OPERATING MANUAL FOR ALL IN ONE PRINTER SCALE

Printer Indicator / Table Top Scale


AC POWER SUPPLY:- Requires 230 Volt AC supply.
DC POWER SUPPLY:- Requires 6V battery with 1A to 5A Rating.
TECHNICAL SPECIFICATION:- MCU:- LPC based Cortex M3 32bit ARM microcontroller based design.
ADC:- The mother card uses latest Texas semiconductor based ADS1232, 24 bit delta sigma ADC for higher resolution,
for better accuracy and better linearity. ADC is also has internal crystal so reduce the chance for crystal failure
errors with found in last decade.
1. Supply Voltage:– 230V AC, 50Hz +/- 10%
2. Operating Temperature:– 10 Degree C to 45 Degree C.
3. Humidity: 10% to 95% relative humanity (non condensing).
4. Power consumption: Max 10 watt.
5. Hysteresis:- 0.03% of Rated capacity.
6. Linearity:- 99.9% of the Rated capacity.
FEATURES:- KEYS:-There are 4 keys function in the mother
1. Completely Customizable slip at customer side board.
2. 16 alphanumeric character for Header1 KEY1 - TARE/ENTER
3. 30 alphanumeric character for header2 KEY2 - MODE/INCREMENT
4. 30 alphanumeric character for footer KEY3 - CAL PRESS/SHIFT
5. Two customizable line which can be edited KEY4 - CAL_ENTER / PRINT /
6. Selection of no of copy of each print DECREMENT
7. Select among 24 different print slips
8. 1500 memory for data storing
9. 24 different types of report
10. Linear power supply is used for long life
11. 8 hours of battery back up
12. Piece and liter functions

NAME SETTINGS:- For Firm name setting, allows to enter 18 character alphanumeric name to enter,
Steps:
1. 1st Switch OFF the scale, then Press & hold KEY 2 (MODE/INCREMENT) & switch ON the scale. (To set
Firm/Scale name setting)
2. Display shows “UNLOCK”, release KEY 2 then press KEY 1 (TARE), Display will blank for password entry.
Enter UNLOCK PASS “2900” with the help of KEY 2 (MODE/INCREMENT), KEY 4 (DECREMENT) and
KEY 3 (CAL PRESS/SHIFT) then Press KEY 1 (TARE)
3. Display shows “CHPASS” then Press KEY 1 (TARE), then enter PARAMETER LOCK PASS “CUSTOME” (IF
NEEDED) with the help of KEY 2 (MODE/INCREMENT), KEY 4 (DECREMENT) and KEY 3 (CAL
PRESS/SHIFT) then Press KEY 1 (TARE)
4. Display shows “NAME 1”, then Press KEY 1 (TARE) then display shows old name, enter new names first
6 ALPHA NUMERIC CHARACTERS with the help of KEY 2 (MODE/INCREMENT), KEY 4 (Decrement) and
KEY 3 (CAL PRESS/SHIFT) then Press KEY 1 (TARE) to save name and to enter next 6 digit alphanumeric
name.
5. Repeat step 4 for NAME 2 & NAME 3 settings then Press KEY 1 (TARE) key to save new name & for next
name setting,

