You are on page 1of 26

MILTON ROY PRODUCTS

POSITIVE DISPLACEMENT PUMPS


POSITIVE DISPLACEMENT PUMPS
WHAT IS A METERING PUMP
FLOW VS PRESSURE
TYPICAL METERING PUMP
APPLICATION
MILTON ROY PRODUCTS
MECHANICAL ACTUATED
DIAPHRAGM
PLUNGER PUMP
PLUNGER PUMP

Type UT
- Liquid end: 316L stainless steel
- plunger: chromium oxide coated
- flushing ring

* Packed plunger UT which


stands for UTEX,has been
launched in october 2006. IT will
last muchlonger, and is including
a flushing ring. This will simplify
laintenance operations.
PLUNGER PUMP

Type N

Liquid end
body Packing
gland
Plunger
Check
valves
Rings braids
HPD DIAPHRAGM DESIGN
Composite diaphragm with integrated o’ring

• Thermoforming confers on the


diaphragm a contour corresponding to
its maximum cubic capacity, thus
avoiding any lengthening of PTFE.
• Can be re used after disassembling.
• Safety: bent naturally in back position,
it avoids the errors of startup.
• Lifetime up to 20 000 h.
METALLIC DIAPHRAGM DESIGN

Type M
Relief valve
Leak detection

Double ball discharge


check valve
Whole Sleeve/Plunger

Liquid end body

Double ball suction check


Admission valve
valve

Double diaphragm body


METALLIC DIAPHRAGM DESIGN

Non return valve

Intermediate
washer

Double
Check Valves
Metal to
Metal sealing
Cold rolled
diaphragms
INOX 316L

Double Diaphragm Body


METALLIC DIAPHRAGM DESIGN

Admission valve function and setting


When the suction phase is operating, whatever
the setting is, for each stroke, the diaphragm is
pushing itself towards the displacement chamber.

Due to loss under pressure, there is always an oil


loss.

Then creating a vacuum of 0.3 bar in the


hydraulic chamber. The non return valve opens in
order to compensate the oil’s loss.

The 0.3 bar value provides an height of liquid


column of 2 mlc elevation.
Admission valve
Admission valve function and setting

When the suction phase is operating,


whatever the setting is, for each stroke, the
diaphragm is pushing itself towards the
displacement chamber.

Due to loss under pressure, there is always


an oil loss.

Then creating a vacuum of 0.3 bar in the


hydraulic chamber. The non return valve
opens in order to compensate the oil’s loss.

Admission valve
The 0.3 bar value provides an height of
liquid column of 2 mlc elevation.
AUTOMATIC STROKE CONTROLLER

STEGMANN electronic Bernard waterproof or


Actuator, single Ph Ex-proof actuator, 3
phases

ECC waterproof or Ex- STI pneumatic actuator


proof actuator, single Ph
MILTON ROY PRODUCTS
RECIPROCATING PUMP
CHARACTERISTIC
MILTON ROY PRODUCTS
MILTON ROY PRODUCTS
MILTON ROY PRODUCTS
MILTON ROY PRODUCTS
TYPICAL SYSTEM & START UP
REQUIREMENT

7.Proceed to the 6.Check visually and by listening.


3.Open the prime valve
displacement chamber (In particular, check that there are no suspicious
degassing (pump with noises).
diaphragm liquid end
5.Fill the housing only).
with the
lubricating oil

8.As soon as the liquid to be


pumped flows out the
priming valve, priming on
4.Check the
the process side has been
pump’s setting
achieved close the priming
which must be
set to 0%.

2.Check the opening of all isolating valves


9.Once the installed on the suction and discharge circuits.
priming is
obtained, adjust
the pump to the
desired capacity

1.Check the pump fixation