You are on page 1of 2

TITAN 250

Gas Turbine Generator Set


Power Generation

General Specifications
• Available Construction Types: • Air Inlet and Exhaust System
Titan™ 250 Gas Turbine
– Duct In/Duct Out – Carbon Steel
• Industrial, Two-Shaft – Totally Enclosed Air-to-Air Cooled – Stainless Steel
• 16 Stage Axial Compressor – Totally Enclosed Water-to-Air Cooled – Coastal Type Filters
– Variable Inlet Guide Vanes • Sleeve Bearings • Enclosure
– Pressure Ratio: 24:1 – Driver Only
– Inlet Airflow: 73.2 kg/sec • Oil Jacking System
– Fire Detection and Suppression
(155.2 lb/sec) • NEMA Class F Insulation
• Turbotronic™ Control System
– Vertically Split Case • Class B Temperature Rise
– Onskid Control System
• Combustion Chamber Annular-Type • Voltages: 1100 to 13,800 VAC - Digital Onskid Display Panel
– 14 Lean-Premixed, Dry Low • Frequency: 50 or 60 Hz – 24 VDC Control Power
Emissions Injectors Package (120 VDC Input)
– Torch Ignitor System – Serial Link Supervisory Interface
• Mechanical Construction
• Gas Generator Turbine – Steel Base Frame with Drip Pans – Field Programmable
– 2-Stage Reaction – Vibration Monitoring
– 316L Stainless Steel Piping <8" dia. – Temperature Monitoring
– Max. Speed: 10,690 rpm
– Compression-Type Tube Fittings – Generator Control
• Power Turbine • Electrical System
– 3-Stage Reaction – Selectable Control Modes
– NEC, Class 1, Group D, Div 2 – Solid-State Voltage Regulation
– Max. Speed: 6500 rpm
– CENELEC/ATEX Zone 2 – Automatic Synchronization
• Bearings – Metering Panel with Manual
– Cable Tray Wiring
– 5 Radial Journal, Tilt-Pad – 120 VDC Battery/Charger System Synchronization*
– 2 Active Thrust, Tilt-Pad – KW Control*
– 2 Inactive Thrust, Fixed Tapered • Direct-Drive AC Start System
– Heat Recovery Application Interface
Land • Fuel System – Multiple Operator Display Screens
• Coatings – Dry Low Emission (SoLoNOx™) – Data Collection and Playback
– Compressor: Inorganic Aluminum – Conventional – Turbine Performance Map*
– Turbine and Nozzle Blades: • Fuel Types – InSight Platform™ Equipment Health
Precious Metal Diffusion Aluminide – Natural Gas or Dual (Gas/Distillate) Management*
• Vibration Transducer Type • Integrated Lube Oil System – Printer/Logger*
– Proximity Probes , 2 per Radial – Turbine-Driven Main Pump • Documentation
Bearing/2 per Thrust Bearing – AC Motor-Driven Pre/Post Pump – Electrical Drawings
– DC (120 V) Motor-Driven – Mechanical Drawings
Main Reduction Drive Backup Pump – Quality Control Data Book
• Epicyclic Type – Oil Cooler and Oil Heater* – Inspection and Test Plan
– 1500 rpm (50 Hz) or 1800 rpm (60 Hz) – Tank Vent Separator and Flame Trap – Test Reports
– Accessory Power Take-Off – Lube Oil Filter – O&M Manuals
Generator • Turbine Compressor Cleaning System • Factory Testing of Turbine
• Salient Pole, 3 Phase, 6 Wire, Wye – On-Crank/On-Line • Factory Testing of Package
Connected, Synchronous, with – Portable Cleaning Tank* – Non-Dynamic
Permanent Magnet Generator Exciter – Dynamic

* Option
TITAN 250
Gas Turbine Generator Set
Power Generation

Performance Available Power


Output Power 23 100 kWe 26 000 10.5
(9950)
Heat Rate 9150 kJ/kWe-hr
(8670 Btu/kWe-hr)
Output Power

HEAT RATE, MJ/kWe-hr (Btu/kWe-hr)


10.0
Exhaust Flow 253 440 kg/hr 23 625
(9480)

OUTPUT POWER, kWe


(558,740 lb/hr)

Exhaust Temp. 460°C


(865°F) 9.5
21 250
(9000)
Application Performance
Steam (Unfired) 35.2 tonnes/hr
(77,600 lb/hr) 9.0
18 875
(8530)
Steam (Fired) 190.5 tonnes/hr Heat Rate
1536°C (2800°F) (420,000 lb/hr)
Chilling (Absorp.) 30 340 kW 8.5
(8620 refrigeration tons) 16 500 (8060)
-30.0 -15.0 0.0 15.0 30.0 45.0
Nominal rating – per ISO
At 15°C (59°F), sea level (-22) (5) (32) (59) (86) (113)
No inlet/exhaust losses INLET AIR TEMPERATURE, °C (°F)
DS250GSPG-002M
Relative humidity 60%
Natural gas fuel with
LHV = 31.5 to 43.3 MJ/Nm3 (940 Btu/scf)
No accessory losses
Engine efficiency: 38.6%
(measured at generator terminals)

Enclosure Access and Maintenance Space*


MINIMUM SPACE CLEARANCE REQUIRED FOR ENCLOSURE
ACCESS DOORS AND ROUTINE OPERATION AND MAINTENANCE

18.2 m 3.7 m
(59’ 6”) (12’ 0”)

3.4 m GENERATOR
(11’ 1”) MAINTENANCE

4.3 m MINIMUM CLEARANCE


(14’ 0”) REQUIRED FOR
ENGINE REMOVAL

Package Height: 3.9 m (12' 9") 13.6 m


(44’ 7”)
Package Weight: 141 150 kg (311,100 lb) DS250PG-003C

*Dry weight, unenclosed height

Solar Turbines Incorporated


P.O. Box 85376
FOR MORE INFORMATION
San Diego, CA 92186-5376 Telephone: (+1) 619-544-5352
Caterpillar is a trademark of Caterpillar Inc. Email: powergen@solarturbines.com
Solar, Titan, SoLoNOx, Insight Platform and Turbotronic are trademarks of Solar Turbines Incorporated. Internet: www.solarturbines.com
Specifications subject to change without notice.
© 2020 Solar Turbines Incorporated. All rights reserved.
DS250PG/0220/EO