You are on page 1of 4

www.pceups.

com

ACT GREEN

MX31 10~20KVA

True online double conversion design Output power factor 0.9

Active input Power Factor Correction (PFC 0.99) Pure sinewave output with less than 5% THD

Fully digitized microprocessor control 50/60 Hz frequency converter mode

Wide input voltage range Built in Automatic bypass

N+X parallel redundancy configuration 1 Up to 4 units connected in parallel 1

Emergency power off function (EPO) High overload capability and enhanced short circuit protection

DSP technology guarantees high performance Optional OVCD protection

3-stage smart charging design Generator compatible

On-line output voltage selection Multi-function LCD display

Programmable power management outlets Very high surge immunity up to 70KV, 13KA, 1300J

Software monitoring and control SNMP/USB/RS-232/AS-400 communications

Eco mode for energy saving


Product Introduction The MX UPS has a very wide input-voltage tolerance
(from 190V to 520V) which allows the UPS to provide a
The MX UPS is now available from 10VA to 20kVA in
constant output voltage while keeping the batteries on
single phase output version. The true on-line intelligent
the charger. This way, the batteries are not used as
double conversion design of the MX UPS enables it to act
heavily, which maximizes the availability backup time
as a secure power infrastructure that guarantees the
and extends the battery life.
delivery of the highest power quality to your loads. The
MX UPS provides a multitude of features allowing it to • Output power factor 0.8
meet the diverse requirements that an organization MX UPS is a high-density UPS with output power factor
might have: it provides high tolerance to input voltage 0.8 to provide higher performance and efficiency to
and frequency fluctuations while supplying a pure critical applications.
sinewave output with less than 2% of Total Harmonic
• Active input power factor correction 0.99
Distortion (THD).
This feature will save more energy and its power factor
The MX UPS is designed with high-availability in mind. performance is more stable to meet higher environment
For this reason, it comes packed with features that allow standards.
it to keep operating under a variety of possible power
• Galvanic isolation transformer (Optional)
disruptions.
The isolation transformer may be used in situations
where you increase the quality of your power output
Applications
even more. This transformer ensures complete galvanic
The MX Series provides a secure power infrastructure for isolation of your power supply from the loads.
a wide range of applications including:
High Availability
• Commercial Processing System
• Cold Start on battery power
• Storage Area Networks (SAN)
This function ensures trouble-free start-up of your equip-
• Control Systems
ment even during a utility power outage.
• Industrial Automation
• Automatic Bypass
• Broadcasting and Telecommunications System
In the event of an overload or a UPS fault, the MX UPS
• Data Centers
automatically transfers the load to utility AC power.
Problems
Operating Modes
The MX UPS protects your equipment against the follow-
• 50/60 Hz frequency converter mode
ing problems:
Lock output frequency at 50Hz or 60Hz to suit power
Power failures, Power sags, Power surges, Under-voltage,
sensitive equipments.
Over-voltage, Electrical line noise, Frequency Variation,
• ECO for energy saving
Switching transient, Harmonic distortion.
It allows UPS to operate in high efficiency up to 98% in
Even when presented with the most severe cases of such
energy- saving ECO mode. In this operation mode, load is
power problems, the MX UPS output remains within a
supplied by the mains. In the event of a mains failure, the
remarkable +/-1% of nominal voltage. This means that
inverter takes over the load and provides supply continu-
your loads always receive steady and clean power regard-
ity to the connected systems.
less of the input condition. In addition, the MX UPS
transfers to back up mode with no break in power,
Redundancy
making it the perfect UPS for running sensitive equip-
ment in a poor power environment. The MX UPS is capable of acting in a parallel configura-
tion which is ideal for redundancy and load-sharing,
Features while maintaining high utilization efficiency at the same
High Performance and Reliability time. Up to four MX UPS units may be connected in
parallel. When connected together, the MX units
• On-line Double-Conversion Technology automatically detect the presence of their neighbors and
This technology guarantees consistent high power coordinate load sharing and protection accordingly. This
quality. Whatever the disturbances on the distribution simple upgrade setup enables you to easily modify your
system are, a pure sinewave is regenerated via AC to DC existing solution whenever your load requirements
to AC double-conversion process. The battery supplies change.
the load with power at all times so that no switching time
is noticed at the output when the input power goes off.
The MX Series power systems can operate in the follow-
• DSP technology ing redundant configurations:
A DSP controller provides an improved and cost-effective
solution with high performance. • Distributed Parallel (Optional): increases power and
• Wide Input Voltage Range redundancy of the supply system whilst controlling costs
Simple Power Upgrade Communications
Simple Power Upgrade Communications
The ability of the MX UPS to operate in parallel configura- The MX UPS is equipped with several communication
The abilitytions
of the MX UPS
makes theto operateofinyour
upgrade parallel configura-
power infrastructure a The MX UPS is equipped
options designedwith several monitoring
to simplify communication and control.
tions makes the upgrade of your power infrastructure
simple procedure. This feature makes your investmenta in options designed to simplify monitoring
These options include the following: and control.
simple procedure. This feature makes your investment
the MX UPS “future-proof” since you do not need to in These options include
• An USB portthe following:
the MX UPS “future-proof”
drastically replace since
your you
powerdo infrastructure
not need to already • An USB port
• An RS-232 port
drasticallyinstalled
replace every
your time
power infrastructure already needs
your power consumption • An RS-232 port
• An SNMP network card slot
installed increase.
every time your power consumption needs • An SNMP• An AS-400card
network cardslot
increase. • An AS-400 card
Ease of Use This diversity of options allows you to choose the
Ease of Use This diversity of optionsmethod
communication allowsmost
yousuitable
to choose theparticular
for your
• Easy installation and integration communication method most suitable for your particular
• Easy installation and integration back-up power installation.
