Professional Documents
Culture Documents
Product Variants
Variant Name Application Parameter
Polludrone Lite General Purpose PM2.5, PM10, CO2, CO, Noise, Light,
UV-Radiation, Temperature, Humidity
Polludrone Smart Extensive PM2.5, PM10, CO2, CO, SO2, NO, NO2,
O3, Noise, Light, UV-Radiation,
Temperature, Humidity
Polludrone Pro Critical PM1, PM2.5, PM10, TSP, CO2, CO, SO2, NO,
NO2, O3, H2S, Noise, Light, UV-Radiation,
Temperature, Humidity
Patent Pending Technology: Works on innovative Weather Resistant: IP63 grade enclosure for
e-breathing technology for higher data accuracy endurance against harsh weather conditions
Solar Powered: Capable of running independently Tamper Proof: Comes with a security system to
on solar power avoid tampering / malfunction / sabotage
Retrofit Design: Plug and play design for ease of Over-The-Air Update: Automatically upgradeable
implementation from a central server without any onsite visit
Compact: Light-weight and compact system Real-Time Data: Continuous monitoring and
installed at 12-15 feet (4-5 m) height real-time data transfer at configurable intervals
Identity & Configuration: Each equipment carries 3-level Calibration: Can be calibrated by a third
its unique identity with geo-tagging through party nodal agency, reference station co-location
wireless configuration and spot calibration for ultimate precision
Levels of Calibration
General Specifications
Temperature
Humidity Sensor
Size 360mm (H) x 328mm (W) x 200mm (D)
Weight 9.8 Kg
Noise Sensor
Parameters
Measure
Min. Working Working
Measurement Sample Expected
ID Parameter
Parameter Range
Range Resolution
Resolution Min. DetectionErrorDrift
/ Drift ment Sample Expected
Detection Principle Principle Rate Sensor Life
Suspended Particulate Upto
PM2.5 Matters with size less 1000 μg/m3
than 2.5μ &
Upto Light Scattering
1 year
Suspended Particulate 5000 μg/m3
PM10 Matters with size less for &
&
than 10μ Polludrone Pro
0.1 μg/m3 1 μg/m3 Upto ±10 % 1 L /min
Optical Particle
Ultra Fine Particulate 1.5 year
Upto Counter for
PM1 Matters with size less
5000 μg/m3 for Polludrone Pro
than 1μ Polludrone Pro
Total Suspended Upto 30000
PM100
Particulates (TSP) μg/m3
External Modules
(optional) 1 Rain Sensor: 2 Wind Sensor: 3 Flood Sensor:
Tipping Bucket Ultrasonic sensor Ultrasonic sensor
In mm / inch 360º, 0-60 m/s Upto 765 cm
Compliance monitoring
Emergency episode monitoring
Installation:
12-15 ft
Installation Height 12-15 feet (4-5 meters)
height
From
Direction As per maximum direct sunlight exposure the Ground
(if ambient-light monitoring is a preference) level 270°
Open surrounding
Power Availability Constant AC supply within a 5-meter range
from the unit or solar panel
Operation:
When the device is powered on, the device intakes air samples at a predefined frequency through the air
sampling system. Once the air sample is stabilized, the sensory system takes multiple readings during the
sampling time and performs relevant data-processing. During this cycle time, the device flushes out old air sample
and pulls in a fresh one. After each sampling, the data processing system sends the processed data to the central
server using a built-in communication module
Maintenance:
Cleaning: Periodic cleaning is important to ensure optimum device performance. Monthly or quarterly
regular maintenance activity has to be carried out depending upon the surrounding. The activity includes
cleaning the dome for the light sensor, air inlet, and outlet mesh & general cleaning of the exterior.
Sensor Replacement: Every sensor has a limited life span. The sensor life depends on the average pollutant
concentration in the area. The sensors need to be replaced once their performance starts to deteriorate and
the system starts giving unstable data.
Spot-Calibration: The frequency of calibration is decided based on atmospheric conditions and individual
sensor drift to ensure data accuracy. Spot calibration can be performed using reference equipment which
can also be a recently calibrated Oizom device.
Diagnosis/Debugging: Power and network availability are the prime check in case of equipment failure. If the
issue is still unresolved after remote diagnosis, on-site troubleshooting can be planned by an engineer.
®
306, Indraprasth Corporate, Prahladnagar, HB9, Savoie Technolac,
Ahmedabad - India Le Bourget du Lac - France
contact@oizom.com / connect@oizom.com hello@oizom.com
+91-8866660025 / 82 +33 783426695