1
PRINTER HEADER NAME 1 SETTING:-
6. After name setting done, Press KEY 1 (TARE), Display shows PNAM 1 then Press KEY 1 (TARE) key. (For
Printer header name 1 setting, allows to enter 16 character alphanumeric name)
7. Then display shows old name, enter new name’s first 6 ALPHA NUMERIC CHARACTERS with the help of
KEY 2 (MODE/INCREMENT), KEY 4 (Decrement) and KEY 3 (CAL PRESS/SHIFT), then Press KEY 1
(TARE) key to save the name.
8. Then repeat the step 6 and step 7 for PNAM 2 & PNAM 3 settings. Press KEY 1 (TARE) key to save the
printer Header name 1 settings.
PRINTER HEADER NAME 2 SETTINGS:-
9. After header name 1 setting done, Press KEY 1 (TARE), Display shows PNAM 4 then Press KEY 1 (TARE)
key. (For Printer header name 2 setting, allows to enter 30 character alphanumeric name)
10. Then display shows old name, enter new name’s first 6 ALPHA NUMERIC CHARACTERS with the help of
KEY 2 (MODE/INCREMENT), KEY 4 (Decrement) and KEY 3 (CAL PRESS/SHIFT), then Press KEY 1
(TARE) key to save the name.
11. Then repeat the step 9 and step 10 for PNAM 5 to PNAM 8 settings. Press KEY 1 (TARE) key to save the
printer Header name 2 settings. Display shows,
12. PFEED ‘X’ (SPACE for 5mm SIZE):- This function is use to adjust the space of 5mm after print content.
Where X is the numeric value for space. To set the space after print area Increment the value of paper
feed using KEY 2 (MODE/INCREMENT) and KEY 4 (DECREMENT). Standard PFEED Value for Thermal
Roll is 3 and For Label Roll is 4 then Press KEY 1 (TARE) to store new setting.
13. PFDOT (SPACE for 1mm SIZE):- This function is use to adjust the space of 1mm after print content. To
set the space after print area Press KEY 1 (TARE) then Increment the value of paper feed dot using KEY
2 (MODE/INCREMENT) and KEY 4 (DECREMENT) standard PFDOT Value for Thermal Roll is 0 and For
Label Roll is 48 then Press KEY 1 (TARE) to store new setting.
PARAMETER SETTINGS:-
Steps:
1. 1st Switch OFF the Scale, then Press & hold KEY 3 (CAL PRESS/SHIFT) & switch ON the scale.
2. Display shows “PASS”, release KEY 3 & Press KEY 1 (TARE), then enter PARAMETER LOCK PASS i.e.
“CUSTOM” (Set in Name setting) with the help of KEY 2 (MODE/INCREMENT), KEY 4 (Decrement) and
KEY 3 (CAL PRESS/SHIFT) then Press KEY 1 (TARE). If password is wrong display shows pass then Re-
enter correct password. (Default/Standard Password is “0000”)
3. Display shows “PARMTR” then Press KEY 1 (TARE).
4. Display shows “SER NO” and Press KEY 1 (TARE) then enter the Serial/Bill number from where to start
the Print Serial/Bill Number in Printing slip and Press KEY 1 (TARE).
5. Display shows CS 1/2/3 i.e. capacity selection. Select capacity range as per requirement using KEY 2
(MODE/INCREMENT) (CS 1 for capacity 1, CS 2 for capacity 2 & CS 3 for capacity 3) then Press KEY 1
(TARE).
6. Display shows “CAP 1”, then Press KEY 1 (TARE). Display shows last stored capacity 1, enter new capacity
with the help of KEY 2 (MODE/INCREMENT), KEY 4 (DECREMENT) and KEY 3 (CAL PRESS/SHIFT) and
then Press KEY 1 (TARE) to store new capacity.
7. Display shows “ACC 1” then it shows old accuracy value, for entering new value, increment accuracy
using KEY 2 (MODE/INCREMENT) and Press KEY 1 (TARE),
8. Display shows “DP 1” it shows old decimal point value, for entering new value, increment value using
KEY 2 (MODE/INCREMENT) and Press KEY 1 (TARE).
9. Then repeat Step 6, Step 7 and Step 8 for CAP 2 & CAP 3 settings with its Accuracy and dp settings. And
then Press KEY 1 (TARE). Display shows,
10. AUTO ZERO (AUT 0) SETTING:- Increment the value of auto off/zero tracking value by KEY 2
(MODE/INCREMENT) and Press KEY 1 (TARE). Display shows,
11. MODE SETTINGS:- This function is used for different mode of the weighing, which includes following
different types of the weighing, To select different mode select as per given below,
Mode 0 = To weighing/work in normal i.e. in grams or in kg.
Mode 1 = To weighing/work in Piece counting
Mode 2 = To weighing/work in liter.
Mode 3 = To work in Kg mode with 2 LED indication & Press KEY 1 (TARE). Display shows,
12. DSP SETTING:- This mode is for saving electricity or power. If the all six digit will glow in standby mode
the electricity consumption is more. To save electricity in standby mode,
DSP 0 = Shows all zero. From DP i.e. “0.000”
DSP 1 = To glow single digit (To save electricity). Single zero on screen
DSP 2 = To glow running Decimal Point save more electricity, Press KEY 1 (TARE), Display shows,
13. LITER FACTOR:- Press KEY 1 (TARE). Now display shows older liter factor/value, to enter new liter
factor/value use KEY 2 (MODE/INCREMENT), KEY 4 (DECREMENT) and KEY 3 (CAL PRESS/SHIFT)
then press KEY 1 (TARE) to store new liter value,

