You are on page 1of 6

audiostarpro GSI AudioStar Pro ™ PC Enabled/Stand Alone

• Transfer data to connected PC with an E-Record


™ Solution Software

GSI AUDIOSTAR PRO


• Print complete report directly to a compatible ™
CLINICAL TWO-CHANNEL AUDIOMETER USB printer

Special Tests (user defined)


• MLB
Product • Pulsed/FM: Pulsed and Modulated
• Pediatric Noise • Lombard test CLINICAL TWO-CHANNEL AUDIOMETER
Specifications • Pediatric Noise Pulsed • Pure Tone Stenger
• Speech Stenger
Speech – Channels 1 and 2
Dimensions and Weight • Microphone: For live voice testing and
• SAL
• W x D x H: 20.1 inches x 14.6 inches x • Doerfler - Stewart Test
communications
13.2 inches (LCD raised)
• INT/EXT A & INT/EXT B: Can be utilized for Communications and Monitoring
51.0 cm x 37.0 cm x 33.5 cm internal wave files or recorded speech material • Talk Forward: Permits the tester to speak
• Height with LCD lowered – 5.5 inches (14.0 cm) from an external digital device through the examiner microphone into the
• Weight: 17 lb (7.7 kg) Intensity Range: selected transducer.
• Shipping Weight: 27 lb (12.25 kg) • Air Conduction: -10 dB HL to 100 dB HL for • Talk Back: Allows the examiner to listen to
• Power Consumption: 90 Watts TDH 50P (Linear Type 4) comments from the patient in the testing booth.
• Bone Conduction • Monitor: The monitor headset or monitor speaker
Channels  Mastoid: -10 dB HL to 55 dB HL built into the instrument housing may be used
• Two Independent Channels by the examiner to listen to Channel 1, Channel
 Forehead: -10 dB HL to 35 dB HL
2, Aux intercom, and/or Talk Back signals.
Pure Tone – Channels 1 and 2 • Sound Field:* -10 dB HL to 80 dB HL
Fast Efficient Frequency Range: • Paired Inserts:* -10 dB HL to 95 dB HL
• Aux Intercom: The built-in Auxiliary Intercom and
assistant headset allows the examiner to speak
• Air Conduction: 125 Hz to 12,000*** Hz Masking Intensity Range: directly to an Assistant and allows the assistant
Features such as speech auto play, immediate connection to both the Additional features integrated into • Speech Noise: to hear what is being presented to the patient.
• High Frequency:* 8,000 Hz to 20,000 Hz
auto advance and auto frequency display and intuitive control panel while the AudioStar Pro makes testing (8 kHz, 9 kHz, 10 kHz, 11.2 kHz, 12.5 kHz,  Air Conduction: -10 dB HL to 95 dB HL (TDH 50P) • On-Board VRA Control: The built-in VRA controls
being surrounded by new innovative 14 kHz, 16 kHz, 18 kHz*** and 20 kHz***) facilitate fast and simple activation of VRA systems.
selection allow the examiner to every patient even more seamless  Bone Conduction:
• Full Frequency Range:* 125 Hz to 20,000 Hz -10 dB HL to 50 dB HL (mastoid)
improve productivity and patient features. This revolutionary audiometer by configuring pure tone and speech Optional Accessories
• Bone Conduction: 250 Hz to 8,000 Hz -10 dB HL to 35 dB HL (forehead)
flow. Standard features, such as the maintains maximum flexibility in a preferences. The built-in auxillary • Wireless keyboard and mouse
• Sound Field:* 125 Hz to 8,000 Hz  Sound Field: -10 dB HL to 80 dB HL • Gooseneck microphone
headset microphone, allows the two-channel audiometer allowing full intercom, active microphone during • Paired Inserts:* 125 Hz to 8,000 Hz • White Noise:
operator to communicate directly control in testing procedures for every tone presentation as well as remote • Frequency Accuracy: ±1%  Air Conduction: -10 dB HL to 95 dB HL (TDH 50P)
Environmental Requirements
• Total Harmonic Distortion: • Temperature: +15ºC to 40ºC (59 to 104ºF)
with patients while the built-in patient population. testing capabilities provide a multitude  Bone Conduction:
 < 2% (earphones and paired insert phones*) -10 dB HL to 50 dB HL (mastoid) • Relative Humidity: 5% to 90% (non-condensing)
monitor speaker makes it easy for of options for testing difficult to test
 < 5% (bone vibrator) -10 dB HL to 35 dB HL (forehead) • Ambient Pressure Range: 98 kPa to 104 kPa
