You are on page 1of 5
e-pac OPERATION & INSTRUCTION MANUAL VERSION V1.1 TO V1.8 auma india } 3] 4 Particulars {Local push butions (For Open—Stop—Close) Indication LED (For Open & Close) Contrel transformer ‘Single phasing protection board (Optional) FS1_(Fuse 24),F52(Fuse 24),FS3(Fuse_14).FS4(Fuse 1A) Reversing contactors Logic board—1 Logie board=2 Interface & Display board (CBF.64 Pin Inter connection connector (Between starter module & control module) ‘Automatic Phase correction board (Optionel) Mode witch 32 Pin control Plug & Socket pee eeeoeaceaoor: ‘Thermal_over load relay (Optional) Motor Plug & Socket @ | Loca! control legend plate © [Power supply boord (® | Dispiey pate (9) | Auxitary contact block (Optional) DISPLAY BOARD LEGEND ‘Symbol Type Description Symbol] Type Description Status | Actuator in open direction Fault | Torque switch open Status | Actuator in Close direction Fault | Torque switch close Status | Limit switch open Fault | Thermoswitch trip Status | Limit switch close Fault | Thermal overload relay trip Status | Actuator in local mode Fault | Fault indication Status | Actuator in remote mode Fault | Single phasing PELL er Status | 11V Internal power supply Status | 23V Internal power supply Soo PRee Le Status | 24V DC For Customer's use q OHO eO sO e-pac 4 O HO he freed, 4 @aq ai, © ae @ g@p ort E it. e-pac module without monitor relay Oy Gg ra | PUSH BUTTON PLATE {WMH INDICATION. LAM © +4 (wew-x) LOCAL CONTROL LEGEND PLATE (view) 4 freed, 4 ‘STARTER MODULE O auma india e-pac O HO eO HO aot? aii Q ce Hy LOCAL CONTROL LEGEND PLATE DISPLAY PLATE special feature) e-pac module with monitor reley(For (Mew) (vIEW-x) DIP SWITCH PARTICULARS: — Switch Switch position Switch position ‘Applicable for No OFF ON Versions 1 retina eer am Local mode tong neing gperaton in Local mode | v1.1 to v1.8 2 = Emergency shut down to Open V1.2, Vit 3 = Emergency shut down to Close V1.2, Vit 4 | Timer board operation enabled | Timer board operation disenabled v5 5 = Inhibit Open direction V6 6 = Inhibit Close direction V6 7 | Inching operation in Remote Non-Inching operation in Remote mode | V1.1 to V 1.2 mode (non self retaining) (self retaining) V5 to V8 8 | Limit switch close bypass Vit to 8 (Closing by torque switch Close) - ‘Auma India e-pac have motor starter and controls built into the actuator. Controls include selector ‘switch (Local-Off-Remote) and local push button OPEN-STOP-CLOSE. Scope of these instruction: — These instructions cover only auma india e~pac. For further instruction for commissioning of actuator refer "Operating instruction SAB~SA100" * Supply voltage & frequency should match with voltage & frequency, which is mentioned in nome plate. * Test run :— selector switch must be in position ‘Loca!’ Operate push button for OPEN (== ) or for CLOSE (-§ ) to run the actuator in required direction, In case of actuator does not run, the status & fault ‘LED's will indicate corresponding fault on the display board. * Connect according to corresponding wiring diagram (SHO _ __ __ ) e-pac Name plate:— The following relevant details are available on the e-poc name plate to ensure our support after supply. DD/MN-008 issue 03/2009 5

You might also like