User Manual
TPS-NU
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
1 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
2 / 79
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
Contents
Bibliography 7
Glossary 9
1 Introduction 13
1.1 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.1.1 CheckBox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.1.2 ComboBox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.1.3 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.1.4 Radio button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.1.5 ListBox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.1.6 Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.1.7 Context Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 Graphic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.3 Textual Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2 Product Description 17
2.1 Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.1.1 Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.1.2 Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.2 Product Functionalities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3 Installation 23
3.1 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.2 Hardware requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4 Software Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4 Program Start 25
4.1 Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.2 Working Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.3 Autorizzazioni . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5 Basic features 37
5.1 Common parts description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.1.1 Menu - File (Alt-f) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.1.2 Menu - System (Alt+S) . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.1.3 Menu - Options (Alt+o) . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
5.1.4 Menu - Help (Alt+h) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6 TPS-NU Configurator 45
6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.2 Description of the interface user . . . . . . . . . . . . . . . . . . . . . . . . . . 47
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
CONTENTS 3 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
7 TPS-NU Monitor 63
7.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
7.2 Description of the user interface . . . . . . . . . . . . . . . . . . . . . . . . . . 67
7.2.1 Menu - Operations (Alt+p) . . . . . . . . . . . . . . . . . . . . . . . . . . 67
7.3 Alarms Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
7.3.1 Line Unit (UL) Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
7.3.2 Processing Unit (UE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
7.3.3 High Voltage Command (UAT) Alarms . . . . . . . . . . . . . . . . . . . 73
8 Other informations 75
8.1 Assistance through Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
4 / 79 CONTENTS
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
List of Figures
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
LIST OF FIGURES 5 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
6 / 79 LIST OF FIGURES
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
List of Tables
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
LIST OF TABLES 7 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
8 / 79 LIST OF TABLES
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
Bibliography
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
BIBLIOGRAPHY 9 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
10 / 79 BIBLIOGRAPHY
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
Glossary
tpsnu ct
TPS-NU craft terminal
TPS-NU
Selta SpA universal Teleprotection equipment
FW
Firmware.
RTC
Real Time Clock.
SNMP
Simple Network Management Protocol
TAC
Command transmission time: time required by transmission medium to send a command
to the remote equipment. It’s independent by TPS-NU, it can be mesured on periodic
basis and TPS-NU can raise an alarm when the measured time exceeds a programmed
threshold.
TACACS
Terminal Access Controller Access Control System
TPS
Permissive Tripping
TSC
Directive Tripping
UA
Power Supply Unit - Converter 24-48-110 V
UAT
High Voltage Command Unit (RSS=Solid state or RHG=quicksilver)
UE
TPS-NU Processing unit.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
Glossary 11 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
UL
TPS-NU Line Unit.
US
Service Unit.
USplus
Service Unit Plus
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
12 / 79 Glossary
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
1. Introduction
1.1 Conventions
For customers not familiar with Windows terminology, follows some examples of possible con-
trols.
1.1.1 CheckBox
It selects one or more options from a list (see Figure 1.1(a)).
1.1.2 ComboBox
It selects a single option from a list (see Figure 1.1(b)).
1.1.3 Menu
It allows to introduce a command with the rigth key of the mouse.
See an example in Figure 1.2.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
CHAPTER 1. INTRODUCTION 13 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
1.1.5 ListBox
It allows to select one or more option from a list (Figure 1.4).
1.1.6 Wizard
Procedure for a step-by-step data insertion (Figure 1.5).
The user must fill forms in a sequence and move forward and backward.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
14 / 79 CHAPTER 1. INTRODUCTION
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
Pointing mouse on an object (slot, connector etc..) and clicking with right key of mouse a context
menu will opened with commands related to pointed object (Figure 1.6).
Near the text could be present some icons, to indicate that the text is particularly relevant for
some topic, see the following table for key.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
CHAPTER 1. INTRODUCTION 15 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
16 / 79 CHAPTER 1. INTRODUCTION
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
2. Product Description
This manual describes the features of the tpsnu ct product, used to manage TPS-NU equip-
ment.
