The Clariant analytical department decided for a number of quality release tests for Poly-
glykols to use a more up to date method and/or a method which indicates higher accuracy
than the method described in one of the pharmacopoeia monographs.
Please find a detailed comparison:
* just valid for products with Pharma specification and batch number DE....
Seite 2 von 5
CLARIANT
Seite 3 von 5
CLARIANT
Viscosity:
2.2.9 capillary viscometer method (kinematic viscosity)
Average molecular weight of 300 to 8000:
Clariant uses DIN 51562, which is identical to Ph. Eur. 2.2.9, but a more detailed description. As de-
scribed in Ph. Eur. method 2.2.9, the kinematic viscosity is determined in order to calculate the dy-
namic viscosity by multiplying with the density of Macrogols.
Seite 4 von 5
CLAR IANT
Freezing point:
2.2.18 - Freezing point
For Polyethylene Glycols with a molecular weight of < / = 1500 g/mol, Clariant uses a validated
method (calculation out of viscosity) instead of the time consuming Ph. Eur. 2.2.18 method (validation
report available).
For Polyethylene Glycols with a molecular weight of> / = 2000 g/mol Clariant uses a DSC method in-
stead of the time consuming Ph. Eur. 2.2.18 method (validation report available).
As this aspect is not defined in the above mentioned monograph for the Polyethylene Glycol types with
molecular weight 10000 g/mol and 12000 g/mol, this aspect is not specified in the general Clariant
specification of these types.
This item is given in the specification as specification item "Solidification point".
Sulfated ash:
2.4.14 Sulfated ash
Clariant uses an own ICP-OES method. This method was compared to the Ph.Eur. (Sulfated ash) and
USP-NF (Residue on ignition) methods, which describe the same aspect. The limit given in the USP-NF
method is lower than the Ph. Eur. limit. Therefore Clariant uses the lower specification limit of 0.1%
for both specification items. The measurement is performed through a periodic testing procedure (vali-
dation report available).
Formaldehyde:
2.2.25 absorption spectrophotometry ultraviolet and visual
Clariant conducts the Ph.Eur. method (photometric).
This is given in the specification as specification item "Formaldehyde Ph. Eur.".
This Letter of Commitment shall be valid for two years after the date written above.
Yours sincerely