third parties to participate in the
hearing evaluations. Sound field
Customizable patients. The integrated intelligent
functionality of activating sound field
Intensity Range:**  Sound Field: -10 dB HL to 80 dB HL • Background Sound Level: <35 dB(A)
• Frequency of Use: Once a year to multiple
• Air Conduction (TDH 50P): -10 dB HL to 120 dB HL
Test Type Buttons allow access to Special Tests times per day
options are available from the speakers during hearing aid or • High Frequency:* -20 dB HL to 100 dB HL
• ABLB or Fowler: Tone alternating between • Storage Temperature: -20ºC to + 60ºC (-4ºF to 140ºF)
standard 90 dB HL output to the protocols that are customized to cochlear implant testing improves (with Sennheiser HDA 200 Phones)
Channel 1 and Channel 2: Channel 1 is 400
facility preferences. The AudioStar • Bone Conduction msec ON, 400 msec OFF followed by Channel Quality System
high performance speakers with both efficiency and accuracy.
 Mastoid: -10 dB HL to 75 dB HL 2, 400 msec ON, 400 msec OFF.
96 dB HL - both without any external Pro uses a Configuration Application • Manufactured, designed, developed and marketed
 Forehead: -10 dB HL to 65 dB HL • SISI: An intensity increment is added to a tone under ISO 13485 certified quality systems
software to customize preferences
amplification needed. The maximum
output of 102 dB HL is available with for efficient and consistent testing. Compatible • Sound Field:*
 -10 dB HL to 90 dB HL (basic speakers)
in the selected channel for 200 msec, every 5
seconds. The HL increments are in 1, 2 or 5 dB. Compliance/Regulatory Standards
• High Frequency:* Pure tone testing in the Designed, tested and manufactured to meet
an external amplifier - achieving the Auto Play, Auto Score, and Word The AudioStar Pro addresses the  -10 dB HL to 96 dB HL (high performance
frequency range of 8,000 Hz to 20,000 Hz using the following domestic (USA), Canadian,
List "Favorites" ensure seamless challenges of data management speakers) European and International Standards:
highest output in the industry. Four circum-aural headphones.
 -10 dB HL to 102 dB HL (high performance • ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC
speaker calibration is available for integration of the 50+ commonly such as patient security and HIPAA speakers and external booster amplifier)
• TEN: TEN masking noise will be presented to
the test ear. Pure tone stimuli between 500 Hz 60645-2, ISO 389
advanced sound field testing. One used word lists included with every compliance through our electronic • Paired Inserts:* -10 dB HL to 110 dB HL and 4000 Hz may be used at 1, 2, or 5 dB • UL 60601-1 American Standards for Medical
button, one function incorporated with AudioStar Pro. The integrated Special record solutions: (E-Record Solutions). • Masking Intensity Range increments to obtain TEN thresholds. Electrical Equipment
(Calibrated in effective masking) • QuickSIN: Six (6) sentences with five (5) key
a large display maintains the GSI Tests including Quick-SIN, BKB-SIN These solutions safely and easily • IEC/EN 60601-1 International Standards for
 Narrow Band Noise: words per sentence are presented in four-talker Medical Electrical Equipment
legacy of fast and efficient navigation. and TEN (HL) address research integrate audiometric data into every babble noise. The sentences are presented at
Maximum dB HL is 15 dB below tone • CSA C22.2 # 601-1-M90
trends in hearing evaluation. The facility’s data management system pre-recorded signal-to-noise ratios. The SNR’s
 White Noise: used are 25, 20, 15, 10, 5, and 0. • Medical Device Directive (MDD) to comply with
AudioStar Pro combined with from VA, ENT, Private Practice, Hearing
Familiar Maximum dB HL is 30 dB below tone “EC Directive” 93/42/EEC
GSI Suite, brings a new level of Aid, Cochlear Implant and Pediatric Signal Format:
The AudioStar Pro maintains the user customized reporting options that facilities. • Steady: Tone continuously present.

