Professional Documents
Culture Documents
FS-N40 Series
Looks different
Difference is not just looks
FS - N40 Series
The reason why Fiberoptic Sensor has been chosen is
“Small Fiber Unit” & “Highly Accurate Amplifier”
And
What makes Fiberoptic Sensor is so superior is
“Certainty” & “Simplicity”
NEW
2
Reliable Detection under Any Conditions
3
Highest Ever TERA Power
TERA Switch
Go from standard to
high power with
the flick of a switch
NEO
The newly developed NEO Parabolic LED and control algorithm Parabolic
give 7.5 times the light exposure of conventional models. And the LED ×220
Existing
TERA switch gives you 220 times more, high power with the flick standard* ×7.5
of a switch.
*FS-N10 Series FINE Mode
4
Equipped with New LED Module - “NEO Parabolic LED”
Light intensity is significantly increased using the latest high brightness LED and efficient circuit design. Also, the
parabolic mirror formed by the paraboloid surface transmits light emitted by the LED directly to the front fibre unit.
Parabolic
Greater
mirror combined
efficiency
High Greater
brightness light
LED intensity
Most light not transmitted Some light not transmitted All light concentrated
Ambient
light
5
NEW CONCEPT
6
Read, Understand, Act
■ English ■ Japanese
■ Chinese ■ German
7
Visual Innovation: Fibre Unit Indicator
Active Receiver
A miniature green LED is placed in front of the amplifier
Optical Filter
receiver's light receiving element. The green light
Green
comes on with the sensor, allowing users to see the LED
status just by looking at the front of the Fibre Unit. An
optical filter positioned between the light receiving
ACT-R Button
element and the green LED ensures that light from the
green LED does not affect the light receiving element.
Light Receiving Element
8
Multi-Functional Active Receiver
Configuration
Adjustment
Amplifier Pairing
9
NEW CONCEPT
Multi-Output Unit
Total Costs Reduced
Multi-Output Unit
FS-MC8N/P
Power supply
cables
Space-saving
10
Reduced Cables
The Multi-Output Unit has just one power supply/output cable coming from the amplifier, providing a clean cable
layout. Replacing or adding sensors is easy as there's no need to wrangle cables again.
Conventional
Unit
Terminal block
Multi-Output
Unit
Terminal block
ON Multi-output unit
OFF common output
11
Choice of Expansion and Simplified Wiring for Multiple Units
The Ultimate Range of Options
Network compatibility
Network
Communication
Unit
Multi-Output Unit
Multi-Output Unit
FS-MC8N/P
ing
d wir
p lifie
Sim
Normal expansion
Main Unit +
Expansion Units
Expansion connector
Just one cable
for each
expansion unit
12
Compatible with a range of open networks
*EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
13
Versatile Functionality Provides Ease of Use in Various Scenarios
Easy Operation and Proper Light Intensity Built-in Highly Visible Indicator
Easy to switch to optimum light intensity if saturation The highly visible indicator, with an area 8.7 times larger
occurs when detecting transparent or very small than conventional models, makes it easy to see ON/OFF
workpieces. status even at a distance.
Incoming light is set to 100.0% when configuring Even when exposed to dirt or dust, the sensor detects
sensitivity settings, allowing intuitive understanding of the fall in received light and automatically returns to its
light attenuation when errors occur. previous state.
Minimises increases in amplifier temperature, reducing Use IO-Link to transmit all kinds of data, such as control
stress on internal parts such as the LED. Also minimises signals and values. *M8 connector type only
variation in values.
14
Lineup
Amplifier Units
Main Expansion
unit unit
Cable type M8 Connector type
Expansion
FS-N42N FS-N42P
unit
2-Output 2 1
Type Model Control output
Expansion
FS-N44N FS-N44P
unit Expansion
FS-N40 None*
unit
*Counted as 1 output if expanded with Multi-Output Unit FS-MC8N/P or the NU Series
communication unit.
Multi-Output Unit
Description Model
Amplifier securing bracket
(for main unit)
Allows attachment without a DIN rail.
OP-88245
Also allows attachment from above, or from the side as OP-88245
shown in the illustration to the right.
End unit*1
(when using expansion units)
Insert the amplifier to secure it when adding main and
expansion units. Always use when adding units. OP-26751 OP-26751
(Pack of 2)
(Pack of 2)
M8 connector cable
2 m/10 m 2 m type
OP-73864
Used to connect to the FS-N41C. The amplifier does not
come with a connector cable, so purchase it with this
option.
10 m type
OP-73865
15
Active Receiver
The indicator allows operational status to be checked
without looking at the amplifier.
Thrubeam
Model
P19
Reflective
Model
P19
Oil/Chemical Resistance
The fluorocarbon resin coating allows these fibre units to
be used in almost any environment, including oil- or
chemical-splash conditions.
Thrubeam
Model
P23
Fibre Unit (FU Series)
Reflective
Model
P32
Choose from over 170 Types of Fibre Unit.