2
14. LACC (Liter Accuracy):- Display shows ‘LACC’ then shows older liter accuracy value, to enter new liter
accuracy use KEY 2 (MODE/INCREMENT), KEY 4 (DECREMENT) and KEY 3 (CAL PRESS/SHIFT) then
press KEY 1 (TARE) to store new liter accuracy value, Display shows,
15. STCT (Stable Count):- Display shows old stability count value, enter new stability count value using
KEY 2 (MODE/INCREMENT) and KEY4 (DECREMENT) standard stable count is ‘3’ then Press KEY 1
(TARE) to store new value, Display shows,
16. STTM (Stable Time):- Display shows old stability time value, enter new stable time value using KEY 2
(MODE/INCREMENT) and KEY 4 (DECREMENT) standard stable time is ‘5’ then press KEY 1 (TARE) to
store new value, Display shows,
17. SER NO:- Display shows “SER NO” and Press KEY 1 (TARE) then enter the Serial/Bill number from where
to start the Print Serial/Bill Number in Printing slip and Press KEY 1 (TARE). Display shows,
18. PRNT MODE:- Display shows ‘PRNT’ there is two different mode for print command i.e.
PRNT 0 for Manual Print command and PRNT 1 for Automatic Print (Auto Print) Press KEY 1 (TARE)
19. Parameter setting is complete. To activate dummy zero set capacity as 100000, accuracy 10 and dp 3 for
100 kg / 10 g scale.
CALIBRATION:-Calibration can be done in weighing mode,
Steps:
1. Put the standard weight on the scale, weight should be 1/3 rd of the Full capacity.
2. Then press & hold KEY 3 (CAL PRESS/SHIFT) & Press KEY 4 (CAL ENTER / COUNT). Display shows
“PASS”. Now release KEY 3 & KEY 4 and Press KEY 1 (TARE), then enter PARAMETER LOCK PASS
“CUSTOM” (Set in Name setting) with the help of KEY 2 (MODE/INCREMENT) and KEY 3 (CAL
PRESS/SHIFT) then Press Key 1 (TARE). If password is wrong display shows Pass then Re-enter correct
password & Press Key 1 (TARE).
3. Display shows “CAL” Press KEY 1 (TARE) and display show some count changes with respect to putted
weight then display shows “000000”.
4. Now enter the weight using KEY 2 (MODE/INCREMENT), KEY 4 (DECREMENT) and KEY 3 (CAL
PRESS/SHIFT) then Press KEY 1 (TARE). Calibration is successfully done.

CHANGE IN WEIGHING MODE- To toggle between any two modes, Press KEY 2 (MODE/INCREMENT) to change
in different weighing mode. Again press KEY 2 (MODE/INCREMENT) for previous weighing mode.
ENTER COUNT VALUE:- To enter the piece value first set the piece counting mode by changing weighing mode
into piece counting using KEY 2 (MODE). In piece counting mode display shows “P”. Now press KEY 1 (TARE). Put
counted Pieces on scale pan then PRESS KEY 3 (CAL PRESS/SHIFT) key and hold for 10 seconds displays shows
“SETPCS” and then “000000”. Now enter number of pieces putted on scale pan with the help of KEY 2
(MODE/INCREMENT), KEY 4 (DECREMENT) and KEY 3 (CAL PRESS / SHIFT) then Press KEY 1 (TARE), to store
piece counting value now display shows no of pieces you entered.
DISPLAY INTERNAL COUNT:- For displaying internal ADC count. 1 st Switch OFF the Scale, then Press & hold
KEY 4 (CAL_ ENTER/PRINT/DECREMENT) & switch on the scale. Then Release the KEY display show internal
ADC COUNTS. To exits from counts Press KEY 2 (MODE/INCREMENT).

