Professional Documents
Culture Documents
Evaluation of Optimal Sensor Placement Algorithms For The Structural Health
Evaluation of Optimal Sensor Placement Algorithms For The Structural Health
Engineering Structures
journal homepage: www.elsevier.com/locate/engstruct
A R T I C LE I N FO A B S T R A C T
Keywords: In recent years, Structural Health Monitoring (SHM) based on Operational Modal Analysis (OMA) and damage
Historical building detection tools has become a popular non-destructive solution to assess the real-time integrity of any kind of
Uncertainty analysis structure. This technique is especially well-suited for the condition-based conservation of historical structures,
Operational modal analysis where minimal invasiveness must be ensured owing to their high cultural and architectural value. Optimal
Non-destructive test
Sensor Placement (OSP) techniques represent a valuable tool for efficiently designing the sensor layout in a SHM
Ambient vibration test
system in order to achieve an effective modal identification with a reduced number of sensors and, consequently,
an improved cost efficiency. In this light, this paper proposes a design methodology of sensor networks based on
OSP techniques suitable for historical structures. To do so, a preliminary extensive OMA campaign is conducted
in order to construct a reliable finite element (FE) model by fitting the identified modal properties. Afterwards,
an optimal sensor arrangement with a limited number of sensors is obtained by applying different model-based
OSP techniques. In order to improve the robustness of the solution, material uncertainties are included in the
model and the optimal sensor placement is conducted within a statistical framework. This methodology is
presented and evaluated with a case study of a Spanish secular building: the Monastery of San Jerónimo de
Buenavista in Seville (Spain). In particular, this paper presents the results of the preliminary ambient vibration
test and the modal identification of the monastery, the updating process of the FE model, as well as a critical
review of the different OSP techniques within a framework of material parameter uncertainty. The presented
analysis demonstrate that OSP techniques based on the rank optimization of the kinetic energy matrix of the
structure yield robust sensor layout.
⁎
Corresponding author.
E-mail address: ppachon@us.es (P. Pachón).
https://doi.org/10.1016/j.engstruct.2019.109843
Received 12 March 2019; Received in revised form 7 September 2019; Accepted 21 October 2019
Available online 09 November 2019
0141-0296/ © 2019 Elsevier Ltd. All rights reserved.
P. Pachón, et al. Engineering Structures 202 (2020) 109843
2
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 2. Historical development of the Monastery of San Jerónimo: (a) Original configuration, 1650; (b) historical remains, 2000; and (c) current architectural
configuration of the complex, 2018.
2. Monastery of San Jerónimo de Buenavista the southern and eastern galleries annexed to the main cloister [30].
From a structural point of view, a mixed system of load-bearing walls
This study focuses on the west gallery of the main cloister of the and pillars supporting large-edged beams was used to construct the new
Monastery of San Jerónimo de Buenavista, a historical building located building (Fig. 4).
in the city of Seville, Spain. The beginning of its construction dates back As a result of the new protection policy for the Monastery of San
to the early fifteenth century. Originally, the Monastery of San Jerónimo, several damages had already been detected before the con-
Jerónimo consisted of an aggregate of five main buildings: the church, struction of the new civic centre. These are related to the following
the eastern cloister, the main cloister, the tower and the printing press aspects: cracking of structural elements, cracking in auxiliary elements,
(Fig. 2a). However, only part of the main cloister and the tower of the excessive deformations, failures in foundations, concentration of hu-
church are still preserved today (Fig. 2b). The eastern cloister, the midity, corrosion of metallic elements, disintegration, cracking, factory
printing press and a large part of the church disappeared as a result of swelling and attacks, etc. (Fig. 5). In January 2015, and due to the fact
the numerous vicissitudes that the monastery has suffered over the that some of the damages listed above were aggravated during the
course of centuries [29]. works, the Town Planning Department of Seville City Council com-
The remains of the main cloister constitute a Renaissance-style missioned a research project for the structural analysis of the cloister.