Focused Beam/High-power
Focused beam with aperture angle of 6°. Not susceptible to
interference from stray light, captures workpieces reliably.
Can detect workpieces at a distance.
Thrubeam
Model
P21
Reflective
Model
P28
Wide Range
Useful when the workpiece does not pass a fixed point,
for example when detecting falls or drops.
Thrubeam
Model
P24
Reflective
Model
P33
16
Integrated Bracket Threaded and Hex-shaped Fibres Sleeve
The sensor is integrated into an L-shaped Threaded for easy mounting onto brackets The fibre tip is a thin sleeve.
bracket, which simplifies installation. and machine equipment. Eliminate problems caused by limited
mounting space. Lineup includes side-
view and bendable sleeve types.
Thrubeam Thrubeam Thrubeam
Model Model Model
P23
Retro-
Reflective Reflective Reflective
Model Model Model
Thrubeam
Model
P24
Reflective Thrubeam Thrubeam
Model Model Model
17
Model Page Model Page Model Page
18
Thrubeam
16.9
14.4
2 m Free-cut
3600 3100 880 FU-R77TZ
R2
(ø2.2) 2100 320 Approx.
M4 ToughFlex 640
−40 to +60˚C 1300 190 25g
Hex-shaped
17.5
1800 1800 880 FU-R77TG
15 1 m cut not allowed. R10
1800 320 Approx.
M4 −40 to +60˚C Stainless Steel 640 1300 190 43g
Transmission:
2 m Free-cut
3600 3600 1300 ø1 FU-R77
R2
M4 M4 (Ø2.2) 3000 430 Approx.
16.5 ToughFlex 880
−40 to +60˚C 1800 240 Reception: 21g
14 ø3.2
2 m Free-cut
3600 3600 1500 FU-R7F
Threaded M4 17.5 (Ø2.2) R25 3200 540 Approx.
−40 to +60˚C 1100 2200 290 21g
15
*1 W
hen using the FS-N40 Series. “3600 mm (1800 mm)” is assumed as maximum because the fibre cable has a length of 2 m (1 m).
Reflective
16.8
2 m Free-cut
790 710 310 FU-R67TZ
R2
(Ø2.2 × 2) 550 90 Approx.
ToughFlex 210
M6 −40 to +60˚C 470 56 25g
Hex-shaped
18
790 710 310 FU-R67TG
1 m cut not allowed. R10
550 90 Approx.
−40 to +60˚C Stainless Steel 210 470 56
M6 32g
17 2 m Free-cut
1150 1100 410 FU-R6F
Threaded (Ø2.2 × 2) R25 860 140 Approx.
300 570 67
M6 −40 to +60˚C 21g
19
Thrubeam
FU-77V
R0.5
Approx.
ToughFlex
2 m Free-cut 3600 3600 1400 25g
M4 M4 (ø2.2) 3000 430
14 1100
−40 to +50˚C 1900 280 FU-77
R2
ø1.13 Approx.
ToughFlex
Lens attachment P25 21g
*1 W
hen using the FS-N40 Series. “3600 mm (1800 mm)” is assumed as maximum because the fibre cable has a length of 2 m (1 m).
Integrated Bracket
12.2 FU-L51Z
10
Approx.
mm
12.2 17 30g
2-ø3.4
17
3600 2900 1000 FU-L52Z
15
Top 2200 290 ø1.13 Approx.
mm 790
12.2 17 1300 170 30g
2-ø3.4
22
2 m Free-cut FU-L53Z
20 R2
(ø2.2) Approx.
mm ToughFlex
12.2 17 −40 to +50˚C 30g
2-ø3.4
13 FU-L50Z
3600 3600 3600
Top 10
3600 2100 ø3.5 Approx.
(Built-in lens) mm 14 20 3600 3600 1100 30g
2-ø3.4
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
20
Cylinder (Set Screw Installation)
ø1.5
1 m Free-cut R2 700 220 FU-59U
10 800
(ø1.0) ToughFlex 510 64 ø0.5 Approx.
−40 to +50˚C High-flex 170 360 40 4g
ø1.5
ø1.5
1 m Free-cut 1200 440 FU-59
R4 1500
10 (ø1.0) 900 130 ø0.7 Approx.
High-flex 350
−40 to +70˚C 600 77 3g
ø2.5
50 cm cut not FU-55
10 allowed. Approx.
−40 to +70˚C 3g
73 55 21
ø2.5 R10 41 5 ø0.125
Do not bend ø2.5 16 27 2
sleeve. ø0.3 50 cm cut not FU-56
10 allowed. Approx.
5 −40 to +70˚C 3g
ø3
2 m Free-cut 3600 1400 FU-5FZ
R2 3600
14 (ø2.2) 3000 430 ø1.13 Approx.
ToughFlex 1100
−40 to +50˚C 1900 280 19g
ø3
ø3
2 m Free-cut 3600 3600 1900 FU-5F
15 (ø2.2) R25 3600 540 ø1 Approx.