PRINTER SLIP SETTING:- Basic/Standard Printing slip

Print Slip with filled name- 1st Switch off the scale then Press & hold both KEY 1 (TARE) and KEY 2 (MODE)
together and switch ON the scale.
1. Display shows “PASS”, release KEY 3 & press KEY 1 (TARE), then enter PARAMETER LOCK PASS i.e.
“CUSTOM” (Set in Name setting) with the help of KEY 2 (MODE/INCREMENT), KEY 4 (Decrement) and
KEY 3 (CAL PRESS/SHIFT) then Press KEY 1 (TARE). If password is wrong display shows pass then Re-
enter correct password. (Default/Standard Password is “0000”)

3
2. Display Shows STPRT (Printing Slip Setting), Press KEY 1 (TARE), display shows,
3. SFMT (Slip Format):- Display shows old slip format selected, to change slip format change below setting
using KEY 2 (MODE/INCREMENT) and KEY 4 (DECREMENT) then press KEY 1 (TARE), Display shows,
SFMT 0 - To Print Header 1, Header 2, Date, Time and Weight i.e.,

SFMT 1 - To Print Header 1, Header 2, Bill/Serial no., Date, Time and Weight i.e.,

SFMT 2 - To Print Header 1, Header 2, Bill/Serial no., Date, Time, Gross Weight, Net weight
and Tare weight i.e.,

SFMT 3 - To Print Header 1, Header 2, Bill/Serial no., Date, Time, Weight, Quantity/Liter i.e.,

SFMT 4 - To Print Header 1, Header 2, Bill/Serial no., Date, Time, Serial No. and correspondence
Weighments with Total weight i.e.,

4. H1:- This function is use to Print HEADER 1 or not. To set Header 1 make H1 value as below,
H1 0 to Print Slip without Header 1
H1 1 to Print Slip with Header 1 then Press KEY 1 (TARE) to store new value, Display shows,
5. H2:- This function is use to Print HEADER 2 or not. To set Header 2 make H2 value as below,
H2 0 to Print Slip without Header 2
H2 1 to Print Slip with Header 2 then Press KEY 1 (TARE) to store new value, Display shows,
6. STR1:- This function is use to Print Star/Dash Line or not. To separate Header make STR 1 value as
below,
STR1 0 to Print Slip without Star/Dash Line
STR1 1 to Print Slip with Star/Dash Line then Press KEY 1 (TARE) to store new value, Display
shows,
7. STR2:- This function is use to Print Star/Dash Line or not. To separate Footer make STR 2 value as
below,
STR2 0 to Print Slip without Star/Dash Line

4
STR2 1 to Print Slip with Star/Dash Line then Press KEY 1 (TARE) to store new value, Display
shows,
8. DTSH:- This function is use to Print Date or not. To set date make DTSH value as below,
DTSH 0 to Print Slip without Date
DTSH 1 to Print Slip with Date then Press KEY 1 (TARE) to store new value, Display shows,
9. TMSH:- This function is use to Print Time or not. To set time make TMSH value as below,
TMSH 0 to Print Slip without Time
TMSH 1 to Print Slip with Time then Press KEY 1 (TARE) to store new value, Display shows,
10. H1BLD:- This function is use to Print Header 1 in BOLD or not. To set bold make H1BLD value as below,
H1BLD 0 to Print Header 1 without Bold if selected Header 1
H1BLD 1 to Print Header 1 with Bold if selected Header 1 then Press KEY 1 (TARE) to store
new value, Display shows,
11. SERPN:- This function is use to Print Serial number or not. To set Serial no. make SERPN value as below,
SERPN 0 to Print Slip without Serial number
SERPN 1 to Print Slip with Serial number then Press KEY 1 (TARE) to store new value, Display
shows,
12. STDS:- This function is use to Print Dash/Star/Double Dash Line or not. To set Line make STDS value
as below,
STDS 0 to Print ---------- Dash Line to separate Header and Footer
STDS 1 to Print ******** Star Line to separate Header and Footer
STDS 2 to Print ===== Double Dash Line to separate Header and Footer then Press KEY 1
(TARE) to store new value, Display shows,

