Professional Documents
Culture Documents
Operation Manual: FP+ Series
Operation Manual: FP+ Series
FP+ Series:
Rev. 1.0.8
Item no. OM-FP+
1 IMPORTANT SAFETY INSTRUCTIONS
Before using the device, be sure to carefully read the Safety Instructions. Keep this document with the device at all times
1. Read these instructions. To prevent electric shock do not remove top or bottom covers.
2. Keep these instructions No user serviceable parts inside. refer servicing to qualified
3. Heed all warnings. service personnel.
4. Follow all instructions. Français: à prévenir le choc électrique n’enlevez pas les couvercles.
5. Do not use this apparatus near water. Il n’y a pas des parties serviceable à l’intérieur. tous reparations
6. Clean only with a dry cloth.
doit etre faire par personnel qualifié seulment.
7. Do not block any ventilation openings. Install in accordance
with the manufacturer’s instructions. To completely disconnect this equipment from the ac mains,
8. Do not install near any heat sources such as radiators, heat disconnect the power supply cord plug from the ac receptacle.
registers, stoves, or other apparatus (including amplifiers) that the mains plug of the power supply cord shall remain readily
produce heat. operable.
9. Do not defeat the safety purpose of the polarized or grounding- Français: Pour démonter complètement l’équipement de
type plug. A polarized plug has two blades with one wider
than the other. A grounding-type plug has two blades and l’alimentation générale, démonter le câble d’alimentation de son
a third grounding prong. The wide blade or the third prong réceptacle. la prise d’alimentation restera aisément fonctionnelle.
is provided for your safety. If the provided plug does not fit
into your outlet, consult an electrician for replacement of the
10.
obsolete outlet.
Protect the power cord from being walked on or pinched, 1.2 Standards
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
11. Only use attachments/accessories specified by the This equipment conforms to the requirements
manufacturer. of the EMC Directive 2004/108/EC and the
12. Use only with a cart, stand, tripod, bracket, or table specified
by the manufacturer, or sold with the apparatus. When a requirements of the Low Voltage Directive
cart is used, use caution when moving the cart/apparatus 2006/95/EC.
combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused Standards applied: EMC Emission
for long periods of time. EN55103-1, E3
14. Refer all servicing to qualified service personnel. Servicing EMC Immunity EN55103-2, E3, with S/N
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid below 1% at normal operation level.
has been spilled or objects have fallen into the apparatus, the Electrical Safety EN60065, Class I
apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
15. Use the mains plug to disconnect the apparatus from the This equipment is tested and approved
mains. according to the U.S. safety standard ANSI/
16. WARNING: To reduce the risk of fire of electric shock, do not UL 60065 and Canadian safety standard
expose this apparatus to rain or moisture. CSA C22.2 NO. 60065. ETL made the tests
17. Do not expose this equipment to dripping or splashing and and they are a Nationally Recognized
ensure that no objects filled with liquids, such as vases, are
placed on the equipment. Testing Laboratory (NRTL).
18. Do not connect the unit’s output to any other voltage source,
such as battery, mains source, or power supply, regardless of
whether the unit is turned on or off. 1.3 Explanation of Graphic Symbols
19. Do not remove the top (or bottom) cover. Removal of the cover
will expose hazardous voltages. There are no user serviceable
parts inside and removal may void the warranty.
20. An experienced user shall always supervise this professional The lightning bolt triangle is used to alert
audio equipment, especially if inexperienced adults or minors
the user to the presence of un-insulated
are using the equipment.
21. The US National Differences clause 16.3 requires that network “dangerous voltages” within the unit’s
cables must be flame rated VW-1. chassis that may be of sufficient magni-
tude to constitute a risk of electric shock
to humans.
1.4 Warning
To reduce risk of fire or electric shock, do not expose this apparatus to rain or moisture.
Français: Pour réduire les risques de blessure ou le choc électrique, n’exposez pas l’appareil à la pluie ou à l’humidité.
Do not expose this system/apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases,
are placed on the apparatus.