501C-1 Rev. C
• Pulsed: Tone pulsed 200 msec ON, 200 msec OFF * Optional configuration
friendly interface that has defined GSI addresses the requirements of both
• FM: Modulation Rate: 5 Hz ** The maximum HL values are applicable to the middle frequencies only
since 1949. Audiologists will feel an the facility and referral sources. Modulation Depth: +/- 5% *** Optional configuration

www.grason-stadler.com

For more information, go to www.audiostarpro.com Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344 Setting The Clinical Standard
800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail info@grason-stadler.com
GSI AUDIOSTAR PRO Technical Features

Panel Navigation Direct Print Data Transfer


CLINICAL TWO-CHANNEL AUDIOMETER Gold standard ergonomic design with
familiar one-button, one-function front
Expedite the data entry and test administration.
Use the external keyboard and mouse to enter
Electronic data is transferred with a single button press.

Custom Configuration panel navigation. patient demographics, session comments and


Configurable tests and preferences to improve workflow print a complete report to a connected printer.
and optimize speed of testing.

Tradition of Excellence
The GSI AudioStar Pro™ continues Special Tests
the tradition of excellence in clinical Pre-configured special tests such as QuickSIN, BKB-SIN,
audiometry by maintaining the TEN (HL), ABLB, SISI and Tone Decay addresses the
Grason-Stadler legacy of fast, Stand-Alone/ research trends in hearing evaluation.
efficient, and familiar navigation. PC Enabled
Audiologists appreciate the flexibility
of a stand-alone audiometer that offers
GSI Suite Assistant
seamless data transfer to a computer. GSI Suite captures, saves and Monitor
In the event of a network failure or shares patient information improving Allows direct
computer lock-up, you will not lose reporting to support the needs of the communication
contemporary clinic. GSI Suite is between operator
patient data or the ability to test. The
and assistant
stand-alone configuration is optimized now available as a Noah module for
eliminating
with direct connection to a wireless seamless integration to hearing aid
the need for
VRA Controls
keyboard and mouse making it fast and fittings. an external The built-in VRA controls allow for fast and simple activation
easy to enter patient demographics, intercom system. of VRA systems.
report comments, and expedite test
administration. In addition, direct
connection to a printer and the inte-
grated print button make it possible to Word Lists
print a complete report for immediate Integrated internal digital word lists provide effortless
review with the patient or physician. access to commonly used word lists providing consistent
and reliable recorded speech testing.
The one-button, one-function
front panel of the AudioStar Pro is EMR/EHR Ready
recognized worldwide as the Gold
User login and password controls
Standard of user-friendly design,
provide security for patient data in
GSI Suite Features
allowing audiologists to test with
confidence. AudioStar Pro has every compliance with HIPAA. Complete • Powerful custom report designer
desired feature such as: an extra large audiometric results can be transferred • Select from a variety of provided Two-Channel Control On-Board Navigation
display that reduces eye strain, an to software such as report templates
GSI Suite and Audiologist can mix signals and route them Access integrated word lists
ergonomic housing that maximizes
hand and wrist comfort, and light Noah® 4, or EMR/EHR • Test results in EMR/EHR
compatible format (PDF)
to either one or both ears making hearing
evaluations easier than ever.
and menu selections using
the front panel navigation.
pipes around selected test buttons integrated
with your
Compatible • Retrieve test results for review
allowing concentrated focus on the
patient. facility’s • Print reports from PC compliant
EMR/EHR system. printers
• Network results from multiple
instruments by combining GSI
Suite with OtoAccess™ or Noah 4

Setting The Clinical Standard


GSI AUDIOSTAR PRO Technical Features

Panel Navigation Direct Print Data Transfer


CLINICAL TWO-CHANNEL AUDIOMETER Gold standard ergonomic design with
familiar one-button, one-function front
Expedite the data entry and test administration.
Use the external keyboard and mouse to enter
Electronic data is transferred with a single button press.

Custom Configuration panel navigation. patient demographics, session comments and


Configurable tests and preferences to improve workflow print a complete report to a connected printer.
and optimize speed of testing.