• EPO port (Emergency Power Off) back-up power installation.
• EPO portEPO(Emergency Powerthe
switch allow Off) UPS output receptacles to be Monitoring
EPO switch allow off.
switched theSince
UPS the
output
EPO receptacles to be
shuts down the equipment Monitoring
PCE UPS SYSTEMS Inc. realizes that the efficient manage-
switched immediately,
off. Since the orderly
EPO shuts down theprocedures
shutdown equipment are not PCE UPS SYSTEMS Inc. realizes that the
ment of your assets leads to efficient
immediate manage-
productivity in
immediately, orderly
followed by anyshutdown procedures software.
power management are not The UPS ment of your assets leads to
your organization. Forimmediate
this reason, productivity in
we have equipped the
followed will
by any power
have to be management software.inThe
manually restarted UPSto regain
order your organization. For this reason, we have equipped
MX UPS with several management options, theall designed
will havepower
to betomanually restarted in order to regain
the outlets. MX UPS with severaland management
to simplify accelerate options, all designed
daily monitoring and mainte-
power to the outlets. to simplify and tasks.
accelerate daily monitoring and mainte-
• User-friendly LCD display nance
• User-friendly LCD display nance tasks.
• A Liquid Crystal Display (LCD) provides clear multilin- First, the MX UPS features a Liquid Crystal Display screen
• A Liquid Crystal Display (LCD) provides clear multilin- First, the which
MX UPS featuresclear
a Liquid Crystal Display screen
gual information on various operating parameters. provides multilingual information on operat-
gual information on various operating parameters. which provides clear
ing parameters. multilingual information on operat-
Advanced Battery Care ing parameters.
Advanced Battery Care In addition, the MX UPS is fitted with RS-232 & USB ports
The MX UPS employs unique technologies to increase the In addition,
The MX UPS to the MX UPS
interface is fitted
with with RS-232
a nearby computer & USBfor ports
management
lifeemploys unique technologies to increase the
of the batteries. to interface with a nearby computer for management
life of theThe
batteries. and monitoring purposes.
battery is one of the most important components and monitoring purposes.
The batterythatismake
one ofupthe an most important Power
Uninterruptible components
Supply system, Optionally, the MX UPS may be fitted with an SNMP card
that makeand up the
an Uninterruptible
degree of power Power Supplythat
protection system,
such system Optionally, the MX UPS mayit betofitted
which enables be with an SNMP
remotely card
controlled and
and the degree
providesofispower
closelyprotection
tied to thethat such system
quality of the batteries which enables
monitored over a local area network. Usingand
it to be remotely controlled this feature,
provides installed.
is closelyThis
tiedistoa fact
the quality
that PCEofnever
the batteries
tires of stressing, monitored over a localPCarea network.
one central station mayUsing this feature,
be used to conveniently
installed. and,
This for
is athis
factreason,
that PCEyounever tires find
will only of stressing,
Sealed Lead-Acid one central PC station may be used to conveniently
monitor and control all the PCE UPS units on premises.
and, for this reason,
batteries of you will only
the most find Sealed
superior quality Lead-Acid
as a backup power monitor andIt is control all the
also fitted withPCE UPS units
a relay card onthatpremises.
adds integration to
batteries source
of the most
in oursuperior quality as a backup power
UPS solutions. It is also fitted with a relay card that adds integration to
industrial environment and Building Management
source in our UPS solutions. industrialSystems,
environment and Building Management
In addition, we have equipped the MX Series with the as well as interconnection to IBM AS-400
In addition, we have equipped themonitor
MX Series Systems, machines.
as well as interconnection to IBM AS-400
capability to continuously yourwith
powertheinput and
capabilityoutput
to continuously monitor your power input and machines.
status and operate with extreme efficiency
output status and operate with extreme efficiency The MX UPS is fully compatible with PCE’s suite of
accordingly. Such mechanisms increase the system’s The MX connectivity
UPS is fully solutions
compatible with PCE’s
accordingly. Such mechanisms increase the system’s allowing you tosuite of critical
preserve
battery life by up to 60%. connectivity
battery life by up to 60%. datasolutions
and perform allowing you to
controlled preserveequipment
shutdown critical in the
data and event
perform of controlled shutdown equipment in the
power disturbance.
Some of the advanced battery care features that the MX
Some of the event of power disturbance.
UPSadvanced
employs are battery
listedcare features that the MX
below:
UPS employs are listed below: Secure Power At All Times
Secure Power At All Times
• A wide input voltage acceptance range (up to 35%) Supplying you with a UPS alone will never deliver the
• A wide input voltage acceptance range (up to 35%) Supplyinglevel
you of
withbusiness
a UPS alone will never
• Temperature-compensated battery charger continuity you deliver thePCE UPS
require.
• Temperature-compensated battery charger level of SYSTEMS
business Inc.continuity you require. PCE UPS
bundles its superior products with a range
• Intelligent battery charger SYSTEMSof Inc. bundles its plans
superior products
• Intelligent battery charger maintenance designed to: with a range
• Charge and discharge cycle control of maintenance plans designed to:
• Charge and discharge cycle control • Extend the life of your power protection equipment
• End of discharge voltage compensated with time • Extend the life of ayour power approach
protectiontoequipment
• End of discharge voltage compensated with time • Provide proactive disaster recovery
• Minimum ripple current values • Provide •aEnsure
proactive
the reliability to
approach of disaster
power torecovery
your load
• Minimum ripple current values • Ensure the reliability of power
• Algorithm to calculate battery life expectancy • Optimize your capitalto your load
expenditure
• Algorithm to calculate battery life expectancy • Optimize• Provide
your capital expenditure at a fixed cost
risk management
• Periodic battery testing • Provide risk management at a fixed cost
• Periodic battery testing
• Different options for battery placement Please contact your local PCE sales office or visit our web
• Different options for battery placement Please contact
All these features put together sum up to considerable site atyour local PCE salesfor
www.pceups.com office
moreorinformation.
visit our web
All these features put together sum up to considerable site at www.pceups.com for more information.
savings in your running costs.
savings in your running costs.
MX 31 Series