Français: L’appareil ne doit pas être exposé à des egouttements d’eau ou des éclaboussures et de plus qu’aucun objet
rempli de liquide tel que des vases ne doit pas être placé sur l’appareil.
This apparatus must be connected to a mains socket outlet with a protective earthing connection.
Français: Cet appareil doi t être raccordé á une prise de courant qui est branchée à la terre.
The mains plug is used as a disconnect device and shall remain readily operable.
Français: Lorsque la prise du réseau d’alimentation est utilisés comme dispositif de déconnexion, ce dispositif doit
demeuré aisément accessible.
1.5 Caution
To reduce the risk of fire or electric shock, do not remove screws. No user-serviceable parts inside. Refer servicing to
qualified service personnel.
Français: Pour réduire le risque d’incendie ou de choc électrique, ne pas retirer les vis. Aucune pièce réparable par
l’utilisateur. Confier l’entretien àpersonnel qualifié.
1.74 Maintenance
For safe and reliable operation, the dust filters on both sides of the front panel, behind the grilles, should be removed and cleaned
regularly to ensure maximum airflow through the device.
If the dust filters are not maintained there will be safety risks. For example, the unit can ignite the dust and a fire will occur
due to high internal temperatures. There is also a risk that the unit will malfunction since it is dependent on constant
airflow from front to rear. If the dust filters are not clean and the unit malfunctions, any resultant problems will not be covered
by the warranty.
7 technical SPECIFICATIONS.................................................................................................................30
8 WARRANTY...............................................................................................................................................31
Following are short descriptions of standard built-in Cable connections can be daisy-chained for easier
FP+ Series protection features: system setup. This also reduces total component
costs, simplifies installation, and makes daily opera-
▸▸ CPL, (Current Peak Limiter) ensures that the am- tion more convenient. There is no need to create
plifier’s output does not exceed the safe current a star topology using many switches as with, for
handling parameters of amplifier components. example, an Ethernet system. Individual amplifier
▸▸ Temperature protection ensures that the addresses do not need to be manually entered; you
amplifier will not be damaged by exceeding will automatically know where an individual amplifier
thermal limits. resides in the network.
▸▸ PAL, (Power Average Limiter) limits the maximum
average power consumption according to the A daisy chain network loop, in combination with
power supply and mains-breaker capabilities. the automatic addressing of devices, enables
▸▸ VHF, (Very High Frequency) protection circuits Lab.gruppen’s proprietary DeviceControl software
mute the output of the amplifier when non- to automatically create a precise picture of all con-
dynamic continuous signals above 10 kHz are nected devices and their relative position in the chain.
detected. By quickly creating a clear overview of the entire
▸▸ DC protection ensures destructive DC signals system configuration, DeviceControl provides flexible
will not appear at the amplifier outputs. If such control of very large amplifier systems. Set-up time is
conditions occur an internal fuse opens and fault minimized, and critical information is readily available
indication is displayed. for monitoring performance and solving problems
▸▸ Low-impedance (short circuit) protection pro- during operation.
vides a fault warning indication and shuts down
the output stage when, for example, an input Via NomadLink, you can monitor all metering data
signal is present and a malfunctioning cable or as well as all faults and warning indications simulta-
driver is short circuiting the output. neously. NomadLink also allows you to remotely
▸▸ High-impedance warning reports an alert when, control power on and power off, as well as engage
at the same time, output signal is high and no Mute and Solo functions on individual channels.
current draw is measured. This situation might
occur when no speakers are connected, or when
a driver is blown.
▸▸ Low inrush current ensures that the mains
breaker will not trip when several power
amplifiers are turned on simultaneously.
3.1 Unpacking
2x
2x
2x
2x
Make sure that there is an adequate air supply in front If you are not 100% confident of your
of the amplifier, and that the rear of the amplifier has competence to replace the mains plug, engage
sufficient space to allow the exhaust to escape. If qualified personnel to do the job.
the amplifier is rack-mounted, do not use covers or
doors on the front or rear of the rack. Once a suitable AC supply is connected, the
amplifier can be turned on using the front panel
Should a heat sink overheat, the temperature power switch. The amplifier then goes through a
sensing circuits will mute the overheating channel. soft-start sequence as it self-checks its circuits. The
If the power supply overheats, another sensing fans will blow at high speed before dropping to idle,
circuit will mute all output channels until the power and the “power” LED will illuminate.
supply cools to safe operating temperature. An early
warning before shut down will be indicated on the Inrush power is controlled and limited during “soft-
front panel LEDs, and a warning will be sent through start”, enabling multiple amplifiers to be powered up
the NomadLink network. simultaneously.