Tradition of Excellence
The GSI AudioStar Pro™ continues Special Tests
the tradition of excellence in clinical Pre-configured special tests such as QuickSIN, BKB-SIN,
audiometry by maintaining the TEN (HL), ABLB, SISI and Tone Decay addresses the
Grason-Stadler legacy of fast, Stand-Alone/ research trends in hearing evaluation.
efficient, and familiar navigation. PC Enabled
Audiologists appreciate the flexibility
of a stand-alone audiometer that offers
GSI Suite Assistant
seamless data transfer to a computer. GSI Suite captures, saves and Monitor
In the event of a network failure or shares patient information improving Allows direct
computer lock-up, you will not lose reporting to support the needs of the communication
contemporary clinic. GSI Suite is between operator
patient data or the ability to test. The
and assistant
stand-alone configuration is optimized now available as a Noah module for
eliminating
with direct connection to a wireless seamless integration to hearing aid
the need for
VRA Controls
keyboard and mouse making it fast and fittings. an external The built-in VRA controls allow for fast and simple activation
easy to enter patient demographics, intercom system. of VRA systems.
report comments, and expedite test
administration. In addition, direct
connection to a printer and the inte-
grated print button make it possible to Word Lists
print a complete report for immediate Integrated internal digital word lists provide effortless
review with the patient or physician. access to commonly used word lists providing consistent
and reliable recorded speech testing.
The one-button, one-function
front panel of the AudioStar Pro is EMR/EHR Ready
recognized worldwide as the Gold
User login and password controls
Standard of user-friendly design,
provide security for patient data in
GSI Suite Features
allowing audiologists to test with
confidence. AudioStar Pro has every compliance with HIPAA. Complete • Powerful custom report designer
desired feature such as: an extra large audiometric results can be transferred • Select from a variety of provided Two-Channel Control On-Board Navigation
display that reduces eye strain, an to software such as report templates
GSI Suite and Audiologist can mix signals and route them Access integrated word lists
ergonomic housing that maximizes
hand and wrist comfort, and light Noah® 4, or EMR/EHR • Test results in EMR/EHR
compatible format (PDF)
to either one or both ears making hearing
evaluations easier than ever.
and menu selections using
the front panel navigation.
pipes around selected test buttons integrated
with your
Compatible • Retrieve test results for review
allowing concentrated focus on the
patient. facility’s • Print reports from PC compliant
EMR/EHR system. printers
• Network results from multiple
instruments by combining GSI
Suite with OtoAccess™ or Noah 4

Setting The Clinical Standard


GSI AUDIOSTAR PRO Technical Features

Panel Navigation Direct Print Data Transfer


CLINICAL TWO-CHANNEL AUDIOMETER Gold standard ergonomic design with
familiar one-button, one-function front
Expedite the data entry and test administration.
Use the external keyboard and mouse to enter
Electronic data is transferred with a single button press.

Custom Configuration panel navigation. patient demographics, session comments and


Configurable tests and preferences to improve workflow print a complete report to a connected printer.
and optimize speed of testing.

Tradition of Excellence
The GSI AudioStar Pro™ continues Special Tests
the tradition of excellence in clinical Pre-configured special tests such as QuickSIN, BKB-SIN,
audiometry by maintaining the TEN (HL), ABLB, SISI and Tone Decay addresses the
Grason-Stadler legacy of fast, Stand-Alone/ research trends in hearing evaluation.
efficient, and familiar navigation. PC Enabled
Audiologists appreciate the flexibility
of a stand-alone audiometer that offers
GSI Suite Assistant
seamless data transfer to a computer. GSI Suite captures, saves and Monitor
In the event of a network failure or shares patient information improving Allows direct
computer lock-up, you will not lose reporting to support the needs of the communication
contemporary clinic. GSI Suite is between operator
patient data or the ability to test. The
and assistant
stand-alone configuration is optimized now available as a Noah module for
eliminating
with direct connection to a wireless seamless integration to hearing aid
the need for
VRA Controls
keyboard and mouse making it fast and fittings. an external The built-in VRA controls allow for fast and simple activation
easy to enter patient demographics, intercom system. of VRA systems.
report comments, and expedite test
administration. In addition, direct
connection to a printer and the inte-
grated print button make it possible to Word Lists
print a complete report for immediate Integrated internal digital word lists provide effortless
review with the patient or physician. access to commonly used word lists providing consistent
and reliable recorded speech testing.
The one-button, one-function
front panel of the AudioStar Pro is EMR/EHR Ready
recognized worldwide as the Gold
User login and password controls
Standard of user-friendly design,
provide security for patient data in
GSI Suite Features
allowing audiologists to test with
confidence. AudioStar Pro has every compliance with HIPAA. Complete • Powerful custom report designer
desired feature such as: an extra large audiometric results can be transferred • Select from a variety of provided Two-Channel Control On-Board Navigation
display that reduces eye strain, an to software such as report templates
GSI Suite and Audiologist can mix signals and route them Access integrated word lists
ergonomic housing that maximizes
hand and wrist comfort, and light Noah® 4, or EMR/EHR • Test results in EMR/EHR
compatible format (PDF)
to either one or both ears making hearing
evaluations easier than ever.
and menu selections using
the front panel navigation.
pipes around selected test buttons integrated
with your
Compatible • Retrieve test results for review
allowing concentrated focus on the
patient. facility’s • Print reports from PC compliant
EMR/EHR system. printers
• Network results from multiple
instruments by combining GSI
Suite with OtoAccess™ or Noah 4

Setting The Clinical Standard


audiostarpro GSI AudioStar Pro ™ PC Enabled/Stand Alone
• Transfer data to connected PC with an E-Record
™ Solution Software

