CN1 SIEMENS 810 COMMISSIONING

FOR FIELD PC-----BEFORE S/N 2839


-----------------
1.TURN OFF THE CONTROL AND WAIT ABOUT 5 SECONDS.
2.PRESS THE SERVICE / DIAGNOSIS KEY AND TURN ON THE CONTROL
AT THE SAME TIME.HOLD THE KEY DOWN UNTIL THE DISPLAY
APPEARS.
3.PRESS THE COMM. INITIAL SOFT KEY.
4.PRESS THE CLEAR NC COMM. SOFTKEY.
5.PRESS THE CLEAR PLC COMM. SOFT KEY.
6.PRESS THE "^" KEY. also press PLC INITIAL and CLEAR FLAGS
7.PRESS THE NC INITIAL SOFT KEY.
8.PRESS THE FORMATE USER M. SOFT KEY.
9.PRESS THE "^" KEY.
10.PRESS THE DATA-IN OUT SOFT KEY.
11.CONNECT THE CABLE AND SET THE BAUDRATE:
PARAMETER VALUE
5011 11000100
5013 11000100
5016 00001000
12. PRESS ENTER TO STORE THE VALUES
NOTE:A HIGHER BAUDRATE MAY CAUSE A BUFFER OVERFLOW ALARM

13.PRESS THE DATA-IN SOFT KEY.


14.PRESS "1" AND THEN PRESS ENTER WORD TO ENTER 1 IN AS THE
INTERFACE -NO. FOR DATA IN.

15.ON THE PC :
A.SELECT SEREDAT
B.PRESS ENTER
C.FOLLOW THE SCREEN INSTRUCTIONS :
1.SET COMMUNICATIONS: COM PORT = 1 BAUDRATE =1200
PARITY =EVEN DATA BITS = 7 STOP BITS = 2
2.SELECT HARDWARE
3.SELECT ASCII ,SELECT RUN
4.SELECT THE SUB DIR CN1
6.PRESS ENTER TO SEND FILE

*** press the START soft key on the control DIO will appear on the CRT

7.TYPE FILE NAME:: CN1PAR.13A PRESS ENTER


8.PRESS ENTER

16. THE CONTROL "DESTINATION:" WILL SHOW TEA1. NEAR THE END IT WILL SHOW
TEA2 AND LAST SEA.

17.ON THE PC PRESS "ENTER"AFTER THE LOAD

18.PRESS THE STOP SOFT KEY ON THE CONTROL

19.PRESS THE "^" KEY TWICE AND THEN PRESS THE "SET UP END
PW" KEY

20.THE CRT WILL BLANK OUT ABOUT 10 SECONDS.


NOTE : DO STEPS 21 THRU 38 ONLY IF UPDATING THE PLC PROG
AND MESSAGES.