construction consisting of four galleries, which are made up of seven The research project indicated above follows the approach ratified
pillars on each side, attached columns and semicircular arches on the by the ICOMOS 14th General Assembly in Victoria Falls, Zimbabwe, in
ground floor and bells on the first floor. These galleries are delimited by 2003 [1]. The main objective was to conduct a diagnosis of the building
brick masonry walls and covered by ribbed stone vaults. Currently, in to justify different conservation proposals to ensure the integrity of all
the west gallery, the entire ground floor is conserved while only the its elements. A multidisciplinary work team composed of architects,
vertical structure and the arches are preserved on the upper floor engineers, archaeologists and historians carried out the research pro-
(Fig. 3). ject. An extensive historical study of the different interventions in the
In 1964, the monastery was declared a heritage site due to the ar- building was finally presented, as well as a report about its structural
chitectural importance of the whole building. Since then, it has been health condition. To elaborate this report, complex numerical analysis
subjected to several restoration operations [29]. The last one was the and several moderately destructive and non-destructive tests were
execution of a rehabilitation and adaptation project for a civic centre in conducted, including ambient vibration tests, archaeological tastings,
2013 (Fig. 2c). The project basically consisted of the reconstruction of tomography and sonic wave tests and georadar tests on the columns
3
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 4. Views of the civic centre annexed to the Monastery of San Jerónimo.
and ground. This project allowed us to obtain a vast amount of ex- gallery was observed, since each one presents its own uncoupled vi-
perimental and numerical information from the west gallery of the bration modes. For instance, the second and fourth global modes cor-
cloister. The data obtained from these previous works were funda- respond to local modes of the west gallery. Regarding that the goal of
mental for the development of the present study, since it was possible to the study is the evaluation of the different OSP techniques, it was
reduce the high level of uncertainty that usually surrounds the struc- decided to perform the analysis considering only the west gallery due to
tural characterisation of this type of buildings. the large size of the complete model. This last consideration makes it
possible to reduce the computational cost of the study without losing
3. FE modelling and analysis generality in the evaluation of the different OSP techniques for their
application in masonry structures. A numerical sub-model of this gal-
The reparation works in the historical building allowed us to per- lery (Fig. 7) was generated with ANSYS [31]. The influence of the other
form several extensive experimental campaigns in the monastery be- parts of the structure were considered through appropiate boundary
tween September and November 2013. Ambient vibration tests were conditions to simulate the connection with the rest of the structure.
performed in the west gallery with the aim of identifying the natural With regard to the numerical definition of the preliminary FE
frequencies, mode shapes and damping ratios of the system. In order to model, the whole gallery was modelled with 4-node solid elements,
ensure an efficient identification of the modal properties of the case with the exception of a 5-centimetre concrete compression layer located
study, a preliminary finite element model was previously developed above the vaults which was modelled with 3-node triangular shell
with the aim of properly designing the test set-up. This numerical model elements. In this way, the model has a total of 1,462,311 elements
was later updated based on the results obtained from the OMA of the (1,454,047 solid and 8264 shell elements), 275,475 nodes and 826,425
ambient vibration tests. This model updating process is described in degrees of freedom. The boundary conditions are defined as constrained
sections below. displacements and free rotations in the foundation, whilst the lateral
boundary conditions are extracted from the general model. Table 1
summarizes the material properties used in the modelling. Note that the
3.1. Preliminary FE model repair works allowed us to reliably test some elements, such as the
material properties of the fillings. Dynamic tests were also carried out
Based on a complex geometric survey, a sophisticated three-di- on the stone and brick masonries to identify the Young’s moduli and
mensional FE model of the whole monastery was developed in order to densities of these elements. However, it was not possible to determine
conduct a subsequent structural analysis that is not a subject of this these parameters with certainty due to the great variability of the ob-
work. Initially, the modal behaviour of the entire structure was ana- tained results. Thus, these four parameters will be subsequently se-
lysed. The results of the modal analysis of the monastery is depicted in lected as the variables to be updated.
Fig. 6. As noted above, a modal analysis of this preliminary FE model was
In the light of this analysis, the dynamic independence of each
Fig. 5. Detected damage in the main cloister of the Monastery of San Jerónimo.
4
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 6. Three-dimensional FE model of the monastery and numerical identification of the first five global modes.
5
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 8. First five numerical vibration modes and undeformed configuration of the FE model.
