Operating Instructions 1)

ZR110-132-145-160-200-250-275-300-315-355-400-425-450-500-630-750
With Elektronikon regulator
From serial number AIF-079 599 onwards

BEFORE STARTING

Attention: The operator must apply all relevant safety precautions,


especially those mentioned in the Instruction book. Consult the
Instruction book section “Initial start-up” before starting the compressor
for the first time.

1. The temperature of the intake air must be between 0°C and


40°C.
2. Check the oil level, which must be in the middle of the sight-
glass or in the upper field of the green range.
3. Close the condensate drain valves of the intercooler and
aftercooler.
4. Check that the cooling water drain valves are closed.
5. Open the cooling water inlet valve and outlet valve.
6. Open the air outlet valve.
7. Switch on the voltage and check that voltage on LED (6) lights
up.

STARTING

1. Press start button (1). The compressor starts running in


unloaded condition and automatic operation LED (8) lights up.
2. Approx. 25 seconds later (programmable), the compressor starts
running loaded. 1. Start button
3. Regulate the cooling water flow, if necessary, during loaded 2. Display
operation. 3. Scroll keys
4. Tabulator key to select parameter indicated by a horizontal
arrow
DURING OPERATION
5. Function keys to control and program the compressor
6. Voltage on LED
1. When automatic operation LED (8) is alight, starting and 7. General alarm LED
stopping of the motor is controlled automatically. 8. Automatic operation LED
2. Check the display (2). Regularly press the ¯ key to call up the 9. Stop button
compressor status (pressures, temperatures, etc.). 17. Warning, under tension
3. Remedy the trouble if alarm LED (7) is alight or blinks. If a 18. Read Instruction book before starting compressor
service message appears, carry out the service actions of the 19. Switch off the voltage and depressurise the compressor before
indicated plans or replace the indicated component, and reset the maintenance or repair
relevant timer. 20. Before connecting compressor electrically, consult Instruction
4. To unload the compressor manually, press key “Unload” 2); book for motor rotation direction
press key “Load” 2) to switch the compressor to automatic 21. Torques for bolts
operation again. 22. Consult Instruction book before greasing
23. Switch off the voltage before removing protecting cover inside
electric cubicle
STOPPING
24. Oil gasket, screw on filter and tighten by hand (approx. one half
turn)
1. Press stop button (9). The compressor will run unloaded for a 25. Consult Instruction book before maintenance or repair
few seconds, after which it will stop. 26. Cooling water inlet
2. Close the air outlet valve. 27. Cooling water outlet
3. To stop the compressor in case of emergency, press stop 28. Automatic condensate outlet, intercooler
button (S2). Alarm LED (7) starts blinking. After remedying the 29. Condensate valve, intercooler
trouble, unlock the emergency stop button by pulling it out. 30. Automatic condensate outlet, aftercooler
4. Open the condensate drain valves of the intercooler and 31. Condensate valve, aftercooler
aftercooler.
5. Close the cooling water inlet valve.
6. When freezing temperatures are expected, drain the compressor 1) For full operating and complete maintenance instructions and
cooling water system completely. safety instructions, as well as for location of components,
consult the Instruction book. The "User manual for
LUBRICATION Elektronikon® regulator", Printed Matter No. 2920 1478 0x
deals elaborately with all regulator functions.
2) If this function is not indicated at the bottom of display (2),
Use oil as specified in the instruction book.
press the key <<Menu>> (5) until the function <<Main
Selected oil is: Screen>> appears above key (F1), then press key <<Main
Screen>>.
2002-12
Registration code: APC ZR/ZT110-275 / 38 / 975 and APC ZR300- Printed Matter No. 2920 1479 10
750 / 38 / 985