N ODUP 6HWWLQ 3DUDPHWHU ■ (WKHUQHW RPPXQLFDWLRQ 6HWWLQ 3DUDPHWHU ( WHUPLQDO UHD ■ /LQN RPPXQLFDWLRQ 6HWWLQ 3DUDPHWHU 87 ( WHUPLQDO UHD
Menu symbol: (OUT) Menu symbol: (HBA) Menu symbol: (ETHR)
87 ( WHUPLQDO UHD
3DUDPHWHU ,QLWLDO 8VHU 'LVSOD 3DUDPHWHU ,QLWLDO 8VHU 'LVSOD 3DUDPHWHU ,QLWLDO 8VHU 'LVSOD Menu symbol: (CC-L)
1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H
V PERO YDOXH VHWWLQ OHYHO V PERO YDOXH VHWWLQ OHYHO V PERO YDOXH VHWWLQ OHYHO
3DUDPHWHU ,QLWLDO 8VHU 'LVSOD
1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H
Control output or Heating-side control Heater break alarm-1 High-speed response V PERO YDOXH VHWWLQ OHYHO
output (Lower two digits) OFF, 1 to 8
(HB1.S) I F H HF 0: Heater current measurement (HSR) P H 156K: 156k bps
00: OFF 1: Heater break alarm (Heating-side) 625K: 625k bps
01: OUT terminals (voltage pulse) Heater break alarm-2 2: Cooling-side heater break alarm 9600: 9600 bps
H 2.5K: 2.5k bps 10M
02: OUT terminals (current) I F H HF (BPS) H 19200: 19.2k bps 38400 (BR)
(HB2.S) 5M: 5M bps
03: OUT terminals (relay) 38400: 38.4k bps
10M: 10M bps
Output type selection 06: OUT2 terminals (relay) 6 Heater break alarm-1 NONE: None
07: RET/OUT2 terminals (voltage type: OFF
(HB1) F H HS 3 EVEN: Even EVEN
pulse) 00.03 (PRI) Address
OFF, 0.1 to 300.0 Arms EASY ODD: Odd (ADR)
08: RET/OUT2 terminals (current) EASY
Heater break alarm-2
Cooling-side control output (Upper Heating/ OFF 0 to 255
(OT) Upper two (HB2) F H HS 9600: 9600 bps
digits two digits) cooling Initial value: Table
3 H 6HH HI H 19200: 19.2k bps 38400
Lower two 00: OFF type: CT1 (IP1).(IP2).(IP3).(IP4) = below (BPS)
800 38400: 38.4k bps
digits 01: OUT terminals (voltage pulse) 06.03 coil winding number ratio (IP1 to IP4) (192).(168).(1).(1)
(CT1.T)
02: OUT terminals (current) 1 to 3300 0 to 255 0 to 3 and 6
03: OUT terminals (relay) CT2 Initial value: Table Pro le number (0, 1 and 6: Ver.1.10) (2 and 3: 0
06: OUT2 terminals (relay) 800 Subnet mask 1 to 4 6HH HI (FILE) Ver.2.00)
(CT2.T) coil winding number ratio (SM1).(SM2).(SM3).(SM4) = below
07: RET/OUT2 terminals (voltage (SM1 to SM4) (255).(255).(255).(0)
pulse) Heater break alarm-1
08: RET/OUT2 terminals (current) 0.00 0 to 255
(HDN1) On-delay timer ■ Key Action Setting Parameter
0.00 to 99.59 (m.s) STD Initial value: Table
Control output cycle time Default gateway 1 to 4 6HH HI EASY
Heater break alarm-2 (DG1).(DG2).(DG3).(DG4) = below Menu symbol: (KEY)
Heating-side control 0.00 (DG1 to DG4) (0).(0).(0).(0)
30.0 s On-delay timer
(CT) output cycle time (in (HDN2)
3DUDPHWHU ,QLWLDO 8VHU 'LVSOD
Heating/cooling control) EASY 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H
0.5 to 1000.0 s In cases where the current transformers manufactured by U.R.D. Co., Ltd are used, set Port number 502, 1024 to 65535 502 V PERO YDOXH VHWWLQ OHYHO
(PRT)
the following value for the coil winding number ratio. OFF: Disable
Cooling-side control
30.0 s A/M: AUTO/MAN switch
(CTc) S F F H PH CTL-6-S-H: 800 3 FFH H F OFF: Disable, ON: Enable OFF User function key-1 R/L1: REM/LCL switch OFF
(IPAR) action setting
CTL-12L-30: 3000 (F1) S/R: STOP/RUN switch
Automatic valve position OFF: Stop automatic adjustment AUTO: Switch to AUTO