−40 to +70˚C 1500 2600 310 19g
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
21
Thrubeam
10
2-ø2.1 1 m Free-cut 810 270 FU-51TZ
950
(ø1.0) 570 90 ø0.5 Approx.
10 220 370 50
−40 to +50˚C 5g
Thickness: 3
Top
14
2-ø3.2 2 m Free-cut FU-52TZ
3600 3600 1400
(ø1.3) 3100 420 ø1 Approx.
14 1100 1900 250
−40 to +50˚C 15g
Thickness: 3.5
10.5 1 m Free-cut
950 810 270 FU-57TZ
Side 2-ø2.1 (ø1.0) 570 90 Approx.
6 220 370 50
−40 to +50˚C 5g
Thickness: 2.5
R2
ø0.5
ToughFlex
7
13 2-ø2.1
1 m Free-cut
740 570 220 FU-53TZ
(ø1.0) 400 86 Approx.
170 300 39
−40 to +50˚C 10g
Thickness: 2
7
15
2 m Free-cut
3600 3600 1300 FU-54TZ
2-M3
Flat (ø2.2) 2700 400 ø1 Approx.
1100 1800 240
−40 to +50˚C 25g
Thickness: 4
12
8.5
2 m Free-cut 3200 1100 FU-56TZ
3600
(ø2.2) 2500 400 ø1.13 Approx.
−40 to +50˚C 750 1500 240 20g
2-ø2.2
Thickness: 3.5
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
Sleeve
M4 ø1
Psleeve R10 mm
ø1.65 15 2 m Free-cut
3600 3600 1800 FU-73
(ø2.2) 3600 540 Approx.
67 −40 to +70˚C 1400 2400 330 24g
Top
Psleeve R10 mm ø3
ø0.4 15
1 m Free-cut
390 370 120 FU-76F
(ø1.0) R10 260 40 ø0.265 Approx.
45 −40 to +70˚C 85 180 20 10g
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
22
Oil/Chemical Resistant
2 m Free-cut
3600 3600 3600 FU-92
(ø2.2) 3600 2400 ø3.7 Approx.
22 3600
−40 to +70˚C 3600 1500 71g
ø5
Top
2 m Free-cut
3600 3600 3600 FU-98
36.5 (ø2.2) R40 3600 3600 ø6 Approx.
3600 3600 1900
ø6.5 −40 to +70˚C 70g
2 m Free-cut
3600 3600 3100 FU-96
(ø2.2) 3600 860 ø2.8 Approx.
ø5 2000 3600 570
−40 to +70˚C 71g
23
Side
2 m Free-cut
3600 3600 3600 FU-96T
13
(ø2.2) R25*2 3600 3600 ø3.7 Approx.
3600 3600 2400
Thickness: 7 0 to +60˚C 35g
14.3
M4
14.6 2 m Free-cut
3600 3600 2500 FU-80TZ
(ø2.2) 3600 1000 ø2.3 Approx.
2000 3500 790
−20 to +100˚C 30g
Side R2
(oil resistant) M8 ToughFlex
17 2 m Free-cut
3600 3600 3600 FU-80MTZ
(ø2.2) 3600 3600 ø4.3 Approx.
3600 3600 2900
−20 to +100˚C 55g
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
*2 Fibre cannot be bent within 25 mm from end of case screw cap.
High-flex
ø1 1 m Free-cut FU-58U
ø1.0 6 (ø1.0) Approx.
−40 to +50˚C 4g
ø1.5
1 m Free-cut
800 700 220 FU-59U
ø1.5 10 (ø1.0) 510 64 ø0.5 Approx.
170 360 40
−40 to +50˚C 4g
R2
ToughFlex
M3 High-flex
1 m Free-cut FU-79U
M3 10 (ø1.0) Approx.
−40 to +50˚C 4g
M4
1 m Free-cut
1800 1800 1400 FU-70U
13
(ø1.0) 1800 420 ø2.3 Approx.
1200 1800 240
−40 to +50˚C 5g
M4
Built-in lens M4
14.4
2 m Free-cut R1
3600 3600 1400 FU-70TU
(ø1.0) ToughFlex 3500 410 ø2.3 Approx.
1200 2100 210
−20 to +50˚C High-flex 8g
ø1.5
1 m Free-cut FU-59
ø1.5 10 (ø1.0) Approx.
−40 to +70˚C 3g
1200 440
1500
900 130
350 600 77
1 m Free-cut FU-79
R4
M3 10 (ø1.0) ø0.7 Approx.
High-flex
−40 to +70˚C 6g
M3
1 m Free-cut
1000 820 300 FU-57TE
6 x 10.5 x 2.5 (ø1.0) 610 90 Approx.
200 410 58
−40 to +70˚C 5g
6 10.5
*1 W
hen using the FS-N40 Series. “3600 mm (1800 mm)” is assumed as maximum because the fibre cable has a length of 2 m (1 m).
23
Thrubeam
Heat Resistant
2 m Free-cut
3600 3200 860 FU-86H
150˚C *4 (ø2.2) R20 2100 400 Approx.
