You are on page 1of 13

Asian VLF Observation Network

Pontianak station
• Update
– 2010/09/15 Ver. 1.0 F. Tsuchiya
– 2014/02/14 Ver. 1.1 H. Ohya
– 2014/02/20 Ver. 1.2 H. Ohya
– 2014/07/01 Ver. 1.3 H. Ohya
– 2014/11/11 Ver. 1.4 K. Yamashita (replace VLF-E PC)
– 2015/03/25 Ver. 1.5 H. Ohya
– 2015/09/18 Ver. 1.6 H. Ohya
– 2017/03/25 Ver. 1.7 H. Ohya
– 2018/03/20 Ver. 1.8 H. Ohya
– 2019/02/20 Ver. 1.9 H. Ohya
– 2020/01/22 Ver. 1.10 F. Tsuchiya
replace LF-STD PC, update OS of VLF-B PC
replace external HDDs of VLF-E and VLF-B
Contact persons
• LAPAN
– Mr. Timbul Manik (Bandung)
timbulm@bdg.lapan.go.id
timbulm@yahoo.com
timbul@gmail.com
– Mr. Miswari (Pontianak)
Balai Pengamatan Antariksa dan Atmosfer, LAPAN PONTIANAK
JL. 28 OKTOBER, SIANTAR HULU
Pontianak, 78241
Email: miswari@lapan.go.id, Phone No. 081257700519
– Mr. Hadi (Technical staff, Internet etc., Pontianak)
– Mr. Dedi(Technical staff, Pontianak, Non-regular staff)
Email: ddi_lapan@yahoo.co.id
– Mr. Veni (Technical staff, driver, Pontianak)
– Ms. Nia (Junior Engineer, Pontianak) Email:cnia32@gmail.com
– Ms. SURAINA (research staff, Pontianak)
– Mr. Lambang Nurdiansah (Technical staff, Pontianak)
– Mr. Angga Yolanda Putra (Technical staff, Pontianak)
– Mr. Singgih Anggi Purnama (Technical staff, Pontianak)
Contact persons
• AVON Japan
– Prof. Yukhiro Takahashi (Hokkaido Univ.) Project lead
spriteselves@gmail.com
– Dr. Ohya Hiroyo (Chiba Univ.) VLF-B
ohya@faculty.chiba-u.jp
– Dr. Kozo Yamashita (Ashikaga Univ) VLF-E
kozoymst@gmail.com
– Dr. Fuminori Tsuchiya (Tohoku University) LF-STD
tsuchiya@pparc.gp.tohoku.ac.jp
Block Diagram of the VLF
receiving system and
cable connections

Pontianak, Indonesia
Geophysical lat. And lon.: 0.0ºN, 109.4ºE
Installed :Aug.22-26, 2010

All instruments and cables inside the cabin


are labeled as follows
NO.1 Instrument ID
S1 Cable ID
VLF-E/VLF-B
E5 GPS receiver indoor
GPS antenna IRIG-B out
(GPS-605)

NO.2
Tohoku Electronic Industrial
Preamp unit E6 NO.1 Instrument ID
SIG
Loop antenna (NS) DIPOLE E1 Cable ID
OUT
LOOP CH1
Loop antenna (EW) LOOP CH2

Vertical dipole antenna NO.5


NO.3
VLF-E PC 6TB 4TB(LAPAN)
VLF-E is skipped pre- VLF-E BNC
30-m Cable DELL OPTIPLEX 9010
amplifier connector unit
FUSE:1A (CONTEC ATP-16E)
E7
Tohoku Electronic Industrial Ch.0 (AI00)
E1
Main amp unit E2 Ch.1 (AI01)
E8
VLF-E OUT E3 Ch.2 (AI02)
CH1 VLF-B 40kHz OUT1 E4 Ch.3 (AI03) NO.6
CH2 VLF-B 40kHz OUT1

NO.4 VLF-B PC
DELL OPTIPLEX 7020
VLF-B BNC NO.20
CH1 VLF-B 10kHz OUT B1 connector unit
(CONTEC ATP-16E) B3
CH2 VLF-B 10kHz OUT B2
Ch.0 (AI00)
NO.1
Ch.1 (AI01)
NO.7 4TB
Ch.2 (AI02)
LF standard signal (LF-STD)
mono-pole antenna
NO.1 Instrument ID