13. PBAR:- This function is use to Print Barcode or not. To set Barcode make PBAR value as below,
PBAR 0 to Print Slip without Barcode
PBAR 1 to Print Slip with Barcode then Press KEY 1 (TARE) to store new value, Display shows,
14. COPY:- This function is use to Print same slip copy more than 1 or not. To print same type of slip make
COPY value ‘X’ using KEY 2 (MODE?INCREMENT)
Where X is a number of copy value i.e. 0 to 9. It X time prints when given print command.
NOTE: COPY function is not worked in STFM 4 i.e. for partial weighments.
15. BILL:- This function is use to Print Bill/Serial number or not. To set Bill/Serial no. make BILL value as
below,
BILL 0 to Print Slip with Bill number
BILL 1 to Print Slip with Serial number then Press KEY 1 (TARE) to store new value, Display
shows,
16. PKg:- This function is use to Print Kg or not. To set Kg make PKg value as below,
PKg 0 to Print Slip without Kg at weight
PKg 1 to Print Slip with Kg then Press KEY 1 (TARE) to store new value, Display shows,
PKg 2 to Print Slip with gm then Press KEY 1 (TARE) to store new value, Display shows,

17. FOOT:- This function is use to Print Footer or not. To set Footer make FOOT value as below,
FOOT 0 to Print Slip without Footer
FOOT 1 to Print Slip with Footer then Press KEY 1 (TARE) to store new value, Display shows,
a) If footer is selected 1, then Display shows FOOT1 Press KEY 1 (TARE), enter new character of
footer using KEY 2 (ICREMENT), KEY4 (DECRMENT) and KEY3 (SHIFT) then Press KEY 1 (TARE)
for storing.
b) Repeat Step (a) for FOOT 2 to FOOT 5 and then Press KEY 1 (TARE). (30 Characters)
18. LIN1:- This function is use to Print Custom Line 1 or not. To set Custom Line 1 make LIN1 value as
below,
LIN1 0 to Print Slip without Custom Line 1
LIN1 1 to Print Slip with Custom Line 1 then Press KEY 1 (TARE) to store new value, Display
shows,
a) If LIN1 is selected 1, then Display shows L1 Press KEY 1 (TARE), enter new character of Line
1 using KEY 2 (ICREMENT), KEY4 (DECRMENT) and KEY3 (SHIFT) then Press KEY 1 (TARE) for
storing.
b) Repeat Step (a) for L 2 to L 5 and then Press KEY 1 (TARE). (30 Characters)
NOTE: L1 1 and L1 2 total 11 character placed at left side of colon ‘:’ and L1 3 to L1 5 is printed right
side of colon ‘:’ in slip.
EG: PROD NAME : WEIGHT SCALE can be entered as
L1 1: PROD N
L1 2: AME
L1 3: WEIGHT
L1 4: SCALE
L1 5: then Press KEY 1 (TARE)
19. LIN2:- This function is use to Print Custom Line 2 or not. To set Custom Line 2 make LIN2 value as
below,

