Operating instructions
Working Range Limiter
The passing on or duplication of this document as well as the use and disclosure of its contents are prohibited
unless expressly permitted. Offenders will be liable for damages. All rights pertaining to registration of patent or utility
model are reserved.
1.3 Additional operating and display elements on the crane control display . . . . . . 1 - 3
1.3.1 Additional symbol in main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 3
1.3.2 Working Range Limiter submenu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 4
1.4 Operating Working Range Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 7
1.4.1 Reading current settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 7
1.4.2 Entering a limiting value for a maximum total height . . . . . . . . . . . . . . . . . . . . 1- 9
1.4.3 Entering a limiting value for a maximum working radius . . . . . . . . . . . . . . . . . 1- 10
1.4.4 Entering limiting values for maximum slewing angles . . . . . . . . . . . . . . . . . . . 1- 11
1.4.5 Enter point data for objects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 14
1.4.6 Entering limiting values manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 17
1.4.7 Switching monitoring on and off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 19
1.5 Shutdown with Working Range Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 21
1.5.1 Switched-off crane movements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 21
1.5.2 Error messages from shutdown with Working Range Limiter. . . . . . . . . . . . . . 1 - 23
05.02.2001
1.1.1 Validity
These operating instructions only apply to the truck crane with the works
number that is on the cover sheet of these operating instructions.
This truck crane has been equipped at the factory with an adjustable
Working Range Limiter by Deutsche GROVE GmbH.
These operating instructions only describe the menus and displays on the
Crane control display that are available with additional equipment with the
Working Range Limiter and therefore supplement the standard GMK 4075
operating instructions.
G
Danger of accident due to unsupervised situations!
The working range limiter only serves as an additional safety device. Brake
the crane movement in time before the obstacle, do not knowingly drive
into the shutdown area. You, the crane operator, continue to have the re-
sponsibility of supervision for the working area, so that you can react ac-
cordingly to the occurance of incidnents that are not electronically moni-
tored.
s
05.02.2001
G
Danger of accidents due to limit values having been set too low
When entering the limit values, be aware that even after switching off the
motor movement can occur that would bring the load into the shutdown
area (e.g. due to load swing or bend of the boom). For this reason, enter the
limit value to the object with sufficient safety distance.
G
.
Danger of accident because the legally prescribed safety distance was not
observed!
Even when the working range limiter is switched on, always observe all
safety distances according to the country's legal regulations (e.g. con-
cerning electrical overhead cables).
The Working Range Limiter submenu contains symbols for operation, sym-
bols for opening further submenus and various displays.
Maximum slewing In this submenu are the symbols and displays for adjusting the slewing
angle entry sub- angle limit
menu
Entry point data In this menu there are displays and symbols for entering limiting points for
for objects sub- various objects.
menu
• Press the button in the main menu next to the Working Range Limiter sym-
bol (1).
The Working Range Limiter submenu opens.
G
Danger of accident due to unsupervised situations!
When entering the limit values, be aware that even after switching off the
motor movement can occur that would bring the load into the shutdown
area (e.g. due to load swing or bend of the boom). For this reason, enter the
limit value to the object with sufficient distance.
Display moni- You can check in the Working Range Limiter submenu which monitoring
toring switched functions are switched on or off.
on/off
s
05.02.2001
Read entered You can check in the Working Range Limiter submenu which limiting values
limiting values are entered for the individual monitoring functions.
H
All illustrations in these operating instructions use metric measuring units.
Depending on the country in which you are working, the display can also be
in US units of measurement; conversion is carried out at the factory.
The displays
1 Maximum/Current total height
2 Maximum/Current working radius
3 Maximum/Current slewing angle
H
The displays surrounded in blue only show the current value if the manual
entry is switched off. When the manual entry is switched off, the value can
be changed in the display as desired; à
Entering limiting values manually,
p. 1 - 17.
The values for the point data of individual objects can only be read for ob-
jects in the Point data entryfor objects submenu;à Enter point data for objects,
p. 1 - 14. 05.02.2001
This section presupposes that the value for the maximum total height is un-
known and therefore describes the input by starting the switching point. For
this, the following prerequisites must be fulfilled:
– manual entry is switched off;à Entering limiting values manually, p. 1 - 17,
– total height monitoring is switched off; à Switching monitoring off,
p. 1 - 20.