Co-axial cable S1 Cable ID


5D2V
KIV
(GND-line)

indoor

FUSE:1A NO.11
Desktop PC
NO.9 Tohoku Electronic Industrial LF STD SIG DELL Vostro 220
NO.8 FUSE:100mA
Main amp unit BNC terminal NO.13
S1 (CONTEC, ATP-16E)
S2 indoor S3 S4
Arrester STD SIG IN STD SIG OUT
unit Ch.0 (AI00) S10
GND2 GND Ch.1 (AI01)
GND
GND3
GND1
S9 10MHz 200kHz
TTL OUT S12
TTL in
NO.10
NO.1 S5 NO.13
GPS Receiver S8 NO.14
BNC-T
FURY-10M (SO)
S9 LF STD SIG
10MHz TTL Terminal board
Three metal bars Terminator
in the ground (CONTEC, FTP-15)
1PPS
S7
AI START S11
RS232C AI EXCLK (14, 15)
S6
GPS antenna S13
Gain setting of the Main receiver

Jan. 22 2020
Gain
VLF-E 34dB
VLF-B Ch1 40kHz 99
Ch1 10kHz 99
ATT 0dB
Ch2 40kHz 99
Ch2 10kHz 99
ATT 0dB
LF-STD 1st stage 6dB
2nd stage 0dB
LAN (VPN) & Power supply
LAPAN VPN network Network cable
10.16.150.28
(GW:10.16.150.1) Power line cable
(SM:255.255.255.0)
DNS1 : 10.14.1.10 NO.1 Instrument ID
DNS2 :
network router Remote E1 Cable ID
WAN (Buffalo BHR-4GRV) power controller
IP:10.16.150.28 ID: root (Meikyo Co. Ltd.)
GW:10.16.150.1 PW: (space) (RPC-M5C) AC230V
SM:255.255.255.0 IP:192.168.53.5
NO.18 (from a wall table tap)
HUB One port× ID: admin
PW: projectd
Hub UPS APC
P4 NO.17
AVON-PTK LAN Smart-UPS 1500 NO.15
192.168.53.1 Port 4
FUSE:15A
(GW:192.168.53.1)
(SM:255.255.255.0)
DNS1 : 10.14.1.10 AC tap
DNS2 : VLF-E PC
IP:192.168.53.6
AnyDesk ID: 947 226 566 DELL OPTIPLEX 9010 NO.16 Transformer
Win 10 Pro P1 Port 1
PW: projectd1 output: 100V
TeamViewer ID SANKOSHA
729 777 240 NO.6
Other 1ST1-10299s
PW: projectd
instruments
VLF-B PC
IP:192.168.53.3
NO.7
DELL OPTIPLEX 7020
AnyDesk ID: 126 165 361 Win 10 Pro Port 2
PW: projectd1

LF-STD PC
IP:192.168.53.4 DELL Vostro 220
AnyDesk ID: 967 799 874 Win 10 Pro P3 Port 3
PW: projectd1
NO.13
CPU Switch
CPU SW (CPU changer)
Sanwa AWE-KVM4LU

VLF-E PC Port 1 Port 2 Port 3 Port 4


DELL OPTIPLEX 9010 (NC)

NO.6

VLF-B PC Display, KB, and mouse


DELL OPTIPLEX 7020

NO.7

LF-STD PC
DELL Vostro 220

NO.12

CPU SW (CPU changer)


Sanwa AWE-KVM4LU
How to connect PCs
inside AVON-PKT LAN
• PCs
– TeamViewer ID
• VLF-E : 729 777 240
PW: projectd
– Anydesk ID
– VLF-E : 947 226 566, PW: projectd1
– VLF-B : 126 165 361, PW: projectd1
– LF-STD : 967 799 874, PW: projectd1
• Remote power controller
– http://192.168.53.5/
– ID: admin
– PW: projectd

• Internet router
– http://192.168.53.1/
– ID: root
– PW: (space)
LAPAN server
• Host name
Rdsa.bdg.lapan.go.id
Port:22
• ssh
Username: avonptk
PW: avonptk014
VLF-E VLF-B LF-STD
Vertical electric dipole antenna Crossed magnetic loop antennas Vertical electric monopole antennas
(0-20kHz) (0-40kHz) (10k-100kHz)

* VLF-E system also measures signals from magnetic loop antennas (VLF-B)
Spare of UPS
• We save a UPS (Yuasa THA1000-10) that
Dr. Otsuka (ISEE, Nagoya Univ.) used in
previous time at Pontianak as a spare of
UPS.

You might also like