17 620 1300 230
−40 to +150˚C 35g
M4
ø1.5
FU-88K
2m cut not allowed.
200˚C 10 R8 Approx.
15 −40 to +200˚C
30g
M4 2100 810
2900
1500 300 ø1
460 1100 170
FU-84C
10 2m cut not allowed.
300˚C R25 Approx.
15 −40 to +300˚C
66g
M4 Lens attachment P25
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
*2 Use the fibre sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fibre unit.
*3 The recommended maximum ambient temperature during operation is 90°C when constantly using a fibre unit in a high-temperature environment.
*4 The recommended maximum ambient temperature during operation is 130°C when constantly using a fibre unit in a high-temperature environment.
*5 The recommended maximum ambient temperature during operation is 150°C when constantly using a fibre unit in a high-temperature environment.
Wide-range
Thickness: 5 60 2 m Free-cut
3600 3600 1500 FU-A40
(not including the
40 mm 17 3200 610 Approx. 40 × 0.25 Approx.
50 mm spiral section) 1100 2100 350 70g
–20 to +50˚C
R10
Thickness: 5 120 2 m Free-cut
3600 1400 FU-A100
17 (not including the 3600
100 mm 3200 540 Approx. 100 × 0.25 Approx.
50 mm spiral section) 1000 2000 310 110g
–20 to +50˚C
20
2 m Free-cut
3600 3600 2800 FU-12
20 10 × 3
10 mm (ø2.2) 3600 1000 Approx.
2500 (With 1.0 mm wide slit)
−40 to +50˚C 3600 580 23g
Thickness: 4.2
29.8
2 m Free-cut
3600 3600 3600 11 × 2 FU-E11
10.5 R2
Area 11 mm (ø2.2) 3600 2200 (With 0.5 mm / 1.0 mm Approx.
ToughFlex 3600 3600 1200
−40 to +50˚C wide slit) 20g
Thickness: 4.0
69
40 × 3
2 m Free-cut 3600 3600 3600 FU-E40
19.5 (0.5 × 20 mm /
40 mm (ø2.2) 3600 3600 3600 Approx.
0.5 × 30 mm
−40 to +50˚C 3600 3600 30g
Slit attachment P25 slit options available)
Thickness: 5.1
*1 When using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable has a length of 2 m.
*2 R10 for the first 10 mm of cable from the housing.
24
Detecting Distance Using Thrubeam Lenses
FU-77TZ/
3600 2700 1700
Tip: ø4.3 77V/77
Ultra-long
detecting
FU-7F 3600 3200 2000
distance F-4
−40 to +70˚C Approx.
Aperture 9.5 1g
Angle: FU-78 3600 2500 1400
Approx. 8°
FU-77TZ/77V/
3600 2100 1100
77/84C/88K
Tip: ø4
FU-7F/86A 3600 2500 1400
Long-detecting
distance
F-2
−40 to +300˚C Approx. FU-86Z 3600 1900 1000
Aperture
7.9 2g
Angle:
Approx. 15°
FU-78 3600 1600 900
Fixing Nut
F-5
Side-view with
−40 to +105˚C Approx. FU-86Z 3600 2900 1800
mounting holes
5.6 10g
9.3
16.7
FU-78 3600 2300 1300
Tip: ø4
FU-77G 1800 1600 530 300
F-1
Side-view −40 to +70˚C*2 Approx. FU-7F/86A 3600 2700 2300 630 370
9.5 2g
* 1 The maximum sensing distance of 3600 mm (1800 mm) is possible because the fibre length on one side is 2 m (1 m).
*2 When using the F-1 at a temperature of 70°C or more, specify the “Heat-resistant F-1”.
Slit Shape With OP-84365 attached With OP-84366 attached OP-84365 OP-84366
Optical Axis Size 30 × 0.5 mm 20 × 0.5 mm
TERA 3600 3600
MEGA 3600 3600
ULTRA 3500 2300
Detecting distance for
SUPER 1500 930
each power mode
TURBO 760 510
(mm)*1
FINE 460 330
HSPD 160 110
S-HSPD 80 56
Slit weight (transmitter/receiver set) Approx. 4g
*1 W
hen using the FS-N40 Series. “3600 mm” is assumed as maximum because the fibre cable
has a length of 2 m.
25
Reflective
26
Cylinder (Set Screw Installation)
15 250 91 FU-49X
1 m cut not allowed. R4 280
170 25 Approx.
ø1.5 −40 to +70˚C High-flex 59 130 14 3g
ø1.5
Sleeve section 15
cannot be 46 14 FU-46
3 1 m cut not allowed. 64
bent ø1.5 R10 30 3 Approx.
−40 to +70˚C 8
ø0.5 22 1 2g
Sleeve section 14
cannot be 160 120 54 FU-22X
bent 6 50 cm cut not allowed.
ø2.5 ø2.5 R25 100 20 Approx.
−40 to +70˚C 42
ø1.77 76 11 4g
17 FU-23X
850 830 540
50 cm cut not allowed.
R25 730 220 Approx.
