You are on page 1of 1

REV

JOB NO. :
PROCESS DATASHEET
DOC. NO. :
00A
METERING SYSTEM
TURNKEY EPC DATE BY CHKD APVD
PROJECT 31-Jul-17
1
2 Flow Meter/Metering Process Data List
3
4 Tag No. : MPF-PK-001 A/B Client: PT PERTAMINA (PERSERO)
5 Design Configuration : 2 x 100% PT PERUSAHAAN GAS NEGARA (PERSERO) Tbk
6 INTERNATIONAL POWER Ltd
7 Service: Gas Metering Package Plant Location: Mobile PP Flores
8 P & ID No. : KIT-MPF-PRO-PID-007 Meter Type (proposed): Senior Orifice (note 2)
9 Calculation Ref. : Function (Indicator/Control/Transmit):
10 Line No. :
11 Service Description: Natural Gas Metering Package
12 OPERATING CASE:
13 Process Fluid Natural Gas
14 Phase Gas
15 Minimum Normal Maximum
16 (Note 7)
17 Flow rate (Vol.) Lean LNG MMscfd 0.922 2.304 3.84
18 Rich LNG MMscfd 0.922 2.304 3.84
19 Flow rate (Mass) Lean LNG lb/h 1681 4202 7003
20 Rich LNG lb/h 1812 4529 7549
21 Temperature (Op) °F / °C 41 / 5 41 / 5 41 / 5
22 Pressure (Op) psig / barg 116,03 / 8 145,04 / 10 145,04 / 10
23
24 FLUID PROPERTIES: Lean LNG Rich LNG
25 Operating Pressure Range barg 8 - 10 8 - 10
26 Fluid Viscosity cP 0,01073 - 0,01077 0,01065 - 0,0107
27 Fluid Density lb/ft3 0,415 - 0,51 0,449 - 0,553
28 Molecular weight (Vapour) 16.61 17.90
29 Compressibility factor (Z) (Vapour) 0,973 - 0,968 0,969 - 0,962
30 Specific heat ratio (Vapour) (Cp / Cv) 1,264 - 1,344 1,322 - 1,331
31 Partice size (max) (VTA) µm 30 30
32
33
34 COMPOSITION : Lean LNG Rich LNG
35 Methane mole fraction 0.968500 0.918000
36 Ethane mole fraction 0.021500 0.043400
37 Propane mole fraction 0.005000 0.026700
38 n-Butane mole fraction 0.001100 0.006100
39 i-Butane mole fraction 0.000900 0.005700
40 n-Pentane mole fraction 0.000000 0.000000
41 i-Pentane mole fraction 0.000100 0.000100
42 Nitrogen mole fraction 0.002900 0.000000
43 Oxygen mole fraction 0.000000 0.000000
44 CO2 mole fraction 0.000000 0.000000
45 Total mole fraction 1.000000 1.000000
46 DESIGN DATA :
47 Design Temperature °F / °C 122 / 50
48 Design Pressure psig / barg 319.08 / 22
49 Max Pressure Drop (VTA) psi / barg 3.6 / 0.25
50 EQUIPMENT :
51 The metering skid is equipped with minimum following equipments, but not limited to: (note 1, 6)
52 - 2 x 100% Senior Orifice (note 2, 3, 5)
53 - 2 x 100% Temperature & Pressure Transmitter
54 - 2 x 100% Flow Straightener vanes
55 - 1 x 100% Gas Chromatograph (note 4)
56
57 Inlet connection size : 4"
58 Out connection size : 4"
59 Pipe size internal skid : VTA
60 NOTES:
61
62 1 The design shall be based on N+ 1 independent lines with full redundancy, meaning that N lines are required to ensure to measurement of the total flow in all process conditions. One
63 supplementary line is provided for failure cases or maintenance cases. One flow computer is provided by metering line in case the redundancy of flow computer is not required. The number of
64 line N is determined in accordance with the minimum flow at highest pressure and maximum flow at lowest pressure.
65 2 According to minimum functional specification document, senior orifice type shall be used complete with realtime flow computer and digital recording equipment. The line configuration shall also
66 be realised according to particular requirements of the parties to the gas measurement contract (possibility to use flow meters in series permanently of temporarily, etc.)
67
68 3 The flow measurement systems shall be designed, built, installed and validated in accordance with ISO 5167, ISO 9951, ISO 12765 and ISO 5168. The gas compressibility factors must be
69 calculated according to ISO 12213-2 Natural Gas - Calculation of compression factor - Calculation using molar-composition analysis. AGA 8 and simplified GERG method shall also be
70 available in the flow computer. Change of method can be performed by configuration.
71 4 The gas chromatograph shall be designed according ISO 6568 - Natural gas - Simple analysis by gas chromatography - Analysis up to C6.+ Its performance shall be checked according to ISO
72 10723 (1995) "Natural Gas - Performance evaluation for on-line analytical systems".
73 5 The measurement system shall have the ability to calculate the mass flow, the energy flow, the gas density in standard conditions (ISO 6976) and in line conditions, the calorific value and the
74 Wobble index (ISO 12213, AGA 8, GERG) of the gas conveyed to the specified level of accuracy and over a range of turndown flow rates.
75 6 The metering facilities shall be interfaced via a serial link to the Process Control System and/or to the SCADA, etc. that provides information in the Plant Control Room, the SCADA Control
76 Room, etc.
77 7 Minimum capacity is assumed 40% of normal capacity.
78