3.3.1.1 No individual, firm, partnership or corporation shall engage in the business of installing, repairing or altering plumbing unless the plumbing work performed in the course of such business is under the direct supervision of a icenseditegistered plumber. 3.3.2 Examination and Certification ‘The Authority shall establish standards and procedure for the qualification, examination and licensing/ registration of plumbers and shall isue licences to such persons who meet the qualifications thereof and successfully pass the examination, 3.3.3 For guidelines for registration of plumbers ‘including the minimum standards for qualifications for the grant of licencesiregistration, reference may be ‘made to good practice [9-1(2)]. The Authority may also utilize the services of the certified plumbers who are certified for the required skill level under the appropriate scheme of the Government. 4 WATER SUPPLY 4.1 Water Supply Requirements for Buildings The total quantity of water per day is estimated based fon the proposed occupancy and activities catered, Designer has to identify all the possible sources for augmenting the shortfall in water supply. The analysis of available water is done to decide the treatment for consumption and treatment process depends on the quality of water and the purpose for which itis used Projection of population for each building shall be made fn the basis ofits usage. Population for each type of building shall be estimated on the basis of information ‘obtained from the users. Alternatively, population may bbe worked on the following basis, for different type of buildings: a) Residential buildings: “Accommodation Population Requirements 1 bedroom dwelling unit 4 2 bedroom dwelling unit 5 3 bedroom dvvelling unit 6 4 bedroom dwelling unit 7 and above ores The above figures consider domestic oats hod incding» suppor pesontel,whezever sie For plated development the popelaion may be tirvd afer due constdrtion ofthe exposed mer and 1ype of domestic housed us, 5 Dmeling unit under EWS extepoy sal have Delain eirmet of and do marvel Ei have population oqiemeat o2 b) Other than residential buildings: ‘Occupancy Population Requirement Offices I person per 10 a of floor area (see Note 1) Strength of school = ‘Teaching and non-teaching staff Hostels Number of beds + 4.5 x (varden’s residence) = staff Hotels. Number of beds + Staff ~ Requirement of restaurant seals Number of beds + Staff = Patient attendants (generally population density per bed in secondary care hospital is 5, tetiary care is 7 and uatemary care is 9) 1 person per 3 mt of street floor and sales basement areas * I person per 6 mé cof upper sale floors (Total population may be segregated into 10 percent for fixed and 90 percent for floating/visitors) Traffic Average number of users terminal per day (Total annual stations passenger traffic!365) + Staff-+ Vendors Schools Hospitals Mercantile ‘ores Wherever there ae mpl work shi, the ‘umber of ser thin & 20h pena may Be ‘onder per scus, 2 Population oa 1s paces, depending on be ‘sage oF bling shal be onside fr Vstos fd oating population Hisly to use the ings fstines 4.1.1 Water Supply for Residences A minimum of 70 to 100 litre per head per day may be considered adequate for domestic needs of urban communities, apart from non-domestic needs as ‘ushing requirements (which varies based on type of ‘building occupancy). As a general rule the following rates per capita per day may be considered for domestic and non-domestic needs: 4) For communities with population up to 20 000: 1) Water supply through stand: 40 Iphd (Min) post 2) Water supply through house; 70 to 100 Iphd serviee connection ») For communities wit: population 20 000 to 100 000 together with full lushing system 100 to 135 Iphd PART 9 PLUMBING SERVICES (INCLUDING SOLID WASTE MANAGEMENT) —SECTION | WATER SUPPLY 11 bok Supply Bureau Under the License from BIS for LARSEN AND TOUBRO CONSTRUCTION - MANAPAKKAM, CHENNAI ON 17-03-2017 09:00:59 (128.6384.36) valid u 3. 63.24.35) valid upto31-12-201 ‘Supplied by Book Supply Bureau Under the License fom IS for LARSEN AND TOUBRO CONSTRUCTION - MANAPAKKAM, CHENNAI ON 17-03-2017 09:00:59 (

You might also like