3.3. OMA and model updating identification of damping ratios under operational conditions while the
EFDD method, based on computation of the response spectrum data,
The data obtained in-situ were processed with the software usually requires longer records to obtain an acceptable error in spec-
ARTEMIS [33] using two different identification methods: Enhanced trum estimation and, therefore, to extract modal parameters in a reli-
Frequency Domain Decomposition (EFDD) [34] and Stochastic Sub- able way [37]. Finally, in relation to the mode shapes, with the ex-
space Identification (SSI-UPC Merged) [35,36] (Fig. 10). ception of the first mode, which is a bending mode of the full gallery, all
Regarding the signal processing, a decimation factor of 5 and a the modes are induced by the changing shape of the transverse arches of
spectral density resolution of 1024 was used, which leads to a frequency the first floor. The great complexity of these modes can be seen in
line spacing of 0.005 Hz. In this way, the mode shapes and the modal Fig. 11.
frequencies of the gallery were obtained. The resulting modal para- Based on the experimental results, the preliminary numerical model
meters of the gallery are summarized in Table 2. is updated to simulate the current modal behaviour of the gallery and
As indicated in Table 2, the first five vibration modes of the gallery assist the evaluation of the OSP methods. The same procedure as in
have been identified in the frequency range from 0 to 5 Hz. Frequency previous works by the authors was followed [38]. Hence, iterative
values are obtained with a high degree of reliability, with differences methods are used to perform the FE model updating [39], introducing
between both methods always lower than 2% . However, the values of changes directly to some of the physical parameters that define the
the damping ratios present larger variability. This typical fact indicates structure. As indicated above, the parameters to be updated are the
that higher levels of excitation are usually necessary for the correct Young’s moduli of the stone and brick masonries due to the high degree
identification of the modal damping of such structures. Time domain of dispersion detected during the characterization tests. The selection of
methods have been proved to have better performance in the more parameters is not necessary, since their values have been reliably
Fig. 9. Plan view of the accelerometer locations (reference accelerometers in blue). (For interpretation of the references to colour in this figure legend, the reader is
referred to the web version of this article.)
6
P. Pachón, et al. Engineering Structures 202 (2020) 109843
7
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 11. First five experimental vibration modes and undeformed configuration of the experimental model.
Table 4
Comparison of numerical and experimental modal parameters, the latter
identified by the SSI algorithm.
Mode fexp (Hz) fnum (Hz) MACexp − num fupd (Hz) MACexp − upd
8
P. Pachón, et al. Engineering Structures 202 (2020) 109843
effective independence of the target mode shapes (EFI and EFIwm), and energy or the kinetic energy [44]. Following the modal analysis of the
two others based on the concept of energy matrix rank optimization FE model of the system, the strain energy (SE ) and kinetic energy (KE )
(KEMRO and SEMRO). In the following, the theoretical background of matrices can be written as [46,47]:
these techniques is concisely outlined.
SE = φT K φ, KE = φT M φ (8)
The Effective Independence (EFI) method [42,43] seeks the optimal
location of sensors as those DOFs of the FE model that maximize the where K is the numerical stiffness matrix computed by the FEM. In this
linear independence of the mode shapes. Based upon the modal analysis regard, the FIM matrices can be assembled by using the Cholesky de-
of the FE model, the target modal matrix φ Nd × Nm can be computed, composition of the stiffness and mass matrices as follows:
which contains the retained target modes as columns and the candidate
K = CTC , M = DT D (9)
DOFs as rows. Thereby, the Fisher Information Matrix, FIM Nm × Nm , of
the target modal matrix reads [44]: with C and D being upper triangular matrices. Accordingly, the FIM
matrices take the forms:
FIM = φT φ (3)
FIMSE = (C φ)T C φ, FIMKE = (D φ)T D φ (10)
which can be diagonalized by solving the eigenvalue/eigenvector pro-
blem: and the projection matrices:
as FIM = ψ Λψ−1, where Λ Nm × Nm is the diagonal matrix of the eigen- where subscripts “SE” and “KE” relate the corresponding quantities to
values λi of the FIM, and ψ Nm × Nm contains the corresponding eigen- the strain and kinetic energies, respectively. Once the projection ma-
vectors ψi by columns. Given that the FIM is symmetric and positive trices are defined, the procedure for finding the optimal sensor locali-
definite, the eigenvectors are orthogonal (i.e. ψ−1 = ψT ) and form an zations is identical to the previously introduced EFI algorithms. In a
orthogonal basis in an Nm -dimensional space. Therefore, the product φψ similar way to the EFIwm method, Guyan reduction is needed to reduce
yields an Nd × Nm matrix that represents the projection of the mode the stiffness and mass matrices at each iteration. The OSP algorithms
shapes φi onto the Nm -dimensional space spanned by the vectors ψi . based on the elimination of candidate DOFs with minimum contribu-
Squaring each element in the φψ matrix as A = φψ ⊗ φψ , with ⊗ tions to the rank of EKE and ESE matrices are referred to as the KEMRO
denoting term-by-term matrix multiplication, the elements Aij of the and SEMRO methods, respectively.