GSI AUDIOSTAR PRO


• Print complete report directly to a compatible ™
CLINICAL TWO-CHANNEL AUDIOMETER USB printer

Special Tests (user defined)


• MLB
Product • Pulsed/FM: Pulsed and Modulated
• Pediatric Noise • Lombard test CLINICAL TWO-CHANNEL AUDIOMETER
Specifications • Pediatric Noise Pulsed • Pure Tone Stenger
• Speech Stenger
Speech – Channels 1 and 2
Dimensions and Weight • Microphone: For live voice testing and
• SAL
• W x D x H: 20.1 inches x 14.6 inches x • Doerfler - Stewart Test
communications
13.2 inches (LCD raised)
• INT/EXT A & INT/EXT B: Can be utilized for Communications and Monitoring
51.0 cm x 37.0 cm x 33.5 cm internal wave files or recorded speech material • Talk Forward: Permits the tester to speak
• Height with LCD lowered – 5.5 inches (14.0 cm) from an external digital device through the examiner microphone into the
• Weight: 17 lb (7.7 kg) Intensity Range: selected transducer.
• Shipping Weight: 27 lb (12.25 kg) • Air Conduction: -10 dB HL to 100 dB HL for • Talk Back: Allows the examiner to listen to
• Power Consumption: 90 Watts TDH 50P (Linear Type 4) comments from the patient in the testing booth.
• Bone Conduction • Monitor: The monitor headset or monitor speaker
Channels  Mastoid: -10 dB HL to 55 dB HL built into the instrument housing may be used
• Two Independent Channels by the examiner to listen to Channel 1, Channel
 Forehead: -10 dB HL to 35 dB HL
2, Aux intercom, and/or Talk Back signals.
Pure Tone – Channels 1 and 2 • Sound Field:* -10 dB HL to 80 dB HL
Fast Efficient Frequency Range: • Paired Inserts:* -10 dB HL to 95 dB HL
• Aux Intercom: The built-in Auxiliary Intercom and
assistant headset allows the examiner to speak
• Air Conduction: 125 Hz to 12,000*** Hz Masking Intensity Range: directly to an Assistant and allows the assistant
Features such as speech auto play, immediate connection to both the Additional features integrated into • Speech Noise: to hear what is being presented to the patient.
• High Frequency:* 8,000 Hz to 20,000 Hz
auto advance and auto frequency display and intuitive control panel while the AudioStar Pro makes testing (8 kHz, 9 kHz, 10 kHz, 11.2 kHz, 12.5 kHz,  Air Conduction: -10 dB HL to 95 dB HL (TDH 50P) • On-Board VRA Control: The built-in VRA controls
being surrounded by new innovative 14 kHz, 16 kHz, 18 kHz*** and 20 kHz***) facilitate fast and simple activation of VRA systems.
selection allow the examiner to every patient even more seamless  Bone Conduction:
• Full Frequency Range:* 125 Hz to 20,000 Hz -10 dB HL to 50 dB HL (mastoid)
improve productivity and patient features. This revolutionary audiometer by configuring pure tone and speech Optional Accessories
• Bone Conduction: 250 Hz to 8,000 Hz -10 dB HL to 35 dB HL (forehead)
flow. Standard features, such as the maintains maximum flexibility in a preferences. The built-in auxillary • Wireless keyboard and mouse
• Sound Field:* 125 Hz to 8,000 Hz  Sound Field: -10 dB HL to 80 dB HL • Gooseneck microphone
headset microphone, allows the two-channel audiometer allowing full intercom, active microphone during • Paired Inserts:* 125 Hz to 8,000 Hz • White Noise:
operator to communicate directly control in testing procedures for every tone presentation as well as remote • Frequency Accuracy: ±1%  Air Conduction: -10 dB HL to 95 dB HL (TDH 50P)
Environmental Requirements
• Total Harmonic Distortion: • Temperature: +15ºC to 40ºC (59 to 104ºF)
with patients while the built-in patient population. testing capabilities provide a multitude  Bone Conduction:
 < 2% (earphones and paired insert phones*) -10 dB HL to 50 dB HL (mastoid) • Relative Humidity: 5% to 90% (non-condensing)
monitor speaker makes it easy for of options for testing difficult to test
 < 5% (bone vibrator) -10 dB HL to 35 dB HL (forehead) • Ambient Pressure Range: 98 kPa to 104 kPa
third parties to participate in the
hearing evaluations. Sound field