ø3 −40 to +70˚C 330 660 180 4g
Sleeve section 15
cannot be 120 100 46 FU-45X
5 50 cm cut not allowed.
bent R4 83 11 Approx.
ø3 −40 to +70˚C 33
ø0.82 68 6 4g
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
Integrated Bracket
Type Detecting distance (mm)*1
Fibre unit length Minimum
Appearance Other power modes Model
Optical (Diameter) bend radius
Beam emitting (mm) TERA (Longest) Weight
axis Ambient ntemperature (mm) MEGA TURBO
direction FINE (Initial) ULTRA HSPD
height
SUPER S-HSPD
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
27
Reflective
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
Approx.
R10 FU-24X
ø0.1
Approx.
R25 FU-21X
ø0.2
R2
FU-35FZ
ToughFlex
Tip: ø4.3
Approx.
R25 FU-35FA
ø0.4
R2
FU-35TZ
ToughFlex
R10
FU-35TG
Stainless Steel
R2
FU-35FZ
ToughFlex
R10
Small Spot FU-35FG
Stainless Steel
Tip: ø7.4
R10
FU-35TG
Stainless Steel
R25 FU-35FA
Approx.
R25 FU-21X
ø1.0
R2
FU-35FZ
Tip: ø10.6 ToughFlex
R25 FU-35FA
28
Lens Attachment (Parallel Beam) + Fiber Unit
R2
FU-35FZ
ToughFlex
76 76 68
76 32
66
R10 76 25
Tip: ø4.3 Stainless FU-35FG
Steel
Approx. ø4
100 100
(within the 9.5 −30 to +70˚C 100
Parallel Beam Spot F-3HA R25 FU-35FA 100 76
detecting of Approx. 2g 95 100 70
0 to 20 mm)
R2
FU-35TZ
ToughFlex
68 54
68
68 39
R10 50
68 30
Stainless FU-35TG
Steel
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
R25 FU-35FA
3 25
In
In
M6 2 m Free-cut FU-10 2.5
Adjustable 20
ø0.9 to 3.5 10 to 30 (ø1.3 × 2) Approx. R25 2
beam spot 15
−40 to +70˚C 5g 1.5
26.4∼31.5 Adjustable 10
1
range
0.5 5
0 0
0 10 20 30 40 0.5
Distance (mm) Beam
Tip: ø3 FU-20
Approx. 50 cm cut not allowed.
Small Spot 5 Approx. R25
ø0.1 −40 to +70˚C
2g
18
29
Reflective
Definite-reflective
Type Detecting distance (mm)*1
Fibre unit length Minimum Beam spot
Appearance Other power modes Model
Beam emitting (Diameter) bend radius TERA (Longest) diameter
(mm) MEGA TURBO Weight
direction Ambient ntemperature (mm) FINE (Initial) (mm)
ULTRA HSPD
SUPER S-HSPD
20.5
Thickness: 3.6 2 m Free-cut
0 to 25 0 to 25 0 to 25 FU-38S
(ø2.2 × 2) R5 0 to 25 0 to 25 — Approx.
29 0 to 25 0 to 25 0 to 25
−40 to +70˚C 20g
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
Thickness: 2
1 m Free-cut
2 to 180 2 to 150 2 to 52 FU-41TZ
R2
2-ø2.1 (ø1.0 × 2) 2 to 110 2 to 13 Approx.
13 ToughFlex 2 to 42 2 to 74 2 to 4
−40 to +50˚C 5g
7
Thickness: 4
2 m Free-cut 1 to 820 1 to 220 FU-42TZ
1 to 1000
Flat 2-ø3.2 (ø2.2 × 2) 1 to 540 1 to 85 Approx.
20 1 to 120 1 to 320 1 to 79
−40 to +50˚C 24g
7
Thickness: 4 2 m Free-cut 1 to 820 1 to 220 FU-43TZ
1 to 1000
2-ø2.2 (ø2.2 × 2) 1 to 540 1 to 85 Approx.
15 −40 to +50˚C 1 to 120 1 to 320 1 to 79 22g
8
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
Sleeve
Type Detecting distance (mm)*1
Fibre unit length Minimum Other power modes
Appearance Model
Beam emitting (Diameter) bend radius TERA (Longest)
(mm) MEGA TURBO Weight
direction Ambient ntemperature (mm) FINE (Initial) ULTRA HSPD
SUPER S-HSPD
Sleeve section
cannot be
bent ø2.8 2 m Free-cut 290 85 FU-31
ø2 340
(ø1.0 × 2) R10 220 22 Approx.
15 59
−40 to +70˚C 130 12 5g
15
Side
Min. bend radius ø4.8
of sleeve:
R25
ø2.1 15
1 m Free-cut 540 150 FU-33
750
(ø2.2 × 2) R25 420 54 Approx.