OFF 0 to 255 MAN: Switch to MAN
(V.AT) adjustment ON: Start automatic adjustment
■ 56 RPPXQLFDWLRQ 6HWWLQ 3DUDPHWHU 87 ( WHUPLQDO , Permitted IP address 1-1 Initial value: REM1: Switch to REM
Setting V.RS to ON resets the valve to 1-4 (1.IP1).(1.IP2).(1.IP3).(1.IP4) = Table LCL1: Switch to LCL
Valve position setting 6HH HI User function key-2
adjustment settings and causes the OFF UHD 87 ( WHUPLQDO UHD Permitted IP address 2-1 (255).(255).(255).(255) below STOP: Switch to STOP OFF EASY
(V.RS) H H action setting
indication “V.RS” to blink. to 2-4 (2.IP1).(2.IP2).(2.IP3).(2.IP4) = (F2) RUN: Switch to RUN
Menu symbol: (R485)
Pressing the SET/ENTER key with (1.IP1 to 1.IP4, (255).(255).(255).(255) AT: Auto-tuning
3DUDPHWHU ,QLWLDO 8VHU 'LVSOD 2.IP1 to 2.IP4) LTUP: LCD brightness UP
valve position set to the fully-closed 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H
V PERO YDOXH VHWWLQ OHYHO LTDN: LCD brightness DOWN
Fully-closed valve posi- position by Down arrow key causes Setting this parameter to “ON”
- BRI: Adjust LCD brightness
(V.L) tion setting the adjusted value to be stored. When PCL: PC link communication enables the Ethernet communication User function key-n
V.L adjustment is complete, V.L stops Ethernet setting switch OFF LCD: LCD backlight ON/OFF switch PID
PCLSM: PC link communication (with (ESW) parameter settings. (Fn) action setting LAT: Latch release
blinking. checksum) OFF, ON PID: PID tuning switch
Pressing the SET/ENTER key with LADR: Ladder communication
Use the following table to record Ethernet communication setting value.
valve position set to the fully-opened CO-M: Coordinated master station
Fully-opened valve posi- position by Up arrow key causes the CO-S: Coordinated slave station 3 PH H n=1 n=2 n=3 n=4
- 3 F H HF MBASC: Modbus (ASCII) MBRTU
(V.H) tion setting adjusted value to be stored. When V.H 3
■ Display Function Setting Parameter
adjustment is complete, V.H stops (PSL) MBRTU: Modbus (RTU)
CO-S1: Coordinated slave station 6 Menu symbol: (DISP)
blinking
(Loop-1 mode) 3DUDPHWHU ,QLWLDO 8VHU 'LVSOD
DGn 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H
Valve traveling time 5 to 300 s 60 s CO-S2: Coordinated slave station V PERO YDOXH VHWWLQ OHYHO
(TR.T) (Loop-2 mode) 3
P-P: Peer-to-peer communication 0: Fixed in white
0: Valve position feedback type 3 1: Fixed in red
1: Valve position feedback type STD 600: 600 bps 2: Link to alarm 1 (Alarm OFF: white,
(moves to the estimating type if a 1200: 1200 bps Alarm ON: red)
Valve adjusting mode 0 2400: 2400 bps 3: Link to alarm 1 (Alarm OFF: red,
(V.MOD) feedback input error or break oc- EASY ■ 352), 86 '3 RPPXQLFDWLRQ 6HWWLQ 3DUDPHWHU ( WHUPLQDO UHD
curs.) H 4800: 4800 bps 19200 Alarm ON: white)
2: Valve position estimating type (BPS) 9600: 9600 bps 4: Link to alarm 1 or 2 (Alarm OFF:
Menu symbol: (PROF)
19200: 19.2k bps white, Alarm ON: red)
38400: 38.4k bps 3DUDPHWHU ,QLWLDO 8VHU 'LVSOD Active color PV display 5: Link to alarm 1 or 2 (Alarm OFF:
OFF: Disable 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H red, Alarm ON: white) 0
PV1: PV V PERO YDOXH VHWWLQ OHYHO F
NONE: None (PCMD) 6: PV limit (Within range: white, Out
SP1: SP 3 EVEN: Even EVEN 9.6K: 9.6k bps of range: red)