resulting matrix represents the contribution of each i-th DOF to each j-th
mode shape. If weighted by the inverse of the eigenvalue matrix of the 4.2. Identification of the optimal number of sensors
FIM as A = φψ ⊗ φψ Λ−1, each element in this matrix has equal im-
portance. The summation by columns of the A matrix leads to a Nd × 1 The application of the above OSP techniques to the case study is
N
vector F whose components Fi = ∑ j =m1 Ai, j represent the contribution of now addressed. First of all, the required number of sensors is de-
every i-th DOF to all the retained modes of interest. Alternatively, the termined. Different scenarios were explored by varying the number of
orthogonal projection matrix E can be defined as [42]: accelerometers of the monitoring system from 2 to 16. The EFI method
is employed to find the optimal configuration for each case. In order to
E = φψ Λ−1 (φψ)T = φ FIM−1 φT (5) analyse the goodness of the OSP solution, the data of the ambient vi-
The elements on the diagonal of the E projection matrix equals the bration tests are used. The difference between the modal properties
components of the F vector and, therefore, represent the relative con- obtained via OMA using the complete test data (reference) and those
tribution of the candidate DOFs to the target mode shapes. It can be obtained only by using the data from sensors placed at the optimal
proved that the E matrix is idempotent [42], that is E2 = E . A well- configuration is analysed. In particular, the error is computed as:
known property of idempotent matrices is that their trace is equal to Nm 1/2
their rank. Therefore, the optimal placement of sensors can be related ⎡ ⎤
total error(%) = ⎢∑ Ri2 ⎥
to the DOFs where the diagonal terms of E are maximum or, in other ⎣ i=1 ⎦ (12)
words, the DOFs with maximum contribution to the linear in-
where Nm is the total number of considered modes and Ri is the relative
dependence of the target mode shapes. In this light, the EFI method is
error between the reference natural frequency of mode i;fref , i , and the
defined in an iterative way by eliminating those candidate DOFs whose
frequency identified using only data from sensors in the OSP solution;
contribution to the rank of the projection matrix is minimal, and the
fosp, i . That is:
procedure finishes when the number of remaining DOFs reaches the
desired number of sensors. ⎡ fref , i − fosp, i ⎤
An alternative OSP method considering the mass weighting of the Ri (%) = 100·⎢ ⎥
fosp, i (13)
effective independence of the target mode shapes is also considered, ⎣ ⎦
usually referred to as the EFIwm method. In this case, the Fisher in- In Fig. 13, the total error is shown for several cases considering
formation matrix FIM takes the form: different numbers of sensors in the OSP problem. Note that the error is
stabilized for a number of sensors greater than 8. Given these results, it
FIM = φT M φ (6)
can be considered that 8 is the optimal number of accelerometers for
and, consequently, the projection matrix E reads [45]: the case of the Monastery of San Jerónimo, since a reasonable increase
in the number of sensors does not significantly reduce the error in the
E = M1/2φ FIM−1 φT (M1/2)T (7)
identification of the natural frequencies of the structure.
where M stands for the numerical mass matrix extracted from the FE
model. Given that the mass matrix is diagonalizable, the square roots 4.3. Evaluation of the performance of OSP methods
M1/2 in Eq. (7) can be readily obtained by eigen-decomposition. In
addition, in order to eliminate the DOFs with minimum contribution to Once the required number of sensors for the long-term monitoring
the rank of E , Guyan reduction must be implemented at each iteration system has been determined, the OSP problem is performed to obtain
to reduce the mass matrix M to the remaining candidate DOFs. the best positions for these 8 sensors. Four different OSP methods are
On the other hand, Energy Matrix Rank Optimization (EMRO) evaluated, namely EFI, EFIwm, KEMRO and SEMRO.
techniques are based upon the deployment of sensors at locations that In Fig. 14, the relative error in the identification of natural fre-
maximize the energy of the monitored system, typically the strain quencies and the total error are shown for each method. For the EFI and
9
P. Pachón, et al. Engineering Structures 202 (2020) 109843
10
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 15. Normalized sensor selection for different OSP methods considering deterministic material parameters.
Fig. 17. Dispersion percentage for different number of samples in the MCS.
Fig. 18. Dispersion percentage for different OSP methods with 20% of para-
when considering uncertainty in the value of the model parameters,
meter variability.
with less than 3% dispersion of the results.