If the amplifier malfunctions due to dirty There is no ground lift switch or terminal on the
dust filters, any required repairs are not FP+ Series amplifiers. The signal ground is always
covered by the warranty. floating, via a resistor, to chassis and therefore the
grounding system is automatic.
The label placed to the right of the mains Use balanced input connections to avoid hum and
cable on the rear of the amplifier indicates the interference.
AC mains voltage for which the amplifier is wired
and approved: 115 V or 230 V. Connect the power
cable only to the AC source type referred to on the
label. The warranty will not cover damage caused by
connecting to an incorrect type of AC mains.
-10dB
A channel
HI-IMP CLIP VHF R
Must be grounded/earthed 1+ CH D+ 1+ CH C+
WIRING
2+ CH D+ NORMAL: CLASS 2 1+ CH B+ 1+ CH A+ 2+ CH B+
Made in Sweden XLR PIN 1-SCRN PIN 2-POS PIN 3-NEG 1- CH D- 1- CH C- 2- CH D- BRIDGED: CLASS 3 1- CH B- 1- CH A- 2- CH B-
Mains input 115 V NomadLink net- DIP-switches XLR connectors for 4 channel version
or 230 V operation work In and Out on for adjusting key inputs and loop thru shown with Neutrik
(Not selectable) EtherCon™ -housed features Speakon output
RJ45 connections (See below) connectors
Figure 4.2: Two- and four-channel speaker output connector options (not applicable to all models)
Must be grounded/earthed 1+ CH D+ 1+ CH C+
WIRING
2+ CH D+ NORMAL: CLASS 2 1+ CH B+ 1+ CH A+ 2+ CH B+
Made in Sweden XLR PIN 1-SCRN PIN 2-POS PIN 3-NEG 1- CH D- 1- CH C- 2- CH D- BRIDGED: CLASS 3 1- CH B- 1- CH A- 2- CH B-
All FP+ Series amplifiers except the FP 9000, FP 13000 and FP 14000 offer a choice of either binding post
(BP) or Neutrik© NL4FC Speakon output connectors (SP). The FP 9000, FP 13000 and FP 14000 are offered
with BP connectors only as the potential maximum output current exceeds the recommended limits for the
Speakon connectors.
ETHERNET
Must be grounded/earthed
5.3.2 Headroom, sensitivity and VPL / Gain The headroom available through the input stage to
settings the clip limiter is shown by the dotted lines as +10
The input amplifier and limiter system is designed dB at 195 V peak and +16.1 dB at 54 V peak. These
to accommodate extremes of performance. Typi- lines illustrate the additional signal level that can be
cally, exceeding maximum input by much as +10 dB accepted at the input before any significant distortion
will only result in a 1% increase in distortion. The will appear at the input stage.
following schematics illustrate how the adjustable
VPL and Gain circuitry affect input sensitivity and If you use the level potentiometer in the
output power. signal chain to reduce the level by an amount
greater than the headroom relative to input
The tables to the left of the illustration 7.3.2 below sensitivity, AND you drive the amplifier
show input sensitivity for a FP 13000 with a 2 ohm to clip level, you are in danger of clipping the input
load and 195 V peak (max.) and 54 V peak (min.) re- stage before the current or voltage peak limiters are
spectively for the eight different gain stages between activated.
+23 dB and +44 dB. The resulting output power is
displayed in dBu, Vrms and watts in the tables to the When bridging two channels, you must
far right. Complete input sensitivity tables for all VPL add +6 dB to the input sensitivity to achieve
and Gain settings for all FP+ Series models can be maximum output voltage due to the
found at www.labgruppen.com. automatic -6 dB gain compensation
inserted by the amplifier.
