You are on page 1of 2

Sri Adichunchanagiri Shikshana Trust (R)

SJB Institute of Technology


(Affiliated to Visvesvaraya Technological University, Belagavi & Approved by AICTE, New Delhi.)
Department of Civil Engineering
INTERNAL ASSESSMENT PAPER
Internal Quiz: III Academic Year: EVEN /2020-21
Sub: Earthquake Resistant Structure Sub-Code: 20CSE23 Sem: 2nd Sem M.Tech
Date: 23-09-2021 Time: 10:00 AM to 10:40 AM Duration: 40min
Internal Quiz max marks: 20 Staff-In charge: Prajwal RP Nadagowda
CO3-Analyze and design Masonry structures against earthquake loading.
CO5-Explain the different seismic retrofitting techniques and. State various control system and disaster management system.
Quiz
SI. CO Ma
Multiple choice question BT
No rks
Determine the force at crack condition ordinary masonry structure of school building.
1 Roof load P=20 kN/m height of wall h=4m width b=0.2m unit weight of wall 20 kN/m3 L1 CO3 2
a) 0.9 kN b) 1.5 kN c) 2 kN d) 3 kN
Determine the displacement of ordinary masonry structure of school building. Roof
2 load P=20 kN/m height of wall h=4m width b=0.2m unit weight of wall W=20 kN/m3 L2 CO3 2
a) 0.160 m b) 0.128 m c) 0.25 m d) 0.0275 m
Determine the equivalent stiffness of ordinary masonry structure of school building.
Roof load P=20 kN/m height of wall h=4m width b=0.2m unit weight of wall W=20
3
kN/m3 L2 CO3 2
a) 9 kN/m b) 14 kN/m c) 7 kN/m d) 15 kN/m
Determine the equivalent natural frequency of ordinary masonry structure of school
building. Roof load P=20 kN/m height of wall h=4m width b=0.2m unit weight of wall L2 CO3 2
4
W=20 kN/m3
a) 0.07 Hz b) 0.09 Hz c) 0.03 Hz d) 0.01 Hz
A wall topples down easily if it is pushed at direction perpendicular to its plane is
5 known as L1 CO3 1
a) In plane resistance b) Out of plane failure c) Shear failure d) None
Shear wall designed to resist in-plane lateral forces, typically wind and seismic loads
6
a) False b) True L1 CO3 1
Calculate design seismic coefficient for a load bearing masonry wall school building
7 which is having time period of 4 sec located in zone 2 on a medium soil L2 CO3 3
a) 0.017 b) 0.007 c) 0.0056 d) 0.01
Check for allowable shear stress from 3 basic condition in a masonry structure if
8 V=40kN, A=20000 mm2, P=300x103 and prism strength is 9 L2 CO3 2
a) 0.4998 b) 0.0056 c) 0.0245 d) 0.0452
The shock absorbers in earthquake resistant building is called
9
a)Base isolator b) Mass damper c) Cross braces d)Flexible pipes L1 CO5 1
Base isolators are made up of
10
a) Rubber b)Steel c)Lead d)All of them L1 CO5 1
The weight places in roof of an earthquake resistant building is called
11
a)Base isolator b)Mass damper c)Cross braces d)flexible pipes L1 CO5 1
Cross braces made of steel in a earthquake resistant building is placed
12
a)In roof b)Between floors c)In base d)In waterlines L1 CO5 1
The measure of earthquake's strength is the
13
a)Intensity b)Consistency c)Magnitude d)Power L1 CO5 1

Signature of Faculty Scrutinizer HOD


Page 1 of 2
Sri Adichunchanagiri Shikshana Trust (R)
SJB Institute of Technology
(Affiliated to Visvesvaraya Technological University, Belagavi & Approved by AICTE, New Delhi.)
Department of Civil Engineering
SCHEME AND SOLUTION
Internal Quiz: III Academic Year: EVEN /2020-21
Sub: Earthquake Resistant Structure Sub-Code: 20CSE23 Sem: 2nd Sem M.Tech
Date: 23-09-2021 Time: 10:00 AM to 10:40 AM Duration: 40min
Internal Quiz max marks: 20 Staff-In charge: Prajwal RP Nadagowda
CO3-Analyze and design Masonry structures against earthquake loading.
CO5-Explain the different seismic retrofitting techniques and. State various control system and disaster
management system.

Question Correct Marks Question Correct Marks


No answer No answer
1 a 2 8 a 2

2 b 2 9 a 1
3 c 2 10 d 1
4 a 2 11 b 1
5 b 1 12 b 1
6 b 1 13 c 1
7 a 3

Signature of Faculty Scrutinizer HOD

Page 2 of 2