−40 to +70˚C 83 230 31
65 10g
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
30
Type Detecting distance (mm)*1
Fibre unit length Minimum Other power modes
Appearance Model
Beam emitting (Diameter) bend radius TERA (Longest)
(mm) MEGA TURBO Weight
direction Ambient ntemperature (mm) FINE (Initial) ULTRA HSPD
SUPER S-HSPD
Sleeve section M3
cannot be bent 110 46 FU-65X
ø0.82 50 cm cut not allowed. 150
R4 92 13 Approx.
15 −40 to +70˚C 33 68 7 5g
15
Sleeve section ø3
cannot be bent 100 46 FU-45X
ø0.82 50 cm cut not allowed. 120
R4 83 11 Approx.
15 −40 to +70˚C 33
5 68 6 4g
Sleeve section ø4
cannot be bent
ø1.65
2 m Free-cut
640 500 170 FU-43
15 (ø1.3 × 2) R25 390 50 Approx.
130 250 30
−40 to +70˚C 8g
22
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
High-flex
ø2
1 m Free-cut FU-49U
ø2 (ø1.0 × 2) Approx.
10 −40 to +50˚C 4g
ø3
1 m Free-cut R2 220 80 FU-48U
ø3 (ø1.0 × 2) ToughFlex 290 180 21 Approx.
−40 to +50˚C High-flex 59 110 12 4g
10
M3
1 m Free-cut FU-69U
M3 (ø1.0 × 2) Approx.
13 −40 to +50˚C 4g
ø1.5 FU-49X
1 m cut not allowed.
ø1.5 Approx.
−40 to +70˚C
15 250 91 3g
280
170 25
59
M3 130 14 FU-69X
1 m cut not allowed.
M3 Approx.
−40 to +70˚C
10 3g
R4
High-flex
ø3 2 m Free-cut FU-48
ø3 (ø1.0 × 2) Approx.
15 −40 to +70˚C 350 120 7g
500
270 32
M4 90 190 18
2 m Free-cut FU-68
M4 (ø1.0 × 2) Approx.
15 −40 to +70˚C 8g
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
31
Reflective
Oil/Chemical Resistant
Thickness 9.6 28
(width of ø4.1 40
2 m Free-cut FU-97P
Top mounting hole (ø1.3 × 2) R40 Approx.
seating surface) −40 to +60˚C 75g
8 to 20 8 to 20 200 x 200 mm
8 to 20
8 to 20 8 to 20 t = 0.7 mm
8 to 20 8 to 20 8 to 20
Thickness: 9 39 2 m Free-cut Glass substrate FU-97S
35.2
(ø1.3 × 2) Approx.
−40 to +85˚C 90g
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
Heat Resistant
M6 2 m Free-cut
900 810 430 FU-85Z
R5
100˚C*4 (ø2.2 × 2) 700 150 Approx.
ToughFlex 290
−40 to +100˚C 520 86 25g
17
M6 2 m Free-cut
1100 950 540 FU-85H
150˚C*5 (ø2.2 × 2) R20 870 150 Approx.
290 650 90
−40 to +150˚C 35g
17
M6 2 m Free-cut
1200 1000 560 FU-87
180˚C*6 (ø2.2 × 2) R35 890 170 Approx.
370 670 100
−60 to +180˚C 33g
17
M4
FU-87K
1 m cut not allowed.
200˚C R8 Approx.
−40 to +200˚C
10 15g
17
Min. bend
radius of M4
sleeve R10 790 770 500 FU-82C
1 m cut not allowed.
35 670 170 Approx.
ø2.1 −40 to +300˚C 350 600 100
90 29g
300˚C
FU-83C
M4 1 m cut not allowed.
R25 Approx.
ø2.6 −40 to +300˚C
10 23g
17
Min. bend
radius of M4
sleeve R10 670 650 470 FU-81C
1 m cut not allowed.
350˚C 40 590 140 Approx.
ø2.1 −30 to +350˚C 250 550 90 24g
90
29.7 8 to 62 8 to 51 FU-38LK
2m cut not allowed. 8 to 86 8 to 57 8 to 30 Approx.
17.1 −40 to +250˚C 8 to 51 8 to 54 9 to 23 70g
Thickness: 5
250˚C R25
27 FU-38K
1 m cut not allowed.
Approx.
19 −40 to +250˚C
45g
2.5 to 150 2.5 to 110 2.5 to 37
Thickness: 5
2.5 to 93 2.5 to 17
2.5 to 27
2.5 to 45 2.5 to 10
27 2 m Free-cut FU-38H
*6
180˚C 19 (ø2.2 × 2) R35 Approx.
−40 to +180˚C 45g
Thickness: 5
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.
*3 Use the fibre sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fibre unit.
*4 The recommended maximum ambient temperature during operation is 90°C when constantly using a fibre unit in a high-temperature environment.
*5 The recommended maximum ambient temperature during operation is 130°C when constantly using a fibre unit in a high-temperature environment.
*6 The recommended maximum ambient temperature during operation is 150°C when constantly using a fibre unit in a high-temperature environment.
32
Wide-range
15
2 m Free-cut
5 to 210
5 to 210 5 to 210 FU-11
15 mm
Area (ø2.2 × 2) R25 5 to 210 5 to 160 Approx.