Input Amplifier Level Control Clip Limiter Voltage Peak Limiter Output Power Amplifier
Figure 5.4.1a: Audio inputs - four-channel models 5.4.3 Speakon Output connections
Refer to the instructions in this section if your amplifier
is equipped with the Speakon output connectors.
The XLR input connectors are electronically ba-
lanced, and wired according to the IEC 268 standard
(pin 2 = hot). XLR input connectors should be wired
as follows:
Pin 1 Ground/shield
Pin 2 Hot (+)
Pin 3 Cold (-)
Two-channel amplifiers – Two-channel amplifiers 5.4.4 Binding Post (BP) Output connectors
are wired in the following manner. The right Speakon Refer to the instructions in this section if your amplifier
connector, Channel A+B, provides outputs for both is equipped with Binding Post output connectors.
Channel A and Channel B. This output is useful when
wiring the amplifier for bridged mono operation. See
section 7.4.6. The left Speakon connector provides
an output for Channel B only.
Never connect an output terminal to ground, The unique adjustable input gain feature of the
or to any other input or output. Observe FP+ Series makes it easier to attain the optimum
relative loudspeaker polarity: loudspeakers balance between headroom and signal-to-noise ratio
connected in reverse polarity will exhibit in the signal path. A weak signal at the input might
degraded performance, particularly in bass frequen- require the gain to be raised in order to achieve maxi-
cies, and may be damaged as a consequence. mum output power with the lowest signal-to-noise
ratio. A “hot” input signal, however, would require
Use a high-quality stranded loudspeaker a lowering of the gain to avoid sending the amplifier
cable, and keep cable runs as short as into Voltage or Current clipping. See Appendix to
possible. review the table containing Gain versus VPL setting
implications for input sensitivity and output power.
5.4.5 Output bridge mode Bridge mode operation automatically compensates
It is possible to bridge channels in two-channel ver- by -6 dB, keeping all channels at the same gain.
sions, or in pairs of two (A+B and C+D) in four-channel
versions. When bridged, the input source must be
connected to input A (A+B) or C (C+D) respectively. 5.4.6.1 Channel gain/level (front-panel pots)
Output speaker cables must be connected to the Individual channel gain (level) may be adjusted using
plus pole on channel A or C and the minus pole on the potentiometers located on the front panel. Range
B or D. is from 0 dB to -infinity in 31 steps. The attenuation
is logarithmic, with the 12 o’clock position indicating
The main benefit of bridging the output is a doubling -10 dB.
of output voltage. Bridging can be used to turn a
four-channel FP 10000Q amplifier, for example into If the level control is used to attenuate to a
a three-channel amplifier with 2 x 1300 W and 1 x lower level than the headroom relative to
4200 W at 8 ohms or 2 x 2100 W and 1 x 5000 W input sensitivity AND the amplifier input is
at 4 ohms driven into clip, there is a danger of clipping
the input stage before the current or voltage peak
Most power amplifier designs, when bridged, auto- limiters are activated.
matically introduce a +6 dB input gain boost which
can lead the user to conclude that said amplifier 5.4.6.2 Amplifier sensitivity
delivers “more than double the power” when in Sensitivity is defined as how many Volts (rms) or
bridge mode. This is clearly not the case, as the dBu (referred to 0.775 Vrms) are required to achieve
gain boost artificially enhances perceived power at full (maximum) output power. As the output power
the cost of headroom. The FP+ Series amplifiers varies with the load impedance, 4 ohms is usually
work on globally set constant gain, and automatically the common reference. Since FP+ Series amplifiers
compensate the input gain by -6 dB. For example, if are capable of providing multiple maximum output
the amplifier is configured in a three-channel mode, power levels through use of the VPL feature, many
then the selected gain is maintained from input to sensitivity calculations may be required for a single
output on all channels. amplifier. We recommend use of the DeviceControl
software to simplify this process. DeviceControl’s
5.4.6 Amplifier Gain Device View page, used in combination with the DIP-
All FP+ Series amplifiers feature adjustable input gain. switch settings display, will automatically produce
This versatility enables the amplifier to accommodate a sensitivity calculation from the given data (VPL,
a multitude of system configurations with various Gain and load).
input sources and speaker layouts. Amplifier gain is
set globally for all channels. The range is +23 dB to
+44 dB in 3 dB steps. Individual channel fine level
adjustment is available using the potentiometers on
the front panel.
