Risk of Electric shock or even Death. High Voltages are present . Pump Features
Ensure unit is isolated from the mains before removing rear cover!
Fixed speed cyclic timer control
Timed dose, up to 60 seconds (T1 ‘ON’)
Danger! Keep hands, loose clothing and long hair away from rotating Pause time interval, up to 60 minutes (T2 ‘OFF’)
parts! Priming function
Safe and easy tube load facility
Limits of use Embossed 2 button overlay
Do not use in conjunction with life support equipment. Function corresponding LED`s
Do not connect pump to human body. IP66 Enclosure
Up to 4 Bar pressure handling
Fuse
F1 is located on the P.C.B. this will protect motor and circuit. Under normal operating Flow rates up to 80ml/min
conditions this fuse should not require replacement. In the event of fuse failure a 2 roller/2 guide roller Rotor
replacement fuse should be fitted, its value as stated in the technical overview.
Qualified personnel should investigate repeated fuse failure!
Technical Overview
Warranty
This product is guaranteed to be free from defects in material or workmanship for a period PCB Microprocessor controlled timer circuit
of 12 months from date of purchase, excluding consumable items such as tube and Power supply 230VAC 50Hz 15W (110VAC 60Hz Option)
rollers. Indicators Power `On` (Green)
Dosing in progress (Green)
Declaration of Conformity
Verderflex Aura Dosing pump range part No's: - Pause time interval (Red)
181.XXXX & 182.XXXX, Connectors 6 x 4mm and 9 x 6mm
as stand alone products conform to EC Directives: Motor 220VAC 50Hz Synchronous 50 RPM
Gearbox Planetary (7.5 Ratio)
Machinery Directive 2006/42/EC Output Torque 0.46Nm
Low Voltage Directive 73/23/EEC Working Temp 5 – 40˚C
EMC Directive 2004/108/EC
Storage Temp 0 – 50 ˚C
When installed into other equipment the pump should not Enclosure IP66 / NEMA 4
Fuse Rating 230V 50Hz 2A A/S (on PCB)
B-14-10-10
be put into service if compliance with these directives are
not maintained! 110V 60Hz 3.15A A/S (on PCB)
Weight: 2Kg
circuit
Will stay on solid when pump is dosing.
Supply/Plug should be fitted with a 3Amp fuse Flashes intermittently when tube load function is utilised.
Isolate the mains before undertaking any Illuminates solid for preset Pause time.
electrical work. All electrical work should be
performed by suitably qualified personnel
‘B’
How to start Pump
Fig 1
Connect mains supply to initiate dose
Primary Dimensions are in Millimetres
programme. Cycle begins with the Pause
Dimensions in Parenthesis are in inches
(off) time set by T2, once this has expired
STEP 2: SETTING THE DOSE & PAUSE TIMES the pump will begin to run for the duration
T1 Dose time 1 – 60 seconds) T2 Pause time (1 – 60 minutes) set by T1. This cycle will continue
indefinitely until power is removed.
Power Applied
Run (ON)
0 – 60 Secs
Use a small flat bladed screwdriver or Pot trimmer to adjust
the 270° potentiometers, use the gradients as a guide for T1
the desired time requirement . T2
HOW TO CONNECT EXTERNAL TUBING Pause (OFF)
Cyclic
0 – 60 Mins
1
2
HOLE ‘B’