OUT1: OUT (Valve opening: 0 to 100 (PRI) ODD: Odd 19.2K: 19.2k bps 7: PV limit (Within range: red, Out of
% in Position proportional control) EASY
93.75K: 93.75k bps range: white)
Retransmission output LPS: 15 V DC loop power supply Stop bit 1: 1 bit, 2: 2 bits 187.5K: 187.5k bps 8: SP deviation (Within deviation:
PV1 EASY white, Out of deviation: red)
(RTS) type of RET TSP1: Target SP (STP) 0.5M: 0.5M bps
HOUT1: Heating-side OUT H 1.5M: 1.5M bps AUTO 9: SP deviation (Within deviation: red,
COUT1: Cooling-side OUT (BR) 3M: 3M bps Out of deviation: white)
Data length 7: 7 bits, 8: 8 bits 8 10: Link to DI (ON: red, OFF: white)
MV1: Position proportional output (DLN) 6M: 6M bps
(internal computed value) 12M: 12M bps PV color change high Set a display value when in PV limit
PV: PV terminals analog input AUTO or SP deviation. 0
Address 1 to 99 (PCH) P
(ADR) 45.45K: 45.45k bps EASY -19999 to 30000 (Set a value within
the input range.)
When RTS = PV1, SP1, TSP1, PV 100 % PV color change low limit Decimal point position depends on 0
Maximum value of Address 0 to 125
RTL + 1 digit to 30000 of PV (ADR) (PCL) H S SH
H P S -19999 to RTH - 1 digit
(RTH) S
scale of RET Decimal point position: 9600: 9600 bps 0: Disable
range
When RTS=PV1, SP1, or TSP1, H 19200: 19.2k bps 38400 1: OUT, Heating-side OUT, Internal value
HF P S S PH (BPS) 38400: 38.4k bps 3 S S F
0% 2: Cooling-side OUT
Minimum value of that of PV input.
of PV 3: PV
H P S When RTS=PV, decimal point position Pro le number 0 to 3 0 Bar-graph display regis- (Heating
(RTL) S (FILE) 4: SP
scale of RET is same as that of PV input scale. 5: Deviation /cooling
range (BAR1)
6 to 16: Disable type: 1)
Retransmission output 17: Feedback input (valve opening)
type of OUT current Same as RTS OFF ■ 'HYLFH1HW RPPXQLFDWLRQ 6HWWLQ 3DUDPHWHU ( WHUPLQDO UHD 18: PV terminals analog input
(O1RS) S 24: TSP
Menu symbol: (DNET) 25: TSP deviation
,0 3 ' (1 SD H
■ SELECT Display Setting Parameter ■ AL1-AL3 Function Registration Parameter ■ Error and Version Con rmation Parameter (for display only)
Menu symbol: (CSEL) Menu symbol: (ALM) Menu symbol: (VER)
3DUDPHWHU ,QLWLDO 8VHU 'LVSOD 3DUDPHWHU ,QLWLDO 8VHU 'LVSOD 3DUDPHWHU 'LVSOD
1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H 1DPH RI 3DUDPHWHU 6HWWLQ 5DQ H 1DPH RI 3DUDPHWHU 6WDWXV UHFRUG
V PERO YDOXH VHWWLQ OHYHO V PERO YDOXH VHWWLQ OHYHO V PERO OHYHO
Register the operation parameter Set an I relay number. For the items
(except the Operation Mode) that is other than below, see Communication 3 PH H H
AL1 function selection (PA.ER)
frequently modi ed to display it in the (AL1.S) User's Manual.
SELECT Display-1 to -5 Table
Operation Display. OFF STD Ex.) Set the number 4353 for AL1.S
registration below
OFF, 2301 to 5000, 6701 to 6710 H H P Option error status
(CS1 to CS5) (OP.ER)
For the setting range, see Communi- Set “OFF” to disable the function.
cation User's Manual. AL2 function selection
(AL2.S) No function: OFF A/D converter error status 1
Use the following table to record SELECT Display setting value. Alarm 1: 4353 (AD1.E)
3 PH H n=1 n=2 n=3 n=4 n=5 Alarm 2: 4354
AL3 function selection Alarm 3: 4355 STD A/D converter error status 2
CSn Alarm 4: 4357 (AD2.E)
(AL3.S)
,0 3 ' (1 SD H