5.4.7 Output Voltage Peak Limiter (VPL) The values for VPL are displayed as maximum Voltage
Voltage Peak Limiter (VPL) is a unique feature in Peak. To translate Voltage Peak into Vrms, you must
FP+ Series amplifiers. It is used to select the maxi- divide the Voltage Peak values by 1.41 (see table).
mum power available on each output channel. VPL The VPL allows you to set the correct maximum
levels are set using the rear-panel DIP-switches; eight output peak power for optimum performance with
level positions are offered on all models except the the connected speakers. The correct setting depends
FP 6000Q, which offers six). on the system type and the specific load connected
to the channel. Since each channel can be configured
FP 14000 FP 13000 to deliver either very high voltage peak power OR
high current draw at low-impedances, it is important
V peak V rms V peak V rms to set the VPL correctly.
195 138 195 138
170 121 170 121 If you choose a lower VPL setting, you only reduce
140 99 140 99 the maximum output voltage. At the same time, this
116 82 116 82
allows more current headroom for low-impedance
100 71 100 71
80 57 80 57
loads. The amplifier thus runs at higher efficiency,
66 47 66 47 with a significantly reduced risk of going into thermal
54 38 54 38 protection.
warnings - 6 dB slope
operation area
Max. Continous
output power
5.5.1 Introduction
The FP+ Series amplifiers incorporate a sophisticated 20 Hz 10 kHz 20 kHz 30 kHz
and comprehensive set of protection features. Faults
and warnings are indicated on the front panel and Slow
Attack time
5.5.5 High-impedance warning (open load) longer on-time bursts until the protection mode is
A high-impedance (open load) condition is indicated activated.
when an input signal above approximately -29 dB
is detected and no functioning loudspeakers are If the temperature becomes too high to continue
connected to the amplifier. The fault in indicated safe operation, the overheated output channel(s)
by a orange Sig/Hi-imp LED. The indicator is green will be muted until the temperature returns to an
when a valid load is present under the same input acceptable level.
signal conditions
Fully active temperature protection (with muting) is
Since the Hi-impedance detection indicated by a constantly illuminated TEM LED. It
initially triggers only when the input signal will also be indicated as a fault via the NomadLink
rises above -29 dB, it might cause the network on the DeviceControl GUI.
indicator to first turn green, and then red,
even in situations where no speaker is connected. Temperature measurements will continue at 6
second intervals. The output will un-mute when the
5.5.6 Low-impedance protection warning channel or power supply returns to a safe operating
temperature.
A low impedance or short circuit fault is detected
when current draw is high (Current Peak Limiter
5.5.8 Power Average Limiter (PAL)
active) and when, simultaneously, output signal
is low (-4 dB LED does not illuminate). When this The Power Average Limiter (PAL) controls the
occurs, the amplifier protects the output stage current-drawing relationship between the power
from damage by muting the output signal and supply and the mains inlet. PAL limits the maximum
bypassing the circuits. Indication of this fault is a average power consumption according to the power
constant orange illumination of the Current Peak supply capabilities, ensuring that the PSU will not
Limiter (CPL) LED on the front panel. The protection overload. In addition, in the larger models that
will sequence at 6 second intervals to re-measure potentially could pull more current from the mains
conditions. If the low-impedance fault is no longer than the mains fuses are specified to handle (more
detected, the amplifier will un-mute. than 16 A), PAL limits the amplifier’s maximum
current draw to prevent blowing the mains fuse.