Customizable patients. The integrated intelligent
functionality of activating sound field
Intensity Range:**  Sound Field: -10 dB HL to 80 dB HL • Background Sound Level: <35 dB(A)
• Frequency of Use: Once a year to multiple
• Air Conduction (TDH 50P): -10 dB HL to 120 dB HL
Test Type Buttons allow access to Special Tests times per day
options are available from the speakers during hearing aid or • High Frequency:* -20 dB HL to 100 dB HL
• ABLB or Fowler: Tone alternating between • Storage Temperature: -20ºC to + 60ºC (-4ºF to 140ºF)
standard 90 dB HL output to the protocols that are customized to cochlear implant testing improves (with Sennheiser HDA 200 Phones)
Channel 1 and Channel 2: Channel 1 is 400
facility preferences. The AudioStar • Bone Conduction msec ON, 400 msec OFF followed by Channel Quality System
high performance speakers with both efficiency and accuracy.
 Mastoid: -10 dB HL to 75 dB HL 2, 400 msec ON, 400 msec OFF.
96 dB HL - both without any external Pro uses a Configuration Application • Manufactured, designed, developed and marketed
 Forehead: -10 dB HL to 65 dB HL • SISI: An intensity increment is added to a tone under ISO 13485 certified quality systems
software to customize preferences
amplification needed. The maximum
output of 102 dB HL is available with for efficient and consistent testing. Compatible • Sound Field:*
 -10 dB HL to 90 dB HL (basic speakers)
in the selected channel for 200 msec, every 5
seconds. The HL increments are in 1, 2 or 5 dB. Compliance/Regulatory Standards
• High Frequency:* Pure tone testing in the Designed, tested and manufactured to meet
an external amplifier - achieving the Auto Play, Auto Score, and Word The AudioStar Pro addresses the  -10 dB HL to 96 dB HL (high performance
frequency range of 8,000 Hz to 20,000 Hz using the following domestic (USA), Canadian,
List "Favorites" ensure seamless challenges of data management speakers) European and International Standards:
highest output in the industry. Four circum-aural headphones.
 -10 dB HL to 102 dB HL (high performance • ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC
speaker calibration is available for integration of the 50+ commonly such as patient security and HIPAA speakers and external booster amplifier)
• TEN: TEN masking noise will be presented to
the test ear. Pure tone stimuli between 500 Hz 60645-2, ISO 389
advanced sound field testing. One used word lists included with every compliance through our electronic • Paired Inserts:* -10 dB HL to 110 dB HL and 4000 Hz may be used at 1, 2, or 5 dB • UL 60601-1 American Standards for Medical
button, one function incorporated with AudioStar Pro. The integrated Special record solutions: (E-Record Solutions). • Masking Intensity Range increments to obtain TEN thresholds. Electrical Equipment
(Calibrated in effective masking) • QuickSIN: Six (6) sentences with five (5) key
a large display maintains the GSI Tests including Quick-SIN, BKB-SIN These solutions safely and easily • IEC/EN 60601-1 International Standards for
 Narrow Band Noise: words per sentence are presented in four-talker Medical Electrical Equipment
legacy of fast and efficient navigation. and TEN (HL) address research integrate audiometric data into every babble noise. The sentences are presented at
Maximum dB HL is 15 dB below tone • CSA C22.2 # 601-1-M90
trends in hearing evaluation. The facility’s data management system pre-recorded signal-to-noise ratios. The SNR’s
 White Noise: used are 25, 20, 15, 10, 5, and 0. • Medical Device Directive (MDD) to comply with
AudioStar Pro combined with from VA, ENT, Private Practice, Hearing
Familiar Maximum dB HL is 30 dB below tone “EC Directive” 93/42/EEC
GSI Suite, brings a new level of Aid, Cochlear Implant and Pediatric Signal Format:
The AudioStar Pro maintains the user customized reporting options that facilities. • Steady: Tone continuously present.