H
If the monitoring is switched on, you cannot start any larger limiting value
as the monitoring would switch off crane movement.
If manual entry is switched on, you cannot adopt the values for the currently
started switching point.
H
You can cancel the following entry at any time by pressing the Exit submenu/
entry mode ( ) button once. The red bar under the selected entry goes out.
ö
H
When the value for the maximum total height is known, you can also enter
this value manually and adopt is as the limiting value; à
Entering limiting
values manually, p. 1 - 17.
05.02.2001
This section presupposes that the value for the maximum working radius is
unknown and therefore describes the input by starting the switching point.
For this, the following prerequisites must be fulfilled:
à Entering limiting values manually, p. 1 - 17,
– manual entry is switched off;
– working radius monitoring is switched off; à Switching monitoring off,
p. 1 - 20.
H
If the monitoring is switched on, you cannot start any larger limiting value
as the monitoring would switch off crane movement.
If manual entry is switched on, you cannot adopt the values for the currently
started switching point.
H
You can cancel the following entry at any time by pressing the Exit submenu/
entry mode ( ) button once. The red bar under the selected entry goes out.
ö
H
The entered value for the maximum working radius influences the presen-
tation of the defined object. Only those points are displayed that are located
within the maximum working radius!
05.02.2001
H
When the value for the maximum working radius is known, you can also en-
ter this value manually and adopt is as the limiting value; à
Entering limit-
ing values manually, p. 1 - 17.
This section presupposes that the values for the maximum slewing angles
are unknown and therefore describes the input by starting the switching
points. For this, the following prerequisites must be fulfilled:
– manual entry is switched off; à
Entering limiting values manually, p. 1 - 17,
– slewing angle monitoring is switched off; à
Switching monitoring off,
p. 1 - 20.
H
If the monitoring is switched on, you cannot start any larger limiting value
as the monitoring would switch off crane movement.
If manual entry is switched on, you cannot adopt the values for the currently
started switching point.
H
You can cancel the following entry at any time by pressing the Exit submenu/
entry mode ( ) button once. The red bar under the selected entry goes out.
ö
Displays in sub- Definition: A displayed 0° angle means that the superstructure is turned
menu Working backwards (is therefore in the 0° to the rear working position. A complete ro-
Range Limiter tation out of this working position is separated into two semicircles for the
display:
– angles in right semicircle are displayed positively (0° to +180,0°),
– angles in left semicircle are displayed negatively (0° to –179,9°).
s
Operating instructions 2 084 658 en 1 - 11
Working Range Limiter
Working Range Limiter
1.4 Operating Working Range Limiter
Presentation of In the Maximum slewing angle entry submenu, the entered slewing angles A
slewing angles and B are presented pictorially in the Limited slewing angle display.
G
Risk of accident due to defectively set slewing angle.
Observe the definitions of slewing angles A and B when starting the
switching points.
– When the value for slewing angle A is adopted, the switching point must
always be located to the left next to the boom.
– When the value for slewing angle B is adopted, the switching point must
always be located to the right next to the boom.
If you swap the values for slewing angles A and B, the switching points are
then located within the permissible slewing range.
05.02.2001
Entering the In the Maximum slewing angle entry submenu, you can enter the values for
slewing angle slewing angles A and B individually one after the other.
H
When the values for slewing angles A and B are known, you can also enter
the values into the selected displays manually and adopt them as a limiting
value; à Entering limiting values manually, p. 1 - 17.
05.02.2001
This section presupposes that the parameters for the point data of the ob-
jects are unknown and therefore describes the input by starting the switch-
ing points. For this, the following prerequisites must be fulfilled:
– manual entry is switched off; à
Entering limiting values manually, p. 1 - 17,
– monitoring of objects, working radius and slewing angle are all switched
off; àSwitching monitoring off, p. 1 - 20.
H
When the monitoring functions are switched on, the required crane move-
ments for starting individual points can be switched off.
