Removal Procedure
NOTICE
NOTICE
1. Drain the coolant from the cooling system into a suitable container for storage or disposal.
Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change" for the
correct draining and filling procedures.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 11/19/2017
3512 GENERATOR SET ENGINE 24Z00001-01316(SEBP1281 - 01) - Documentation Page 2 of 3
Illustration 1 g01963076
3. Remove bolts (1) and the retainers. Disconnect the tube assembly from the water pump.
Remove the O-ring seal from the tube assembly.
4. Remove bolts (2) and disconnect the adapter. Remove the gasket.
Illustration 2 g01963077
5. Attach a suitable lifting device onto water pump (5). The weight of water pump (5) is
approximately 40 kg (88 lb).
Installation Procedure
1. Install water pump (5) in the reverse order of removal.