501C-1 Rev. C
• Pulsed: Tone pulsed 200 msec ON, 200 msec OFF * Optional configuration
friendly interface that has defined GSI addresses the requirements of both
• FM: Modulation Rate: 5 Hz ** The maximum HL values are applicable to the middle frequencies only
since 1949. Audiologists will feel an the facility and referral sources. Modulation Depth: +/- 5% *** Optional configuration

www.grason-stadler.com

For more information, go to www.audiostarpro.com Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344 Setting The Clinical Standard
800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail info@grason-stadler.com
audiostarpro GSI AudioStar Pro ™ PC Enabled/Stand Alone
• Transfer data to connected PC with an E-Record
™ Solution Software

GSI AUDIOSTAR PRO


• Print complete report directly to a compatible ™
CLINICAL TWO-CHANNEL AUDIOMETER USB printer

Special Tests (user defined)


• MLB
Product • Pulsed/FM: Pulsed and Modulated
• Pediatric Noise • Lombard test CLINICAL TWO-CHANNEL AUDIOMETER
Specifications • Pediatric Noise Pulsed • Pure Tone Stenger
• Speech Stenger
Speech – Channels 1 and 2
Dimensions and Weight • Microphone: For live voice testing and
• SAL
• W x D x H: 20.1 inches x 14.6 inches x • Doerfler - Stewart Test
communications
13.2 inches (LCD raised)
• INT/EXT A & INT/EXT B: Can be utilized for Communications and Monitoring
51.0 cm x 37.0 cm x 33.5 cm internal wave files or recorded speech material • Talk Forward: Permits the tester to speak
• Height with LCD lowered – 5.5 inches (14.0 cm) from an external digital device through the examiner microphone into the
• Weight: 17 lb (7.7 kg) Intensity Range: selected transducer.
• Shipping Weight: 27 lb (12.25 kg) • Air Conduction: -10 dB HL to 100 dB HL for • Talk Back: Allows the examiner to listen to
• Power Consumption: 90 Watts TDH 50P (Linear Type 4) comments from the patient in the testing booth.
• Bone Conduction • Monitor: The monitor headset or monitor speaker
Channels  Mastoid: -10 dB HL to 55 dB HL built into the instrument housing may be used
• Two Independent Channels by the examiner to listen to Channel 1, Channel
 Forehead: -10 dB HL to 35 dB HL
2, Aux intercom, and/or Talk Back signals.
Pure Tone – Channels 1 and 2 • Sound Field:* -10 dB HL to 80 dB HL
Fast Efficient Frequency Range: • Paired Inserts:* -10 dB HL to 95 dB HL
• Aux Intercom: The built-in Auxiliary Intercom and
assistant headset allows the examiner to speak
• Air Conduction: 125 Hz to 12,000*** Hz Masking Intensity Range: directly to an Assistant and allows the assistant
Features such as speech auto play, immediate connection to both the Additional features integrated into • Speech Noise: to hear what is being presented to the patient.
• High Frequency:* 8,000 Hz to 20,000 Hz
auto advance and auto frequency display and intuitive control panel while the AudioStar Pro makes testing (8 kHz, 9 kHz, 10 kHz, 11.2 kHz, 12.5 kHz,  Air Conduction: -10 dB HL to 95 dB HL (TDH 50P) • On-Board VRA Control: The built-in VRA controls
being surrounded by new innovative 14 kHz, 16 kHz, 18 kHz*** and 20 kHz***) facilitate fast and simple activation of VRA systems.
selection allow the examiner to every patient even more seamless  Bone Conduction:
• Full Frequency Range:* 125 Hz to 20,000 Hz -10 dB HL to 50 dB HL (mastoid)
improve productivity and patient features. This revolutionary audiometer by configuring pure tone and speech Optional Accessories
• Bone Conduction: 250 Hz to 8,000 Hz -10 dB HL to 35 dB HL (forehead)
flow. Standard features, such as the maintains maximum flexibility in a preferences. The built-in auxillary • Wireless keyboard and mouse
• Sound Field:* 125 Hz to 8,000 Hz  Sound Field: -10 dB HL to 80 dB HL • Gooseneck microphone
headset microphone, allows the two-channel audiometer allowing full intercom, active microphone during • Paired Inserts:* 125 Hz to 8,000 Hz • White Noise:
operator to communicate directly control in testing procedures for every tone presentation as well as remote • Frequency Accuracy: ±1%  Air Conduction: -10 dB HL to 95 dB HL (TDH 50P)
Environmental Requirements
• Total Harmonic Distortion: • Temperature: +15ºC to 40ºC (59 to 104ºF)
with patients while the built-in patient population. testing capabilities provide a multitude  Bone Conduction:
 < 2% (earphones and paired insert phones*) -10 dB HL to 50 dB HL (mastoid) • Relative Humidity: 5% to 90% (non-condensing)
monitor speaker makes it easy for of options for testing difficult to test
 < 5% (bone vibrator) -10 dB HL to 35 dB HL (forehead) • Ambient Pressure Range: 98 kPa to 104 kPa
third parties to participate in the
hearing evaluations. Sound field
Customizable patients. The integrated intelligent
functionality of activating sound field
