This mode is used to confirm the activation of the governor actuator.

Note: The 325C, M325C MH, and 330C series does not have a governor actuator.

Table 1

Required Tools
146-4080 Digital Multimeter
188-8589 Test Harness

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/16/2010
320C & 320C L Excavators BPR00001-UP (MACHINE) POWERED BY 3066 Engine(S... Page 7 of 10

Illustration 1 g00778226
Governor Actuator For 312C

(1) Governor actuator

(2) Governor cables

(3) Connector

Illustration 2 g00778227
Governor Actuator For 315C

(1) Governor actuator

(2) Governor cables

(3) Connector

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/16/2010
320C & 320C L Excavators BPR00001-UP (MACHINE) POWERED BY 3066 Engine(S... Page 8 of 10

Illustration 3 g00778702
Governor Actuator For 319C, 320C series and 322C

(1) Governor actuator

(2) Governor cables

(3) Connector

Illustration 4 g00986349
Governor Actuator for 321C

(1) Governor actuator

(2) Governor Cables

1. Stop the engine and disconnect the connector (3) for the governor actuator. Connect the test harness to
the connector.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/16/2010
320C & 320C L Excavators BPR00001-UP (MACHINE) POWERED BY 3066 Engine(S... Page 9 of 10

2. Place the backup switch in the AUT position.

3. Turn the engine start switch to the ON position. Do not start the engine. Select the sweep test for the
governor actuator.

4. Enter the service mode. Perform the device test according to "ENG SWEEP".

Illustration 5 g00690421

5. Use a digital multimeter to measure the frequency of the speed command signal while the system is in
operation. See the above illustration. The duty cycle should be approximately 45% to 90%. A low duty
cycle means a low engine speed. A higher duty cycle means a high engine speed. The pulse width is
narrow at low speeds and the pulse width is wide at high speeds.

6. An abnormality is present when the pulse width is not correct. A failure may exist in the harness, the
governor actuator or the controller.

7. The speed of the engine will vary in synchronization with the reciprocating drive. If the controller is
operating properly, the engine speed will vary between the high idle and the low idle. The governor
actuator may be installed incorrectly or the governor actuator may not be operating correctly, if the
engine speed is not correct. Also, the engine may be operating incorrectly.