Professional Documents
Culture Documents
■ Success with difficult leaf spices like mayoram (oregano) and basil
■ n.d. = not detectable
Steam Sterilization of Spices & Herbs
Steam Pasteurization System
Principles of Ventilex Technology for
Steam Sterilization & Pasteurization:
Steam Decontamination
• High pressure steam is introduced for a specific time period –
typical:
• 20 to 50 seconds – time within 4%
• 107 C to 123 C (224 F to 253 F)
• 1.3 to 3 bar
• Product is conveyed in a thin layer, exposing all surfaces to the
steam
• Hot condensate forms on product- perfect distribution
• Correct temperature and time provides desired kill of pathogens
• Flash cooling down to 55 C (132 F) within 30 seconds
• Product immediately dried and cooled to the desired moisture in
the fluid bed dryer/cooler
Product Time/Temperture Curve
(High Temperature – Short Time)
120
100
Temperature [°C]
80
60
decontamination
40°C
40
30°C
25°C
20 drying cooling
0 1 2 3 4 5 6
Time [Minutes]
Steam Sterilizer / Pasteurizer System
Steam Sterilizer
Video: Plug Flow Example
Steam Sterilizer / Pasteurizer System
High Pressure Rotary Valve (a.k.a. Bokfard )
TM
Sweet paprica
before treatment
1,300,000 400 200 7,000 1,300,000 10,000 95 Not tested
Cut rosemary,
before treatment Not Not
360,000 1,000 20,000 56,000 280,000 0.7
applicable applicable
122°C
252°F
Treatment untreated 35 sec
Aerobic Entero-
Temperature Oil % microorgan bacteria Yeasts Moulds Coliforms
Feature Benefit
HTST Sterilization Technology Highest Quality Product
Continuos Operation High Productivity
Automated Controls Repeatability, Maximum Yield
Proven European Technology No Process Risk
Local Support Uptime
Test Facilities
Laboratory test
installation
In our laboratory, we can simulate processes with varying parameters and thus
determine the best possible product processing.
Product Line Up