(at distance 15 ) 7 5 to 210
−40 to +70˚C 5 to 210 5 to 110 19g
28
*1 When using the FS-N40 Series. Standard target: White mat paper (Reflective type only.) *2 R10 for the first 10 mm of cable from the housing.
Liquid-Level
2 m Free-cut FU-95S
Binding band x 2
16 (ø2.2 × 2) R5 Approx.
Nonslip rubber x 2
−40 to +70˚C 23g
FU-95Z
R2
2 m Free-cut Approx.
ToughFlex
ø4 to 26 (ø1.0 × 2) 7g
Binding band x 2
FU-95Z: Nonslip rubber x 2 FU-95HA
Tube-mountable 1 −40 to +50˚C R10 Spacer x 2 Approx.
FU-95HA: Screw x 2 7g
−40 to +105˚C * Nut x 2
FU-95: FU-95
−40 to +70˚C R10 Approx.
7g
2 m Free-cut FU-95W
More than ø26 —
16 (ø2.2 × 2) R5 Approx.
recommended (Optionally available)
−40 to +70˚C 20g
* The recommended maximum ambient temperature during operation is 90°C when constantly using a fibre unit in a high-temperature environment.
FU-93Z
R0.5
Approx.
2 m Free-cut ToughFlex
78g
(ø1.3 × 2)
Immersion R40 *
* Not bendable up to 80 mm from the tip.
33
Retro-reflective
Retro-reflective
Fibres with a cable diameter of 1.0 or 1.3 mm include Appearance Cable diameter Adaptor
an adapter to connect to the fibre amplifier. If you lose
the adapter, purchase the corresponding model listed ø1.3
Adaptor A
(OP-26500)
below.
Adaptor B
ø1.0
(OP-26501)
34
Thrubeam
M4×P0.7 3
SUS304 FU-V84
12 1 m cut not allowed.
350˚C Approx.
25 −40 to +350˚C
55g
Vacuum
side 21.1
M4×P0.7
SUS304 3 1800 610 FU-V84L
1 m cut not allowed. 2400
Thrubeam 350˚C R25 1200 210 Approx.
12 −40 to +350˚C 500
850 110 60g
Max 37
Across-flats: 8
2 m Free-cut FU-V7FN
Air side 70˚C (ø2.2) Approx.
−40 to +70˚C 30g
10
Type
Ambient Model
Appearance (mm) Material Accessory
Heat resistant ntemperature Weight
Detecting method
temperatures
FU-VJ1
Optical integrator for M5nut, spring washer, washer two (2) each
200˚C −10 to +200˚C Fibre: M
ulti-component glass Approx.
thrubeam set O-ring (2): Fluoro-rubber (JIS Type 4D)
45 25g
Type
Ambient Model
Appearance (mm) Features Accessory
Heat resistant ntemperature Weight
Detecting method
temperatures
An optical integrator can be used to seal the vacuum side and air side and
transmit light between the vacuum-side fibre and the air-side fibre. Optical
Vacuum chamber wall
integrators undergo leak testing prior to shipping. (Leak testing in which the
Acceptable plate thickness for mounting
leak amount is 1 × 10−10Pa · m3/sec or less)
2 to 12 mm: When using a tightening nut and spring washer
2 to 16 mm: When not using a tightening nut and spring washer
PRECAUTIONS
O-ring
Be careful when breaking the seal as the spring washer
vacuum side fiber and optical coupler are flat washer Finish the O-ring contact surface on the air side
placed in a package containing deaerator so that it has a surface roughness of 1.6 Rz
after being cleaned with alcohol. They are not (JIS B0601-2001) or more.
baked after cleaning, so bake before use. Mounting hole diameter: ø5.1+0.1, -0
35
Specifications
❚ Amplifier Units
NPN output FS-N41N FS-N42N FS-N43N FS-N44N FS-N41C*1
Model FS-N40
PNP output FS-N41P FS-N42P FS-N43P FS-N44P (Selectable output)
Cable/connector Cable M8 Connector *2
-
Main unit/expansion unit Main unit Expansion unit Main unit Expansion unit Main unit Expansion unit
No. of control outputs 1 1 2 2 2*3 None*4
No. of external inputs - - 1 1 1*3 -
Light source LED Transmitter side: Red, four-element LED (wavelength 660 nm)
23 μs (S-HSPD*5) / 50 μs (HSPD*6) / 250 μs (FINE) /
Response time
500 μs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
Open-collector, 30 V or less single output maximum 100 mA or less per output,
-
100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit)
Control output
NPN 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA)
Residual voltage -
PNP 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA)
External input Input time 2 ms (ON) / 20 ms (OFF) or longer*7
Up to 16 units (17 units connected in total including the main unit).
Unit expansion (excluding the FS-N41C)
However, each dual output type will be treated as two expansion units.
Protection against reverse power connection, protection against output overcurrent,
Protection circuit
protection against output surge, protection against reverse output connection
S-HSPD / HSPD 0 units, FINE 4 units, TURBO / SUPER / ULTRA / MEGA / TERA 8 units
Mutual interference prevention
(The mutual interference prevention values are twice those shown here when Double is set.)
