Professional Documents
Culture Documents
ComFlex AM DS 0-0-3
ComFlex AM DS 0-0-3
ComFlexAM
Features
Low PIM to BTS (≤ -160dBc).
ACU Cascade supported to share the monitoring.
Max. DL input power of 100W per RFU of ACU.
Modularized ACU and Remote Unit support field upgrade and
independent gain control.
ACU supports 8 operators duplexinput.
Full operation bandwidth system supports multi-operator application.
Supports all major technologies GSM, CDMA, WCDMA and LTE.
Web based GUI for intelligent commissioning and configuration.
Supports OCU extension
Remote Unit supports PSU/PA/optical backup (conditional) and black optional.
Product Description
The ComFlex series Distributed Antenna System is an RF over fibresolution that enhances a wireless network’s
coverage by extending cellular services from existing cell sites to an indoor environment. The system consists of
the Active Conditioning Unit (ACU), Optical control Unit (OCU), Combiner and Remote Unit (RU). The ACU
includes the Chassis, Power Supply Unit (PSU)and RF Unit (RFU). With a modular design, it can support up to 8
independent RF inputs and 8 Remote Units. The Remote Unit is designed with a compact form factor for easy
installation, and itsmodular design is easy for upgrading and maintenance, supports up to 8 bands including MIMO
frequency.
This solution is an effective point-to-multipoint distributed antenna system that provides effective coverage
enhancement. The Comba DAS offers service providers an optimal solution for multiple applications from a single
building to a campus, mega mall, or sports arena and beyond.
Electrical
700MHz 700APAC 800MHz 850MHz 900MHz 1800MHz
698-716/
Uplink Frequency Range 703-748 806-824 824-849 880-915 1710-1785
776-787
MHz
Downlink Frequency 728-746/
758-803 851-869 869-894 925-960 1805-1880
Range 746-757
Operating Bandwidth MHz 18/11 45 18 25 35 75
Downlink Output Power dBm 43 43 43 43 43 43
Uplink Maximum gain dB -3 -3 -3 -3 -3 -3
DownlinkMaximum gain
dB -3 -3 -3 -3 -3 -3
(@ 46dBm input)
ATT Adjustable Range
dB ACU: 0-70, RU: 0-30
(1dB step)
Pass Band Ripple (p-p) dB ≤5 ≤6 ≤5 ≤5 ≤5 ≤6
3GPP TS
3GPP TS 3GPP TS 3GPP TS 3GPP TS 3GPP TS 25.106
Spurious emission
36.106 36.106 36.106 25.106 36.106 3GPP TS
36.106
Uplink Noise Figure at
dB ≤5 ≤5 ≤5 ≤5 ≤5 ≤5
Maximum Gain
System Delay sec ≤2
VSWR ≤ 1.5
Max.Downlink Input Power
dBm 50
per RFU of ACU
Specifications
Mechanical---ACU
Dimensions, H x W x D mm 220 x 482.5 x 450
Rack 15.5
Per RFU 4.5 (max. support 8 RF units)
Weight (approx.) kg
PSU 2
MCU 1.5
VAC 100-240/50-60Hz
Power Supply
VDC -48/47-63Hz
Power Consumption (approx.) W 180 (with 8 RFUs)
RF Connectors Input: Din, duplex; Output:QMA, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Fan
Installation Type 19” Rack
Mechanical---Combiner
Dimensions, H x W x D mm 44 x 485x 450
Weight (approx.) kg 6.5
RF Connectors QMA-Female, simplex
o
Operating Temperature C 0 to +45
Operating Humidity ≤ 85%
Ingress Protection IP30
Enclosure Cooling Convection
Installation Type 19” Rack
Mechanical---RU
CMU 528 x 251 x 298
Dimensions, H x W x D Per RF Unit mm 528 x 152 x 290(max. support 4 RF units)
Mounting Rack 602 x 820 x 30
CMU 30
Weight (approx.) PerRF Unit kg 20 (max. support 4 RF units)
Mounting Rack 8
Power Supply VAC 100-240/50-60Hz
Power Consumption (approx.) W 150 Per band (max. 1200)
RF Connectors N-Female, duplex
Fiber Connectors FC/APC
o
Operating Temperature C -40 to +55
Operating Humidity ≤ 95%
Ingress protection IP65