2.1 Identifiers
The product referred by this manual has following identifiers:
• Product : tpsnu ct
• Code : 653071000-A0-LM — 653071000-B0-LM — 653071000-C0-LM
<cod>_<vers>.exe
where:
• <cod> is the Selta code
• <vers> 3 digit version plus optional indicators (present on some products) coded as fol-
lows: V R P bldN
– V Version
– R Revision
– P Patch
– <bldN> is the ’build id’, a serial number incremented at each official release.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
2.1.2 Codes
Some of these functions can be realized without an available TPS-NU (the PC is sufficient),
others need of connected equipment. The possible functions without TPS-NU are:
• Create.
• Save on disk.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
In the latest version of product, the USplus management has been introduced. The new card
allows, with the assignment of an IP address, to communicate with TPS-NU through the net-
work.
This feature innovative compared to the previous card US opens the user the possibility of con-
figure the device remotely by establishing a socket TCP/IP connection between the card and
configurator. This connection allows the transfer of information across the network. The USplus
board also implements additional features such as:
• Remote monitoring apparatus, using SNMP;
• recovery of synchronization.
To support these new features, the configurator operations has been extended .
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
written authorization.
20 / 79
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
3. Installation
3.1 Requirements
Necessary elements:
• Distribution of the software (code 653071000-A0-LM or 653071000-B0-LM or 653071000-
C0-LM.).
• software activation Key (if applicable) to be used the first execution of the program.
If the PC is not equipped with native RS-232 intercace is possible to use PCMCIA Multi I/O
adapters (suggested choice) or adapters USB/RS-232 (less reliable).
As a sample, follows the product used by Selta SpA in testplant:
• Multi I/O cards:
Argosy SP 320-232 PCMCIA Serial Card
• USB/232:
Prolific Technology Inc. USB/232 adapter (driver 2.0.0.18)
ATEN International UC-232 USB-SERIAL CONVERTER.
3.3 Installation
Select the proper installation package, run it (double click on the the related icon) and follow the
related instruction.
Usually you have to indicate only the directory where you wish to install the software.
Note: in case of update, the installation will automatically overwrite to the previous one.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
CHAPTER 3. INSTALLATION 23 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
24 / 79 CHAPTER 3. INSTALLATION
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
4. Program Start
Start the program with a double click on the desktop icon or select the tpsnu ct group in the
Programs-Selta section on the application bar and click on ”tpsnu ct”.
4.1 Login
When started, the program requests the authentication with username and password.
To every username is associated a privilege level.
Every command has privileges minimum demanded for being executed.
It is possible to define new users assigning to everyone a privilege.
The informations in the Login dialogue are:
• New Equipment (Ctrl-N) - Once you started the tpsnu ct software (Fig. 4.2), following
options are available (see Figg. 4.4 e 4.5):
– Working Mode:
* Configurator (Off-line) creates a new configuration file of an equipment of type
specified by ’Equipment Type’ field.
* Monitor (On-line) uploads a configuration from a connected TPS-NU, in this
case the field ’Equipment Type’ is ignored.
– Site Name: represents the site name, if not specified the default name is considered.
(Site Name). If the Working Mode selected is Monitor this field is disabled.
– Database: if you selected ’Configurator’, this radiobotton specifies if you want to start
from an existing configuration or if you want to create new configuration. If an existing
configuration has been called, its name is placed in the title bar.
– Equipment Subtype: if you selected ’New Database’, this field selects the TPS-NU
subtype.
– Connection type: Local or Remote.
– Transport Type: Is possible choose between Serial (US) and TCP (USplus).
Choosing the serial communication is necessary set the serial port name used to
communicate with the equipment (Fig. 4.8).
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
If transport type is TCP/IP, the equipment must be equipped with an USplus card
otherwise is not possible communicate.
In the case of TCP transmission must indicate the machine’s IP address and port
on which to communicate (6000) (Fig. 4.7). As default the card USplus born with
the same IP address to 192.168.0.1/24, opening the first session configuration will
be necessary to specify this IP address to communicate with it. This requires you to
work offline by directly connecting via Ethernet cable your PC to card and assign it
an IP address belonging to the same network (eg 192.168.0.100).