Intensity Range:**  Sound Field: -10 dB HL to 80 dB HL • Background Sound Level: <35 dB(A)
• Frequency of Use: Once a year to multiple
• Air Conduction (TDH 50P): -10 dB HL to 120 dB HL
Test Type Buttons allow access to Special Tests times per day
options are available from the speakers during hearing aid or • High Frequency:* -20 dB HL to 100 dB HL
• ABLB or Fowler: Tone alternating between • Storage Temperature: -20ºC to + 60ºC (-4ºF to 140ºF)
standard 90 dB HL output to the protocols that are customized to cochlear implant testing improves (with Sennheiser HDA 200 Phones)
Channel 1 and Channel 2: Channel 1 is 400
facility preferences. The AudioStar • Bone Conduction msec ON, 400 msec OFF followed by Channel Quality System
high performance speakers with both efficiency and accuracy.
 Mastoid: -10 dB HL to 75 dB HL 2, 400 msec ON, 400 msec OFF.
96 dB HL - both without any external Pro uses a Configuration Application • Manufactured, designed, developed and marketed
 Forehead: -10 dB HL to 65 dB HL • SISI: An intensity increment is added to a tone under ISO 13485 certified quality systems
software to customize preferences
amplification needed. The maximum
output of 102 dB HL is available with for efficient and consistent testing. Compatible • Sound Field:*
 -10 dB HL to 90 dB HL (basic speakers)
in the selected channel for 200 msec, every 5
seconds. The HL increments are in 1, 2 or 5 dB. Compliance/Regulatory Standards
• High Frequency:* Pure tone testing in the Designed, tested and manufactured to meet
an external amplifier - achieving the Auto Play, Auto Score, and Word The AudioStar Pro addresses the  -10 dB HL to 96 dB HL (high performance
frequency range of 8,000 Hz to 20,000 Hz using the following domestic (USA), Canadian,
List "Favorites" ensure seamless challenges of data management speakers) European and International Standards:
highest output in the industry. Four circum-aural headphones.
 -10 dB HL to 102 dB HL (high performance • ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC
speaker calibration is available for integration of the 50+ commonly such as patient security and HIPAA speakers and external booster amplifier)
• TEN: TEN masking noise will be presented to
the test ear. Pure tone stimuli between 500 Hz 60645-2, ISO 389
advanced sound field testing. One used word lists included with every compliance through our electronic • Paired Inserts:* -10 dB HL to 110 dB HL and 4000 Hz may be used at 1, 2, or 5 dB • UL 60601-1 American Standards for Medical
button, one function incorporated with AudioStar Pro. The integrated Special record solutions: (E-Record Solutions). • Masking Intensity Range increments to obtain TEN thresholds. Electrical Equipment
(Calibrated in effective masking) • QuickSIN: Six (6) sentences with five (5) key
a large display maintains the GSI Tests including Quick-SIN, BKB-SIN These solutions safely and easily • IEC/EN 60601-1 International Standards for
 Narrow Band Noise: words per sentence are presented in four-talker Medical Electrical Equipment
legacy of fast and efficient navigation. and TEN (HL) address research integrate audiometric data into every babble noise. The sentences are presented at
Maximum dB HL is 15 dB below tone • CSA C22.2 # 601-1-M90
trends in hearing evaluation. The facility’s data management system pre-recorded signal-to-noise ratios. The SNR’s
 White Noise: used are 25, 20, 15, 10, 5, and 0. • Medical Device Directive (MDD) to comply with
AudioStar Pro combined with from VA, ENT, Private Practice, Hearing
Familiar Maximum dB HL is 30 dB below tone “EC Directive” 93/42/EEC
• BKB-SIN: Contains 18 List Paris. The sentences
GSI Suite, brings a new level of Aid, Cochlear Implant and Pediatric Signal Format: are presented at prerecorded signal-to-noise
• Steady: Tone continuously present. ratios that decrease in 3-dB steps. Each list in
The AudioStar Pro maintains the user customized reporting options that facilities. * Optional configuration
the pair is individually scored, and the results of

501C-1 Rev. C
• Pulsed: Tone pulsed 200 msec ON, 200 msec OFF
friendly interface that has defined GSI addresses the requirements of both the two lists are averages to obtain the List Pair ** The maximum HL values are applicable to
• FM: Modulation Rate: 5 Hz score. Results are compared to normative data the middle frequencies only
since 1949. Audiologists will feel an the facility and referral sources. Modulation Depth: +/- 5% to obtain the SNR Loss. *** Optional configuration

www.grason-stadler.com

For more information, go to www.audiostarpro.com Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344 Setting The Clinical Standard
800-700-2282 • 952-278-4402 • fax 952-278-4401 • e-mail info@grason-stadler.com