If the CPL turns constant orange, the output
is muted, and the -4 dB signal LED is ON, 5.5.9 Soft-Start
then the amplifier has gone into maximum High powered amplifiers with inadequate inrush
current protection. This situation is caused limiting can pull considerable current from the
by an excessive input signal and is not due to a short mains at turn-on. This can result in tripping of fast-
circuit. Turn down the input signal to avoid or acting mains breakers. Such is not the case with
remedy this situation. FP+ Series amplifiers. The FP+ Series amplifiers
have very low inrush power as the capacitors are
5.5.7 Temperature protection charged slowly and in a controlled manner ensuring
Thermal measurement points are provided on each that breakers will not trip.
output channel as well as on the power supply. These
indicators will, if the pre-specified temperature level Several amplifiers will, under normal conditions, be
is exceeded, give a high temperature warning. This able to be powered up simultaneously. If you do
warning condition is indicated by a flashing TEM LED experience problems powering up multiple ampli-
on the front panel, and it is reported on the Device fiers simultaneously, use the NomadLink network
Control GUI via the NomadLink network. and/or the NLB 60E to establish a power sequence
with a preset delay between the start-up of each
As the amplifier approaches a thermal protection subsequent amplifier.
threshold, the warning LED sequence will start with
short “on-time” bursts. If the amplifier continues
to overheat and approaches the temperature limit,
the flashing sequence will be defined by longer and
5.6.4 Performance, Warning and Fault continue until the short circuit is removed. CPL
indicators remains constant orange in a fault condition only
when an input signal is present.
Global Indicators: ▸▸ Temperature (yellow) warning is indicated
by a flashing LED. If the amplifier goes into
thermal protect (output muted), the TEM LED
illuminates constant yellow and the red MUTE
LED illuminates.
▸▸ VHF, Very High Frequency protection (yellow)
indicates that potentially harmful continuous high
frequencies have been detected on the input
signal. The output is muted (MUTE LED on).
▸▸ Hardware fault is indicated when both the CPL
and TEM, VHF and MUTE indicators light up
simultaneously. The amplifier requires servicing
before placing back in operation.
Figure 5.6.4a: Front panel global LED field
Channel Indicators:
It is very important that two IN or two OUT Please register at the website to gain access, and to
ports are NEVER connected to each other. allow us to inform you when updates are available.
This will cause the NomadLink communi-
cation and DeviceControl to exhibit erratic Optimal NomadLink performance can only
behavior and display inaccurate data. However, this be assured when using Cat-5 cables.
situation will not damage the amplifier circuitry. However, as NomadLink is only using two
wires + ground for communication and
Up to 60 amplifiers can be connected to one NLB phantom power it is possible to create converters
60E in a daisy-chain or closed loop. from RJ45 to, for example, XLR connectors using
2-wire shielded cable. The NomadLink network can
When the NLB 60E is powered up, the NomadLink then be operated using a standard tie-line in a
network receives phantom power. This causes the multicore signal distribution system. See the drawing
blue NomadLink LED on the amplifier front panel below for an example of how to create a
and the NomadLink LED on the rear panel to light converter.
up. NomadLink is active even when the amplifier has
mains power disconnected or is not yet powered
up.
980 feet.
▸▸ Rule 2: In a non-closed-loop daisy-chained subnet the total maximum cable length is 400 meters / 1300
feet.
▸▸ Rule 3: In a closed-loop subnet the total maximum cable length is 700 meters / 2300 feet.
Please review the DeviceControl Operation Manual for more detailed information.
Following are common questions asked about Q: How can I be sure that no protection circuits or
Lab.gruppen FP+ Series power amplifiers together safety functions interfere with the output signal?
with helpful answers. A: If no Clip or Warning LEDs on the front panel light
up, you can be fully confident that the rated maximum
Q: What is the input sensitivity of the amplifiers? output power in the full frequency range is available
A: Input sensitivity is calculated from the amplifier for your speakers. No limiting or gain-reduction takes
gain, maximum output voltage and load. As gain and place without a warning or fault indication.
output voltage is adjustable in FP+ Series amplifiers,
you need to look this information up in a table found in
the Appendix section of this manual. Input sensitivity 6.3 Additional documentation
also is automatically calculated in the DeviceControl
software application.