If manual entry is switched on, you cannot adopt the values for the currently
started switching point.
H
You can cancel the following entry at any time by pressing the Exit submenu/
entry mode ( ) button once. The red bar under the selected entry goes out.
ö
• Press the button near the symbol Point data for objects entry submenu (1)
once.
The Point data for objects entry submenu opens.
Presentation of The Point data for objects entry submenu opens. All entered points are pre-
defined objects sented pictorially in the Limitation by object display.
All entered points are represented by a cross
and numeration in the Limitation by object dis-
play (e.g. point 1).
Points that are connected to one object are fas-
tened with lines (e.g. points 1 to 3 and points 5
and 6).
The pictorial presentation corresponds to the
values in the Point data display (7). Every point
is defined by two values:
– by the angle for positioning the superstruc-
ture and
– by the working radius.
The current boom position is always repre-
05.02.2001
Selecting and You can delete selected point data to change objects or delete all point data
deleting point to define new objects.
data
s
05.02.2001
Entering point To enter point data, you can move the boom head to the corresponding
data position and directly adopt the current data for any point.
The point is only displayed when it is within the maximum radius. If needed,
you could enlarge the maximum radius so that the point will be shown.
Therefore you have the entry options for the following objects:
– 1 object with a maximum of 8 points or
– 2 objects with a maximum of 7 points altogether or
– 3 objects with 2 point each.
H
05.02.2001
When the values for the point data are known, you can also enter the values
into the selected points manually and adopt them as a limiting value;
à Entering limiting values manually, p. 1 - 17.
If you know the values for the switching points, you can also enter these
values manually.
Limiting values for In all entry menus is the symbol Manual entry on/off. After the menu in
total height, work- opened, manual entry is always switched off.
ing radius or slew-
ing angle
• To switch manual entry on and off press the button under the Manual entry
on/off switch (1).
After pressing the button, the background colour of the symbol changes:
Background yellow: Manual entry on
Background black: Manual entry off
s
05.02.2001
Manual point data The Manual entry on/off symbol is located in the submenu Entry of point data
entry for objects.
• To switch on manual entry press the button under the Manual entry on/off
symbol (1).
The symbol has a yellow background.
• To switch off manual entry, press the Exit submenu/entry mode button once (2).
The symbol (1) has a black background.
• If you press the button under the Manual entry on/off symbol, the red bar
moves to under the value for the working radius in display (9).
• Enter the new value and confirm it.
Switching moni- After the ignition is switched on, all monitoring functions are switched on
toring on that were on before the ignition was switched off.
G
Danger of accident due to erroneously set limit values!
If, during starting operations or after entering new limit values, you switch
on the monitoring, then make sure that the settings for the limit values are
correct. Start up the limit value slowly and check whether the movement
has been switched off at the right time.
If necessary, enter new values with a larger safety distance.
H
After switching on the monitoring, all of the driving gears' speeds are
limited to a maximum of 50 %. This is also valid for the driving gear where
higher values are set in the submenu Driving gear speeds. Limits under 50 %
continue to be active. A limit between 30 and 50 % is recommended for the
slewing gear speed.
s
05.02.2001
H
When the monitoring is switched on, it is impossible to drive behind a
defined object.
Switching moni- After the ignition is switched on, all monitoring functions are switched off
toring off that were off before the ignition was switched off.
H
Displays (1) to (3) show the last entered limiting value, even when monitoring
is switched off. The black symbol is always the standard for switching off.
05.02.2001
sion1)
1) additional equipment)
Bypassing If the monitoring of the Working Range Limiter is switched off after shut-
shutdown down has been carried out in the Working Range Limiter submenu, the shut-
down is maintained for safety reasons
G
Risk of accidents from overriding a shutdown.
Override the shutdown only if absolutely necessary and if you can clearly
observe the danger zone. Remember that, because of boom bending, the
overall height of the truck crane increases when putting down the load.
When you press the Override key-operated push button, shutdown of crane
movements listed in the table above is bypassed (switched off).
05.02.2001
When there is a shutdown from the Working Range Limiter, the Information
display shows one of the following error messages.