Power voltage 10 to 30 VDC (including ripple (P-P) 10% or less), class 2 or LPS*8
During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)
NPN and
ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)
FS-N40 ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)
Single output type (FS-N41P/N42P) and FS-N41C
Power During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)
supply Power
ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)
consumption*9 ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)
PNP and
FS-N41C Dual output type (FS-N43P/N44P)
During normal operation: 990 mW or less (39 mA or less at 24 V/72 mA or less at 12 V)
ECO ON: 920 mW or less (36 mA or less at 24 V/66 mA or less at 12 V)
ECO FULL: 830 mW or less (33 mA or less at 24 V/59 mA or less at 12 V
Ambient light Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less
Ambient temperature -20°C to +55°C (no freezing)*10
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, each X, Y, Z axis for 2 hours
Shock resistance 500 m / s2 each X, Y, Z axis 3 times
Case material Main unit and cover: polycarbonate
Weight Approx. 78 g Approx. 48 g Approx. 83 g Approx. 73 g Approx. 25 g Approx. 23 g
36
❚ Multi-Output Unit
NPN output FS-MC8N
Model
PNP output FS-MC8P
No. of inputs / outputs Separate control outputs: 8, common output: 1, common input: 1
Response time Depends on the response time settings of the connected expansion units
Up to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.)
Unit expansion
Allowable passing current: 1200 mA or less
Indicators STATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange)
Separate control output, NPN output NPN open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.4 V or less
common output PNP output PNP open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.6 V or less
External input time Input time of the connected expansion units +11 ms
Protection against reverse power connection, protection against reverse output connection, protection against output
Protection circuit
overcurrent, protection against output surge
Power supply voltage*1 10 to 30 VDC (including ripple (P-P) 10% or less), class 2 or LPS
Power supply
Power consumption*2 690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current])
Ambient temperature -20°C to +55°C (no freezing)
Environmental resistance Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm; 2 hours each for X, Y, and Z axes
Shock resistance 500 m/s2; 3 times each for X, Y, and Z axes
Case material Main unit and cover: polycarbonate
Weight Approx. 110 g
*1 Match the rated power supply voltage of the expansion units to be connected to expand the system.
*2 The power consumption including the load when the maximum number of units are connected is 38 W max.
protection circuit
Overcurrent
protection circuit
Overcurrent
Load
Load
Select PNP or NPN and the function of I/O pin (2) during the initial settings.
2 4
Sensor pin layout 1 3
When using the sensor in PNP mode When using the sensor in NPN mode
[OUT1 + OUT2 selected] [OUT1 + INPUT selected] [OUT1 + OUT2 selected] [OUT1 + INPUT selected]
10 to 10 to 10 to 10 to
1 Brown 30 VDC 30 VDC 1 Brown 30 VDC 30 VDC
circuit
protection
Overcurrent
protection circuit
Overcurrent
protection circuit
Overcurrent
Load
Load
Load
Main circuit
Main circuit
Main circuit
2
4 Black 4 Black 4 Black
4 Black
circuit
protection
Overcurrent
2 White 2 White
Load
Load
Load
The wire colors indicate the colors when using an OP-73864/73865 M8 connector cable (sold separately).
❚ Multi-Output Unit
FS-MC8N FS-MC8P
10 to 30 VDC 10 to 30 VDC
Brown Brown
protection circuit
Overcurrent
protection circuit
Overcurrent
Load
Load
PLC, etc.
Sensor main circuit
Pink
Pink (common input) Short circuit (common input)
current 1 mA
PLC, etc. or less
0V 0V
Blue Blue
37
Dimensions Units: mm
FS-N41N/N41P/N43N/N43P FS-N42N/N42P/N44N/N44P
Main Unit Expansion Unit
(Cable Type) (Cable Type)
10.7 10.7
Max.
175°
Maximum 3.5 Maximum 3.5
when cover is when cover is
opened opened
105.2 105.2
30.5 4 30.7
4 30.5
30.7 (14)*3
(35.5) (13) (35.5)
8.1 8.1
25.7 35.4 25.7 35.4
76.8 Min. 8 76.8 Min. 7*2
FS-N41C FS-N40
Main Unit (M8 Connector Type) Expansion Unit (Zero Line Type)
10.7 10.7
Max.
175°
(16.2) (18.7)
(38.7) (38.7)
2-(4.4×3.4) 2-(4.4×3.4)
Counterbore Ø7.2 Depth 3.2 Counterbore Ø7.2 Depth 3.2
38
❚ Common to All Models
10.4 6 L 6
20.8 35.4
Min. *1. When using expansion units, be sure to use the end unit. (Optional)
74.9
15
10
39
Certainty and Simplicity.
Once you use it, you’ll never let it go.
www.keyence.com
Copyright (c) 2017 KEYENCE CORPORATION. All rights reserved. FSN40-KPH-C-GB 1127-1 638005