• Open Database (Ctrl-O) - opens an existing database (Fig. 4.3). The user must choose
among the following parameters (Fig. 4.6):
– Transport Type: Is possible choose between Serial (US) and TCP (USplus).
Set the parameters required depending on the type of transport (Fig. 4.8 o Fig. 4.7))
– Database: Allow to select a configuration file (*. db), and to open a session mode
configurator, initializing the configuration parameters to the values contained in db
file.
• Exit (Alt-X) - quits the program.
The Configurator operation mode allows to create, modify, print, save, transfer from/to the
equipment the configuration tables.
Furthermore it allows the upgrade of firmware on TPS-NU cards. In configurator mode is possi-
ble to choice if see the device in front or rear mode using the related checkbox (Fig. 4.5).
The operation mode Monitor allows to display the configuration that resides on the equipment,
the diagnostic information coming from it and to send some commands to the equipment.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
To communicate with the card USplus you need to perform the authentication procedure, only
in this way creates the communication channel on which SSH will transit information.
The card provides the user the ability to choose the authentication mode required for opening
configuration sessions, choosing from one of the following methods:
• Local authentication credentials stored on the card
• Remote authentication via RADIUS server
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
Depending on the level of privilege with which you have authenticated, some items in the menu
configurator and some items in the menu of the cards may be disabled. For example, operations
such as download: download configuration and download fw are not enabled when you log in
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
as a guest.
After the login operations with the default IP address, is possible to assign another IP address
to USplus, it will be included in the initial menu when requesting address equipment you want
to configure. Refer to items in the US contextual menu and select Display Network Data and
then Download Data Network. When the board is restarted, selecting the Options-Reset US,
the new IP address will be loaded.
The USplus allows you to export diagnostic apparatus through the SNMP protocol. Is possible
to choose the version of SNMP to use and define the necessary settings, you can also activate
the automatic sending of SNMP TRAP to the occurrence of some specific alarms of apparatus.
By default, the card comes with the following configuration:
• Protocol version: 2c
• Community: public
To change SNMP settings, refer to the US context menu and select the item Show SNMP data
e then Download SNMP data. When the board is restarted, selecting Options-Reset US,the
new SNMP settings will be loaded.
4.3 Autorizzazioni
In relation to the operating mode (configurator or monitor) and user type with which you are
logged on the configurator, some features will be enabled or not. The tab.4.1 shows the mini-
mum privileges for enable a particular command. The tab. 4.2 is the legend of the levels used
in the tab. 4.1: L stands for local authentication, the authentication that is used to access the
configurator while R indicates remote authentication, used to authenticate all’USplus remotely.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
5. Basic features
Both in Configurator session and in Monitor session, it’s possible to make a few operation, de-
scribed below.
Session Management
Possible operations are:
• Login - see sec. 4.1
• Logout - closes actual session, tpsnu ct shows a confirmation message
• User Management - (valid only at level 1, see Fig 5.2) for users management;
tpsnu ct allows 4 options:
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
An optional comment.
There are some predefined users with following characteristics (not modifyable): For each
operation, required levels are defined in table 5.2.
Fw Management
Possible operations are:
Import Fw Before downloading a FW, is necessary to import it (see Fig. 5.4). This means that
tpsnu ct must read and cross-check Firmware (FW) and Release Notes (RN) files in order to
avoid any error in file manipulation: if the wrong RN is associated to a FW, the import operation
will fail. Furthermore, the user will identify a FW with its identifier (assigned by Selta) and not
with a filename (that can be changed by everyone, could give truncation problems in case of
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
long names and so on). If the Release Notes file is not available, select ’Cancel’ on the related
file selection box.
After the Import operation, FW and RN files are stored in a proper directory.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
with:
Level Description
1 Administration
2 Super User
3 Normal User
4 Low User
5 Read Only
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Rotate Debug Level - rotate in range 0..2 the level of debug, an higher debug level means
that the log window will show more detailed information about the operation carried out
from tpsnu ct
• English (o another language) - to choose the language of tpsnu ct; to make actual the
variation of the language is necessary to start again the application.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
6. TPS-NU Configurator
6.1 Introduction
The session activated in configuration mode can be shown as rappresented in Fig. 6.1 (rear
panel) or in Fig. 6.2 (front panel).