The solution considering a parametric variability of 20% is re-
presented in Fig. 19 for different OSP methods. In this case, the prob- parametric uncertainties, the points 6, 10 and 12 in the y direction are
ability of sensor selection is computed for each method and represented selected with a high probability for the EFI, EFIwm and SEMRO
in the plot in a normalized form. There are two common positions se- methods. Another interesting result is that the point 3y is selected by the
lected by all the methods at all iterations: points 7 and 11, both in the y four methods but with a very low probability (below 25%). In view of
direction. The point 5y is also selected for the four methods with a these results, the effect of considering a parameter variability of 20%
combined probability greater than 95% . As in the case with no does not strongly affect the solution of the OSP problem.
11
P. Pachón, et al. Engineering Structures 202 (2020) 109843
Fig. 19. Normalized probability of sensor selection for different OSP methods with 20% of parameter deviation.
12
P. Pachón, et al. Engineering Structures 202 (2020) 109843
modal analysis algorithm for vibration-based monitoring and tensile load estima- Nervi’s Turin Exhibition Centre. Eng Struct 2017;137:256–67.
tion. Mech Syst Signal Process 2015;60:512–34. [27] Lenticchia E, Ceravolo R, Antonaci P. Sensor placement strategies for the seismic
[8] Ramos LF. Damage identification on masonry structures based on vibration sig- monitoring of complex vaulted structures of the modern architectural heritage.
natures, Ph.D. thesis. Universidade do Minho; 2007. Shock Vib; 2018. art. no. 3739690.
[9] Diaferio M, Foti D, Giannoccaro N. Identification of the modal properties of a [28] Pachón P, Castro R, García-Macías E, Compán V, Puertas E. Torroja’s bridge: tai-
building of the Greek heritage. Key Eng Mater 2014;628:150–9. lored experimental setup for SHM of a historical bridge with a reduced number of
[10] Diaferio M, Foti D, Gentile C, Giannoccaro N, Saisi A. Dynamic testing of a historical sensors. Eng Struct 2018;162:11–21.
slender building using accelerometers and radar. Proceedings of the 6th interna- [29] Pozo F, Gil R, Méndez E. Intervención arquitectónica puntual en Monasterio de San
tional operational modal analysis conference. 2015. Jerónimo de Buenavista (Sevilla). Consejería de Urbanismo; 2003.
[11] Rainieri C, Fabbrocino G, Verderame G. Non-destructive characterization and dy- [30] García-Tapial J, Sánchez F. Proyecto de Rehabilitación del Monasterio de San
namic identification of a modern heritage building for serviceability seismic ana- Jerónimo de Buenavista para su adecuación a Centro Cívico, Servicio de
lyses. NDT E Int 2013;60:17–31. Rehabilitación y Renovación Urbana; 2004.
[12] Foti D, Giannoccaro N, Diaferio M, Ivorra S. Structural identification and numerical [31] A.R. 14.0, ANSYS User’s Manual; 2011.
models for slender historical structures. In: Handbook of research on seismic as- [32] Ramos L, Marques L, Lourenço P, Roeck GD, Campos-Costa A, Roque J. Monitoring
sessment and rehabilitation of historic structures, vol. 2, IGI Global; 2015, Ch. 23. p. historical masonry structures with operational modal analysis: two case studies.
674–703. Mech Syst Signal Process 2010;24(5):1291–305.
[13] Torres W, Almazán JL, Sandoval C, Boroschek R. Operational modal analysis and FE [33] Solutions SV. Artemis modal 5.0. User’s Guide; 2015.
model updating of the Metropolitan Cathedral of Santiago, Chile. Eng Struct [34] Wang T, Celik O, Catbas F, Zhang L. A frequency and spatial domain decomposition
2017;143:169–88. method for operational strain modal analysis and its application. Eng Struct
[14] Rainieri C, Dey A, Fabbrocino G, de Magistris FS. Interpretation of the experi- 2016;114:104–12.
mentally measured dynamic response of an embedded retaining wall by finite [35] Peeters B, de Roeck G. Reference-based stochastic subspace identificaiton for output
element models. Measurement 2017;104:316–25. only modal analysis. Mech Syst Signal Process 1999;13(6):855–78.
[15] Rainieri C, Fabbrocino G, Cosenza E. Integrated seismic early warning and struc- [36] Döhler M, Andersen P, Mevel L. Data merging for multi-setup operational modal
tural health monitoring of critical civil infrastructures in seismically prone areas. analysis with data-driven ssi. Structural dynamics, vol. 3. New York: Springer;
Struct Health Monitor 2011;10(3):291–308. 2011. p. 443–52.
