You are on page 1of 2

Optex Incorporated Description

Doc: Architect/ Engineer Specifications


Model: AX-250 Plus/ AX-500 Plus
Desc: Outdoor Medium-Long-Range
th
1845 W. 205 St. Photoelectric Intrusion Detector
Torrance, CA 90501-1510 USA
TEL (310) 533-1500 and (800) 966-7839
FAX (310) 533-5910

NOTE: Words/statements within square brackets [ ] may be included when appropriate, or when selection is required.

The Intrusion Detector[s] shall operate POWER REQUIREMENT


on the Verified Intrusion principle using
The detector[s] shall be capable of
Infrared Photoelectric, and shall be Listed by
operating from a DC power source rated
Underwriter's Laboratories, Inc..
within the range of 10.5 to 30 volts DC. The
current draw (transmitter + receiver) shall be
a maximum of 50 mA during normal
OUTPUT AND ENCLOSURE
operation.
[Each] [The] detector shall provide the
detection, signal processing, alarm relay,
and operating power circuitry in the same ALARM OPERATION
enclosure; and shall provide an alarm relay
A condition of alarm shall occur when
actuation upon the detection of an intruder
the alarm conditions are met. The Beam
moving into or through its protection pattern.
Interruption Period shall be adjustable within
The housing cover and chassis shall be
the range of 50 ~ 500 msec. to increase
highly durable and heat resistant, and shall
stability while maintaining reliability at every
be capable of mounting to a Wall or Pole
installation site. The beam characteristics
without modification.
shall be pulsed infrared. The Alarm Period
shall be 2.0 ± 1 seconds nominal. The
The total weight (both Transmitter and
Alarm Output shall be capable of handling
Receiver) shall be 95.2 oz. (2700g).
28VDC, 0.2A max., Form C Relay. [Each]
[The] detector shall signal the condition of
[Each] [The] detector shall feature a
alarm using a Form C Relay with terminal
single piece electronic logic board whose
strip connections. [Each] [The] detector
circuitry is specifically designed for this
shall also contain an N.C. tamper switch on
detector alone, and which has sustained a
the receiver only that shall open when the
substantial “Burn-in” test for several days.
cover is removed.
The case shall include easy wiring
knockouts for a ½ inch conduit, stainless
steel screws, and a back plate.
SENSOR STABILITY
[Each] [The] detector shall feature
LED OPERATION protection against Lighting and High EMI
Disturbances. An improved EMI Surge
The detector[s] shall incorporate a
Absorber and High Surge Resistiveness
single, Red LED to indicate the operating
Relay shall maintain stable operation even
conditions. Red LED illuminated shall
in the most lightning prone areas, and shall
indicate an alarm condition. Red LED not
remain stable against over 14kV of lightning
illuminated shall indicate a non-alarm
surge.
condition.
[Each] [The] detector shall remain stable
even in high temperature conditions. [Each]

Doc #: 3440-0324
[The] detector shall be rated to operate due to birds or flying objects. The “And
within a temperature range of [minus 13° Gate” dual beams shall require
Fahrenheit to plus 131° Fahrenheit] [minus simultaneous interruption of both beams to
25° Celsius to plus 55° Celsius]. [Each] trigger an activation. No activation shall be
[The] detector shall also tolerate a humidity generated when a bird or falling leaves
rate of 95% max. No false alarm shall occur break just one beam.
within these operating conditions.

[Each] [The] detector shall contain an LENS AND DETECTION PATTERN


A.G.C. (Automatic Gain Control) Circuit to
continually monitor for gradual changes in [Each] [The] detector shall contain a
the signal’s strength caused by changing durable and high grade Aspherical lens that
weather conditions. It shall adjust the shall focus received infrared energy onto the
sensitivity accordingly to maintain the proper sensor.
signal level for the current environmental
conditions. The precise area of the detection field
shall be specific to each model. Model AX-
[Each] [The] detector shall provide 250 Plus shall feature a detection field of
protection against rain, dust, and insects by 250ft (75m) Outdoor, with a Maximum
means of a sealed enclosure housing. The Arrival Distance of 2500ft (750m). Model
Rubber O-Ring and Rubber Grommets AX-500 Plus shall feature a detection field of
(IP55) used in the detector[s] shall prevent 500ft (150m) Outdoor, with a Maximum
rain, dust, and tiny insects from adversely Arrival Distance of 5000ft (1500m).
affecting performance.
Fine optical beam alignment shall also
[Each] [The] detector shall feature frost be incorporated into the detector[s]. The
and dew protection. An anti-frost and adjustment shall be horizontally (180°/ ±
convex visor design shall be incorporated to 90°) or vertically ( ± 10°),
protect the detector[s] from the effect of frost
or snow. Stable operation shall be
maintained with as much as 99% of the MODEL
beam’s energy blocked by heavy rain, dust
The Intrusion Detector shall be model
storms, snow or fog.
AX-250 Plus (Outdoor Medium-Long-Range
Photoelectric Intrusion Detector), [or] [model
[Each] [The] detector shall utilize Twin
AX-500], [with] [optional Back Cover BC-1],
Synchronized Pulsed Beams with size
[or] [with] [optional Heating Unit HU-1].
analysis technology to eliminate false alarms

Doc #: 3440-0324