You are on page 1of 6
TECHNICAL SPECIFICATIONS ADSS OPTICAL FIBRE CABLE 24/48F MULTITUBE ADSS OPTICAL FIBRE CABLE \u Leable Description || In this cable, optical fibres and water-blocking gel is placed inside buffer tubes. The core is constructed by stranding the buffer tubes around FRP rod, the central strength member. Water swellable yarn is provided over the FRP Rod and the core is wrapped in water swellable tape over which aramid yarn is applied as peripheral strength member. This core is then covered with a black HDPE jacket. Ripcords are provided under the jacket for ease of entry. Applications © Aerial ¢ Trunk, Distribution, Feeder * Local loop, Metro & Long Haul application Features ‘© Multiple network applications ‘* Wet core option available Page 20f6 Fibre Count Fibre Loose Tube (Gel Filled) FRP Rod Water Swellable Varn Filler Water Swellable Tape Aramid Yarn Ripcord Outer Sheath, 24/48 Number of fibres per tube 12 Glass Fibre Number of Loose Tubes 2/4 PBT Central Strength Member 1.6 + 0.1mm) FRP Rod Number of Fillers aft HDPE - Natural Moisture Barrier Over FRP Rod Water Swellable Yarn Core Wrapping Over SZ Core Water Swellable Tape Peripheral Strength Member Over WS Tape Aramid Yarn Outer Sheath 1.5 mm (Nominal) MDPE - Black Number of Ripcords 1 Polyester Cable Dimensions: 9.5 +0.5 mm Cable Weight 60 + 10 kg/km Page 30f6 Color Coding | | EIA/TIA 598 EIA/TIA 598 able Characteristics |_| Tensile Strength 1500 N IEC 60794-1-21-E1 Crush Resistance 1500 N/100 mm IEC 60794-1-21-E3 Impact Strength 3Nm IEC 60794-1-21-E4 Torsion + 180° IEC 60794-1-21-E7 Kink 10xD IEC 60794-1-21-E10 Minimum Bend Radius 20xD. TEC 60794-1-21-E11 1m water head, 3m ample, 24 RGus IEC 60794-1-22-F5 Water Penetration Test Span Installation -20° Cto + 70°C Operation -20° Cto+ 70°C TEC 60794-1-22-F1 Storage -20° Cto+ 70°C Page 4of6 Optical 7310 nm 0.35 dB/km 1550 nm = 0.21 dB/km 1285 - 1330 nm $3.5 ps/nmkm 1550 nm = 18.0 ps/amkm Cable cut-off wavelength hee = 1260nm Zero Dispersion Wavelength 1302 - 1322 nm << 0.092 ps/nm?x km Fibre 202 ps/km Link Design Value ‘= 0.08 ps /km Mechanical Tum [32mm 0.05 48 100 .05 dB tums |? 52mm .05 dB 100 turn | » 60mm ).05 dB Proof Stress Level 1.0.% (100 kpsi) Geometrical 1310nm 9.204 um 1550 nm 10.4 + 0.5 nm Core ~ Cladding Concentricity Error 0.6m Cladding Diameter 125+ 1.0 um Cladding Non - Circularity 510% Coating - Cladding Concentricity Error =12 um (Uncolored) 24510 um (Colored) 2502 15 um UV Cured Acrylate Fibre Curl >4m Attenuation Chromatic Dispersion Zero Dispersion Slope Polarization mode dispersion Bending induced attenuation Mode Field Diameter Primary Coating Diameter Primary Coating Material Page Sof 6 Marking on Cable As per customer requirement. Packing Details The cable is available in standard drums of 2.0 km + 10 %. It shall be provided on wooden drums or spools. Both the cable ends shall be sealed & readily accessible. Each drum shall be permanently labelled on both sides of the flange with information required by the customer in addition to the following standard marking: + Drum Number * User Name Fiber Count Cable Length Year of Manufacture Net Weight Gross Weight Page Gof 6

You might also like