You are on page 1of 5

To Opt Repair Or Inspection

To Opt Repair Or Inspection

Scale Type:1-9

Final Result
Items Weight
Hack & Repair 0.5783
Patching 0.2549
NDT Inspection 0.1136
Visual Inspection 0.0532

-1-
To Opt Repair Or Inspection

Middle lay NO.1 Weight


Items Weight
Cost 0.8750
Reliability 0.1250

Middle lay NO.2 Weight


Items Weight
Condition Based Repair 0.7292
Condition Monitoring Inspection Task 0.1458
Potential CUF 0.0938
FP Condition During Fire 0.0313

1. To Opt Repair Or Inspection Consistency: 0.0000; Weightiness to "To


Opt Repair Or Inspection":1.0000; λmax: 2.0000
To Opt Repair Or Reliability Cost Wi
Inspection
Reliability 1.0000 0.1429 0.1250
Cost 7.0000 1.0000 0.8750

2. Reliability Consistency: 0.0000; Weightiness to "To Opt Repair Or


Inspection":0.1250; λmax: 2.0000
Reliability FP Condition Potential CUF Wi
During Fire
FP Condition 1.0000 0.3333 0.2500
During Fire
Potential CUF 3.0000 1.0000 0.7500

-2-
To Opt Repair Or Inspection

3. Cost Consistency: 0.0000; Weightiness to "To Opt Repair Or


Inspection":0.8750; λmax: 2.0000
Cost Condition Condition Based Wi
Monitoring Repair
Inspection Task
Condition 1.0000 0.2000 0.1667
Monitoring
Inspection Task
Condition Based 5.0000 1.0000 0.8333
Repair

4. FP Condition During Fire Consistency: 0.0286; Weightiness to "To Opt


Repair Or Inspection":0.0313; λmax: 4.0763
FP Visual Patching NDT Hack & Wi
Condition Inspection Inspection Repair
During Fire
Visual 1.0000 0.2000 0.3333 0.1111 0.0499
Inspection
Patching 5.0000 1.0000 3.0000 0.3333 0.2554
NDT 3.0000 0.3333 1.0000 0.2000 0.1141
Inspection
Hack & 9.0000 3.0000 5.0000 1.0000 0.5806
Repair

-3-
To Opt Repair Or Inspection

5. Potential CUF Consistency: 0.0523; Weightiness to "To Opt Repair Or


Inspection":0.0938; λmax: 4.1397
Potential Visual Patching NDT Hack & Wi
CUF Inspection Inspection Repair
Visual 1.0000 0.1429 0.3333 0.1429 0.0501
Inspection
Patching 7.0000 1.0000 3.0000 0.3333 0.2789
NDT 3.0000 0.3333 1.0000 0.2000 0.1130
Inspection
Hack & 7.0000 3.0000 5.0000 1.0000 0.5581
Repair

6. Condition Monitoring Inspection Task Consistency: 0.0639; Weightiness


to "To Opt Repair Or Inspection":0.1458; λmax: 4.1707
Condition Visual Patching NDT Hack & Wi
Monitoring Inspection Inspection Repair
Inspection
Task
Visual 1.0000 0.2000 0.3333 0.1111 0.0457
Inspection
Patching 5.0000 1.0000 3.0000 0.2000 0.2027
NDT 3.0000 0.3333 1.0000 0.1429 0.0942
Inspection
Hack & 9.0000 5.0000 7.0000 1.0000 0.6574
Repair

-4-
To Opt Repair Or Inspection

7. Condition Based Repair Consistency: 0.0438; Weightiness to "To Opt


Repair Or Inspection":0.7292; λmax: 4.1170
Condition Visual Patching NDT Hack & Wi
Based Inspection Inspection Repair
Repair
Visual 1.0000 0.2000 0.3333 0.1429 0.0553
Inspection
Patching 5.0000 1.0000 3.0000 0.3333 0.2622
NDT 3.0000 0.3333 1.0000 0.2000 0.1175
Inspection
Hack & 7.0000 3.0000 5.0000 1.0000 0.5650
Repair

-5-