The user can create, modify, save and transfer the configuration database from/to TPS-NU.
The central picture reproduces the TPS-NU and the configured equipment.
Above are represented connectors located behind the rack. A double click on a connector shows
the pinout. The generic parameters and parameters of the Line Unit (UL), of the Processing unit
(UE), and of the High Voltage Command Unit (UAT) are modifiable through the configuration
window, accessed with a double click of the mouse on the desired card.
The general parameters (located up on the left in the figure 6.1 and 6.2) contains the information
related to the type of equipment, commands shaped, commands F-Duplex, and versions of
firmware running on the equipment.
Data in the panel are updated every time the user modifies the configuration parameters and at
every configuration Upload from the equipment.
A new session cannot be opened until the current session has been closed. This section will
describe the user interface commands that can be activated in the configurator mode and the
configuration parameters of the units.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Upload Configuration - Upload actual configuration and identify parameters from TPS-
NU. At the end of operation it comes dawned the general parameters containing the infor-
mations related to:
– Commands configured on equipment
– F-Duplex commands
– Versions of firmware residents on the equipment
If on try to upload the configuration from an equipment with versions to firmware not com-
patible, the operation does not come executed with successful. Through an error mes-
sage tpsnu ct it advises the operation of Download of the Firmware that tpsnu ct expects
in function of the subtype of equipment.
• Default Database - sets up the configuration parameters to default values (no HVU and
no LU equipped).
• Require Authentication - this feature is present only if the type of transport is TCP
(USplus), is used to ask the equipment authentication. Be prompted for credentials with
which to authenticate (Fig. 6.2.1), If the authentication is successful the US capabilities
are enabled.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Show Configuration - open the configuration window showing parameters of the selected
unit. For a description of parameters see par. 6.3.2.
• UE Firmware version - uploads the identifier parameters only of the UE card from TPS-
NU. At the end of the operation the general parameter panel containing information about
the firmware identifiers and versions installed on the equipment is updated.
• Download Fw - updates the firmware of the UE card of the TPS-NU equipment; the user
must carry out the selection.
Click on ’Download’ to start the download operation, the ’Release Notes’ button opens the
corresponding file (if available) in NotePad.
To download the firmware a <= 2 privilege level is required.
The Context Menu relative to UAT card empty (card not configured) contains the command:
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Create- it allows to configurate the card UAT. The application asks the user to confirm the
choice through the following Message Box: with click on button ”OK” is created of the card
and updated general paramenters;
with click on button ”Cancel” the card remains empty.
The Context Menu relative to configurated card UAT contains the following commands:
• Show Info - displays a brief description of the selected unit
• Show Configuration - opens the configuration window, for the UAT card selected. In
Monitor mode the data is read only. For a description of parameters see section 6.3.3.
• Remove - it allows to remove the UAT from configuration equipment
• Show Configuration - opens the configuration window, for the line unit. In Monitor mode
the data is read only. For a description of parameters see section 6.3.1.
• UL Firmware version - uploads the identifier parameters only of the UL card from TPS-
NU. At the end of the operation the general parameter panel containing information about
the firmware identifiers and versions installed on the equipment is updated.
• Show Configuration - opens the configuration window, for the service unit. In Monitor
mode the data is read only. For a description of parameters see section 6.3.4.
• US FW Version - (enabled only for USplus card) Uploads the identifier parameters only of
the US card from TPS-NU. At the end of the operation the general parameter panel con-
taining information about the firmware identifiers and versions installed on the equipment
is updated.
• Download Fw - (enabled only for USplus card) Updates the firmware of the US card of
the TPS-NU equipment, the user must carry out the selection.
Click on ’Download’ to start the download operation, the ’Release Notes’ button opens the
corresponding file (if available).
To download the firmware a <= 2 privilege level is required.
