Professional Documents
Culture Documents
Risk of Electric shock or even Death. High Voltages are present. Pump Features
Ensure unit is isolated from the mains before removing rear cover!
Start/Stop button
Priming function
Danger! Keep hands, loose clothing and long hair away from rotating Safe and easy tube load facility
parts! Embossed 3 button overlay
Function corresponding LED`s
Limits of use IP66 Enclosure
Do not use in conjunction with life support equipment. Up to 4 Bar pressure handling
Do not connect pump to human body. Flow rates up to 80ml/min
2 roller/2 guide roller Rotor
Fuse
F1 is located on the P.C.B. this will protect motor and circuit. Under normal operating
conditions this fuse should not require replacement. In the event of fuse failure a
replacement fuse should be fitted, its value as stated in the technical overview.
Technical Overview
Qualified personnel should investigate repeated fuse failure!
Warranty
PCB Microprocessor controlled
This product is guaranteed to be free from defects in material or workmanship for a period Power supply 230VAC 50Hz 15W (110VAC 60Hz Option)
of 12 months from date of purchase, excluding consumable items such as tube and Input Signals Volt free contacts (initiate dose)
rollers. Indicators Power `On` (Green)
Dosing in progress (Green)
Declaration of Conformity
Verderflex Aura Dosing pump range part No's: -
Connectors 6 x 4mm and 9 x 6mm
181.XXXX, 182.XXXX, & 185.XXXX Motor 220VAC 50Hz Synchronous 50 RPM
as stand alone products conform to EC Directives: Gearbox Planetary (7.5 Ratio)
Output Torque 0.46Nm
Machinery Directive 2006/42/EC Working Temp 5 – 40˚C
Low Voltage Directive 73/23/EEC Storage Temp 0 – 50 ˚C
EMC Directive 2004/108/EC Enclosure IP66 / NEMA 4
When installed into other equipment the pump should not
Fuse Rating 230V 50Hz 2A A/S (on PCB)
110V 60Hz 3.15A A/S (on PCB)
be put into service if compliance with these directives are
not maintained!
B-14-10-10 Weight: 2Kg
LIVE
Screw ‘A’ Offset from
mounting surface PRIME press and hold button to “prime” the fluid to the outlet of
the pump, preparing the Aura for its initial dose.
TUBE LOAD press this button when replacing the tube assembly.
EARTH NEUTRAL This will rotate the rotor at small safe intervals enabling a swift
3.6 [0.14]
tube change and reducing the risk of trapping anything between
‘A’ Fig 2 the rotor and the occluding surface of the pump casing.
Supply/Plug should be fitted with a 3Amp fuse Will stay on solid when pump is running.
Flashes intermittently when tube load function is utilised.
Isolate the mains before undertaking any
electrical work. All electrical work should be
performed by suitably qualified personnel
‘B’
VOLT FREE TRIGGER INPUT
Close contacts to begin pumping ,
Fig 1 Open contacts to stop
Primary Dimensions are in Millimetres
Dimensions in Parenthesis are in inches
CN2
HOW TO CONNECT EXTERNAL TUBING
P.C.B.
HOLE ‘B’