Model MX 10K 31 MX 15K 31 MX 20K 31


Model Rating 10000VA 15000VA 20000VA
Output Power 9000W 13500W 18000W

Voltage 380V, 400V, 415V (selectable) , 3Ф4wires


Frequency 50/60 Hz +/-10%

Input Voltage range 305-478 VAC @ 100% load; 190-520@50% load


Power Factor >99%
THDi <3%
Voltage (on battery) 220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
Frequency (on battery) 50/60 Hz +/-0.2%
Transfer Time 0 ms
output UPS Design Technology On-Line / Fully digitized microprocessor controlled
Output Wave Form Pure Sinewave
Total Harmonic distortion (THD) < 2% of T.H.D. at linear load, < 5% T.H.D. at non linear load
Crest Factor 3:1
125% for 10 minutes and 150% for 1 minute or 110% for 10min,
Overload Protection
Protection 110~130% for 1 min,>130% for 1 sec
Short Circuit Protection UPS output cut off immediately using input fuse/circuit breaker protection

LED indicators On-line mode, back up mode, CVCF mode, Eco mode, batt. test, fault status
System Display LCD indicators
UPS Status, Load level, Battery level, Input/Output voltage, Discharge time,
and Fault indicators
Battery Type Sealed, maintenance-free lead acid batteries, 3-5 years typical life time
Typical Recharge Time 5 hours to 90% Full capacity
Battery Charging Current 1A 2A
Battery number 20pcs (18 - 20pcs adjustable) 1 20pcs (18 - 20pcs adjustable)1x2 strings
Back up time(1/2 Load) 18 min 25 min 18 min

Battery mode Beep every 4 second


Low battery
Audible Alarm Overload
Beep every second
Beep twice every second
Fault Continuously beeping
2
USB, RS-232, AS-400 Interface with power management software

Communication SNMP 2 Power Management from SNMP manager and web browser
Compatibiltiy Windows 2000/XP/2003/Vista/2008, Windows 7/8, Linux, Unix and MAC
W x D x H mm 250 X 592 x 576 250 x 815 x 826
Physical Net Weight kgs 83 164
AC Mode 92%
Efficiency Battery Mode 89% 90%

Environment Ambient operation Maximum elevation at 3500m, 0 to 40˚C, 0 to 95% humidity (non-condensing)
Audible noise <50dBA at 1 Meter
Performance EN50091-3/IEC 62040-3
Safety UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
Standards & EMC (EMS / EMI)
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A,EN 55022/B,FCC 47 part 15 - Subpart B -
Certifications
Design, production, and services ISO 9001
Environment ISO 14001 certified company
Marking & Certifications CE, TUV/GS, UL, cUL, c-Tick

1 * For optional features


2 * When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.

Windows Server
Windows 10 2008-2012-2016

LFSTS16EN115© 2017 PCE UPS SYSTEMS Inc.


All trademarks are property of their respective owners. Specifications subject to change without notice.

You might also like