• Show Network Data - (enabled only for USplus card) Is used to set the network data (Fig.
6.7). Command available only on USplus card. After the network data setting is possible
sent the information to TPS-NU equipment using the command Download Network Data.
When the board is restarted, by selecting Options-Reset US, the new IP address will be
loaded.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Upload Network Data - (enabled only for USplus card) Transfer the network information
from TPS-NU. This data can be read choosing the command Show Network Data.
• Download Network Data - (enabled only for USplus card) Transfer the network infor-
mation to TPS-NU. This data are set choosing the command Network Data of US card
context menu.
• Show SNMP Destination - (enabled only for USplus card) is used to set the adress of
trap destination (Fig. 6.8). Command available only on USplus card. After the network
data setting is possible sent the information to TPS-NU equipment using the command
Download SNMP Destination.
In the case of SNMPv2 is required to enter only the community , in the case SNMPv3
is also required Username and Password. If you want to activate TRAP, select the Trap
Destination Enable and configure one or more destination addresses to which to send.
When you restart the board, can be performed by selecting the Options-Reset US, it will
load the new SNMP data.
• Upload SNMP Destination - (enabled only for USplus card) transfer the trap information
from TPS-NU. This data are set choosing the command Show SNMP Destination of US
card context menu.
• Download SNMP Destination - (enabled only for USplus card) transfer the trap informa-
tion to TPS-NU. This data can be read choosing the command Show SNMP Destination
of US card context menu.
• Show Sync Data - (enabled only for USplus card) is used to set the synchronization
data(Fig. 6.9). Command available only on USplus card. After the sync data setting is
possible sent the information to TPS-NU equipment using the command Download Sync
Data. Rebooting the card, through the voice Options-Reset US, the new settings for the
synchronization mode will be loaded.
• Upload Sync Data - (enabled only for USplus card) transfer the synchronization informa-
tion from TPS-NU. This data are set choosing the command Show Sync Destination of
US card context menu.
• Download Sync Data - (enabled only for USplus card) transfer the trap information to
TPS-NU. This data can be read choosing the command Show Sync Destination of US
card context menu.
• Show Authentication Data - (enabled only for USplus card) is used to set the TACACS
protocol data(Fig. 6.10). Command available only on USplus card. After the Authentica-
tion data setting is possible sent the information to TPS-NU equipment using the command
Download Authentication Data.
If the authentication choice is LOCAL, the only field configurable is the password of the
default user root.
If the authentication choice is RADIUS can be configured in the following fields:
– IP address of the authentication server
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Upload Authentication Data - (enabled only for USplus card) transfer the synchronization
information from TPS-NU. This data are set choosing the command Show Authentica-
tion Data of US card context menu.
• Download Authentication Data - (enabled only for USplus card) transfer the trap infor-
mation to TPS-NU. This data can be read choosing the command Show Authentication
Data of US card context menu.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Events Configuration : the command transmitted on the channel through a sequence for
the numerical vector and through a frequency for the analog vector will be referred to as
event. With the configurator you can:
• Create new events : You can choose a combination of commands in transmission and
reception amongst the configured UAT.
The user will see: Tx Command − > Rx Command.
• Increase/Decrease priority : The events created are displayed in order of priority (from
priority 0 upwards). The priority of an event in the list can be increased or decreased.
• Delete events
• Display details : The user can view the details of the event listed, that is the event number,
priority and status.
For further details on the events configuration see [2]. In the lower part there are the connections
to specific configuration windows for every card.
The description of the configuration parameters and the units they refer to follows below.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Line Unit - selects the type of line interface according to the application selected. Possible
combinations are displayed in tables 6.1 and 6.2.
The configuration parameters changes according to the line unit selected.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
- = not used.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Sources of generic alarm - it allows to select which alarms contribute to the activation of
the generic alarm, possible choices are:
– Block - Emission block
– AL-MG - Loss of Guard signal
– AL-TAC - Transmission time alarm (measured value higher than forecast).
