You are on page 1of 2

CENTAUR 40

Gas Turbine Generator Set


Oil & Gas Applications

General Specifications
Centaur ® 40 Gas Turbine Generator
• Industrial, Single Shaft • Type: Salient Pole, 3 Phase, 6 Wire, – 120-Vdc Control Battery/Charger
• Axial Compressor Wye Connected, Synchronous, with – Supervisory Communications
– 11 Stage Brushless Exciter Interface
– Variable Inlet Guide Vanes • Construction Options – Turbine Performance Map
– Pressure Ratio: 10.2:1 – Open Drip Proof – Printer/Logger
– Inlet Airflow: 18.7 kg/sec (41.3 lb/ – Weather Protected II (WPII) – Field Programming
sec) – Totally Enclosed Water/Air Cooled • Start System: Direct Drive AC
• Combustion Chamber • Sleeve Bearings • Fuel Systems
– Annular Type • Voltage Regulation – Natural Gas
– Conventional or Lean-Premixed, – Solid-State Regulation with ­– Dual (Gas/Liquid)
Dry,Low Emission (SoLoNOx™) Permanent Magnet Generator – Alternate Fuels
– Fuel Injectors: 10 for Conventional; • NEMA Class F Insulation with B • Integrated Lube Oil System
12 for SoLoNOx Temperature Rise – Turbine-Driven Accessories
– Torch Ignitor System – Oil Tank Vent Separator
• Voltages: 3300 to 13,800 Volt – Oil Tank Vent Flame Trap
• Turbine
– 3 Stage, Reaction • Frequency: 50 or 60 Hz • Lube Oil System Options
– Max. Speed: 14,950 rpm – Oil Cooler
Key Package Features – Oil Heater
• Bearings
• Base Frame with Drip Pans • Axial Compressor Cleaning Systems
– Journal: Tilting Pad
– Thrust: Fixed Tapered Land • 316L Stainless Steel Piping ≤4” dia – On-Crank
• Compressor Coating • Compression-Type Tube Fittings – On-Crank/On-Line
– Stators and Drums: Inorganic • Digital Display Panel – Certified Cleaning Tank
Aluminum • Electrical System Options • Air Inlet and Exhaust System Options
• Turbine Coatings (Optional) – NEC Class I, Group D, Div 2 • Enclosure and Associated Options
– Stage 1 and 2 Nozzles: Diffusion – CENELEC Zone 2 • Factory Testing of Turbine and
Aluminum • Turbotronic™ Microprocessor Control Package
– Stage 1 Blades: Platinum Aluminide System • Documentation
• Velocity Vibration Transducer and – Freestanding Control Console (with – Drawings
RTDs offskid controls) – Quality Control Data Book
Main Reduction Drive – Video Display Unit – Inspection and Test Plan
• Epicyclic Type – Temperature and Vibration – Test Reports
Monitoring – Operation and Maintenance
• 1500 rpm (50 Hz) or
– Historical Displays Instruction Manual
1800 rpm (60 Hz)
• Control System Options
• Acceleration Vibration Transducer
– Auxiliary Control Interface or
Auxiliary Control Console (with
onskid controls)
– Remote Control and Display
CENTAUR 40
Gas Turbine Generator Set
Oil & Gas Applications

Performance Available Power


Output Power 3515 kWe 5000 14.5
(13,750)
Heat Rate 12 910 kJ/kWe-hr
Output Power

HEAT RATE, MJ/kW-hr (Btu/kWe-hr)


(12,240 Btu/kWe-hr) 14.0
4500
(13,270)
Exhaust Flow 68 365 kg/hr

OUTPUT POWER, kWe


(150,715 lb/hr)
13.5
Exhaust Temp. 445°C 4000 (12,320)
(830°F)

13.0
Nominal Rating – per ISO 3500
(12,320)
At 15°C (59°F), at sea level
No inlet/exhaust losses 12.5
3000
Relative humidity 60% (11,850)
Natural gas fuel with Heat Rate
12.0
LHV = 35 MJ/nm3 (940 Btu/scf)
2500 (11,370)
No accessory losses -30.0 -15.0 0.0 15.0 30.0 45.0
Engine efficiency: 27.9% (measured at (-22) (5) (32) (59) (86) (113)
generator terminals)
INLET AIR TEMPERATURE, °C (°F) DS40GSPG-002M

TURBINE
Package Dimensions* DISPLAY
AIR INLET
GENERATOR
PANEL
Length: 9.8 m (32' 3") GAS
TURBINE
Width: 2.6 m (8' 6")
TURBINE
Height: 3.2 m (10' 5") EXHAUST

Typical Weight: 30 460 kg (67,150 lb)

DS40GS-003M

*Dry weight, enclosed height

Solar Turbines Incorporated


P.O. Box 85376 FOR MORE INFORMATION
San Diego, CA 92186-5376 Telephone: (+1) 619-544-5352
Caterpillar is a trademark of Caterpillar Inc.
Solar, Centaur, SoLoNOx and Turbotronic are trademarks of Solar Turbines Incorporated. Email: infocorp@solarturbines.com
Specifications subject to change without notice.
© 2018 Solar Turbines Incorporated. All rights reserved.
Internet: www.solarturbines.com
DS40GS/1118/EO