5
LIN2 0 to Print Slip without Custom Line 2
LIN2 1 to Print Slip with Custom Line 2 then Press KEY 1 (TARE) to store new value, Display
shows,
a) If LIN2 is selected 1, then Display shows L1 Press KEY 1 (TARE), enter new character of Line
1 using KEY 2 (ICREMENT), KEY4 (DECRMENT) and KEY3 (SHIFT) then Press KEY 1 (TARE) for
storing.
b) Repeat Step (a) for L 2 to L 5 and then Press KEY 1 (TARE). (30 Characters)
NOTE: L1 1 and L1 2 total 11 character placed at left side of colon ‘:’ and L1 3 to L1 5 is printed right
side of colon ‘:’ in slip.
EG: MAKE: ABCDEFGH can be entered as
L1 1: MAKE
L1 2:
L1 3: ABCDEF
L1 4: GH
L1 5: then Press KEY 1 (TARE)
20. PZERO:- This function is use to Print Slip at without load or not. To set Slip make PZERO value as
below,
PZERO 0 to Print Slip at without Load
PZERO 1 to Print Slip when only Load then Press KEY 1 (TARE) to store new value, Display
shows,
21. PWTON:- This function is use to Print Weight or not. To set weight make PWTON value as below,
PWTON 0 to Print Slip with Weight
PWTON 1 to Print Slip without weight then Press KEY 1 (TARE) to store new value, Display
shows,
22. WTHT:- This function is use to adjust size of printed weight. To set font size make WTHT value as below,
WTHT 0 to Print weight size with normal size font
WTHT 1 to Print weight size with Small size Big font
WTHT 2 to Print weight size with Medium size Big font
WTHT 3 to Print weight size with Large size Big font then Press KEY 1 (TARE) to store new
value, Display shows,
23. WTWD:- This function is use to adjust width of printed weight. To set font width make WTWD value as
below,
WTWD 0 to Print weight width with normal width font
WTWD 1 to Print weight width with Small width Big font
WTWD 2 to Print weight width with Medium width Big font
WTWD 3 to Print weight width with Large width Big font then Press KEY 1 (TARE) to store new
value, Display shows,
LINE EDITING:- To edit line, in weighing mode Press & Hold KEY 2 (MODE) till display shows,
LIN1:- This function is use to Print Custom Line 1 or not. To set Custom Line 1 make LIN1 value as below,
LIN1 0 to Print Slip without Custom Line 1
LIN1 1 to Print Slip with Custom Line 1 then Press KEY 1 (TARE) to store new value, Display shows,
a) If LIN1 is selected 1, then Display shows L1 Press KEY 1 (TARE), enter new character of Line 1 using KEY 2
(ICREMENT), KEY4 (DECRMENT) and KEY3 (SHIFT) then Press KEY 1 (TARE) for storing.
b) Repeat Step (a) for L 2 to L 5 and then Press KEY 1 (TARE) (30 Characters) then Press KEY 1 (TARE), display
shows,
LIN2:- This function is use to Print Custom Line 2 or not. To set Custom Line 2 make LIN2 value as below,
LIN2 0 to Print Slip without Custom Line 2
LIN2 1 to Print Slip with Custom Line 2 then Press KEY 1 (TARE) to store new value, Display shows,
a) If LIN2 is selected 1, then Display shows L1 Press KEY 1 (TARE), enter new character of Line 1 using KEY 2
(ICREMENT), KEY4 (DECRMENT) and KEY3 (SHIFT) then Press KEY 1 (TARE) for storing.
b) Repeat Step (a) for L 2 to L 5 and then Press KEY 1 (TARE). (30 Characters)
DATE AND TIME SETTING:- 1st switch off the scale then Press & Hold both KEY 3 (CAL PRESS/SHIFT) and KEY
4 (CAL_ENT/DEC) and switch on the scale.
1. Display Shows DATSET, Press KEY1 (TARE), display shows,
2. HOUR:- Press KEY 1 (TARE). Display shows “00”, enter current hour (In 24 Hours format) value
using KEY 2 (MODE/INCREMENT), KEY4 (DECREMENT) and KEY3 (SHIFT) then press KEY 1 (TARE) to
store hour setting and display shows,
3. MIN:- Press KEY 1 (TARE). Display shows “00”, enter current minute value using KEY 2
(MODE/INCREMENT), KEY4 (DECREMENT) and KEY3 (SHIFT) then press KEY 1 (TARE) to store min
setting and display shows,

6
4. DATE:- Press KEY 1 (TARE). Display shows “00”, enter current date value using KEY 2
(MODE/INCREMENT), KEY4 (DECREMENT) and KEY3 (SHIFT) then press KEY1 (TARE) to store date
setting and display shows,
5. MON:- Press KEY 1 (TARE). Display shows “00”, enter current month value using KEY 2
(MODE/INCREMENT), KEY4 (DECREMENT) and KEY3 (SHIFT) then press KEY 1 (TARE) to store month
setting and display shows,
6. YEAR:- Press KEY 1 (TARE). Display shows “00”, enter current year value using KEY 2
(MODE/INCREMENT), KEY4 (DECREMENT) and KEY3 (SHIFT) then press KEY 1 (TARE) to store year
setting. Scale is in normal weighing mode.
REPORT PRINTING:-
For Transfer Data to Pendrive connect pendrive in USB Port First. (Note: Make Sure that pen drive is FAT
FORMATTED, you can see type of pendrive format by connecting pendrive to computer, right click on pendrive and click
on properties. And check file system in general tab, you find FAT16 or FAT32 if not format the pendrive with this file
system FAT32).