– AL-BER/SNR - High Bit Error Rate
Single assets if the threshold parameter BER has been shaped
– AIS - (meaningless in case of firmware ue bf r, ue stn r) and ue ste r).
– Inconsistent Configuration - Wrong configuration.
– Missing Firmware
– AL-ADD - Address Alarm (active only if the control channel is enabled).
– AL-TPS-REM - Remote TPS alarm, available only with ue stn r and ue ste r.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Sources of remote alarm - it allows to select which alarms contribute to the activation
of the remote alarm. The choices are active single if the channel of remote control is
qualified. The possible choices are:
– LALR - Local alarm of remote equipment.
– RALR - Reception alarm of remote equipment.
– GALR - Generic alarm of remote equipment.
• Sources of alarm for Line Unit - it allows to select wich alarms contribute to the actiova-
tion of the relative alarms you to the Unit of Line, the possible choices are:
– Off
– 10e-3
– 10e-4
– 10e-5
• Remote Control Channel
– Enable Remot Control
– Enable Address Remote Control
* Address local equipment
* Address remote equipment
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• Command Type - The equipment allows the transmission of the commands if the ’START’
command is present or not. The possible configuration choices are:
– Start: send if also ’Start’ contact is present
– No Start: send in every case with command present.
• Command Mode - the possible choices are:
– Normal
– Continuous: allows the returners to be maintained without permanently occupying
the transmission. Uses two events (one for the Set and one for the Reset).
• Command return - The possible choices are:
– Local : supplies the return of the command transmitted on AUX contact.
– Remote : duplicates the received command on the AUX contact.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Minimum Reception Duration - configures the minimum duration of the returned com-
mand. It can assume a value between 0ms and 500ms, (0ms corresponds to timer off)
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
7. TPS-NU Monitor
7.1 Introduction
The session, activated in monitor mode, opens a view as in Fig. 7.1.
The user can:
• view alarms and diagnostic information,
• view and save configuration and identifier parameters,
• view and reset events’ history,
• reset commands’ counters,
• activate test off-line and view results,
• set equipment date and time,
• reset UE and/or UL cards,
• activate or deactivate RTC,
• activate test TAC and view results,
• activate continuous commands’ manual reset.
The central figure represents the TPS-NU rack with actual configuration (type of line unit, num-
ber of UAT. etc.).
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
Aloft to the right on the window there are the current date and time of the equipment (Fig. 7.8).
With the proper permission it is possible to set date and time, by selecting the item ”Time/Date
setting” in the ”Operation” menu. The generic parameters and the parameters of the Line Unit
(UL), Processing Unit (UE), Service Unit (US) and of the High Voltage Command Unit (UAT) are
shown through the configuration window.
The configuration window can be accessed, but not changeable, through the Operations menu
(Alt+p), by clicking on Show Configuration.
The status of the cards is represented graphically with the colour of the Status Indicator (Fig. 7.2).
The color of indicator reflects the status: green means no alarm and red means alarm.
To see detail of alarms, click on a red position, you will see the list of alarms on the related card
(Fig. 7.3). The general parameters panel (top left hand side, Fig. 7.4) contains information about
type of equipment, configured commands, Full-Duplex commands and firmware identifiers and
versions in the equipment. Under the general parameters there is a panel with equipment Local
Alarms (Fig. 7.5):
• Damaged machine (LALL)
• Line summary (RALL)
• Generic alarm (GALL)
• Emission block.
There is another panel with remote equipment alarms (only with the firmware ue seq r, Fig. 7.6):
• Damaged machine (LALR)
• Line summary (RALR)
• Generic alarm (GALR)
• Address Alarm.
The panel on the top right hand side, shown in Fig. 7.7, next to the sub-rack, contains the
equipment’s diagnostic information:
• Guard level (dBm): if the used interface is analog (low frequency 0-4 kHz, analog or digital
power line carrier)
• BER level : if the used interface is digital (optical fiber, G703, V11)
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• SNR level (dB): if the used interface is analog (low frequency 0-4 kHz, analog or digital
power line carrier)
and for each configured UAT unit:
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Number of Starts
• Number of transmitted commands
• Number of received commands.