21.PRESS THE SERVICE / DIAGNOSIS KEY.WHEN THE JOG MODE


APPEARS , TYPE 1111 PRESS ENTER.
22.PRESS THE SERVICE/DIAGNOSIS KEY ,THEN PRESS THE INITIAL
CLEAR SOFT KEY.
23.THE CRT WILL BLANK OUT ABOUT 10 SECONDS.
24.PRESS THE PLC INITIAL SOFT KEY.
25.PRESS THE CLEAR PLC SOFT KEY.
26.PRESS THE "^" KEY.
27.PRESS THE NC INITIAL SOFT KEY.
28.PRESS THE SOFT KEYS: FORMAT ALM-TEXT AND CLEAR PART
PROGRAM.
NOTE:PART PROGRAMS WILL BE LOST
29.PRESS THE "^" KEY.
30.PRESS THE DATA-IN-OUT SOFT KEY.
31.PRESS THE DATA IN SOFT KEY.
31.A. PRESS THE START SOFT KEY ( DIO WILL APPEAR)
32.ON THE PC , TYPE THE FILENAME: CN1PLC.12A PRESS ENTER
PRESS ENTER
33. THE CONTROL "DESTINATION:" WILL SHOW PCA AND THEN PCP DURING THE
SECOND AND THIRD SECTIONS.
34.PRESS ENTER ON THE PC AFTER THE LOAD.
35.PRESS THE STOP SOFT KEY.
36.PRESSTHE "^" KEY TWICE.
37.PRESS THE SET UP END PW SOFT KEY.
38.THE CRT WILL BLANK OUT ABOUT 10 SECONDS, THE THE MACHINE
WILL POWER UP IN THE NORMAL STATE.
39.PRESS THE SOFT KEYS SETTING DATA ,THEN PRESS COMMON
-AXIAL .
MOVE THE CURSOR TO THE AXIS - HPG SECTION, ENTER 1 IN
BOTH THE X AND Z VALUES.
40.PRESS THE DATA-IN-OUT SOFT KEY.
41.ON THE PC,TYPE THE FILENAME: CN1L998.999
42.PRESS DATA-IN-START ON THE CONTROL (DIO WILL APPEAR)
43.PRESS ENTER ON THE PC PRESS ENTER TO SEND
44.L998 AND THEN L999 WILL APPEAR ON THE CONTROL
"DESTINATION:"
45.PRESS THE STOP SOFT KEY
46.PRESS THE MODE SELECT KEY AND THEN PRESS THE REPOS. SOFT
KEY.
47.PRESS THE CYCLE STOP AND THE SPINDLE OFF KEYS AT THE SAME
TIME.
48.PRESS THE MODE SELECT KEY AND THEN THE AUTOMATIC SOFT
KEY.
49.PRESS THE PART-PROGRAM SOFT KEY.
50.PRESS THE DIRECTORY SOFT KEY.

51.PRESS SUB-PROGRAM SOFT KEY.


52.ENTER L998 ,THEN PRESS THE LOCK SOFT KEY.
53.ENTER L999 ,THEN PRESS THE LOCK SOFT KEY.
54.PRESS THE MODE SELECT KEY AND THEN PRESS THE REPOS. SOFT
KEY.
55.PRESS THE FEEDHOLD AND THE +Z KEYS AT THE SAME TIME.

CAUTION: TURN OFF THE AIR PRESSURE AT THE BAR FEED


BEFORE NEXT STEP.

56.RESET E-STOP,SELECT JOG MODE ,PRESS FEED ON AND HOME THE


AXIS.
57.PRESS THE ALARM ACKNOWLEDGED KEY TO CLEAR ALARMS.
58.PRESS THE MODE SELECT KEY.
59.PRESS MDI MODE SOFT KEY. ENTER: M3 S0 LF
PRESS CYCLE START
60.PRESS THE SERVICE/DIAGNOSIS KEY ,TYPE 1111 ,PRESS ENTER
61.PRESS THE DIAGNOSIS SOFT KEY ,THEN PRESS ">" KEY.
62.PRESS THE NC COMM SOFT KEY , THEN PRESS THE SPINDLE DATA
SOFT KEY . MOVE THE CURSOR TO 4010. ENTER A VALUE INTO
THIS PARAMETER TO COMPENSATE FOR THE SPINDLE DRIFT.THE
DRIFT MAY BE FINE TUNED AT THE DRIVE.
63.PRESS THE AXIAL DATA SOFT KEY . TYPE: 2720 ,PRESS THE
SEARCH KEY.MOVE THE CURSOR TO 2720 AND THEN PRESS THE
ALTER WORD KEY.PRESS THE ALTER WORD KEY AGAIN WHEN THE
CURSOR IS ON 2721 ( DRIFT COMP )
64. TURN OFF THE CONTROL ,WAIT 5 SECONDS ,AND THEN TURN ON
THE CONTROL
65.SET CUSTOMER OPTIONS: LOB-2031
A.PRESS DIAGNOSIS/SERVICE KEY , TYPE 1111 ,PRESS
ENTER.
B.PRESS DIAGNOSIS SOFT KEY
C.PRESS ">" KEY
D.PRESS PLC COMM SOFT KEY
E.PRESS USER BITS SOFT KEY
F.ENTER A " 1 " IN THE BIT LOCATION

USER BITS PARAMETER 3000


CHIP CONVEYOR 3000.0
PART CHUTE 3000.1
VERTICAL SLIDE 3000.2
AIR BARFEED 3000.3
CLOSER BARFEED 3000.4
HYDRAULIC BARFEED 3000.5
ROBOT 3000.6

EXAMPLE: 3000 00000110 =PART CHUTE & VERTICAL


SLIDE ACTIVE