.55 0.29
1.70 133 98 78 66 48 37 28.4 22.2 17.2 13.10 8.80 5.00 2.70 2.31 1.22 0.63 0.55 0.29
1.75 125 93 76 64 48 36 28.4 21.8 17.2 13.10 8.80 5.00 2.70 2.31 1.22 0.63 0.55 0.29
1.80 116 87 74 61 46 35 27.9 21.5 17.2 13.10 8.80 5.00 2.70 2.31 1.22 0.63 0.55 0.29
1.85 99 79 69 57 44 34 27.5 20.9 16.7 12.50 8.50 5.00 2.60 2.20 1.22 0.63 0.55 0.29

Constant Power Discharge Data (25℃, W/cell)


End min h
Voltage
(V/cell) 5 10 15 20 30 45 1 1.5 2 3 5 10 20 24 48 100 120 240
1.65 247 185 145 122 91 69 53.4 41.5 32.5 23.60 16.10 9.50 5.10 4.58 2.43 1.25 1.10 0.59
1.70 229 178 142 120 90 68 52.5 41.2 32.5 23.60 16.10 9.40 5.10 4.58 2.43 1.25 1.10 0.59
1.75 210 168 137 118 89 67 52.5 40.8 32.5 23.60 16.10 9.40 5.10 4.58 2.43 1.25 1.10 0.59
1.80 193 156 133 113 87 66 51.5 40.4 32.5 23.60 16.10 9.30 5.10 4.58 2.43 1.25 1.10 0.59
1.85 180 142 127 106 83 63 50.8 39.5 31.7 23.00 15.30 9.10 5.00 4.40 2.43 1.25 1.10 0.59

Performance Curve
)
ell
)
C)

0A

/c
y(%

(I1

(V

4000
ge
nt
cit

rre

lta
pa

cu

vo
ca

3500
ge

ge
ge

ar

ar
ar

Ch

Ch
Ch

3000
120 1.2 2.5

2500 100 1.0 2.4


Cycles

2000 80 0.8 2.3

1-25%DOD
1500 60 0.6 2.2 2-50%DOD
3-75%DOD
4-100%DOD
40 0.4 2.1
1000

20 0.2 2.0
500

0 0 0
0 0 2 4 6 8 10 12 14 16 18 20 22
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% Time(h)
Depth of Discharge(DOD)

Cycle life vs. discharge depth Charge vs. discharge depth

18
120%

15
100%
Design life(years)
Discharge capacity(%)

80% 12

60% 9

40% 6

20% 3

0% 0
-20 -10 0 10 20 30 40 50 20 25 30 35 40 45 50
Temperature(℃) Temperature(℃)

Capacity vs. temperature Design life vs. temperature

Sacred Sun Power Sources Co., ltd. Sacred Sun Asia Pacific Sacred Sun Europe SPRL Sacred Sun MEA FZE

No.1 Shengyang Road Qufu City, PRC No. 15, Yishun Industrial Street 1, Schoenstraat 96-9140 Temse, Belgium S10122A1O19 Jebel Ali, Dubai,
sales@sacredsun.cn #01-17, WIN5, Singapore 768091 sales.eu@sacredsun.cn United Arab Emirates
sales.asia@sacredsun.cn sales.mea@sacredsun.cn