In the top on the right there is the date and time of the equipment (Fig. 7.8). Under the date there
is the indication whether the machine that you are connected to is local or remote as shown in
the Fig. 7.9. After there is the site name (Fig. 7.10), this data could be modified through the
choice of Operation/Show Configuration.
Another window contains the transport type (Fig. 7.11).
The main connectors of equipment are shown above the sub-rack, as in Fig. 7.12. Under the
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
sub-rack any commands (transmitted or received) or starts are shown in real time with the
messages in Fig. 7.13:
• Start A (or B or C or D)
• Tx Command A (or B or C or D)
• Rx Command A (or B or C or D).
Every command (transmitted or received) and every start is recorded by the relative software
counters.
A new session cannot be opened without previously having closed the current one. This section
describes now the user interface commands which can be activated in the monitor mode and
the alarms associated to the single units.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
Show Configuration
It opens configuration window with all not changeable parameters.
Acquisition Pause
It interrupts the acquisition of diagnostic (alarms/signalling). If actived, tpsnu ct shows message
”ACQUISITION PAUSE!” on Status Bar.
Reset Counters
It resets counters of commands and/or starts of the selected UAT (if configured). tpsnu ct opens
the window as in Fig. 7.14 for the selection of the counter to reset.
Test Off-Line
It allows to enable the off-line test of the UAT units: the test allows to check that command execu-
tion relays and transmission command input circuits on each board operate correctly (Fig. 7.15).
tpsnu ct recommends to the user to disconnect the field and external battery. In fact the actuator
relay and sender opto-isolator contacts have to be tested, so it is necessary to work off-line and
use the special test cable for TPS-NU, provided in the TPS-NU maintenance kit.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
Stored Events
It shows all 2048 events in chronological order. For each event is indicated date, time, actived
alarms and activated commands. This operation requires some minutes. At the end of the
operation, the result is shown in a window as in Fig. 7.18. Finally it is possible to save the
events in a text file. In the following is represented how to count the events: it is necessary
count the transition. For example the following data:
• PTxC
• PTxC, PRxC
• PRxC
• No Allarms - No Comands
represents 1 transmit event and 1 received event, see the Fig. 7.19 that describes the behaviour
of events PTxC e PRxC.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
Reset Events
It clears all events stored in equipment memory.
Reset CC
If a command is configured as continuous command, a reset of actuators is forced and, if
conditions form the field are met, a reset event is sent to remote TPS-NU. Finally a report of the
operation is shown.
Reset UE
It resets the firmware running on UE card.
Reset UL
It resets the UL hardware and, if applicable, the firmware running on it.
RTC On
It starts the RTC chip, which maintains date and time even if the equipment is switched off.
RTC Off
It switches off the RTC chip. This procedure is suggested when the card is not working to
improve the RTC duration.
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
• Missing Card
• Card fault.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
• MG No Guard Signal
• ALL-TAC TAC Alarm
• BER / SNR Bit Error Rate beyond threshold / SNR value above the alarm threshold. The
alarm displayed to the user depends on the configured line interface (digital/analog).
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
8. Other informations
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
Index
Alarms
local, 64
remote, 64
card
UA, 16
UAT, 16
UL, 16
FW, 16
Installation, 23
Port RS-232, 23
RTC, 16
Software Key, 23
status
indicator, 64
TAC, 16, 69
TSC, 16
User level, 38
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
INDEX 77 / 79
User Manual
TPS-NU MT 653071000-GB Ed.3.7
End of Document
© SELTA S.p.A. All right reserved. Passing on and copying of this document, use and communication of its contents non permitted without
written authorization.
78 / 79 INDEX
User Manual
MT 653071000-GB Ed.3.7 TPS-NU
Selta spa
- Via Emilia 231 • I-29010 Roveleto di Cadeo (PC) • Italy
T +39 0523/50161 • v +39 0523/5016333
k info@selta.it • Ï www.selta.com
© SELTA S.P.A. All right reserved. Passing on and copying of this document, use and communication of its contents forbidden without authorization.
written authorization.
INDEX 79 / 79