1st switch off scale then Press & Hold KEY 1 (TARE) and switch ON the Scale,
Display will shows “PASS “, Press KEY1 and Enter User password with help of KEY2 and KEY3 and
Press Enter(KEY1).
Display Shows USB X, Where X =0/1,
Select 1 by KEY2 & ENTER (KEY1). If you want to transfer data on to pendrive. It will print operation on
display as well as printed message on printer. It will shows create,write and then percentage completed
once it will reach 100, it will show complete and done message. Pendrive data completed remove pendrive
and open the file in computer. File is created With LOGDATETIME format.

Select 0 by KEY2 & ENTER (KEY1). If you don’t want to transfer data on to pendrive and take printout
of reports, follow below steps.

1. RTYPE:- Enter require report settings i.e. depending on mode of weighing as below format using KEY 2
(MODE/INCREMENT) and KEY 4 (DECREMENT) then Press KEY 1 (TARE) to store new report format
value and display shows,
2. RPT:- Enter require report settings i.e. depending on type of slip weighing as below format using KEY 2
(MODE/INCREMENT) and KEY 4 (DECREMENT) then Press KEY 1 (TARE) to store new report type value
and display shows
A) RTYPE 0 – SERIAL NO and WEIGHT Print in report
RPT- 0 all serial no wise report RPT- 1 DATE wise report

RTYPE = 0 & RPT = 0 RTYPE = 0 & RPT = 1

RPT- 2 SINGLE SERIAL No wise report RPT- 3 SERIAL NO RANGE wise report,

RTYPE = 0 RPT = 2 RTYPE = 0 RPT = 3


RPT-4 PRODUCT wise report if customer added in customize line1

B) RTYPE 1 – SERIAL No GROSS WEIGHT, TARE WEIGHT and NET WEIGHT Print in report
RTYPE = 1 & RPT = 0, (To obtain different report change RPT value using KEY 2 (Increment)
RPT- 0 Serial no wise report
RPT- 1 DATE wise report
RPT- 2 Single/Specific Serial no. wise report
RPT- 3 SERIAL NO.s RANGE wise report,
RPT- 4 PRODUCT wise report if customer added in customize line1

7
C) RTYPE 2 – SERIAL NO, WEIGHT, QUANTITY OR LITER (As per MODE value) Print in report

RTYPE = 2 & RPT = 0, (To obtain different report change RPT value using KEY 2 (Increment)
RPT- 0 Serial no. wise report
RPT- 1 DATE wise report
RPT- 2 Single/Specific Serial no. wise report
RPT- 3 SERIAL NO.s RANGE wise report,
RPT- 4 PRODUCT wise report if customer added in customize line1

D) RTYPE 3 – SERIAL NO., DATE, TIME and WEIGHT Print in report

RTYPE = 3 & RPT = 0, (To obtain different report change RPT value using KEY 2 (Increment)
RPT- 0 Serial no wise report
RPT- 1 DATE wise report
RPT- 2 Single/Specific Serial no. wise report
RPT- 3 Serial No.s RANGE wise report,
RPT- 4 PRODUCT wise report if customer added in customize line1

E) RTYPE 4 – SERIAL NO., NO. OF ITEMS and WEIGHT Print in report

RTYPE = 4 & RPT = 0, (To obtain different report change RPT value using KEY 2 (Increment)
RPT- 0 Serial no wise report
RPT- 1 DATE wise report
RPT- 2 Single/Specific Serial no. wise report
RPT- 3 Serial Nos RANGE wise report,
RPT- 4 PRODUCT wise report if customer added in customize line1

PRINT COMMAND:- To Print slip Press KEY 4 (CAL_ENTER / PRINT / DECREMENT). 1

CLEAR DATA: Clear of data can be done by 2 ways,


1. In normal running mode press and hold KEY1 for 20 seconds it will show “PASS “press KEY1,
Enter USER PASSWORD with help of KEY2 & KEY3. Once enter press KEY1. It will show message
“CLEAR “and then “DONE” data wipe out and serial no will start from 1.
2. It can also done by going into parameter setting and setting “SERIAL “as “000000”