[16] Farrar CR, Worden K. An introduction to structural health monitoring. Philos Trans [37] Rainieri C, Fabbrocino G, Cosenza E. Some remarks on experimental estimation of
Roy Soc A: Math Phys Eng Sci 2007;365(1851):303–15. damping for seismic design of civil constructions. Shock Vib 2010;17(4–5):383–95.
[17] Bernardeschi K, Padovani C, Pasquinelli G. Numerical modelling of the structural [38] Pachón P, Compán V, Rodríguez-Mayorga E, Sáez A. Control of structural inter-
behaviour of Buti’s bell tower. J Cult Herit 2004;5(4):371–8. vention in the area of the Roman Theatre of Cadiz (Spain) by using non-destructive
[18] Saisi A, Gentile C, Guidobaldi M. Post-earthquake continuous dynamic monitoring techniques. Constr Build Mater 2015;101:572–83.
of the Gabbia Tower in Mantua, Italy. Constr Build Mater 2015;81:101–12. [39] Teughels A. Inverse modelling of civil engineering structures based on operational
[19] Ubertini F, Comanducci G, Cavalagli N, Pisello AL, Materazzi AL, Cotana F. modal data Ph.D. thesis University of Leuven; 2003.
Environmental effects on natural frequencies of the San Pietro bell tower in Perugia, [40] Allemang RJ, Brown DL. A correlation coefficient for modal vector analysis.
Italy, and their removal for structural performance assessment. Mech Syst Signal Proceedings of the 1st international modal analysis conference. 1982. p. 110–6.
Process 2017;82:307–22. [41] MathWorks, MATLAB R2015a. User’s Guide; 2015.
[20] Lorenzoni F, Casarin F, Modena C, Caldon M, Islami K, da Porto F. Structural health [42] Kammer DC. Sensor placement for on-orbit modal identification and correlation of
monitoring of the Roman Arena of Verona, Italy. J Civil Struct Health Monitor large space structures. J Guid Control Dyn 1991;14(2):251–9.
2013;3(4):227–46. [43] Kammer D, Yao L. Enhancement of on orbit modal identification of large space
[21] Elyamani A, Caselles O, Roca P, Clapes J. Dynamic investigation of a large historical structures through sensor placement. J Sound Vib 1994;171(1):119–39.
cathedral. Struct Control Health Monitor 2016;24(3):e1885. [44] Triguero RC, Murugan S, Gallego R, Friswell MI. Robustness of optimal sensor
[22] Stefano AD, Matta E, Clemente P. Structural health monitoring of historical heritage placement under parametric uncertainty. Mech Syst Signal Process
in Italy: some relevant experiences. J Civil Struct Health Monitor 2013;41:268–87.
2016;6(1):83–106. [45] Lollock J, Cole T. The effect of mass weighting on the effective independence of
[23] Afreen A, Ahmed A, Moin K. State of art review?: Structural health monitoring, mode shapes. In: Proceedings of the 46th AIAA/ASME/ASCE/AHS/ASC structures,
retrofitting and rehabilitation of masonry structures. Int J Latest Eng Manage Res structural dynamics and materials conference, no. 1836; 2005.
2018;03(02):105–15. [46] Hemez FM, Farhat C. An energy based optimum sensor placement criterion and its
[24] Ramos LF, Aguilar R, Lourenço PB, Moreira S. Dynamic structural health mon- application to structural damage detection. In: Proceedings of the 12th interna-
itoring of Saint Torcato church. Mech Syst Signal Process 2013;35(1):1–15. tional modal analysis conference, vol. 2251; 1994.
[25] Brigante D, Rainieri C, Fabbrocino G. The role of the Modal Assurance Criterion in [47] Heo G, Wang ML, Satpathi D. Optimal transducer placement for health monitoring
the interpretation and validation of models for seismic analysis of architectural of long span bridge. Soil Dyn Earthquake Eng 1997;16(7–8):495–502.
complexes. Procedia Eng 2017;199:3404–9. [48] Schueller GI. Efficient Monte Carlo simulation procedures in structural uncertainty
[26] Lenticchia E, Ceravolo R, Chiorino C. Damage scenario-driven strategies for the and reliability analysis-recent advances. Struct Eng Mech 2009;32(1):1–20.
seismic monitoring of XX century spatial structures with application to Pier Luigi
13