In case you didn’t find what you were looking for
Q: What are the maximum cable lengths allowed in this Operation Manual, check out the website
when using the NomadLink network? at www.labgruppen.com, where you can find a mul-
A: NomadLink uses a daisy-chain topology to titude of additional documentation for FP+ Series.
connect amplifiers and an NLB 60E in a network.
Standard RJ45-equipped Cat-5 cables are used
throughout. The daisy chain may be made into
a closed-loop by connecting a return cable to the
NLB 60E from the last amplifier.
FP 14000
Level Load Rated power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
FP 13000
Level Load Rated power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
FP 9000
Level Load Rated power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
FP 7000
Level Load Rated power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
FP 4000
Level Load Rated power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
APPENDIX 6
SIG -20 -15 -10 -4 VPL CPL VHF
HI-IMP CLIP TEM
-inf 0 POW
-10dB FP10000Q PAL FP SERIES
C channel HI-IMP CLIP VHF
SIG -20 -15 -10 -4 VPL CPL TEM
NOMAD
-inf 0 LINK
BRIDGE C+D MUTE
-10dB
Dchannel SIG -20 -15 -10 -4 VPL CPL VHF POW
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
FP 10000Q
Level Load Rated Power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
LAB.GRUPPEN AB ▸ SWEDEN
INTERNATIONAL CONTACT ▸ INFO@LABGRUPPEN.COM | US & CANADA CONTACT ▸ INFO@TCG-AMERICAS.COM
WWW.LABGRUPPEN.COM Item no. CDTD_FP10000Q_V5
FP 6000Q
Level Load Rated power Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” of the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
16 ohms Bridged per ch. 4700 W 3200 W 2900 W 1600 W 2600 W 1250 W
8 ohms Bridged per ch. 8800 W 6000 W 5600 W 3200 W 4200 W 2500 W
4 ohms Bridged per ch. 14000 W 9000 W 7000 W 4000 W 5000 W 3000 W
2 ohms Bridged per ch. 3) 3) 3) 3) 3) 3)
Performance with gain: 35 dB and VPL: 195 V 35 dB and VPL: 170 V 35 dB and VPL: 155 V 35 dB and VPL: 121 V 35 dB and VPL: 150 V 35 dB and VPL: 101 V
195, 170, 140, 116, 170, 140, 116, 100, 155, 121, 101, 83, 121, 101, 83, 70, 56, 150, 121, 101, 83, 101, 83, 70, 56, 47,
VPL, selectable per ch. (V)
100, 80, 66, 54 V 80, 66, 54 V 70, 56, 47, 38 V 47, 38 V 70, 56, 47, 38 V 38 V
390, 340, 280, 232, 340, 280, 232, 200, 310, 242, 202, 166, 242, 202, 166, 140, 300, 242, 202, 166, 202, 166, 140, 112,
VPL, selectable when bridged (V) 1) 94, 76 V
200, 160, 132, 108 V 160, 132, 108 V 140, 112, 94, 76 V 112, 94, 76 V 140, 112, 94, 76 V
Front-panel indicators
Common NomadLink network; Power Average Limiter (PAL) 2); Power on
Per channel Signal present / High-impedance; -20 dB, -15 dB, -10 dB and -4 dB output
signal; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL):
Very High Frequency (VHF); High temperature; Fault; Mute
Power
Operating voltage, 230 V / 115 V nominal 4) 130-265 V / 65-135 V
Minimum power-up voltage, 230 V / 115 V 171 V / 85 V
Power Average Limiter (PAL) 2) Yes
Soft start / Inrush Current Draw Yes / max. 5 A
Mains connector 230 V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock | FP 4000: 230 V CE: 16 A, CEE7; 115 V ETL: 20 A / NEMA 5-20P
dimensions W: 483 mm (19”), H: 88 mm (2 U), Overall D: 396 mm (15.6”), Mounting D: 358 mm (14.1”)
Weight 12 kg (26.4 lbs.)
Finish Black painted steel chassis with black painted steel / aluminum front
Approvals CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
International Warranties
Please contact your supplier or distributor for this
information, as rights and disclaimers may vary
from country to country.